WhispAire Range Hood Quiet Hood

Similar documents
WhispAire Range Hood Quiet Hood

NUTONE RANGE HOOD NTM SERIES

Hood. warning. warning. caution

! FOR DOMESTIC COOKING ONLY!

! FOR DOMESTIC COOKING ONLY!!

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

NTM SERIES INSTALLER: LEAVE THIS GUIDE WITH THE HOMEOWNER. HOMEOWNER: OPERATION AND CARE INFORMATION ON PAGES 9-10.

Operation Manual RANGE HOOD

Model U102E ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

Use, Care and Installation Guide Guide d utilisation, d entretien et d installation Guía de instalación, uso y mantenimiento.

! FOR DOMESTIC COOKING ONLY!

Pro Island Ventilation Hoods

IMPORTANT SAFETY INSTRUCTIONS

Viking Installation Guide

Viking Installation Guide

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

IMPORTANT SAFETY INSTRUCTIONS

Type of Motor & Blower

All (-4) Models 390CFM Code Compliant

***ATTENTION*** PLEASE REMOVE THE RIGHT SIDE BAFFLE FILTER TO LOCATE YOUR NEW REMOTE CONTROL.

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

GE Monogram. Installation. Instructions. Professional Vent Hoods. 48" Models ZV881WSS, ZV891YSS ZV880WSS, ZV890YSS. 36" Models ZV671WSS, ZV681YSS

User s Manual Metro/ Legend Residential Wall Mount Hood. Models: 3410 Legend 36 Hood 900 cfm 3415 Metro 36 Hood 900 cfm

Viking Installation Guide

Viking Installation Guide

Viking Installation Guide

SAFETY INSTRUCTIONS Before installation and operation, read these instructions carefully and use this product only in the manner described by the manu

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

www. TheRangeHoodStore.com

Use, Care, and Installation Guide

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT RANGE HOOD WITH M600 OR M1200 BLOWER

INSTALLATION INSTRUCTIONS

brisas Use, Care, and Installation Guide Brisas BMI-E36AG BMI-E36AS BSI-E36AS BVE-E30AS BVE-E36AS Model number: Serial Number:

HP190SL Series Slimline Radon Fans

Use, Care, and Installation Guide

Installation. Professional Indoor & Outdoor Hoods

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

KOBE Brand Range Hood

Viking Installation Guide

Use, Care, and Installation Guide

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

Use, Care, and Installation Guide

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

Self-Cleaning Range Hoods

KOBE Brand Range Hood

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

FADE Series Wall Axial Fans

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

Model 8144NC Fresh Air Ventilator

LIST OF MATERIALS. USE, CARE, AND INSTALLATION GUIDE Read all Instructions before Installing and operating this appliance WARNING

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

RANGE HOODS USER INSTRUCTIONS

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Connection Diagram (48" - 60" Widths) (Front View) Connection Diagram (54" - 66" Widths)

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

Installation Guide. Professional Indoor and Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Connection Diagrams (36" - 48" Widths) Wall Side 1 ¾. Electrical. Connection Diagram (48" - 60" Widths)

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

Operators Manual for JES-HD

Installation Instructions / Warranty

READ AND SAVE THE INSTRUCTIONS

POWER GEAR SLIDE-OUT MANUAL

INSTALLATION INSTRUCTIONS

A2P Single Phase Automatic Industrial Battery Charger

Cast Iron WARNING CAUTION. CAUTION Some parts may contain sharp edges especially as noted in manual. Wear protective gloves if necessary.

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

Installation Instructions Supertop NX

Installation Instructions Supertop NX

Installation Instructions

3-LIGHT VANITY BAR ITEM # MODEL #34674 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Charcoal Filter Installation NOTE: The charcoal filters are preinstalled if you purchased the range hood with re-circulating kit from us. 1. Remove st

Installation Instructions Supertop for Truck

Natural Gas Conversion Instructions for

Installation Instructions Trektop NX

CAB #11606 FOR John Deere X500, X520, X530, X534, X540

Installation Instructions Supertop for Truck

Level One Electric Vehicle Charging Station Wall Mount Product Guide

Chef Under-Cabinet 30 & 36

POST LANTERN ITEM # MODEL #39487 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

Transcription:

INSTALLATION INSTRUCTIONS WhispAire Range Hood Quiet Hood READ & SAVE THESE INTRUCTIONS WA6500 SERIES QT20000 SERIES IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards - including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. To reduce the risk of fire, use only metal ductwork. 8. When applicable local regulations comprise more restrictive installation and/or certification requirements, the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expenses. TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: 1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. 2. Always turn hood ON when cooking at high heat or when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). 3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. 4. Use proper pan size. Always use cookware appropriate for the size of the surface element. TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK UP A FLAMING PAN - you may be burned. 3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result. 4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher, and you already know how to operate it. B. The fire is small and contained in the area where it started. C. The fire department is being called. D. You can fight the fire with your back to an exit. IMPORTANT SAFETY INSTRUCTIONS 1. For indoor use only. 2. For general ventilating only. Do not use to exhaust hazardous or explosive materials and vapors. 3. To reduce the risk of fire or electrical shock, this range hood should not be used with an additional solid-state speed control device. 4. To reduce the risk of shock, disconnect power before servicing. 5. To reduce the risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages. PLAN THE INSTALLATION 1. Mounting height MUST BE at a minimum of 22 and at a maximum of 30 above the cooking surface from the bottom edge of the range hood. 2. The hood shall be mounted to the bottom of a standard wall cabinet. If the hood must be mounted directly to a wall, secure the hood to wall studs. 3. All wiring must comply with local codes and the unit must be properly grounded. Connection should be made to a 110-120 VAC lighting circuit (15A) in the circuit breaker or fuse box. This range hood is Convertible, it may be installed as a ducted or as a non-ducted unit. IF THE RANGE HOOD IS TO BE NON-DUCTED: Purchase non-ducted (duct-free) charcoal filter Model RFQTC. IF THE RANGE HOOD IS TO BE DUCTED: Ductwork can be installed vertically or horizontally Duct runs should be as short as possible Avoid the use of elbows Use metal foil duct tape at all joints Do not use duct smaller than the discharge on the hood For 7 round ductwork installation, use 7 round damper, Model BP87 and 7 adaptor, Model K4892000, both sold separately REGISTER YOUR PRODUCT ON LINE AT For NuTone WA6500 Series: www.nutone.ca For Broan QT20000 Series: www.broan.ca *Based on Kitchen Fire Safety Tips published by NFPA. 1 30040600E

HORIZONTAL DISCHARGE THROUGH WALL CUTOUT DIMENSIONS WALL KITCHEN CABINET SUPPLIED DUCT TRANSITION WALL CAP (MODEL 639 or 649) 7 PO RANGE HOOD 5 1 8 10¼ 1 7 16 WIRING CUTOUT 3¾ REMOVE DAMPER TRANSITION FOR THIS INSTALLATION FIGURE 1 VERTICAL DISCHARGE USING 3¼ x 10 DUCT ROOF CAP (MODEL 634 or 644) CUTOUT DIMENSIONS 7 8 TOP 18 12 9 3 8 3¼ x 10 1 7 16 7 C L 1 1 2 ELEC. K. O. 1 7 16 1 2 ELBOW (MODEL 428) 3¼ x 10 DUCT (MODEL 401) SUPPLIED DUCT TRANSITION EAVE CAP WALL CAP (MODEL 639 or 649) WALL BACK 3¼ x 10 6 RANGE HOOD FIGURE 2 CUTOUT DIMENSIONS C L VERTICAL DISCHARGE 7 8 ADJUSTABLE ELBOW (MODEL 415) ROOF CAP (MODEL 634 or 644) NOTE: For wall cap use model 647 ROOF TOP BACK 18 7 DIA 12 9 3 8 4½ 1 7 16 1 7 16 7 1 2 1 2 ELEC. K.O. 6 7 ROUND DUCT (MODEL 407) 7 ROUND DAMPER (MODEL BP87) (Not included) RANGE HOOD REMOVE BOTH 3¼ x 10 AND 4½ x 8 KNOCKOUTS FOR 7 DUCT 7 ROUND DUCT TRANSITION (MODEL K4892000) (Not included) FIGURE 3 HH0118A 2

! WARNING When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves. PREPARATION 1. Use the dimensional drawings (Refer to FIGURES 1-3) to lay out the range hood s mounting holes, wiring access and ductwork by marking the cabinet bottom and drywall where applicable. 2. Make cutouts for wiring and ductwork. 3. If the hood is to be ducted, install the ductwork so that it is flush to the range hood s mounting surface. Refer to FIGURE 1 if the range hood is to be installed with a horizontal discharge. Refer to FIGURE 2 and FIGURE 3 if the range hood is to be installed with a vertical discharge. 4. Run two-conductor wire (with ground) from a power source to the hood location. Bring approximately 12 of wiring through wiring hole in cabinet. 5. Drill four 3/32 diameter pilot holes at points where mounting holes are marked in cabinet bottom. 6. Insert four mounting screws, leaving approximately 1/4 of thread exposed. 7. Remove and retain the mounting screws securing the 3¼ x 10 duct transition to the hood. INSTALLATION LOCATORS BAFFLE PLATE FIGURE 4 7" ROUND ADAPTER (Not included) FIGURE 5 1. Remove the necessary duct opening and wiring knockout from the range hood. If the range hood is to be installed as a non-ducted unit, remove the wiring knockout only. If the range hood is to be installed as a ducted unit, a baffle plate is provided to close off the non-ducted vent. Install baffle plate (Refer to FIGURE 4) by sliding into place behind grille. Use locator bumps to orient in grille. 2. For 7 round discharge installation, refer to FIGURE 5. Secure 7 adapter (Model K4892000, sold separately) to the top of hood. Install 7 round damper (Model BP87, sold separately). For 3¼ x 10 vertical discharge installation, refer to FIGURE 6. Secure 3¼ x 10 transition (if used) to top of hood. For 3¼ x 10 horizontal discharge installation, refer to FIGURE 7. If using the supplied 3¼ x 10 duct transition, remove the damper flap from the transition to prevent possible venting interference. Position transition into wall cutout. Note: The transition does not fasten to the hood. 3. Feed the wiring through the access hold and into the electrical box. 4. Align hood s keyhole mounting slots over the four partially installed screws. 5. Making sure the duct positions over the hood s duct transition, push the hood against the rear wall. Secure hood by tightening screws. 6. Using a long blade screwdriver, reach into the discharge opening and make sure the damper flap operates freely (vertical discharge only). POSITION DUCT TRANSITION IN WALL CUTOUT SECURE TRANSITION WITH SCREWS (included) FIGURE 6 HORIZONTAL HD0342A FIGURE 7 3

WIRING CONNECTIONS All wiring connections must comply with local codes and the unit must be properly grounded. 1. Make sure box connector is secure. 2. Refer to FIGURE 8. Make wiring connections. 3. Replace electrical box cover and secure with screw. LAMP INSTALLING OR REPLACEMENT 1. Depress sides of light diffuser until tabs of diffuser disengage from slots in hood. Remove diffuser. 2. Install two 40-watt maximum, Type A-15 appliance bulbs. 3. Replace diffuser in hood by depressing sides and engaging tabs in slots in hood. HOOD WIRING HE0101A WHT BLK GREEN GROUND SCREW WHT BLK GREEN OR BARE (GROUND) SUPPLY WIRING FIGURE 8 FILTER INSTALLING AND REPLACEMENT 1. For ducted operation, install the aluminum mesh filter. For non-duct operation, install the non-ducted filter (Model RFQTC, sold separately). 2. Refer to FIGURE 9. The filter slides into channels at the back of the hood, on either side of the fan compartment, and snaps under the spring clips near the front of the fan compartment. MAINTENANCE FILTERS IMPORTANT: The aluminum filter should be removed once a month and washed in hot detergent water. Rinse in clear, warm water and shake off excess moisture before replacing. The filter may also be cleaned in your dishwasher. IN A NON-DUCTED INSTALLATION: Replace filter every 3-6 months as needed. CLEANING: The hood should be wiped off occasionally both inside and outside using warm water, mild dish detergent and a soft cloth.never use scouring powders, steel wool pads or any other abrasive cleaners which will destroy the hood s finish. HO0127 FIGURE 9 REPLACEMENT PARTS Should replacement parts be required, please indicate hood model number and appropriate part number. Contact your Broan-NuTone Canada dealer or write to Broan-NuTone Canada at the following address: Attn.: Parts Department Broan-NuTone Canada, Inc. 1140 Tristar Drive Mississauga, Ontario L5T 1H9 Telephone: 888-88Broan (27626) 4

SERVICE PARTS 13 16 9 6 12 4 5 8 1 2 3 HL0129 10 14 15 KEY NO. PART NO. DESCRIPTION 1 K7448000 Motor 2 K7577000 Motor Bracket Assembly 3 99020277 Fan Blade * R607225 External Hitch Pin (Hairpin) 4 K7457000 Lamp Socket (2 required) 5 K3720000 Fan Switch Assembly 6 R561138 Light Switch * K4402000 Rectifier Assembly (Night-Light) 8 K7504000 Light Lens 9 K4423000 Wiring Cover 10 99091033 Grille snap-in (Black) Quiet Hood 99091034 Grille snap-in (White) Quiet Hood 99091036 Grille snap-in (Almond) Quiet Hood 99091035 Grille snap-in (Biscuit) Quiet Hood 99091038 Grille snap-in (Black) WhispAire Hood 99091039 Grille snap-in (White) WhispAire Hood 99091041 Grille snap-in (Almond) WhispAire Hood 99091040 Grille snap-in (Biscuit) WhispAire Hood 12 99360246 Knobs (Black) 99360244 Knobs (White) 99360245 Knobs (Almond) 99360247 Knobs (Biscuit) 13 99091071 Baffle (Black) 99091072 Baffle (White) 99091074 Baffle (Almond) 99091073 Baffle (Biscuit) 14 RFQTA Aluminum Filter 15 RFQTC Non-Ducted Filter 16 K6413000 Filter Clip (2 required) * K1893000 3¼ x 10 Transition * K7445000 Threaded Insert (4 required) Order replacement parts by PART NO. - not by KEY NO. *Not Illustrated 5

BROAN-NUTONE CANADA ONE-YEAR LIMITED WARRANTY Broan-NuTone Canada warrants to the original consumer purchaser of its products that such products will be free from defects in materials and workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone Canada will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone Canada), faulty installation or installation contrary to recommended installation instructions. The duration of any implied warranty is limited to the one-year period as specified for the express warranty. BROAN-NUTONE CANADA S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE CANADA S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE CANADA SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary by jurisdiction. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone Canada at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Date of Installation Builder or Installer Model Number and Product Description IF YOU NEED ASSISTANCE OR SERVICE: For the location of your nearest Broan-NuTone Canada Incorporated dealer: Dial Toll-Free: 1-888-882-7626 Please be prepared to provide: Product model number Date and proof of purchase The nature of the difficulty Broan-NuTone Canada Inc. 1140 Tristar Drive, Mississauga, Ontario, CANADA L5T 1H9 www.broan.ca www.nutone.ca Product specifications subject to change without notice. Printed in Canada, Rev. 02/16/2010