Room thermostats type series TRM

Similar documents
Rod thermostats (without immersion tube)

TER. Thermostats for Industrial Applications. Switching range: C to C. Housing material: aluminium. Capillary tube: copper

Terminal Boxes in Stainless Steel SLS**.T

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

ATEX/IECEx RTD temperature probe

Product information. Temperature. Thermostats Temperature transmitters Hygrostats CERTIFIED ISO 9001 ISO PED 97/23EC

Position Switches Series 8074/2

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

The filling level sensors are designed in accordance to the following standards

IECEx Certificate of Conformity

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Compact differential pressure switch Models DC, DCC

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Pneumatic control unit for decentralized automation of ELEMENT process valves

Position Switches Series 8060/2

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Mini temperature switch Stainless steel switch enclosure Model TXS

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Modular Explosion Proof Brakes. IECLine rev 0

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

Level limit switch Series RF 3000 Selection list

Thermocouple For additional thermowell Model TC10-B

Temperature controls, Type RT

Load disconnect switch Series 8146/5-V11

Type 4746 Electric or Pneumatic Limit Switch

Contact Dial Thermometer

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Sensor boxes SRBE Key features and product range overview

Flap-Type Flow Meter Prall

ExBin-P Pressure switches 5 Pa Pa

English copy version 2010/REV04 PISTON PRESSURE SWITCH DS-117 / DS-112

Pressure and temperature controls, Type CAS

Position Switches Series 8070/2

CCAI, CCAIF, CCAIF..H

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Direct-acting 3/2 way plunger valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Compact temperature switch Model TCS

IECEx Certificate of Conformity

Ex Pressostat EXPK 944/947/953. Applications. Features

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Operating Instructions

Flameproof Level Sensor (Flameproof F/S FP)

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Integrated Control modules

Pressostats and thermostats CAS

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Safety Switches Series 8537

Components and parts list 4 5. Data sheet sensor SJ 3,5-SN 5 6. Cable gland 6.1 Cable gland nickel-plated 6.2 Cable gland stainless steel

ELECTRIC MULTI-TURN ACTUATORS for valve automation in the oil & gas industry with high torque requirements

INSTRUCTION MANUAL (ATEX / IECEx)

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Pressure Control, Differential Pressure Control, Type RT

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

INSTRUCTION MANUAL (ATEX / IECEx)

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

11 Control Panels, Distribution Panels and Components

Products Temperature, Control, Monitoring

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

Product specification

Pressure controls and thermostats, type KPS

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Differential pressure gauge Model , copper alloy Model , stainless steel version

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications

OPTISWITCH 4000/5000. Vibration level switches for liquids

Product Catalogue. Electromechanical controllers REL

Contact dial thermometer

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

10 Load and Motor Switchgear

Control Buttons / Switches for Panel Mounting Series 8003

Surface-mounting Thermostats Series ATH-SW

Resistance thermometer Model TR10-E, for additional thermowell

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Solenoid coil for control in potentially explosive areas Type BZ

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Thermocouple Without thermowell Model TC10-H

Pressure switch and Thermostat Type CAS

Hydraulic pressure switch 20D Acc. to ATEX

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Resistance thermometer Without thermowell Model TR10-H

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Material: Weight: Shaft Loads: Enclosure Rating: Cable: Cable Glands:

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

M-0. M-0... series control, monitoring and signalling devices. Ex e

Emergency Light Fitting for Fluorescent Lamps Series 6009

Thermostats Series 142

Transcription:

TRM150 Technical data Body Mounting position Max. ambient 70 C temperature Max. temperature 70 C at sensor Contact arrangement Diecast aluminium GD Al Si 12 according to DIN 1725. Resistant to ammoniacal vapours and seawater Any, preferably vertical Single-pole changeover switch Switching capacity 8 (5) A 250 VAC Degree of protection Mounting Calibration Plug connection Switching temperature Switching differential IP 54 according to DIN EN 175301 (with vertical installation) With wall bracket H1 or directly on the wall with 2 screws (Ø 4) Scale value corresponds to the lower switching point (with falling temperature), the upper switching point is higher by the amount of the switching differential Via angled plug to DIN EN175301 (3-pin + earth contact), cable entry Pg 11, max. cable diameter 10 mm, cable outlet possible in 4 directions spaced 90 apart. Adjustable from outside with screwdriver Not adjustable on TRM series, adjustable on TRMV series Ventilation and air-conditioning systems Room thermostats type series TRM for industrial premises FEMA room thermostats are suitable for industrial plants, greenhouses, livestock buildings and warehouses, and also for monitoring the maximum temperature in SIL 2 according IEC 61508-2 Product Summary s switchgear cabinets and relay stations. Room thermostats are supplied complete with wall bracket H1. Type Setting range Switching differential (mean values) Switching differential not adjustable TRM022-20 to +20 C 1.0 K TRM40 0 to +40 C 1.0 K TRM150 +10 to +50 C 1.0 K Switching differential adjustable TRMV40 0 to +40 C 3 10 K TRMV150 +10 to +50 C 3 10 K -TRM, page 120 Dimensioned drawing (mm) EN 175301 Protection Class: IP 54 105

Switching temperature (large screw) Switching differential (small screw) General technical information General technical information for series TX, TRM and TAM Adjustment of thermostats at lower switching point Setpoint x S corresponds to the lower switching point (with falling temperature), the upper switching point x O (with rising temperature) is higher by the amount of the switching differential x d. Setting the switching temperature (setpoint adjustment) Prior to adjustment, the setscrew above the scale must be loosened by approx. 2 turns and retightened after setting. The switching temperature is set via the spindle. The set switching temperature is shown by the scale. In view of tolerances and variations in the characteristics of sensors and springs, and due to friction in the switching kinematics, slight discrepancies between the setting value and the switching point are unavoidable. The thermostats are usually calibrated in such a way that the setpoint adjustment and the actual switching temperature correspond as closely as possible in the middle of the range. Possible deviations spread to both sides equally. Clockwise: low switching temperature Anticlockwise: high switching temperature Changing the switching differential (only for room thermostat TRMV ) The switching differential is changed by turning the setscrew within the spindle. The lower switching point is not changed by the differential adjustment; only the upper switching point is shifted by the differential. One turn of the differential screw changes the switching differential by about 1/2 of the total differential range. When adjusting please note: Switching temperature: Clockwise for lower switching point. Anticlockwise for higher switching point. Switching differential: Clockwise for larger differential. Anticlockwise for smaller differential. Electrical connection Plug connection to DIN EN175301. Cable entry Pg 11, max. cable diameter 10 mm. Cable outlet possible in 4 directions spaced 90 apart. Mounting position A vertical mounting position is preferable if at all possible. IP 54 protection is guaranteed with a vertical mounting position. A different mounting position may alter the protection class, but the operation of the thermostat is not affected. Outdoor installation of thermostats FEMA thermostats can be installed out of doors provided they are mounted vertically and suitably protected against the direct effects of weather. At ambient temperatures below 0 C, ensure that condensation cannot occur in the sensor or in the switching device. 99

100 Standard version Terminal connection 200 300 Switch housing Diecast aluminium GDAISi 12 Diecast aluminium GDAISi 12 Switching function Floating changeover contact Floating changeover contact. and connection scheme With rising teperature With rising temperature (applies only to version single pole switching from 3 1 to 3 2 single pole switching from 3 1 to 3 2 Switching capacity 8 A at 250 VAC 8 A at 250 VAC (applies only to version 5 A at 250 VAC inductive 5 A at 250 VAC inductive 8 A at 24 VDC 8 A at 24 VDC 0.3 A at 250 VDC 0.3 A at 250 VDC min. 10 ma, 12 VDC min. 10 ma, 12 VDC Mounting position Vertical or horizontal, Vertical preferably vertical Protection class IP 54 IP 65 (in vertical position) Electrical connection Plug connection to DIN EN175301 Terminal connection Cable entry Pg 11 M 16 x 1.5 Ambient temperature 15 to +70 C 15 to +70 C Switching point Adjustable with spindle Adjustable with spindle after Switching differential Adjustable or not adjustable Not adjustable (see Product Summary) Medium temperature Max. 70 C, briefly 85 C Max. 70 C, briefly 85 C Vibration strength No significant deviations up to 4 g. At higher accelerations, the switching differential is reduced slightly. Use over 25 g is not permitted. Isolation values Overvoltage category III, contamination class 3, reference surge voltage 4000 V. Conformity to DIN VDE 0110 is confirmed. Sensor systems Room sensor TRM Capillary tube sensor TAM Rod sensor TX+R10 Air duct sensor TX+R6

Room sensor TRM Capillary tube sensor TAM Terminal connection Rod sensor TX+R10 Air duct sensor TX+R6 version 500 (Ex-i) 700 (Ex-d) Switch housing Diecast aluminium GDAISi 12 Diecast aluminium GDAISi 12 Switching function Floating changeover contact Floating changeover contact. and connection scheme With rising temperature With rising temperature (applies only to version single pole switching from 3 1 to 3 2 single pole switching from 3 1 to 3 2 Switching capacity max. 100 ma, 24 VDC 3 A at 250 VAC (applies only to version min. 2 ma, 24 VDC 2 A at 250 VAC inductive 3 A at 24 VDC 0.03 A at 250 VDC min. 2 ma, 24 VDC Mounting position Vertical or horizontal, Vertically upright vertically upright Protection class IP 65 IP 65 (in vertical position) Explosion protection II 1/2G Ex ia IIC T6 Ga/Gb s 0035 II 2G Ex d e IIC T6 Gb with immersion well II 1/2D Ex ia IIlC T80 C s 0035 II 1/2D Ex ta/tb IlIC T80 C Da/Db Exception: EX-TRM : II 2G Ex d e IIC T6 Gb II 2D Ex tb IIIC T80 C Db Electrical connection Terminal connection Terminal connection Cable entry M 16 x 1.5 M 16 x 1.5 Ambient temperature 15 to +60 C 20 to +60 C Switching point Adjustable with spindle after Adjustable with spindle after Switching differential not adjustable Not adjustable Medium temperature Max. 60 C Max. 60 C Vibration strength No significant deviations up to 4 g. At higher accelerations, the switching differential is reduced slightly. Use over 25 g is not permitted. Isolation values Overvoltage category III, contamination class 3, reference surge voltage 4000 V. Conformity to DIN VDE 0110 is confirmed. Sensor systems 101

102 Plug connection Description Connection scheme 200 series Standard version Microswitch, single pole switching ZFT213 Gold-plated contacts with low contact resistance (e. g. for low voltage) Adjustable switching diff. is not available ZFT301 Terminal connection housing (IP 65) ZFT351 Protection class IP 65 and switch housing with surface protection (terminal connection housing) ZFT513 Ex-i-version 500 housing, blue cable entry and terminal connection Gold-plated contacts, protection class IP 65 ATEX-Approval: please see page 10 13 Power supply circuit: U i 24 V DC C i 1 nf I i 100 ma L i 100 µh Note to non-available items: In our article master all the possible technical combinations are not created. Therefore we recommend the previous request for clarification and selection of an alternative solution. Example for ordering: TX150-513 Code of additional function Code for temperature range Type Service functions Devices with service functions will be produced individually according to the customer s specifications. The system requires that these product combinations be identified in such a way as to prevent any possibility of confusion. These combinations are characterised by a product code with the suffix "-S" on the packaging label as well as separate labels with barcodes for each service function. Service functions ZFT5970 ZFT5971 ZFT1978 WZ2.2 AZ3.1B1 Setting of switching point according to customer s instructions Setting of switching points according to customer s instructions with lead sealing Labelling of units according to customer s instructions with sticker Test certificates according to EN 10 204 Factory certificate 2.2 based on non-specific specimen test Acceptance test certificate 3.1 based on specific test ** Switching point adjustment: Please specify switching point and direction of action (rising or falling pressure). Service functions are available for the following type series (including Ex-versions): Thermostats: TAM, TX, TRM, Ordering devices with service functions: See page 33.