SEE VICTAULIC PUBLICATION FOR DETAILS

Similar documents
QuickVic Rigid Coupling for Steel. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE GROOVED COUPLINGS

Housing Coating: Orange enamel. Hot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)

Hot dipped galvanized. Optional Bolts/Nuts: (Available in imperial size bolts and nuts only.)

08.08 Vic-Check Valves

Lenntech Tel Fax

Style 99 Roust-A-Bout Couplings

Vic-Strainer WARNING. System No. Submitted By Spec Sect Para Location Date Approved Date IPS CARBON STEEL PIPE - GROOVED ACCESSORIES SERIES 730

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

08.20 VIC -300 MasterSeal Butterfly Valves

FIG Gruvlok Flange Adapter

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

11.02 Mechanical-T Bolted Branch Outlets

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

FIG Gruvlok Flanges

Size Inches UL ULC FM. Pipe Sch.

Couplings. Ductile Iron Housing Specifications. Coatings. Gasket Specifications. Bolt/Nut Specifications

08.12 Vic-Plug Balancing Valve

Series W706 AGS Butterfly Valves (300 PSI/2065 kpa)

Series 706 Butterfly Valves (300 PSI/2065 kpa)

Series 709 Butterfly Valves (175 psi/1270 kpa)

Series W709 AGS Butterfly Valves (175 psi/1270 kpa)

Stainless Steel Pipe System. System No. Submitted By Spec Sect Para Location Date Approved Date TEMPERATURE ( F/ C)

Style 234 Restrained Flexible Single-Gasket Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date

EMCO Corporation Waterworks is not responsible for any errors and discrepencies in the products depicted herein. Information is provided directly

REQUEST PUBLICATION 18.11

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

Victaulic Suction Vibration Isolation Pump Drop Series 337 Korea Only

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

The applicable material specifications for ductile iron and rubber gaskets apply:

Vic -300 Butterfly Valves

Model 7706 Reducing Coupling. Deg. Axial Displacement

COOPLOK Grooved Submittal. Material Specifications

B NPT. Dimensions Inches/millimeters

Section 3. Stainless Steel Series. Shurjoint Stainless Steel Piping Series Grooved Mechanical Couplings. Cast Grooved Fittings.

Victaulic Discharge CBV Vibration Isolation Pump Drop Series 383/383G

Grooved End Fittings. System No. Submitted By Spec Sect Para Location Date Approved Date CARBON STEEL PIPE - GROOVED FITTINGS

*Applies to 6 x 4" No. 650 Reducer only. C to E. No No º Elbow Approx. Wgt. Each Lbs. kg. C to E Inches mm JOB/OWNER CONTRACTOR ENGINEER

SJ-300N. Model SJ-300N-L Butterfly Valve with Lever Handle Max. Working Pressure (CWP)* PSI Bar Dimensions A B C D E in.

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Victaulic Standard Grooved and Advanced Grooved (AGS) Piping System for IPS Steel 2 (DN 50) through 60 (DN1500)

STAINLESS STEEL SYSTEMS

Operators: Lever Handle: 1 1/2 3"/40 80 mm Carbon steel, zinc plated, plastic grip. 4 & 6"/100 & 150 mm Carbon steel, enamel paint

SJ-300N J-04. Model SJ-300N-L Butterfly Valve with Lever Handle

GRINNELL Model B303 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Style Flange Adapter

Approved. Size L H. 3" (76mm) 9-1/2" (241mm) 5-51/64" (147mm) 46. 4" (102mm) 11-1/2" (292mm) 6-45/64" (170mm) 81

Pressfit System for Carbon Steel Pipe

Vic -300 Butterfly Valves

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

Victaulic Specification Power Industry

B U I L D I N G C O N N E C T I O N S T H AT L A S T

GROOVED COUPLINGS - STANDARD FLEXIBLE Model 101

Introduction. We stay ahead of today s evolving market requirements by committing to a program of continued research and development.

General Price List Main effective MAY 13, General Price List. Main

Section 1. Grooved Mechanical Couplings, Flange Adapters & Mechanical Tees

SUBMITTAL PACKAGE FIRE PROTECTION VALVES

Mechanical MATERIAL SPECIFICATIONS. Stainless Steel Housing Specifications. Gasket Specifications. Bolt / Nut Specifications

030/TL 03/01 50M, Copyright 2001, Anvil International $3. 50

Section 8. Copper Series

Valves & Flow Control Components Valves & Flow Control Components

BUTTERFLY VALVE 17 SERIES Gearbox

Hole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole

Worldwide leader in mechanical pipe joining solutions

Series 756 FireLock Dry System Check Valve

Series 751 FireLock European Alarm Check Valve Stations

Series 758 FireLock Actuated System Valve

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

I-731-D/W731-D. Suction Diffuser. Important Installation Information. series 731-D and W731-D

Advantages of Grooved Fittings

GP 300 Grooved Butterfly Valve

Product Submittals for Project

BUTTERFLY VALVE VF-7 Series

Fire Protection Price List. Piping. Systems. Solutions A FP.

ilent Silent Operation Proven Performance Cost Effective Silent Check Valves Check Valve

ALC-3 BUTTERFLY VALVES NOMINAL PRESSURE NOMINAL SIZE MATERIALS CONNECTIONS DESIGN. ANSI Class PN DN

Dura Water Wafer Butterfly Valve

Grooved Piping System for Fire Protection Services

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

70.03 Victaulic Vortex TM

Installation Operation Maintenance

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual

GROOVED FITTINGS FOR COPPER TUBING

F low L ine 72/73 Wafer & Lug Style Sizes 2-24

FireLock NXT Actuated Valve with Preaction Trim. System No. Submitted By Spec Sect Para Location Date Approved Date

HVAC Automatic Balance Valve Index

Section 18 Butterfly Valves

Fire Protection Price List

Ford Fabricated Steel Products

Cast Iron Valves. Product Information. It s all at Albion

Butterfly Valves. Quality Valves at Low Cost

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

Michigan State University Construction Standards. GENERAL-DUTY VALVES FOR PLUMBING PIPING Page

Grooved Piping System for Fire Protection Services

Butterfly Valves T5 (Wafer) and T6 (Lugged) Series

SCOPE OF WORK WASTEWATER TREATMENT PLANT THE WORLD LEADER IN PIPE JOINING SOLUTIONS


UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Cover Page - Butterfly Valves Ordering Information Design Features, 2 to 12 Design Features, 2 to 12 (continued)

Herpteraium SECTION VALVES GENERAL

Transcription:

dapters SEE VICTULIC PULICTION 10.01 FOR DETILS Style 741 Style 741 adapter is designed for directly incorporating flanged components with NSI CL. 125 or CL. 150/PN10 and PN16 or ustralian Standard Table E bolt hole patterns into a grooved pipe system. s 2 12"/50 300 are hinged for easy handling with integral end tabs which facilitate assembly. s 14 24"/350 600 are cast in four (4) identical segments which are interconnected as assembly is completed. The design incorporates small teeth inside the key shoulder I.D. to prevent rotation (excluding 159 size). These teeth should be removed when adapter is utilized with a Victaulic Series 700 grooved end butterfly valve, Schedule 5 pipe or plastic pipe. adapter Style 741 is not recoended for use with Victaulic Series 709 butterfly valves (contact Victaulic for recoendations). They may only be used on one side of Victaulic Series 700 butterfly valve, sizes 2 4"/50 100 fitted with standard or lever-lock handles. adapter must be assembled so it does not interfere with handle operation. Style 743 Style 743 flange-to-groove adapter permits direct connection of NSI Class 300 flanged components into a grooved system. The two-piece, hinged housing engages into the pipe groove and bolts directly to any standard flanged component. The conventional bolt hole pattern allows for easy, fast assembly. Style 743 rotates 360 for proper alignment of bolt holes before tightening. gaskets utilize the Victaulic pressure-responsive design, sealing on the pipe end and directly to the opposing flange face. No standard flange gasket is required. Style 743 is designed to mate with raised-face flanges, but can be used with flat-face flanges by removing the raised projections on the outside face of the flange. STyle 741 2 12" sizes/50-300 MM STyle 741 14 24" sizes/350-600 MM STyle 743 Exaggerated for clarity Exaggerated for clarity notes ecause of the outside flange dimension, should not be used within 90 of one another on a standard fitting. When wafer or lug-type valves are used adjoining a Victaulic fitting, check disc to assure proper clearance. adapters should not be used as anchor points for tie-rods across non-restrained joints. rubber faced flanges, valves, etc., requires the use of a washer. gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. job/owner contractor engineer System No. Submitted y Spec Sect Para Location Date pproved Date 1

dapters material specifications Housing: Ductile iron conforming to STM -536, grade 65-45-12. Ductile iron conforming to STM -395, grade 65-45-15, is available upon special request. Housing Coating: lack enamel. Optional: Hot dipped galvanized and others. Coupling Gasket: (specify choice ) Grade E EPDM EPDM (Green color code). Temperature range 30 F to +230 F/ 34 C to +110 C. Recoended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with NSI/ NSF 61 for cold +86 F/+30 C and hot +180 F/+82 C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade T nitrile Nitrile (Orange color code). Temperature range 20 F to +180 F/ 29 C to +82 C. Recoended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air over +140 F/+60 C and water over +150 F +66 C. Not recoended for hot water services. Services listed are General Service Recoendations only. It should be noted that there are services for which these gaskets are not recoended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recoendations and for a listing of services which are not recoended. Draw olts: 14 24"/350 600 only: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of STM -449 and physical requirements of STM -183. _2

dapters style 741 s 2 12"/50 300 NSI Class 125 and 150 s ctual kpa Load * No. olts olt N Required Maximum / Dimensions / Minimum W Y 2 2.375 300 1,330 2.38 3.41 6.75 6.00 4.75 0.75 3.1 4 5/8 x 2 3/4 50 60.3 2065 5920 60 87 172 152 121 19 1.4 2 1/2 2.875 300 1,950 2.88 3.91 7.87 7.00 5.50 0.88 4.8 4 5/8 x 3 65 73.0 2065 8680 73 99 200 178 140 22 2.1 3 3.500 300 2,885 3.50 4.53 8.29 7.50 6.00 0.94 5.3 4 5/8 x 3 80 88.9 2065 12840 89 115 211 191 152 24 2.4 4 4.500 300 4,770 4.50 5.53 9.87 9.00 7.50 0.94 7.4 8 5/8 x 3 100 114.3 2065 21225 114 141 251 229 191 24 3.4 5 5.563 300 7,290 5.56 6.71 10.90 10.00 8.50 1.00 8.6 125 141.3 2065 32440 141 171 277 254 216 25 3.9 6 6.625 300 10,350 6.63 7.78 11.90 11.00 9.50 1.00 9.9 150 168.3 2065 46060 168 198 302 279 241 25 4.5 165.1 pprox. 6.500 300 9,960 6.50 7.66 11.92 11.00 9.45 1.00 10.0 165.1 2065 44320 165 195 303 279 240 25 4.5 8 8.625 300 17,500 8.63 9.94 14.50 13.50 11.75 1.13 16.6 200 219.1 2065 77875 219 252 368 343 298 29 7.5 10 10.750 300 27,215 10.75 12.31 17.24 16.00 14.25 1.19 24.2 12 7/8 x 4 250 273.0 2065 121110 273 313 438 406 362 30 11.0 12 12.750 300 38,285 12.75 14.31 20.25 19.00 17.00 1.25 46.8 12 7/8 x 4 300 323.9 2065 170270 324 364 514 483 432 32 21.2 WRNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. Total bolts required to be supplied by installer, may be ordered from Victaulic. IMPORTNT NOTES: Style 741 adapters provide rigid joints when used on pipe with standard cut or roll groove and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS -2210 (10K) flanges. Y W _3

dapters style 741 s 50 300 / 2 12" PN10 and PN16 s PN10 s PN16 s ctual ars * p`si Load * olts N No. Req d. ars * Load * olts N No. Req d. / Maximum Dimensions / Minimum W Y 50 60.3 10 2850 16 4561 60 87 177 165 125 20 1.4 4 16 4 16 2 2.375 145 640 230 1025 2.38 3.41 6.97 6.50 4.92 0.79 3.1 76.1 76.1 10 4540 16 7275 76 103 208 185 145 20 2.1 4 16 4 16 3.000 145 1020 230 1635 3.00 4.05 8.19 7.28 5.71 0.79 4.7 80 88.9 10 6210 16 9925 89 115 210 160 22 2.4 3 3.500 145 1395 230 2230 3.50 4.53 8.58 7.87 6.30 0.87 5.4 100 114.3 10 10260 16 16420 114 141 251 229 180 24 3.5 4 4.500 145 2305 230 3690 4.50 5.55 9.88 9.00 7.09 0.94 7.7 139.7 159.0 165.1 139.7 10 15330 16 24520 141 171 274 250 210 24 4.2 5.500 145 3446 230 5512 5.55 6.73 10.79 9.84 8.27 0.94 9.3 pprox. 159.0 10 19800 16 31400 159 187 307 285 240 26 4.5 6.250 145 4450 230 7056 6.25 7.36 12.09 11.0 9.45 1.02 10.0 165.1 10 21400 16 34236 165 195 303 280 240 25 4.5 6.500 145 4811 230 7632 6.50 7.68 11.93 11.00 9.45 1.00 10.0 150 168.3 10 22250 16 35600 168 198 302 279 240 25 4.5 6 6.625 145 5000 230 8000 6.63 7.78 11.89 10.98 9.45 1.00 10.0 200 219.1 10 37690 16 60320 219 252 368 # 342 # 295 # 29 # 7.5 12 20 8 8.625 145 8470 230 13555 8.63 9.94 14.49 13.46 11.65 1.14 16.6 250 273.0 10 58560 16 93695 273 313 437 395 350 27 11.0 12 20 12 24 10 10.750 145 13160 230 21055 10.75 12.31 17.20 15.55 13.78 1.06 24.2 300 323.9 10 82370 16 131810 324 365 478 460 400 32 17.4 12 12.750 145 18510 12 20 230 29620 12 24 12.75 14.31 18.82 18.11 15.75 1.26 38.4 WRNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. # PN16 (/inches): W = 360/14.17; = 340/13.39; Y = 295/11.61; = 30/1.18. PN16 (/inches): W = 438/17.24; = 406/15.98; Y = 355/14.00; = 30/1.18. PN 16 (/inches): W = 478/18.82; = 444/18.11; Y = 410/16.14; = 32/1.26. Total bolts required, to be supplied by installer. olt sizes for conventional flange-to-flange connection. Longer bolts required when flange utilized with wafer-type valves. IMPORTNT NOTES: Style 741 adapters provide rigid joints when used on pipe with standard cut or roll groove and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may only be used on one side of the valve. Contact Victaulic for information on S2129 - Table E; ISO 2084 (PN10); DIN 2532 (PN10) and JIS -2210 (10k) flanges. Y W _4

dapters style 741 s 2 8"/50 200 ustralian Standard Table E s Load * No. olts olt / Dimensions / pprox. ctual kpa N Required Maximum Minimum W Y 50 60.3 1400 4005 60 84 165 152 114 19 1.9 4 5/8 x 2 3/4 2 2.375 203 900 2.38 3.31 6.50 6.00 4.50 0.75 4.1 80 88.9 1400 8700 89 113 200 191 146 24 2.4 4 5/8 x 3 3 3.500 203 1955 3.50 4.44 7.87 7.50 5.75 0.94 5.4 100 114.3 1400 14374 114 131 251 229 178 24 3.3 8 5/8 x 3 4 4.500 203 3230 4.50 5.16 9.87 9.00 7.00 0.94 7.2 165.1 165.1 1400 14374 165 192 303 279 235 25 5.0 6.500 203 6735 6.50 7.56 11.92 11.00 9.25 1.00 11.0 150 168.3 1400 31150 168 192 286 279 235 25 4.5 6 6.625 203 7000 6.63 7.56 11.25 11.00 9.25 1.00 9.9 200 219.1 1400 52777 219 247 368 343 292 29 5.7 8 8.625 203 11860 8.63 9.72 14.50 13.50 11.50 1.12 12.5 WRNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. Total bolts required to be supplied by installer, may be ordered from Victaulic. IMPORTNT NOTES: Style 741 adapters provide rigid joints when used on pipe with standard cut or roll groove and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS -2210 (10K) flanges. Y W _5

dapters style 741 s 14 24"/350 600 # NSI Class 125 and 150 s ctual kpa Load * ssembly olts N No. Req. No. Req. Draw olts / Dimensions / T V W Y 14 14.000 300 46,180 14.00 16.39 19.38 0.94 24.50 21.00 18.75 2.50 62.0 12 1 x 4 1/2 4 5/8 x 3 1/2 350 355.6 2065 205500 356 416 492 24 622 533 476 64 28.1 16 16.000 300 60,300 16.00 18.39 21.50 0.94 27.12 23.50 21.25 2.50 79.0 16 1 x 4 1/2 4 5/8 x 3 1/2 400 406.4 2065 268335 406 467 546 24 689 597 540 64 35.8 18 18.000 300 76,340 18.00 20.00 22.25 1.00 29.00 25.00 22.75 2.75 82.3 16 1 1/8 x 4 3/4 4 3/4 x 4 1/4 450 457.0 2065 339700 457 508 565 25 737 637 578 70 37.3 pprox. 20 20.000 300 94,250 20.00 22.50 25.00 1.00 31.50 27.50 25.00 2.75 103.3 20 1 1/8 x 5 1/4 4 3/4 x 4 1/4 500 508.0 2065 419400 508 572 635 25 800 699 635 70 46.9 24 24.000 300 135,700 24.00 27.75 29.00 1.00 36.00 32.00 29.50 3.00 142.0 20 1 1/4 x 5 3/4 4 3/4 x 4 1/4 600 610.0 2065 603865 610 705 737 25 914 813 749 76 64.4 WRNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. Total bolts required to be supplied by installer, may be ordered from Victaulic. olt sizes for conventional flange-to-flange connection. Longer bolts required when utilized with wafer-type valves. Draw bolts supplied with 14 24 /350 600 adapters. # For cut groove systems only. For 14 24 /350 600 roll groove systems, GS (dvanced Groove System) products are used. Style 741 is not compatible with the GS system. V Y T W _6

dapters style 743 Grooved pipe adapter to NSI Class 300 flanges ctual kpa Load * No. olts olt/nut N Required Maximum / Dimensions / Minimum W Y 2 2.375 720 3,190 2.38 3.41 7.70 6.50 5.00 0.93 4.8 8 5/8 x 3 50 60.3 4960 14200 60 87 196 165 127 24 2.2 2 1/2 2.875 720 4,670 2.88 3.91 8.61 7.50 5.88 1.06 7.4 8 3/4 x 3 1/4 65 73.0 4960 20780 73 99 219 191 149 27 3.4 3 3.500 720 6,925 3.50 4.53 9.48 8.25 6.63 1.18 9.1 80 88.9 4960 30815 89 115 241 210 168 30 4.1 4 4.500 720 11,445 4.50 5.53 11.35 10.00 7.87 1.31 15.3 8 3/4 x 3 3/4 100 114.3 4960 50930 114 141 288 254 200 33 6.9 5 5.563 720 17,500 5.56 6.72 12.31 11.00 9.25 1.43 17.7 8 3/4 x 4 125 141.3 4960 77875 141 171 313 279 235 36 8.0 6 6.625 720 24,805 6.63 7.78 13.77 12.50 10.63 1.50 23.4 12 3/4 x 4 1/2 150 168.3 4960 110380 168 198 350 318 270 38 10.6 8 8.625 720 42,045 8.63 9.94 16.68 15.00 13.00 1.68 34.3 12 7/8 x 4 3/4 200 219.1 4960 187100 219 252 424 381 330 43 15.6 10 10.750 720 65,315 10.75 12.31 19.25 17.50 15.25 1.93 48.3 16 1 x 5 1/4 250 273.0 4960 290650 273 313 489 445 387 49 21.9 12 12.750 720 91,880 12.75 14.31 22.25 20.50 17.75 2.06 70.5 16 1 1/8 x 5 3/4 300 323.9 4960 408870 324 363 565 521 451 52 32.0 WRNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. Style 743 must be ordered as a factory assembly when connected to a Victaulic fitting or valve. Contact Victaulic for details. Total bolts required to be supplied by installer, may be ordered from Victaulic. pprox. Remove to mate to flat-faced flanges. Y W _7

dapters dapter Notes 1. The Style 741 (2 12"/50 300 ) design incorporates small teeth inside the key shoulder I.D. to prevent rotation. These teeth should be removed when adapter is utilized with a Victaulic Series 700 grooved end butterfly valve, Schedule 5 pipe or plastic pipe. adapter Style 741 may only be used on one side of Victaulic Series 700 butterfly valve, sizes 2 4"/50 100 fitted with standard or latch-lock handles. 2. adapter must be assembled so it does not interfere with handle operation. ecause of the outside flange dimension, adapter should not be used within 90 of one another on a standard fitting. When wafer or lug-type valves are used adjoining a Victaulic fitting, check disc to assure proper clearance. 3. adapters should not be used as anchor points for tie-rods across nonrestrained joints. rubber faced flanges, valves, etc. requires the use of a washer. 4. rea - noted in the above drawing must or deformities of any type for 5. adapter gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. 6. hinge points must be oriented approximately 90 to each other when mated. 7. Washers: adapters require a smooth hard surface at the mating flange face for Some applications for which the adapter is otherwise well suited do not provide an adequate mating surface. In such cases, it is recoended that a metal (Type F phenolic for Style 641 with copper systems) Washer be inserted between the adapter and the mating flange to provide the necessary sealing surface. Typical applications where a Washer should be used are:. When mating to a serrated flange: a flange gasket should be used adjacent to the serrated flange and then the Washer is inserted between the adapter and the flange gasket.. When mating to a wafer valve: where typical valves are rubber lined and partially rubber faced (smooth or not), the Washer is placed between the valve and the adapter. C. When mating a rubber faced flange: the Washer is placed between the flanges and the rubber faced flange. D. When mating WW cast flanges to IPS flanges: the Washer or Transition Ring is placed between two adapters with the hinge points oriented 90 to each other. If one flange is not a adapter (e.g., flanged valve), then a flange gasket must be placed adjacent to that flange and the Washer inserted between the flange gasket and the adapter. Transition rings rather than Washers must be used when mating Style 741 to Style 341 dapters in sizes 14 24"/350 600. E. When mating to components (valves, strainers, etc.) where the component flange face has an insert: follow the same arrangement as in pplication 1. When ordering Washers, always specify product style (Style 741, 743, 341, 641, 994) and size to assure proper Washer is supplied. _8

dapters general notes Style 741 and 743 adapters provide rigid joints when used on pipe with standard roll or cut groove and consequently allow no linear or angular movement at the joint. warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. note This product shall be manufactured by Victaulic or to Victaulic specifications. ll products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the I-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at. For complete contact information, visit 1534 rev M Updated 2/2011