TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

Similar documents
TECHNICAL DATA. Trimpac 244a. April 15, 2011

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

TECHNICAL DATA. Trimpac 249a. September 16, 2013

TECHNICAL DATA 1-1/2 (dn40)

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Wet pipe low flow foam/water manifold system

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

TECHNICAL DATA. Q= C v P S. Table 1 - Valve Part Numbers and Specifications

Q= C v P S. Flow control valve Model j-2 Halar coated

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

TECHNICAL DATA 2-1/2-8 (dn65 - dn200)

TECHNICAL DATA. Q= C v P S

TECHNICAL DATA OBSOLETE. Inlet Type Outlet Type in mm. Thread Thread in. ANSI B Flanged Flanged in.

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL H-2 HALAR COATED 2 (DN50) - 6 (DN150)

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

TECHNICAL DATA P S. Q= Cv MODEL E-2 DELUGE VALVE HALAR COATED ANGLE STYLE

Section R Foam Systems

Section R Foam Systems

Section N Deluge Systems

Section P Flow Control and Pressure Regulation

Section O Preaction Systems

Section P Flow Control and Pressure Regulation

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Section M Dry Pipe Systems

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

TECHNICAL DATA CAUTION

DELUGE VALVE DATA SHEET

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

TotalPac 3 Deluge system Pneumatic release

TECHNICAL DATA OBSOLETE

Worldwide Contacts.

Section L Wet Pipe Systems

Technical Data. UL Listing is based on the following criteria:

1-1/2 Inch (DN40) 9 lb (4,1 kg) Groove Groove 1 8 lb (3,6 kg) Flange Groove 1 N/A N/A. Flange Flange N/A N/A

DV-5A Automatic Water Control Valve Remote-Resetting Deluge Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Sludge Dewatering and Odor Control at Plant 1 CONFORMED

TotalPac 3 Double interlock Preaction, Electric/Pneumatic release Remote controlled system

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

TotalPac 3 Non interlock Preaction system Pneumatic release

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA OBSOLETE

BERMAD Fire Protection

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Remote controlled system

TotalPac 3 Non interlock Preaction, Electric release Remote controlled system

TotalPac 3 Deluge, Electric release Remote controlled system

TECHNICAL DATA. Table Standard Materials

Solenoid valve. Solenoid Coil

Deluge Pressure Reducing Valves. Model 68 DE\ EL\ PORV\ PR. Electrically and Pneumatically Actuated, Pressure Reducing, Remote-Reset, Deluge Valve

Instructions for Installation, Operation, Care and Maintenance

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

Combi2 TTW Models (CSW2TW, CDW2TW)

In-Line Balanced Pressure Proportioner (ILBP) Proportioning Devices Model KBP

SHORTER. LIGHTER. MORE VERSATILE. 1 VALVE 10 TRIM CONFIGURATIONS 4" AND 6" MODEL RCW WATER CONTROL VALVE FOR DRY, PREACTION AND DELUGE APPLICATIONS

TECHNICAL DATA OBSOLETE

PRESSURE RELIEF VALVE CONTROL VALVE

Pressure Relief Valves Series. Consolidated Safety Valve

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC

Hydraulic Concentrate Control Valve

Installed on the pump suction, CRISPIN Foot Valves prevent the

TECHNICAL DATA OBSOLETE

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Model DDX Deluge Valves 4" (100 mm), 6" (150 mm) and 165 mm Sizes

Instructions for Installation, Operation, Care and Maintenance

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

Model DDX Deluge Valve 8 (200mm) Features

Horizontal Pre-Piped Bladder Tanks with Proportioner

Features 1. Differential Latch-type, lightweight, dependable

TotalPac 3 Firecyle III Wet pipe Remote controlled system

Vertical Pre-Piped Bladder Tanks with Proportioner

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

Model MTB-ASME Horizontal Pre-Piped Bladder Tanks

HERZ-Motorised flow controler

TotalPac 3 Double interlock Firecyle III Preaction Remote controlled system

HORIZONTAL BLADDER TANKS

Installation Guide D. Three-Way/Two-Way Transfer Valve P29513, P29514

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

Waterous Midship Pump and Accessory Weight Chart

Sl. No. Description Pages

Accessories. Section Outline

Series 758 FireLock Actuated System Valve

TEMPERATURE REGULATORS W91/W94 Series

SECTION METERS AND GAGES FOR PLUMBING PIPING

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division

P200 Pressure Regulator

Residential & Light Duty Commercial Gas Atmospheric Vent High Input Models

AUTOMATIC AIR VALVES For potable water

Through-The-Wall TTW 1,TTW 2 Energy Saver Models

HD Series. Pilot-Operated Regulating Valves. HD Series features & benefits

Easy Riser swing check valve Models E-1 & F-1

model E Spray nozzles vk810 - vk817

Special Kv available. Classification according pressure equipment Directive, 2014/68/UE

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

Transcription:

April 15, 2011 Deluge Trim 227a Order Deluge Valve Separately This Trim Chart is for use with the following Viking Trim Sets Valve Size Galvanized Trim Part No. Brass Trim Part No. 3 (DN80) 14631-1 14631-2 4 (DN100) 14632-1 14632-2 6 (DN150) 14633-1 14633-2 This Trim is for use with the following Release Module Trim Kits Release Type Galvanized* Brass** Electric 10830 10832 Pneumatic 10809 10811 Figure 1 Electric/ Pneumatic Pneumatic/ Pneumatic 12661-1 12661-2 12662-1 12662-2 * Standard Trim sets for Model E Deluge Valves consist of galvanized nipples and fittings. **Refer to Technical Data describing the Halar Coated Deluge Valve and the Viking Foam Systems Engineering Design Data book for applications where brass trim is recommended. Note: Nipple lengths for brass trim may vary from those shown on this Trim Chart. Notes: For use with Trim Charts on Pages 227b - d Note: When viewing this data page online, blue text represents hyperlinks and will open the appropriate data page when clicked. General Notes: Valve must be trimmed as shown. Any deviation from trim size or arrangement may affect the proper operation of the valve. All pipe, 3/4 (20 mm) and smaller, shall be galvanized steel except when other materials are specified in the Technical Data for the Halar Coated Deluge Valve or when other materials are specified in the Viking Foam Systems Engineering and Design Data book. When Model E Deluge Valves are used on pre-mixed Foam Systems, trim piping must be of black steel pipe with cast iron or malleable iron fittings unless otherwise specified in the Technical Data for the Halar Coated Deluge Valve or the Viking Foam Systems Engineering and Design Data book. Dimensions in parentheses are millimeter and may be approximations. Note 1: 1/2 (15 mm) NPT plugged outlet provided for connecting certain optional components and associated trim. Note 2: Release System connection. Viking Deluge and Flow Control Valves are compatible with hydraulic, pneumatic, and electric release systems. A Pneumatic Actuator is required on all Viking Deluge Valves and Flow Control Valves equipped with Pneumatic Release Systems. Note 3: Alarm Connections: Connect alarm line piping to 3/4 (20 mm) NPT outlet. When using a Water Motor Alarm, a strainer is required. 1/2 (15 mm) NPT outlet is for electric Alarm Pressure Switch. Note 4: Optional non-interruptible connection for Alarm Pressure Switch to activate electric alarm panel. Note: After the Deluge Valve trips, this location cannot be shut off. Alarms may operate until the outlet chamber of the deluge valve is de-pressurized below the set point of the Alarm Pressure Switch. Note 5: Viking Drain Check Valve is manufactured with a 0.067 (1.7 mm) orifice to allow alarm line to drain. Do not substitute. Check label for proper orientation. Note 6: Inlet side of PORV is connected to the top chamber of the deluge valve. Inlet of PORV should be facing up. Outlet goes to open drain. Form No. F_012194 Revised page replaces page 227a-e, dated August 1, 2008. (New PORV in Figures 1-5 and added dimensions to Figures 5a - 5c.)

Deluge Trim 227b April 15, 2011 Refer to page 227a for General Notes and Notes 1 through 6. Figure 2 3 Deluge Valve Trim Order Deluge Valve Separately

April 15, 2011 Deluge Trim 227c Refer to page 227a for General Notes and Notes 1 through 6. Figure 3 4 Deluge Valve Trim Order Deluge Valve Separately

Deluge Trim 227d April 15, 2011 Refer to page 227a for General Notes and Notes 1 through 6. Figure 4 6 Deluge Valve Trim Order Deluge Valve Separately

April 15, 2011 Deluge Trim 227e Figure 5a: Installation Dimensions - 3 (DN80) Valve

Deluge Trim 227f April 15, 2011 Figure 5b: Installation Dimensions - 4 (DN100) Valve

April 15, 2011 Deluge Trim 227g Figure 5c: Installation Dimensions - 6 (DN150) Valve

THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_012194 Revised page replaces page 227a-e, dated August 1, 2008. (New PORV in Figures 1-5 and added dimensions to Figures 5a - 5c.)