COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

Similar documents
COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

Effective November 2016 Supersedes September 1998 (S )

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

Effective June 2016 New Issue

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

Effective May 2017 Supersedes January 2003 (S )

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

Effective May 2017 Supersedes December 2004 (S )

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

Effective March 2015 Supersedes S August 2012

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

High-voltage primary bushings installation instructions

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

Type NR oil switch installation and operation instructions

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

Figure 1. Kearney Type HX cutout.

Factory Authorized Mechanism Enhancement (FAME)

Two-way cable interlock kit for Magnum drawout circuit breakers

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Two-way cable interlock kit for Magnum fixed circuit breakers

3-way multi-family drawout cable interlock kit - type 32 - RF

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

S Voltage Regulators GENERAL. PRODUCT INFORMATION Introduction. Contents. Acceptance and Initial Inspection. Handling and Storage.

CCP2-FLR1-21_ flange-rod operating mechanism

COOPER POWER SERIES. Types VWE, VWVE27, VWVE38X, WE, WVE27, and WVE38X; threephase electronically controlled; installation and operation instructions

COOPER POWER SERIES. Externally fused block banks installation instructions. Capacitors MN230004EN

KFE10010-E. Reclosers. Contents. Type KFVE and KFVME (27kV) Bus Bar Kit KRK710-1 Installation Instructions. Cooper Power Systems

Instruction Booklet IB E. Contents

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

COOPER POWER SERIES. VFI tester operating instructions. Underground Distribution Switchgear MN285001EN

600 A 15 and 25 kv class Cleer grounding elbow

A 1.2 kv class externally removable secondary bushing

O & M Manual for the EATON Generator Ready Loadcenter

Flush Mount AIN ALPHA Meters. General. Hardware Kit

COOPER POWER SERIES. Type MOST Fluid-Insulated Switchgear; Installation, Operation, and Maintenance Instructions

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

CM52 Network Protector with Arc Flash Reduction Module

SHAW-BOX INSTRUCTIONS AND PARTS LIST SHAW-BOX RIGID MOUNT I-BEAM AND PATENTED TRACK TROLLEYS (PUSH & HAND GEARED - 1/2 THRU 15 TON RATED LOADS)

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

Edison modular fuse, vault application products

Installation Instructions For Motor Control Center (MCC) Units

COOPER POWER SERIES. RVAC Fluid-insulated Vacuum Switchgear; Installation, Operation, and Maintenance Instructions. Switchgear MN285005EN

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

ASSEMBLY OF TROLLEY TO HOIST

100 A externally operated one-, twoand three-phase tap-changer switch

Two-position sidewall (horizontal) and cover (vertical) mounted loadbreak switches

ENTERTAINMENT. BGV-D8+ Supplement to Manual # Tonne to 1.3 Tonne 250 kg to 1300 kg (REV. AA) E627NH

Effective October 2016 Supersedes January 2014 (S )

MG12K24T60V4 Mechanical Grapple

K-Limiter high ampere Companion II fuse

COOPER POWER SERIES. Type VSA12, VSA12B, VSA16, VSA20, and VSA20A operation and installation instructions. Reclosers MN280063EN

M-Force three-phase switch

25 kv class fused loadbreak elbow connector

600 A 15 and 25 kv class deadbreak accessories, tools, and replacement parts

Simple Electrically Operated Ground & Test Device For use in Type VCP-W Switchgear rated up to 15kV, 25 and 40kA UPPER TERMINAL SET VERSION

600 A 28 kv class Cleer loadbreak connector system

Transcription:

Recloser Mountings MN280071EN Effective May 2017 Supersedes February 1997 (S280-85-5) KA662R tank-lifting windlass assembly and installation instructions COOPER POWER SERIES

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. Installation Instructions MN280071EN May 2017 i

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY... i Safety for life... iii Safety information... iii Safety instructions... iii General.... 1 Assembly.... 1 ii Installation Instructions MN280071EN May 2017

! SAFETY FOR LIFE Safety for life Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power series products. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our Safety For Life mission.! SAFETY FOR LIFE Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment. G103.3 Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. G101.0 This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. G102.1 Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.3 Installation Instructions MN280071EN May 2017 iii

KA662R Tank-lifting windlass assembly and installation instructions For Types R, RE, RV, RVE, W, WE, WV, & WVE Reclosers in KA136R, KA137R, KA33W, or KA51W Mountings General Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install, or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.3 Easy access for internal inspection of pole-top mounted reclosers in the R and W series is possible with the installation of a KA662R tank-hoisting mechanism. This assembly can be used with crossarm mounting frames KA136R, KA137R, the two-pole mounting frame KA33W, and the KA51W frame which utilizes steel crossarm channels. The windlass assembly simplifies lowering of the recloser tank but cannot be used for lowering the entire recloser. To lower the tank, detach the 10 coverto- tank capscrews and crank windlass. For shipping and storing convenience, the complete windlass is shipped dismantled and must be assembled to the recloser and its mounting frame. All bearings, bushings and the gear box, however, have been lubricated at the factory with wheel-bearing grease, so no further servicing is required. Parts furnished are shown in Figure 1 as attached to a KA136R or KA137R mounting frame. The same parts listing is used for the KA33W and the KA51W except that these frames include mounting pads for this tank hoisting mechanism. Standard cable assemblies are about 19 feet long so that they can lower the tank about 6 feet, if necessary. Assembly 1. Attach the mounting strap (6) to the gear box and spool assembly (10) with the two 1 1/2-inch long capscrews (19). 2. Attach the mounting plate (15) to the separate spool assembly (11). Use the 7-inch long captive screws furnished with the spool assembly. Figure 1. Furnished parts (listing on page 2) 1 Installation Instructions MN280071EN May 2017

KA662R Tank-lifting windlass assembly and installation instructions 3. Interconnect the two spool assemblies with pipe (12) and roll pins (13). 4. Attach this partial assembly (6, 10, 11, 12, 15) to the lower crossarm (or on the cross brace pad when assembling to a steel KA51W frame) with the 7-inch spool captive capscrews mounting plate (7) and the loose 6 1/2-inch capscrews (8) and fasteners (9, 18). 5. Lay sheave support brackets (1, 2) across the top of the frame and attach the upper sheaves (4) to these brackets and the lower sheaves (3) to the tank. 6. Remove the hex nuts from stud ends of cables (5). Thread stud ends of cables through the tank sheaves, up through the upper sheaves and into the holes on the windlass spools. Fasten the stud terminal ends of the cables at the spools with the previously removed hex nuts. Suspend the looped end of the cable at the round head pin inside the upper sheave brackets (1, 2). 7. Take up slack in cables by operating the windlass crank (14) while directing both cables in an even wind. Both spools should contain the same amount of cable so the tank will be level when lowered. NNote: Two extra 1-inch cotter pins (16) are furnished with this assembly as spare gear box shearpins. These should be left tied to the windlass pipe until required. Table 1. KA662R Assembly parts list. Item no. Description Catalog number 1 Bracket, sheave support, R.H. KA300R 1 2 Bracket, sheave support, L.H. KA301R 1 3 Lower sheave KA121R 2 4 Upper sheave KA123R 2 5 Cable assembly KA592R 2 6 Mounting strap, gear box and spool KP1633R1 1 7 Mounting plate, crossarm KP1711R 4 8 Capscrew, 1/2 13 x 1 UNC-2A, hex K730115150700A 8 stl., galv. 9 Nut, 1/2 13 UNC-2B, hex stl., galv. K880215113050A 4 10 Gear box and spool assembly KA663R 1 Qty. per assy. Item no. Description Catalog number 11 Spool assembly KA15CE2 12 Pipe, spool inter- connection KKP1054CE7 1 13 Roll pin, 7/32 x 1-1/4, pipe K970801218125C 2 14 Crank handle KP1031R 1 15 Mounting plate, spool KP1712R 1 16 Cotter Pin, 1/4 x 1, brass, spare gear K970525125100A 2 box shear pins 17 Copper wire, for tying spare shear pins 1 18 Lockwasher, 1/2 med. stl. zn. plt., K900815050000A 4 Iridite #3 19 Capscrew, 1/2 13 x 1-1/2 UNC-2A, hex stl., galv. K730115150150A 2 Qty. per assy. Installation Instructions MN280071EN May 2017 2

KA662R Tank-lifting windlass assembly and installation instructions This page intentionally left blank. 3 Installation Instructions MN280071EN May 2017

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No. MN280071EN KA2048-118 Rev02 May 2017 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton s Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.