Pump Specifications 405 Series Commercial Drain Pump (High-Temp)

Similar documents
Pump Specifications 250 Series Submersible Sump / Effluent Pump

Pump Specifications 290 Series 3/4 hp Submersible Effluent Pump

Pump Specifications 280 Series 1/2 hp Submersible Effluent Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications LE70-Series 3/4 HP Submersible Sewage Pump

Pump Specifications FL50 Series 1/2 hp Submersible Effluent Pump

Pump Specifications LE40 Series 4/10 HP Submersible Sewage Pump Pump

Pump Specifications LE100-Series 1HP Submersible Sewage Pump

Pump Specifications. LE50 Series ½ HP Submersible Sewage Pump

Pump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp

NOTE: LEH100-Series high-head pumps require a minimum application of 15' head. Do not use pump in this area use a smaller pump.

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

Pump Specifications FL100 Series Submersible Effluent Pump

Pump Specifications FL150 Series Submersible Effluent Pump

Pump Specifications FL60/FLH60 Series 6/10 hp Submersible Effluent Pump

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

Pump Specifications. Omnivore 2HP Submersible Grinder Pumps LSG200-SERIES (SINGLE STAGE) LSGX200-SERIES (TWO STAGE)

LITERS PER MINUTE TOTAL HEAD IN FEET TOTAL HEAD IN METERS GALLONS PER MINUTE

XFL70 FLOW RATE (LPM) Flow Rate (GPM)

XLE50 FLOW RATE (LPM) Flow Rate (GPM)

LITERS PER MINUTE GALLONS PER MINUTE

SKHS SERIES 2 HP 1-1/2 HP 1 HP 1/2 HP CAPACITY-U.S. G.P.M.

SKV40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 2" Solids: 2" GPM: TDH:

SPD50H/100H. Performance Data SPD100H SPD50H. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

HYDROMATIC SKHS SERIES SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

HYDROMATIC SK75/100 SUBMERSIBLE SEWAGE EJECTOR

HYDROMATIC SPX50/SPX50H EXPLOSION PROOF, SEWAGE EJECTOR

HYDROMATIC SPD50H/100H SUBMERSIBLE HIGH HEAD, DOUBLE SEAL EFFLUENT

Boand Arena Septic to Sewer Duplex Grinder Pumps (Commercial) Engineering Analysis

Pump Specifications Series. Pre-assembled Duplex Sewage System 30 x 36, 110 Gallon

HYDROMATIC HE8/HE12/HE20/HE25/ HE30/HE35/HE50 HIGH HEAD FILTERED EFFLUENT

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

KW Submersible, Single-Vane Impeller

GR NDER PUMPS. Technical Catalog

MYERS MODELS 4R AND 4RX

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

GR NDER PUMPS. 505 Woodland Rd., Mt. Pocono, PA Phone: (570) Fax: (570)

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

MYERS 3MW VERTICAL DISCHARGE WASTEWATER PUMPS. Sewage, high-capacity sump, effluent

MYERS MODELS 4V AND 4VX

ECC ECC Flow(USGPM) Sump & Effluent De-watering Drainage. Phase Voltage Approx Weight (lbs)

Series SFA Hz, 3450RPM. Submersible. ADI Water Garden Pumps

MYERS 4VCDP. 4" Solids Handling

Series 6SHV. Specifications: Series: 6SHV 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

SPECIFICATIONS EFFLUENT/SUMP SIMPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

MYERS MODELS 4RC AND 4RCX

MYERS MODELS 4VC & 4VCX

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

Series 6XSHD. Specifications: Series: 6XSHD 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

KG(X)3. Grinder Pumps. 3HP High Flow Grinder Pump (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve. Total Head (FT) Capacity (GPM)

Series 4XSHV. Specifications: Series: 4XSHV , 3450RPM, 60Hz 2-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling

MYERS MODELS 6VC & 6VCX

Contents Project: Model: Chk d: Date:

50 Hz Products. Commercial Duty Pumps Heavy Duty Solids Handling Pumps Grinder Pumps Lift Station Accessories. Trusted. Tested. Tough.

P U M P. Pumps for Municipal and Commercial Operations

Series 8SHDU. Specifications: Series: 8SHDU 25-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3.50" Spherical Solids Handling

Series 6SHM. Specifications: Series: 6SHM 15-30HP, 1750RPM, 60Hz HP, 1150RPM, 60Hz. 21 Frame Driver 3" Spherical Solids Handling

Series 4XSHM 18 Frame Driver 3" Spherical Solids Handling

Series 4XSHD. Specifications: Series: 4XSHD 3-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling

JDL SYSTEMS Submersible Sump / Sewage Pumps Table of Contents Project: Model: Chk d: Date:

4400JF (120V) Aerating Fountain Specifications

Series 4SHM. Specifications: Series: 4SHM 3-10HP, 1750RPM, 60Hz. 18 Frame Driver 3" Spherical Solids Handling. Solids Handling Submersible Pumps

8400JF (240V Single Phase) Aerating Fountain Specifications

barmesapumps.com BP33 & BP & RPM Installation, Operation & Maintenance Manual Submersible Sump / Utility Pumps

B. OTHER SUBMERSIBLE DEWATERING PUMPS

DSZ3. EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

Horizontal Jet Pumps 1/3-1-1/2 HP

KGX2-21. Grinder Pumps. 2HP Dual Seal Grinder Pump, External Start (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve

Series MSC Sewage Chopper Pumps

Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

ESE Series Cast Iron Sewage Pumps

Electric Submersible Pumps

D51 D61 D71 D91 Series

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

4" Submersible Motors

EBARA Submersible Propeller Pumps Contents Project: Model: Chk d: Date: Model

Sealless Magnetic Coupled Hot Oil Circulation Pumps acc. to DIN EN / ISO 2858 Type NMWR / NMWB / NMW. our. contribution for

ITT. Goulds Pumps 65L, 95L, 120L, 160L, 250L, 320L 6" Stainless Steel Submersible Pumps. Engineered for life B65-320L. Residential Water Systems

WHR/WHRH and WHRE WASTE HANDLING SUMP PUMPS

4" Submersible Motors XE-SERIES

Spa Pumps / Viper - 56-Frame

ITT. Goulds Pumps 5GS, 7GS, 10GS, 13GS, 18GS & 25GS. Engineered for life B5-25GS. Residential Water Systems FEATURES

PUMPING CURVES SBW / SLW SERIES. Power cord ft. Shut off ft. SBW series SBW300 1/ Vortex

Wilo Price Book. Pumps and systems for Building Services and Groundwater. Pioneering for You USA 60 Hz.

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

SUBMERSIBLE PUMPS DRAINER SUMP/EFFLUENT

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SUBMERSIBLE PUMP HSE RANGE

Installation Manual. Omnivore Grinder Pump Retrofit Unit LSG202-RE. LSGX202-RE 2Hp, V, 1 phase, Automatic LSG202-REX

MODEL 7ASX-8 SPECIFICATION

Technical Data 5430 M & W SUBMERSIBLE SOLIDS HANDLING PUMPS

Your Premier Pump Choice!

CPG 2HP Grinder Series

5CS, 7CS, 10CS, 13CS, 18CS & 25CS 5-25 GPM, ½ 3 HP, 60 HZ, SUBMERSIBLE PUMPS

4500C Series Vortex Pumps

5LS, 7LS, 10LS, 13LS, 18LS & 25LS 5-25 GPM, ½ 1½ HP, 60 HZ, SUBMERSIBLE PUMPS

BRCP6SM ITT. CentriPro. 6-10" Submersible Motors. For 6" and Larger Deep Well Pumps. Engineered for life

Transcription:

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 405_P1 R8/22/2017 Copyright 2017 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

405-Series Dimensional Data 405 SERIES DIMENSIONAL 405_P2 R8/22/2017 Copyright 2017 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

405-Series Electrical Data MODEL HP VOLTAGE PH. FULL LOAD AMPS LOCKED ROTOR AMPS THERMAL OVERLOAD TEMP STATOR WINDING CLASS CORD LENGTH FT DISCHARGE AUTOMATIC ALARM 405 ½ 115 1 7.3 16 140 C / 284 F F 10 2 YES 405-HV ½ 208/230 1 3.5 7 140 C / 284 F F 10 2 YES 405/A ½ 115 1 7.3 16 140 C / 284 F F 10 2 YES YES 405/A- EYE ½ 115 1 7.3 16 140 C / 284 F F 10 2 YES YES NIGHTEYE 405-Series Technical Data IMPELLER VORTEX HIGH TEMPERATUER ENGINEERED POLYMER SOLIDS HANDLING 3/8 PAINT (PUMP) MAX LIQUID TEMP MAX STATOR TEMP THERMAL OVERLOAD POWER CORD TYPE MOTOR HOUSING VOLUTE SHAFT HARDWARE ORINGS SHAFT SEAL WEIGHT TANK MATERIAL INLET SIZE DISCHARGE SIZE VENT SIZE POWDER COAT 82 C / 180 F CONTINUOUS CLASS F 155 C/ 311 F 140 C/ 284 F SJTOOW DEEP FINNED POWDER COATED ALUMINUM ENGINEERED POLYMER STAINLESS STAINLESS BUNA N ENGINEERED DOUBLE LIP WITH STAINLESS SPRINGS 23 LBS POLYPROPYLENE 405_P3 R8/22/2017 Copyright 2017 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

405-Series Specifications 1.01 GENERAL: The contractor shall provide labor, material, equipment, and incidentals required to provide (QTY) commercial drain pumps as specified herein. The pump models covered in this specification are Series 405 single phase pumps. The pump furnished for this application shall be model as manufactured by Liberty pumps, and have a maximum fluid temperature rating of 180 degrees F. 2.01 OPERATING CONDITIONS: Each drain pump shall be rated at 1/2 hp volts, single phase, 60 Hz. 3450 RPM. The unit shall produce G.P.M. at feet of total dynamic head. The drain pump shall be capable of handling effluent with 3/8 solid handling capability. The drain pump shall have a shut-off head of 34 feet and a maximum flow of 48 GPM @ 5 feet of total dynamic head. The pump shall be controlled with a piggy back style on/off float switch. 3.01 CONSTRUCTION: Each drain pump shall be equal to the Series 405 with Certified pump as manufactured by Liberty Pumps, Bergen NY. The motor housing shall be constructed of a deep finned powder coated aluminum. The motor housing shall be oil filled to dissipate heat. Air filled motors shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed with a Buna-N O-ring. All fasteners exposed to the liquid shall be stainless steel. The motor shall be protected on the top side with sealed cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord. The motor shall be protected on the lower side with an engineered double lip seal with stainless steel springs. The tank shall be made of polypropylene. 4.01 ELECTRICAL POWER CORD The drain pump shall be supplied with 10 feet of multiconductor power cord. It shall be cord type SJTOOW, capable of continued exposure to the pumped liquid. The power cord shall be sized for the rated full load amps of the pump in accordance with the National Electric Code. The power cable shall not enter the motor housing directly but will conduct electricity to the motor by means of a water tight compression fitting cord plate assembly, with molded pins to conduct electricity. This will eliminate the ability of water to enter internally through the cord, by means of a damaged or wicking cord. 5.01 MOTORS Single phase motors shall be oil filled, permanent split capacitor, class F insulated, NEMA B design, rated for continuous duty. At maximum load the winding temperature shall not exceed 155 degrees C unsubmerged. Since air filled motors are not capable of dissipating heat they shall not be considered equal. The pump motor shall have an integral thermal overload switch in the windings for protecting the motor. The capacitor circuit shall be mounted internally in the pump. 405_P4 R8/22/2017 Copyright 2017 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.

6.01 BEARINGS AND SHAFT Upper and lower ball bearings shall be required. The bearings shall be a single ball / race type bearing. Both bearings shall be permanently lubricated by the oil, which fills the motor housing. The motor shaft shall be made of 300 or 400 series stainless steel and have a minimum diameter of.311". 7.01 SEALS The pump shall have an engineered double lip seal with stainless steel springs. The motor plate / housing interface shall be sealed with a Buna-N o-ring. 8.01 IMPELLER The impeller shall be molded engineered polymer, with pump out vanes on the back shroud to keep debris away from the seal area. It shall be threaded to the motor shaft. 9.01 CONTROLS All units are supplied with CSA and UL approved automatic wide angle tilt float switches. The switches shall be equipped with piggy back style plug that allows the pump to be operated manually without the removal of the pump in the event that a switch becomes inoperable. The switches shall be mounted under a separately sealed access cover and tethered to a removable stainless steel rod for easy removal and serviceability. 10.01 PAINT The exterior of the casting shall be protected with powder coat paint. 11.01 SUPPORT The polyolefin tank shall be a free standing unit. 12.01 SERVICEABILTY Components required for the repair of the pump shall be shipped within a period of 24 hours. 13.01 TESTING The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture content and insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to ensure integrity of the motor housing. The pump shall be run, voltage current monitored, and the tester checks for noise or other malfunction. 14.01 QUALITY CONTROL The pump shall be manufactured in an ISO 9001 certified Facility. 15.01 WARRANTY Standard limited warranty shall be 3 years. 405_P5 R8/22/2017 Copyright 2017 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.