USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Similar documents
Solar Power Light Meter

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Non-Contact Phase Rotation Tester

USER MANUAL. White LED Light Meter. Model LT40. Additional User Manual Translations available at

USER GUIDE Moisture Meter

Mini Multimeter with Non-Contact Voltage Detector (NCV)

USER MANUAL. Insulation Tester + DMM. Model MG320

User Guide. Model Insulation Tester / Megohmmeter

Digital Formaldehyde Meter

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Mini Multimeter with Non-Contact Voltage Detector (NCV)

User's Manual. Earth Ground Resistance Tester. Model Introduction

362 Clamp Meter. Users Manual

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Model Insulation Tester / Megohmmeter. User Manual

Safety design conforming to the following provisions

Non-Contact Phase Rotation Tester

Safety design conforming to the following provisions

True RMS Autoranging Multimeter

Phase Sequence Tester

User Guide. Model Insulation Tester / Megohmmeter

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Autoranging Multimeter

Autoranging Industrial Multimeter

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Users Manual. Phase Rotation Indicator

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

373 Clamp Meter. Users Manual

302+/303 Clamp Meter. Users Manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

365 Detachable Jaw True-rms Clamp Meter

362 Clamp Meter. Users Manual

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

323/324/325 Clamp Meter

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Visit us at

KMP Insulation-Continuity Tester. Users Manual

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Hot Wire CFM/CMM Thermo-Anemometer

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

4-WIRE EARTH RESISTANCE TESTER C1 ES P1 S. Max. AC 200V MICROPROCESSOR CONTROLLED TEST. Switch ON, TEST, SCROLL RESULTS 20Ω 200Ω 2000Ω OFF

Dawson DDM190D. Digital Multimeter User s Manual

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

80 Series V Digital Multimeter Safety Information

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

WENS30C Loop Calibrator


User's Guide. True RMS Multim eter. Extech 430

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

707Ex. Users Manual. ma Calibrator

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

OPERATING MANUAL CMP-200

i400s Calibration Information Introduction

DIGITAL RCD(ELCB) TESTER

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

DT304. Digital Temperature Logger INSTRUCTION MANUAL

Users Manual. MegOhmMeter

OPERATING INSTRUCTION

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

Volt/mA Calibrator. Manual

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

operating manual DL7 101 DIGITAL THERMOMETER

Digital Multimeter User's Manual

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Calibration Manual. Detachable Jaw True-rms Clamp Meter

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

MODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

2-Year Limited Warranty. See the Users Manual for the full warranty.

KMP7010. Ground Resistance Tester. Users Manual

Go to to register your product and find more information.

Switching DC Power Supply

3-Year Limited Warranty. See the Users Manual for the full warranty.

OPERATING INSTRUCTION

1.Safe testing IMPORTANT:

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

Model UT602/603: OPERATING MANUAL

Date received into service; / /.

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Transcription:

USER MANUAL 200A AC Mini Clamp Meter Model MA130 Please visit www.extech.com for user manual translations

Introduction Thank you for selecting the Extech Instruments 200A AC Mini Clamp Meter. The MA130 measures AC Current in three ranges 2A, 20A, and 200A. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Manual, Translations, Product Updates, Product Registration, and Customer Support. Features Measures AC Current in three manually selectable ranges 2A, 20A, and 200A 2000 count Backlit LCD display Data Hold freezes displayed reading MAX function shows highest reading Compact 17mm (0.7") jaw size Low battery indicator and Auto Power Off feature CAT II-600V and CAT III-300V safety rating Safety Information To ensure the safe operation and service of the meter, follow these instructions closely. Failure to observe warnings can result in severe injury. WARNINGS WARNINGS identify hazardous conditions and actions that could cause BODILY HARM or DEATH. Use the meter only as specified in this User Manual to avoid compromising the protections provided by the meter. Be sure to use the switch positions, and ranges when taking measurements. Do not use clamp meter on a circuit with voltages higher than 600V. Use caution working with voltages above 30 VAC RMS, 42 VAC peak, or 60 VDC. These voltages pose a shock hazard. To avoid misleading readings that could lead to electric shock and injury, replace the batteries as soon as the low battery indicator is displayed. 2

Do not use the meter in the presence of explosive gas or vapor. To reduce risk of fire or electric shock, do not use the meter if it is wet and do not expose the meter to moisture. Individual protective equipment should be used if HAZARDOUS LIVE parts in the installation where measurements are to be carried out could be accessible. CAUTIONS CAUTIONS identify conditions and actions that could cause DAMAGE to the meter or equipment under test. Do not expose the meter to extremes in temperature or high humidity. Do not expose the meter to extremes in temperature or to high humidity. Safety Symbols that are typically marked on meters and instructions This symbol, adjacent to another symbol, indicates the user must refer to the manual or user guide for further information. Risk of electrical shock Equipment protected by double or reinforced insulation Battery symbol Conforms to EU directives Do not discard this product in household trash AC measurement Earth ground 3

PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY OVERVOLTAGE CATEGORY I Equipment of OVERVOLT AGE CATEGORY I is equipment for connection to circuits in which measures are taken to limit the transient over-voltages to an appropriate low level. Note Examples include protected electronic circuits. OVERVOLTAGE CATEGORY II Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from the fixed installation. Note Examples include household, office, and laboratory appliances. OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations. Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation. OVERVOLTAGE CATEGORY IV Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation. Note Examples include electricity meters and primary overcurrent protection equipment Meter Description 1. Clamp Jaw 2. Protective barrier 3. Clamp jaw trigger open/close 4. Range selection switch 5. Hold button 6. MAX button 7. Backlight button 8. LCD display 9. Indicator for geometric center of clamp head Note: Battery compartment is located on back of meter. 4

Push-Button Descriptions H (HOLD) button Short press to freeze displayed reading (H icon is visible). Press again to release the reading. Backlight button Press and hold for at least 2 seconds to toggle the backlight ON-OFF. MAX button Press to view the highest (MAX: maximum) readings. Operating Instructions CAUTION: Read and understand all of the Safety statements listed in the safety section of this manual prior to use. Powering the Meter 1. Turn the rotary function switch to any position to power the meter. Check the batteries if the unit fails to power ON. Refer to the Maintenance section for battery and fuse replacements. 2. Turn the function switch to the OFF position to power OFF the meter. Automatic Power OFF (APO) The meter automatically powers off (APO) after approximately 15 minutes of inactivity. In APO mode, turn the rotary switch OFF and then ON to restart the meter. The meter can also be powered on by pressing any button to wake the instrument. 5

AC Current Measurements CAUTION: Observe CAT II 600V, CAT III 300V with respect to Earth Ground for the Jaw. 1. Set the Function switch to the 2A, 20A, or 200A range. 2. Press the Trigger to open the clamp jaw. 3. Clamp onto a single conductor (fully enclosing it). See diagram below for proper clamping technique. 4. Use the indicator mark to determine the geometric center of the clamp head (see Meter Description section). Position the measured electrical conductor as close to this geometric center as possible. 5. Do not allow a gap between the two halves of the jaw. 6. Read the ACA value on the LCD. Data Hold To freeze the displayed reading on the LCD, long press the Data Hold (H) button (the H icon will appear on the display). To release the Data Hold function and return the meter to normal operation, long press the Data Hold (H) button again (the H icon will switch off). MAX Reading 1. Press MAX to show the highest reading on the display. The MAXH display icon will appear and the reading shown will be the highest reading; updating only when a higher reading is encountered. 2. Press MAX again to exit this mode and to view real time readings. The MAXH display icon will switch off. 6

Display Backlight Long press the backlight button to toggle the display backlight ON or OFF. The backlight automatically dims after 15 seconds. Maintenance WARNING: To avoid electrical shock, disconnect the meter from any circuit and turn OFF the meter before opening the case. Do not operate with an open case. Battery Replacement 1. Turn power OFF. 2. Remove the (1) Phillips head screw that secures the battery compartment on the back of the meter. 3. Open the battery compartment and replace the two (2) 1.5V AAA batteries observing correct polarity. 4. Re-assemble the meter before use. Safety: Please dispose of batteries responsibly; never dispose of batteries in a fire, batteries may explode or leak. If the meter is not to be used for 60 days or more, remove the battery and store separately. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment. Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter is not to be used for 60 days or more, remove the batteries and store separately. 7

Specifications Specifications stated for ambient conditions 23 C ±5 C (73.4 F ±9 F); Relative Humidity < 75% General Specifications Display 2000 count LCD with multifunction indicators Functions Polarity Overload Protection Display rate Battery Operating Temperature Operating Humidity Storage Temperature Current (ACA) - indicates negative polarity (positive polarity assumed) Max. overload protection for clamp head terminal is 200A. O.L. is displayed. 2-3 readings/second Two 1.5V AAA batteries; Low battery display 0 C to 40 C (32 F to 104 F) 0 C to 30 C (32 F to 86 F); <75%RH 30 C to 40 C (86 F to 104 F); < 50%RH -10 C to 50 C (14 F to 122 F) Altitude <2000m (6562 ) Weight 150g (5.3 oz.) including battery Dimensions 158 x 60 x 33.5mm (6.2 x 2.4 x 1.3 ) Jaw opening 16mm (0.6 ) Standards EN 61010-1, EN61010-2-032, EN61010-2-033; Category II 600V, Category III 300V; pollution degree 2; double insulation Electromagnetic compatibility < 1V/m RF field: Overall accuracy = specified accuracy +5% of the range. Unspecified indication for 1V/m RF field. 8

Range Specifications Accuracy stated for ambient conditions 23 C ±5 C (73.4 F ±9 F) AC Current Ranges Resolution Accuracy Overload Protection 2.000 A 1mA ±(4.0%rdg+ 30 digits) 20.00 A 10mA ±(3.0%rdg + 20 digits) 200.0 A 100mA ±(2.5%rdg + 20 digits) 200A AC 200A AC 200A AC Notes: Frequency range: 50/60Hz Maximum overload protection for clamp head terminal is 200A Accuracy stated for 10~100% of range; < 20-digit residual reading for 2A open circuit. Copyright 2016 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO-9001 Certified www.extech.com 9