INDUSTRIAL HEAT TRACE

Similar documents
Heating Cables. For Industry Tracing

Pipe Freeze Protection Design/Install Guide

Heating Cable. Cut to Length in Field. Description

CAPABILITIES EXPERT TECHNICAL SUPPORT

Power-Limiting Cables

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Introduction to Heat Trace Cable Systems

3M Self Regulating Heating Cables

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction

120/240 Volts 3 Watt Floor Heating Cable System

Heating Cable. Construction

Type LT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Heating Cable. Construction

Type LT Self-Regulating Heater Cable For use in Ordinary (Unclassified) and Hazardous (Classified) Locations

Heat Tracing Products

MIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS

Self-Regulating Freeze Protection Heating Cable

Pictorial Index... A-14 Introduction to Heat Trace Cable Systems Installation Examples Engineering Guide Heat Loss Tables...

Product Overview. Application

XMI-L STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES

Self-Regulating Cables

NAMSR SELF-REGULATING FREEZE PROTECTION HEATING CABLE SELECTION

CX1 ProVector Explosion-Proof Heaters

Self-regulating cables

Self-Regulating Parallel Heating Cables. innovations in heat tracing

FREEZSTOP MICRO SYSTEM

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

NAMSR SELF-REGULATING CABLE FOR PIPE FREEZE PROTECTION / SPECIFICATION SHEET WSC-0930

Industrial, Heavy Insulated Mono-Tape. and Duo-Tape

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM

SELF-REGULATING CABLES

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

HEAT TRACE CABLE. Introduction to Heat Trace Cable Systems Mineral Insulated Heat Trace Cable Non-Metallic Sheath

STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES

DOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

QAA 132 Operating Manual for Heat Tracing System ELSR-MA and ELSR-WA

Certified to Protect. Built to Endure.

Product Catalogue. Worldwide Specialists in Electric Heat Tracing. HTS THERMTRACE HTS THERMTRACE HTS T

Self-regulating frost protection system for pipes

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.

XMI Mineral Insulated Heating Cables

THERMAL MANAGEMENT

HTSB system System overview

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

90 kva Transformer - 208Y Wye-N Primary Voltage - 230Y Wye-N Secondary Voltage - NEMA 3R

Products and Accessories. Information Guide

Heating Cable. Description

Heating Cable. Description

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

FM Approved Remote Kit Assembly (Part No ) Standard Remote Kit Assembly (Part No ) G2 SERIES G2 Industrial METER MODULES

Heating Cable. Description

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007)

Power Connection Kit installation instructions

Modified polyolefin (-CR) or fluoropolymer (-CT) outer jacket

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Electric Heating Product Catalog

FLEXTRACE. FSG - FSG/T - FSG/TP - FSG/TF Self-regulating cables for refrigeration. Applications. Characteristics

The advantages of the pipe tracing systems are: Sensor. Insulation Heating cable Aluminium tape. Fig. 1 Fig. 2

Installation Instructions Mineral Insulated (M.I.)

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Surface thermocouple Model TC50

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

INSTALLATION GUIDELINES. Design system and make a layout. For guidance, see attached layout and wiring diagram.

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

30kVA Transformer - 3 Phase Delta Primary - 380Y/220 or 400Y/230 Secondary - NEMA 3R

Snow Melting Mats Price Sheet

PrimaLine 3 XT 24V Wet Location LED Tape Light

Electronic Instrumentation

diode led FLUID VIEW 12V LED Tape Light 12VDC FEATURES Soft illumination Accent or ambient lighting Closet-safe Largest CCT selection QUICK SPECS

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing

Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) PIPE TRACING CABLES

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A

Installation Instructions

diode led BLAZE 12V LED Tape Light 12VDC FEATURES Most popular lighting solution Closet-safe Wide CCT collection Cuttable every 1 inch QUICK SPECS

CASCADE LED LIGHT BAR

Electric Heat Tracing INSTALLATION PROCEDURES

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Danfoss LX Electric Floor Heating

Self-Regulating Pipe Tracing Heating Cable Specification/Application Guide OPTIONAL JACKET. Performance and Rating Data. Catalog Service TSR31J

Electric Heating Product Catalog

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

QUICKTERM TERMINATION KIT

Product Instructions. Mixing Station. Features. Specifications. Materials

THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

ELSR Electric Self-Regulating Parallel Heating Cables

Instrument and Heat Trace Tubing Products

C Power Connection Kit

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.

AUTHENTIC LIFE SAFETY PRODUCTS SINCE 1940

AT100 Magnetostrictive Level Transmitter. High accuracy magnetostrictive liquid level transmitter K-TEK Products

75 kva Transformer - 208V Delta Primary Voltage - 480V Delta Secondary Voltage - NEMA 3R

45 kva Isolation Transformer - 480V Delta Primary - 400V Delta Secondary - N3R - Copper Windings

ASCO SERIES 185 Power Transfer Switches

Transcription:

INDUSTRIAL HEAT TRACE INDUSTRIAL HEAT TRACE www.valin.com

800-774-5630 www.valin.com HTS-6 SERIES The HTS-6 commercial grade heater cable is designed for use in both indoor and outdoor locations as well as for residential and commercial freeze protection on water pipes and drain pipes. In roof and gutter applications the HTS-6 provides a pathway for flowing water on the roof or in gutters and downspouts to safely distance itself from the building before the opportunity to re-freeze and cause damage. 3, 5, 6 w/ft @ 40 F HTS-6-1R: 120V HTS-6-2R: 208 V - 277 Vac 150 F (65 C) max Intermittent exposure temperature: 185 F (85 C) max Tinned copper 0.003 Ω/ft Type 2E, 3A, 3B, 3C UL: Pipe Heating Cables Industrial and Commercial 2700 SERIES The 2700 series of self-regulating heating cables are designed to supply a specified amount of heat at any point along their length in direct response to local temperature variations. These cables can maintain temperatures up to 150 F (65 C) and survive intermittent exposure up to 185 F (85 C) with power applied. 2700 cables can be cut to length and terminated in the field and will not overheat or burnout when overlapped. 3, 5, 8, 10 w/ft @ 50 F 110-120 or 208V - 277Vac 150 F (65 C) max Intermittent exposure temperature: 185 F (85 C) max T Rating: T-5 (10 w/ft), T-6 (3, 5, 8 w/ft) Tinned copper: 0.003 Ω/ft Stainless steel: 0.125 Ω/ft Factory Mutual: Class I, Div 1 / 2, Groups B, C, D Class II, Div 2, Groups F, G Class III, Div 1 and 2 STD. 130-03, -G, -W, -S Class I, Div 1 / 2, Groups A,B,C,D Class II, Div 1 / 2, Groups E, F, G Class III, Div 1 and 2 SEMCO - (CE mark)

COMPLEX TECHNOLOGY MADE SIMPLE 2300 SERIES The 2300 series of self-regulating heating cables are designed to supply a specified amount of heat at any point along their length in direct response to local temperature variations. These cables can maintain temperatures up to 250 F (120 C) and will with stand 150 psig saturated steam purging and maximum temperature exposure to 366 F (185 C). 2300 series cables can be cut to length and terminated in the field and will not overheat or burnout when overlapped. 5, 10, 15 w/ft @ 50 F 110-120 or 208V - 277Vac 250 F (120 C) max Maximum exposure temperature: 366 F (185 C) T Rating: T-3 Tinned copper: 0.003 Ω/ft Stainless steel: 0.125 Ω/ft Factory Mutual: Class I, Div 1 / 2, Groups B, C, D Class II, Div 2, Groups F, G Class III, Div 2 STD-130-03-G,-W,-S Class I, Div 1 / 2, Groups A, B, C, D Class II, Div 1 / 2, Groups E, F, G Class III, Div 1 and 2 SEMCO - (CE mark) 2000 SERIES The 2000 series of self-regulating heating cables are designed to supply a specified amount of heat at any point along their length in direct response to local temperature variations. These cables can maintain temperatures up to 375 F (190 C) and will withstand 190 psig saturated steam purging and intermittent temperature exposure to 450 F (232 C) with power applied. 2000 series cables can be cut to length and terminated in the field, and will not overheat or burnout when overlapped. 5 through 30w/ft @ 50 F (other wattages also available) 110-120 or 208V - 277Vac 375 F (190 C) max Intermittent exposure temperature: 450 F (232 C) max T Rating: T-2C Tinned copper: 0.003 Ω/ft Stainless steel: 0.125 Ω/ft Factory Mutual: Class I, Div 1, Groups B, C, D Class I, Div 2, Groups A, B, C, D Class II/III, Div 1, Groups E, F, G Class II/III, Div 2, Groups F, G Class I, Zone 1, Group IIB + H2, Class I, Zone 2, Group IIC 3(A,B,C), 5(A,B) Class I, Div 1* / 2, Groups B, C, D Class I, Div 2, Groups B, C, D Class II, Div 2, Groups F, G SEMCO - (CE mark)

INDUSTRIAL HEAT TRACE MINERAL INSULATED CABLE Mineral insulated cable is ideal for a wide range of industrial and commercial applications. It has resistive heating conductors embedded in Magnesium Oxcide. The MgO allows heat to pass to the stainless steel alloy sheath while not allowing electricity to pass, thus the sheath is temperature hot but not electrically hot. The sheath is fully annealed and easily bent to fit along a pipe. Output Wattage 5-35 W/ft Supply Voltage 120V, 208V-277V, 480V Continuous Maintenance Temperature: 100 F Intermittent Exposure Temperature: 1200 F Commonly Used For: long runs and high temperature applications ACCESSORIES Accessories are critical to the success of any heat trace system. Water ingress into a power box or end seal will quickly short out a heat trace run. And thermostats are an essential component of the thermal loop, saving money by powering off the cable when it s not necessary. Valin s combined power box and end seal kits Simplifies bills of material and reduces cost End of run lights provide visual indication of voltage present at the end of run Thermostats are essential for reducing energy costs and efficient operation Full complement of straps and tapes available for securing the cable to the pipe Part Number Description (1) Description (2) 2000 2300 2700 HTS-6 PCL-JB-ES-ST (3 or 12) Power Box Power Box, end seal and (2) clamps - X X X SCL-JB-ST, ( 3 or 12) Splice Kit Splice kit and clamp - X X X EOR- *voltage*, (3 or 12) End of Run Light End of run light and clamp X X X X 166013A11 Thermostat Adjustable line sensing thermostat X X X X 166018911 Thermostat Adjustable ambient sensing thermostat X X X X ENGINEERING Valin has application engineers who can assist you with designing and optimizing your heat trace system. We also partner with local contractors, providing the full turnkey experience at the lowest cost. Isometric Drawings BIM model Fully engineered Bills of Material Take Offs Site Supervision and installation Start up and Commissioning Panel Troubleshooting and Programming

CABLE SELECTION Selecting the right cable is as much art as it is science. The chart below can help guide you through the selection of products to ensure that you choose the right cable for your application. PRODUCT SELECTION AND CONNECTIONS Self-Regulating Heat Trace Self-regulating cable can be cut to length in the field and regulate heat output automatically in response to pipe temperature. The ability to easily wrap the cable around valves or flange pairs reduces installation time and lowers overall job cost. Valin s product lines and our knowledge optimize the system to maximize run lengths and ensure you have the smallest numbers of circuits possible. Series Heating Cable FM/CSA Approvals Maintenance Temperature F Class I Class II Class III Continuous Intermittent Ordinary Area Div 1* Div 2 Div 1* Div 2 Div 1* Div 2 Zone 1* Zone 2 2000 375 450 Yes B,C,D A,B,C,D E, F, G F, G B,C,D F,G IIB+H2 IIC 2300 250 366 Yes A,B,C,D A,B,C,D E,F,G E,F,G Yes Yes 2700 150 185 Yes A,B,C,D A,B,C,D E,F,G E,F,G Yes Yes HTS-6 150 185 Yes *Contact a Valin representative for information on Division I hazardous location systems

800-774-5630 customerservice@valin.com www.valin.com