a WARNING Allen-Bradley Parts K-Frame Circuit Breaker Instruction Leaflet for Alarm Switch and Alarm /Auxiliary Switch Combination Bul.

Similar documents
Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton

I.L. 29C184A File WARNING

I.L. 29C121A WARNING 1. INTRODUCTION. Maximum Freq. Maximum Dielectric Voltage Current Withstand (V) (A) Voltage (V)

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Installation Instructions for the 14" Walking Beam Interlock for L-Frame and MDL-Frame Series C Circuit Breakers and Molded Case Switches

Cutler-Hammer. Installation Instructions for the ND OPTIM 550 PowerNet and/or Zone Interlock Accessories (ICK 550N, ZGK550N, ZGPK550N) I.L.

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

N-frame Circuit Breaker

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

! WARNING I.L D WARNING GENERAL INFORMATION

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

A WARNING. Installation Instructions for KD, HKD, KDC, CKD, CHKD Circuit Breakers I.L. 29C092C

Installation Instructions for TMQV Circuit Breakers and Molded Case Switches

Installation Instructions for NW, HNW, and NWC Circuit Breakers and N-frame Series C Molded Case Switches

www. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING

www. ElectricalPartManuals. com ltciil Cutler-Hammer A WARNING

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

Digitrip RMS and Digitrip OPTIM Trip Units Used with R-Frame Circuit Breakers

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

CM52 Network Protector with Arc Flash Reduction Module

Digitrip Retrofit System for BBC LKD 8 Breakers

www. ElectricalPartManuals. com Digitrip Retrofit System for the Westinghouse DA-50 IL 33-DAC-2 WARNING

Digitrip Retrofit System for Siemens-Allis RLX-1600 Breakers

2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

WARNING. Instructions for Combination Bypass Isolation and Transfer Switches Amps I.L A FILE APPLICATION SAFETY PRACTICES

Installation Instructions for R-Frame Circuit Breakers and Molded Case Switches

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

Two-way cable interlock kit for Magnum drawout circuit breakers

Installation Instructions Electric Heaters 5 20 kw

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Installation Instructions

Instruction Bulletin Dual Sub-Feed Circuit Breaker and Adapter Kit Installation onto an NQ Panelboard Class 1640

Installation Instructions for Series C F-Frame 310+ Electronic Circuit Breaker Types FDE, HFDE, FDCE

Installation Instructions For Motor Control Center (MCC) Units

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

E.S.P. Embedded Sensing Probes for Motor Brushes

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

Florham Park, NJ USA Call (ASCO) for sales or service

Instruction Bulletin NF Panelboard Dual Sub-Feed Circuit Breaker Adapter Kit Installation onto an NF Panelboard Class 1670

MCCB Accessories to suit AF

Installation Instructions Electric Heaters 5 20 kw

Advanced Test Equipment Rentals ATEC (2832)

Electrically Held to Mechanically Latched Contactor

Digitrip Retrofit System for Allis-Chalmers G-25 Breakers

Installation Manual. E-design A Transfer Switches A

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Florham Park, NJ USA Call (ASCO) for sales or service

Manual Motor Starters. Meta-MEC

3ATS & 3NTS J-design 600 A 3ADTS & 3NDTS A Transfer Switches. Installation Manual. Installation A DANGER. Table of Contents WARNING

CAMSHAFT TIMING CHAIN, SPROCKET, AND TENSIONER REPLACEMENT

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

Installation Instructions for Series 3100V Low Level Indicator

Q-Frame Main Circuit Breaker (225 A Maximum) and Adapter Kit Installation onto an NQ Panelboard Class 1640

Installation Instructions

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

ibusway for Data Center

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO)

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

RBR circuit breaker - Remote operated

600 D 220 E 230 J Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

SERIES 73 ELECTRIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Type DTU De-energized Tap Changer Application, Installation & Selection Guide. IL A Instruction Leaflet Page 1 September, 2003

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

Installing Power Components

3-way multi-family drawout cable interlock kit - type 32 - RF

' '!' D Model, 70 to 250 Amperes. W Model, 63 to 250 Amperes. www. ElectricalPartManuals. com

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Operator s Manual Series ADTS Automatic Delayed Transition Transfer Switches, amps

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Technical Manual. DLM Module. This manual should remain with the unit.

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Two-way cable interlock kit for Magnum fixed circuit breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

920 Remote Control Switches

SecoVac * Ground & Test Device

Installation Instructions for Replacement Mechanism Kit

EXTREME R MOTOR OWNER'S MANUAL

2000 Dodge Durango ACCESSORIES & EQUIPMENT' 'Power Windows - Dakota & Durango 2000 ACCESSORIES & EQUIPMENT. Power Windows - Dakota & Durango

SAVE THESE INSTRUCTIONS

Owner's/Installation Manual

Transcription:

K-Frame Circuit Breaker Instruction Leaflet for Alarm Switch and Alarm /Auxiliary Switch Combination Bul. 140U a WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAIN- TENANCE ON EQUIPMENT WHILE IT IS ENERGIZED. DEATH, SEVERE PERSONAL INJURY, OR SUBSTAN- TIAL PROPERTY DAMAGE CAN RESULT FROM CON- TACT WITH ENERGIZED EQUIPMENT. ALWAYS VERIFY THAT NO VOLTAGE IS PRESENT BEFORE PROCEEDING WITH THE TASK, AND ALWAYS FOL- LOW GENERALLY ACCEPTED SAFETY PROCE- DURES. ALLEN-BRADLEY IS NOT LIABLE FOR THE MISAP- PLICATION OR MISINSTALLATION OF ITS PROD- UCTS. The user is cautioned to observe all recommendations, warnings, and cautions relating to the safety of personnel and equipment as well as all general and local health and safety laws, codes, and procedures. The recommendations and information contained herein are based on Allen-Bradley experience and judgement, but should not be considered to be all-inclusive or covering every application or circumstance which may arise. If any questions arise, contact Allen-Bradley for further information or instructions. 1. INTRODUCTION Fig. I- 1. Alarm (Signal)/iockout Switch Installed in K-Frame Circuit Breaker switch has a make (alarm) and a break (lockout) contact; it is mounted so that the switch actuator arm is controlled by the circuit breaker operating mechanism cradle. The actuator arm extends past the operating mechanism cradle; therefore, only one plug-in module containing an ASL switch or switches can be used in a circuit breaker. General Information The alarm (signal)/lockout switch (ASL switch) is attached to a plug-in module available in the following combinations (see Fig. 1-1): One or two ASL switches One auxiliary switch and one ASL switch The plug-in module is mounted in slots in the top of the trip unit and occupies the accessory mounting cavity in the circuit breaker frame. The ASL switch provides remote signaling and interlocking when the circuit breaker trips; it consists of one or two single-pole, double-throw (SPDT) switches. Each SPDT When the circuit breaker is in the ON or OFF position, the cradle holds the make contact open and the break contact closed. When the circuit breaker is in the tripped position, the make contact is closed and the break contact is open. Any type of trip operation (for example, automatic trip, shunt trip, or undervoltage release) actuates the ASL switch. The auxiliary switch in the combination accessory indicates circuit breaker contacts status and is used for remote signaling and system interlocking purposes. Each SPDT switch has one a and one b contact. The plug-in module mounts in the accessory mounting cavity of the circuit breaker so that the switch actuator arm rests against the molded crossbar. When the molded crossbar is in the contacts-closed position, the a contact of each SPDT switch is closed and the b contact is open. When Allen-Bradley Parts

Page 2 the molded crossbar is in the tripped or contacts-open position, the (a contact is open and the b contact is closed. Table 1-l lists electrical rating data for the ASL switch and auxiliary switch. Table l-1. Alarm (Signal)/Lockout Switch and Auxiliary Switch Electrical Rating Data@@@ Maximum Freq. Voltage P) 600 50/60 Hz 125 DC 250 DC Maximum Dielectric Current Withstand (A) Voltage (V) 6 2500 0.50 0.250 0 Endurance - 1000 electrical operations plus 5000 mechanical operations 0 Pigtail wire size - No. 18 AWG (0.82 mm2) 0 Terminal block is listed for use with one or two No. 18 to No. 14 AWG solid or stranded copper wire. Torque is 7 lb-in (0.8 N.m) @ Non-inductive load This Instruction Leaflet (IL) gives detailed procedures for installing the ASL switch and ASL switch/auxiliary switch combination (accessory combination.) 2. INSTALLATION Note: The ASL switch(es) and accessory combination can be field-installed in K-Frame circuit breakers. Before attempting to install the ASL switch or accessory combination, check that the catalog number is correct and the rating of the accessory(s) satisfies the job requirements. The ASL switch and accessory combination, as shown in kit form in Fig. 2-1, can be installed in the right or left accessory mounting cavity of a 2-,3-, or 4-pole circuit breaker. An ASL switch or accessory combination must be installed in the circuit breaker before the circuit breaker is mounted in an electrical system. To install the ASL switch or accessory combination, perform the following procedures: Note: A circuit breaker that is mounted in an electrical system must be removed to install the accessory. To ensure correct accessory installation, the circuit breaker must be placed on a horizontal surface. Depending on the model ordered, connections for the ASL switch and auxiliary switch contacts are in one of four forms. The standard wiring configuration is pigtail leads exiting the rear of the base directly behind the accessory. Optional configurations include a terminal block mounted on the same side of the base as the accessory, leads exiting the side of the base where the accessory is mounted, and leads exiting the rear of the base on the side opposite the accessory, The 18-inch long pigtail leads are color coded for identification; identification labels are provided for pigtail leads and terminal block points. For allowable locations of all accessories, refer to Product Selection Guide. Note: No more than three pigtail leads can be routed through the rear trough in the circuit breaker base. When the walking beam interlock is used with the circuit breaker, the rear trough cannot be used for accessory pigtail leads.

Page 3 General Installation a WARNING BEFORE REMOVING A CIRCUIT BREAKER INSTALLED IN AN ELECTRICAL SYSTEM, MAKE SURE THE CIRCUIT BREAKER IS SWITCHED TO THE OFF POSITION AND THERE IS NO VOLTAGE PRESENT WHERE WORK IS TO BE PERFORMED. SPECIAL ATTENTION SHOULD BE PAID TO REVERSE FEED APPLICATIONS TO ENSURE NO VOLTAGE IS PRESENT. THE VOLTAGES IN ENER- GIZED EQUIPMENT CAN CAUSE DEATH OR SEVERE PERSONAL INJURY. Note: Steps 2-1 through 2-11 and 2-14 through 2-19 are for general installation and apply to the ASL switch and the accessory combination. Step 2-12 covers installation of the ASL switch. Step 2-13 covers installation of the accessory combination. For new circuit breaker installation, the trip unit must be installed in the circuit breaker before attempting to install an ASL switch or accessory combination. Note: Molded case switch trip units are not equipped with a Push-to-Trip button. For molded case switches, omit step 2-2. 2-2. Press PUSH-TO-TRIP button to trip operating mechanism. 2-3. Disconnect and remove circuit breaker from installation and terminal connections. 2-4. Remove cover screws and cover. Note: To install accessory, circuit breaker must be in tripped position. 2-5. For high instantaneous trip-type molded case switches, locate recessed hole in either of the trip unit outer poles. (Fig 2-2). Push a fine point implement in one hole to trip the molded case switch. a WARNING DO NOT RESET CIRCUIT BREAKER AFTER MOLDED HANDLE IS REMOVED. CRADLE RESET PIN MAY FLY OUT AND CAUSE INJURY IF MECHANISM IS TRIPPED. 2-7. Remove handle-retaining screws and molded handle from handle arm. (See Fig. 2-3.) 2-8. Remove interphase barrier between center pole and pole in which accessory is to be mounted. (See Fig. 2-3.) 2-9. Install replacement interphase barrier supplied with kit in base. (See Fig. 2-3.) Note: Before the next step, be sure that replacement interphase barrier has been installed in correct accessory cavity side, and that cradle reset pin has not fallen out of retaining-slot in handle arm. 2-10. Put molded handle on handle arm, and install retaining screws. Note: For all combinations of accessories, leads from inner accessory switch must go to the wiring 2-1. A/arm (Signal)/Lockout Switch Kit trough nearest line end of circuit breaker. For a double combination, leads from the outer accessory switch must go to center trough. 2-l. Switch circuit Allen-Bradley breaker to OFF position. Parts

Page 4 Rear Exiting Leads Preferred Fig. 2-2. Terminal Block Recessed Hole Location in K-Frame Trip Unit Note: For an accessory having rear or opposite-side exiting pigtail leads, thread leads through trough in side of base before attempting to insert mounting bracket. Pigtail leads exiting in this manner should be eased through trough as mounting bracket is inserted into trip unit retaining slots. Side Exiting Leads Opposite-Side Exiting Leads Fig. 2-4. Accessory Wiring Options 2-11. Route wiring to meet installation requirements. (See Fig. 2-4.) ASL Switch Module Position Actuator Ar m Under Cradle Actuator Arm Fig. 2-3. Interphase Barrier Replacement Fig. 2-5. Alarm (Signal)/Lockout Switch Installation

Page 5 a CAUTION PIGTAIL WIRES SHOULD BE FORMED AND ROUTED TO CLEAR ALL MOVING PARTS WHEN ACCESSORY IS PROPERLY INSTALLED. PIGTAIL LEADS COULD BE DAMAGED IF IN CONTACT WITH MOVING PARTS. Alarm (Signal)/Lockout Switch Installation 2-12. Insert ASL switch as described in the following steps: a. Put tip of actuator arm through slot in replacement interphase barrier and under cradle. (See Fig. 2-5.) Crrcult Breaker -- ---- Handle Arm (Must Be Positioned Under, And Operated By the Cradle) ASL Switch Mounting Bracket Trip Unit b. Turn ASL switch mounting bracket to line up with slots in trip unit. c. Slide ASL switch mounting bracket into slots until retaining clip snaps into trip unit. Make sure ASL switch actuator arm is positioned as shown in Fig. 2-6. For terminal block assemblies, slide terminal block into mounting slot on side of base as plug-in module is being positioned. d. If required, complete routing of leads to opposite-side through rear wiring trough. e. For double ASL switch with pigtail leads, attach wire marking labels to bundle of three leads for each switch. (Markers designated 1 and 2 are provided.) Accessory Combination Installation 2-l 3. Install accessory combination switch as described in the following steps: a. Put tip of ASL switch actuator arm through slot in replacement interphase barrier and under cradle (Fig. 2-7). Make sure ASL switch operating arm is positioned as shown in Fig. 2-6. b. Turn accessory combination mounting bracket to line up with slots in trip unit. Fig. 2-6. Fig. 2-7. [Interphase Barrier Omitted for Clarity) Alarm (Signal)/Lockout Switch Actuator Arm Location Cradle 1 Accessory Combination Module - Position ASL Switch Actuator Arm Under Cradle L r six I ASL Switch ASL Switch Show D&ail) Arm Slot In Replacement Interphase Barrier Accessory Combination Ins talla tion to Allen-Bradley Parts

Page 6 c. Slide accessory combination mounting bracket into slots until retaining clip snaps into trip unit. Be sure that auxiliary switch operating arm is between accessory operating projection on the molded crossbar and arc extinguisher (Fig. 2-8). For terminal block assemblies, slide terminal block into mounting slot on side of base as accessory combination is being positioned. General Installation a CAUTION WHEN INSTALLING CIRCUIT BREAKER COVER, MAKE SURE THAT ALL INTERNAL PARTS ARE IN PLACE: r Trip Unit Auxiliary Switch Mounting Bracket. SLIDING HANDLE BARRIERS ARE INSTALLED SO THAT THE HANDLE OPENING IS ALIGNED WITH THE HANDLE. PIGTAIL LEADS ARE CLEAR OF COVER. - Breaker Handle WHEN REMOVED AND REINSTALLED, THREAD- FORMING SCREWS TRY TO REFORM THE THREADS IN THE CIRCUIT BREAKER BASE. CARE SHOULD BE TAKEN EVERY TIME A THREAD-FORMING SCREW IS USED TO ENSURE THAT THE SCREW STARTS IN THE ORIGINAL THREADS. DAMAGED THREADS CAN RESULT IN IMPROPER CIRCUIT BREAKER COVER RETENTION. Ctip Auxiliary Switch Operating Arm Accessory Operating g Projection 2-14. With circuit breaker handle in TRIPPED position and accessory pigtail leads (if used) routed as required, install circuit breaker cover. Secure with pan-head screws followed by thread-forming screws, as shown in Fig. 2-10. Fig. 2-8. Auxiliary Switch Operating Arm Location d. If required, complete routing of leads to opposite-side through rear wiring trough. e. For ASUauxiliary switch accessory combination with pigtail leads, attach wire marking labels to bundle of three leads for each switch. (Markers designated A and B are provided.) 2-15. Place accessory labels (supplied with kit) on circuit breaker. (See Fig. 2-11.) Note: Accessory labels show connection diagram for ASL switch and/or auxiliary switch contacts. Pigtail leads are color coded red, black, and blue. Be sure that wire marking label is attached correctly to leads and agrees with related leads at accessory. 2-16. Test ASL switch by connecting continuity tester or ohmmeter across pigtail leads or terminal block connections. Check continuity as follows: a. Circuit breaker handle OFF - Check that make contact(s) are open and break contact(s) are closed.

Page 7 Pigtail Leads ASL Switch Blue Auxiliary Red Switch 1 Make T (Alarm) a Leads Are Bundled and Tagged B Leads Tagged Are Bundled and A Terminal Block Blue Red --CBreak - L o +(Lockout) - Red +t b Blue - -ḇ ASL Switch Auxiliary Switch Fig. 2- IO. Cover Screw lnstalla tion Positions Modification r Label Fig. 2-12. Alarm (Signat)lLockout Switch - Auxiliary Switch Connection Diagram b. Circuit breaker handle ON - Check that make contact(s) are open and break contact(s) are closed. C. Press PUSH-TO-TRIP button - Check that make contact(s) are closed and break contact(s) are open. d. If ASL switch fails test, make sure that module is properly seated in trip unit slots. If problem persists. contact Allen-Bradley. Terminal Black 2-17. Test auxiliary switch (when supplied). Connect continuity tester or ohmmeter across pigtail leads or terminal block connections. Check continuity as follows: I Terminal Block Connection Diaaram Label (When Used) Pigtail Lead Connection Diagram Label (When Used) Fig. 2- I I. Preferred Mounting Locations for Accessory Nameplate Labels a. Circuit breaker handle OFF - a contact - open b contact - closed. b. Circuit breaker handle ON - a contact - closed b contact - open. Allen-Bradley Parts

Page 8 c. Press PUSH-TO-TRIP button - la contact - open b contact - closed. d. If auxiliary switch fails test, make sure that module is properly seated in trip unit slots. If problem persists, contact Allen-Bradley. 2-1 8. Install circuit breaker 2-19. Connect accessory leads as required. (See Fig. 2-12.) Allen-Bradley assumes no responsibility for malfunctioning accessories installed by the customer.