MPO MicroCable Trunk Assembly

Similar documents
40G QSFP+ (MPO) to 4x10G SFP+ (8xLC) Assembly

MTP Loose Tube Trunk Assemblies. Features. Applications.

Fiber Optic, Breakout cable, tight buffered, 900 microns

LX2 High Density LGX 4U Patch Panel

LX2 High Density LGX 4U Patch Panel

MIC Unitized Plenum Cables, Fibers

Micro Fibre Indoor Cable Multi-core (Up to 96 Fibres) Applications. Features

ENTERPRISE FIBER OPTIC CABLE. Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore

ENTERPRISE FIBER OPTIC CABLE. Interconnect Indoor Indoor/Outdoor Outdoor ADSS MicroCore

MIC Plenum Cables, 2-24 Fibers

Volition Fiber Optic Cable

Plug & Play AnyLAN Systems

Volition. Fiber Optic Cable. 3Innovation

Mini Breakout Distribution Cable Multi-core ( Fibres)

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

fiber optic cable Outdoor Cables

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

LC Cable Assemblies. Fiber Optic Products Catalog. Product Facts. LC Cable Assembly. Hybrid LC-SC Cable Assembly

FiberExpress Distribution Cables Tight Buffer Indoor Riser & Plenum Rated

Mining and Petrochemical Tray-Rated Fiber Optic Cables

Application Specification. Optical Fiber. Aramid Yarns. 2mm Subunit Jacket. Strength Rods. Outer Jacket

Optical Fibre Fibre Cables

Indoor/Outdoor Cables Single-Armored, Plenum, Tight Buffered Distribution Indoor/Outdoor Cable

Laser Optimized Multimode

Mini-Span ADSS Cable

Fiber Cables & Hardware

50µm µlinx Avionics Cable

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

Introduction to Fiber Cable Assemblies FiberDeep and Cable Assemblies

S Ingle Mode Fiber Patch Cord and Pigtail (SC/APC, LC/APC)

FC/APC Patchcord FC/APC. Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss

Interconnect Cable Simplex and Duplex

DNV-GL HH CE RoHS-II conform

Datasheet Outside Plant Cable

Get Fiber Smart. Part 1 : Best Practices in Enterprise Fiber Connectivity. Part 3: Best Practices in Tier2 Enterprise Fiber Link Testing and

Product Bulletin. Be Certain with Belden. Belden DataTwist 1200 Cables

Outside Plant All Dielectric

ezspan ADSS Short Span All-Dielectric Self-Support Loose Tube Cable

P R O D U C T C AT A L O G T ALOG

2001 PRODUCT CA T ALOG

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

ExpressLT Dry Dry Loose Tube Cable (2.5 mm)

FTTH simplex indoor cables with semi-tight tube

Rapid Fiber Panel Series Fiber Termination Panels with RapidReel Technology. 1st Edition

Reliability & Qualification Report for MEMS Based Variable Optical Attenuators

STFOC Optical Cable. Non-Kink Crush Proof

USB3.0 for Active Optical Cable

FIBER INSIDE PLANT. Rack Mount Panels Optical Modules Cable Assemblies Components

USB3.0 For Active Optical Cable SPECIFICATIONS

RP SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188, PE-B100, PE-C100, inch, LMR-100

HARTING. Interface Connectors. People Power Partnership

ezprep Gel-Free Loose Tube Gel-Free Loose Tube Cable (2.5mm)

Tight Buffer Distribution Plenum Cable Type OFNP, CSA FT6

USB3.0 For Active Optical Cable SPECIFICATIONS

Article number: Sheath marking ACE - TKF LTC-S RP 12x SM G.657.A1 (2x6) A-DQ(ZN)B2Y {Batch} {Year} {Length}

ezspan ADSS All-dielectric self-supporting loose tube cable

HITRONIC HQN Single-mode & Multi-mode Glass Optical Fiber Cable for Outdoor Applications

Modular Enclosure Solutions RACK IQ - ENTERPRISE & HYPERSCALE DATA CENTER CABINETS

Outlets terminate all shielded and shielded cable constructions AWG ( mm) size conductors.

Industrial Optical Cables

Upgrading the Boxer LAD blower module

Parameter Typical Maximum

Avionics Optical Cables

Data Center Solutions Entrance Facility Main Distribution Area Horizontal and Equipment Distribution Areas. 1st Edition

O P T I C A L F I B R E C A B L E S CONTRIBUTING TO DIGITAL INDIA

P255 Stainless Steel Pressure Transducer

Long Span ADSS All-dielectric self-supporting loose tube cable

SPEC No.: ZP REVISION: 1.1 ZP ELECTRON CO.,INC. Designer. Division. Approver

Ten 47 Limited CABLE PROTECTORS. Rev 6: March T: +44(0) F: +44(0) E: W:

LMR-195-LLPX. LMR -195-LLPX Flexible Low Loss Plenum Coax TIMES MICROWAVE SYSTEMS

ONTRAC WIRE MESH CABLE TRAY SYSTEM

Going the Distance - Solving Power Reach Issues With Diverse DAS Solutions

P1A Pressure Sensor. Description. Features. Applications MAIN FEATURES

Directory chapter 08. InduCom Robust and EMI protected D-Sub interfaces

SFP Fiber Optic Transceivers

LEGRAND CABLING SYSTEM 2 PERFORMANCE FROM TECHNICAL ROOM TO WORKSTATION

Ethernet 100 Mbps Quadrax

ATC Series QSFP CP Active Transceiver Cooler

Molex Premise Networks Systems Catalogue

Electrical Test voltage (Vrms) Service sea level at m M I II

Delta 3 rack system (DRS)

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read

Enhanced Management Frame (EMF)

ATC Series XFP CP Active Transceiver Cooler

New Product Bulletin. PowerCINCH The Modular Power Distribution and Motor Control Connection System for Machinery Applications

Connecting today for a greener tomorrow

Connecting today for a greener tomorrow

TE Connectivity DEUTSCH Single Module EN4165 connectors

CMC Hybrid Connectors Standard and Power Versions

Viking Series 10/100Base-TX/FX, Auto MDI/MDIx, Autonegotiable MIL-DTL-38999, Unmanaged Ethernet Switch

6000 Series Ethernet Buccaneer

VersiVision - High Definition Fiber Optic Video

Data sheet E-DAT Industry RJ45 coupler insert Cat.6 Class E

Series AM2D-Z 2 Watt DC-DC Converter

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

Premise Networks Division Product & Applications Guide Americas

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

Delta 3 rack system (DRS)

PureNet Data Communication Products Premises Copper Products

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Transcription:

Product updated on June 04, 2018 Trunk Assembly Trunks facilitate rapid deployment of high density backbone cabling in data centers or other high fiber density environments reducing network installation or reconfiguration time and cost. They are used to interconnect cassettes, panels or ruggedised Fan Outs, spanning MDA, HDA and EDA zones. Trunks are offered in all fiber types as standard 12 to 144 versions using a compact and rugged structure. The compact cables optimize cable-way use and improve airflow. Trunks are built with highest quality components. low loss versions are offered featuring low insertion loss for demanding high speed networks where power budgets are critical.

FEATURES/BENEFITS APPLICATIONS OS1/2 G.657A1, OM3, OM4 Jacket Standard Colours: G.657A1 Yellow, OM3 Aqua, OM4 Aqua (OM4 EricaViolet Available) 12xFiber Ferrule Up to 144xFiber LSZH, OFNP, OFNR Cable Jacket Options Female (standard) and Male Connectors Polarity A (standard), B or C Factory Terminated and Tested Optional Pulling Element Available Interface - components feature superior optical and mechanical properties Optimised Performance - Low loss and OM4 fiber assures low insertion losses and power penalties in tight power budget high speed network environment High Density - Multifiber connector and compact dimension of ruggedised ease space in costly data center environments Rapid Deployment - Factory terminated modular system saves installation and reconfiguration time during moves, adds and changes Reliability - 100% tested - Combination of high quality components and manufacturing quality control guarantees product to the highest standard Next Generation Network Proof - Emerging high speed protocol are going to use interface Data Centre Infrastructure Storage Area Network- Fiber Channel Parallel Optics Infiniband Emerging 40 and 100Gbps Protocols

SPECIFICATIONS ELEMENT CHARACTERISTIC Fiber OS1/OS2 G657A1, OM3, OM4 Tail Dimensions 3 mm Tails 12 Fiber Ferrule Terminations Boot Colour: Black Body Sleeve: MM (Beige), MM (Aqua, EricaViolet for EV Cable), SM (Green), SM (Yellow) 12/24 Cores Double Jacket OD Max 4.5 ± 0.3 mm Cable Diameter 24 Core Double Jacket Flat (4.2 ± 0.3 x 7.6 ± 0.4 mm) * 48 Core Double Jacket OD Max 9.0 ± 0.3 mm Crush Resistance 1000N/ 100 mm Double Jacket Microcable (up to 12 Cores) (Short/Long) 400N/ 150N Cable Tensile Strength Double Jacket Micro Cable (up to 48 Cores) (Short/Long) 1000N/ 300N Storage Temperature -20 ~ +60 C Installation Temperature -5 ~ +50 C Operating Temperature -20 ~ +60 C 12 Core - Rope attached to Aramid Pulling Element: Optional MultiSubunit- Pulling Eye Bonded to FRP Rod Contact customer service for product details confirmation if required Connector Performance CONNECTOR MATING IL AVERAGE IL MAX RETURN LOSS (MM) 0.10 db 0.35dB N/A (MM) 0.20 db 0.60dB N/A (SM) 0.10 db 0.35dB >60 db (SM) 0.25 db 0.75dB > 60 db Cable Performance CABLED FIBRE TYPE (ISO/IEC 11801) Attenuation Coefficient [db/km] OS1/OS2 OM1 OM2 OM3 OM4 0.38 Max (1310 0.25 Max 1310 0.34 Typ (1550 0.19 typ (1550 3.5 Max (850 1.5 Max (1300 2.9 Typ (850 1.2 Typ (1300 3.5 Max (850 1.5 Max (1300 2.7 Typ (850 0.9Typ (1300 3.5 Max (850 1.5 Max (1300 2.7 Typ (850 0.9 Typ (1300 3.5 Max (850 1.5 Max (1300 2.7 Typ (850 0.9 typ (1300 Minimum Bandwidth: Overfilled 200 (850 500 (850 1500 (850 3500 (850 N/A Launch [Mhz-km] 500 (1300 500 (1300 500 (1300 500 (1300 nm Minimum Bandwidth: Laser Effective Modal Bandwidth N/A N/A N/A 2000 (850 4700 (850 [Mhz-km]

TECHNICAL DRAWING ADDITIONAL INFORMATION TIA/EIA-568-C.3 and ISO/IEC 11801 IEC 61754-7 & EIA/TIA-604-5 NFPA 262 or IEC 60332 Materials compliant to RoHS and REACH SvHC IEC 60793

ORDERING INFORMATION Connector End A MF (F) MPF (F) Connector End B* MF (F) OM3 MPF (F) OM4 Fiber Type Fiber Count Pulling Element OM3 50/125 OM4 50/125 12 24 12 24 leave blank L No Pulling element Fanout tails (standard) Light Duty Pulling Element (12/24 s) FRP Rod Pulling Element Staggered Tails (48, 72, 96, 144 s only) Cable Length 1 1 Length Unit Cable Jacket Type Polarity Leave leave Blank metre blank LSZH A Polarity A 2 2 FT Feet RI Riser B Polarity B MM (M) MM (M) 7A1 G.657A1 48 48 3 3 PL Plenum C Polarity C MPM (M) MPM (M) 72** 72 5 5 RIUL Riser UL XX Open 96** 96 10 10 PLUL Plenum UL 144** 144 xx Specify E CPR Europclass Eca *Select connector end only if End B is different from End A ** Check Availability- Contact Customer Service *** MTP US Conec Connectors Available on Request- Add suffix "-US" to the end of the PN Example Part Number MF OM3 24 10 C MFOM32410C - 24Core (F)- (F)- OM3 50/125 LSZH Aqua 10mtr Polarity C FURTHER INFORMATION For additional information please contact your sales representative To view the product 360 visit the product page (Scan the QR code or visit the link below) Downloaded from https://www.aflhyperscale.com/product/ Trunk Assembly AFL Hyperscale reserves the right to make changes in this datasheet at any time without notice Information in this document is correct as of June 04, 2018 SCAN QR FOR PRODUCT PAGE Europe Americas Middle East & Africa India Asia Pacific +44 (0) 1908 441 144 emeasales@aflhyperscale.com AFL Hyperscale 2018 +1 800 790 9932 usasales@aflhyperscale.com +971 4 404 9606 mesales@aflhyperscale.com +91 80 46874687 indiasales@aflhyperscale.com +86 755 2561 3694 apacsales@aflhyperscale.com