Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Three-Phase Ventilated

Single-Phase Ventilated

Totally Enclosed Non-Ventilated

30 KVA Transformer - 480V 3 Phase to 208Y/120V - NEMA 3R Enclosure - Copper Windings

75 kva Transformer - 480V Delta Primary - 208Y/120 Wye-N Secondary - NEMA 3R - K-13 - Copper Winding

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Dry Type Distribution Transformers

Wiring Diagram Number

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R

Dry Type Distribution Transformers

30kVA Transformer - 3 Phase Delta Primary - 380Y/220 or 400Y/230 Secondary - NEMA 3R

Transformers 6. Gross Automation (877)

HPS TITAN HPS TITAN. Three Phase. Single Phase

Non-Ventilated Automation Transformers 6

EHB Series Explosion Proof Heavy Duty Belt Drive Exhaust Fans Data sheet

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

SAFR LED SERIES S A F R L E D. Hazardous Location LED Luminaire

Features, Benefits and Functions

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

45 kva Isolation Transformer - 480V Delta Primary - 400V Delta Secondary - N3R - Copper Windings

TXB Series Explosion Proof

Comfort. Description. Applications

Dry Type Distribution Transformers

254 Series Convector. Standard Construction Features

Transformer Installation, Operation, and Maintenance Manual

Convector. Standard Construction Features

Dry Type Distribution Transformers

Efficiency is in our DNA

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

75 kva Transformer - 208V Delta Primary Voltage - 480V Delta Secondary Voltage - NEMA 3R

General Purpose Buck - Boost Wiring Diagrams... 86

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

112.5 kva Isolation Transformer - 440V Delta Primary - 110V Delta Secondary - NEMA 3R

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style (fluorescent replacement)

XPF. XPFMax Performer/al FEATURES TECHNICAL SPECIFICATIONS

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

C1D1 Solar Powered Explosion Proof LED Indicator Light - 80' Cord - C1D2 Panel

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Miscellaneous. Unit Substation 600 Volts and Below. Sealed Mini Power-Zone Transformers Industrial Control

Pauluhn ZPL explosionproof LED luminaires For drilling and marine applications

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Medium Voltage Metal-Enclosed Switches

4L EVM Hazard Gard H.I.D. Luminaires Mogul Base Factory Sealed (Groups C.D)

KH Series Kemlux III Enclosed/Gasketed

HPS Titan. Encapsulated Transformers for Harsh Environments

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

2 SLR Series Line Reactors... 50

Series A DC Link Chokes

90 kva Transformer - 208Y Wye-N Primary Voltage - 230Y Wye-N Secondary Voltage - NEMA 3R

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

N2LED Series Emergency Luminaires Non-Metallic Emergency Egress Lighting Systems with Remote or Direct Mounted Lamps.

Class I Div 2 LED Pivoting Light - 4 foot 2 lamp - 2nd Gen LED T series Style - Back Mount Swivel

30 Years of Innovative Solutions for Construction & Industry

KEMLUXIII KH SERIES HAZARDOUS LOCATION

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

Product Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1

Three Phase Transformers

Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

Class I Division 2 LED Pivoting Light - 4 foot 3 lamp - LED Oil Rig Fluorescent Replacement

112.5 kva Transformer Delta Primary - 240/120V Secondary - 60 Hz - 3 Phase - NEMA 3R

LED lighting for drilling & marine Pauluhn ZPL LED luminaires. Pauluhn ZPL. LED luminaires for drilling & marine applications

C1D1 Solar Powered Explosion Proof LED Strobe Light - 20' 16/2 SOOW Cord - C1D2 Panel

SECTION MOTOR REQUIREMENTS for HVAC

Product Information Packet VM HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1

Approx. Net Frame Product Input Voltage Output Voltage kva Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number

Dry-Type Transformers Mini-Power Centers

Midwest Dry Type Transformers

Unit Substation Transformers 5 and 15 KV Class

Three Phase Explosion Proof Switch - Non Fused - 60 Amps - Early Break Auxiliary Contacts

75 kva Isolation Transformer - 480Y Wye-N Primary - 208Y/120V Secondary - NEMA 3R Enclosure

Medium Voltage Metal-Enclosed Switches

EDS / EFS Series Control Stations

Product Information Packet CM7006A .5HP,1725RPM,3PH,60HZ,56C,X3416M,XPFC,F1

SAFJ LED SERIES S A L E D. Hazardous Location Compact LED

PRODUCT SPECIFICATIONS

STAINLESS STEEL PANEL MOUNT

Champ MLL LED luminaires

UNDERSTANDING THE DOE 2016 IMPACT: ENERGY EFFICIENT TRANSFORMERS PRODUCT GUIDE

FR Heat Exchanger Unit Heater

CX1 ProVector Explosion-Proof Heaters

Engineered solutions for power and the environment

Ventilated Distribution Transformers

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

Product Information Packet VM7006A .5HP,1725RPM,3PH,60HZ,56C,X3416M,XPFC,F1

ASCO SERIES 185 Power Transfer Switches

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

Control Circuit Transformers

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

HPS Fusion General Purpose Enclosed Transformer

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

20W LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - Class 1 Division 2

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1

Transcription:

Class I Division 2 Jefferson Electric Class I Division 2 Transformers for hazardous locations Jefferson Electric offers a full line of Class I Division 2 transformers. Jefferson Electrics Class I Division 2 transformers are for environments where normally confined volatile and flammable liquids and gases are used but may be present due to accidental rupture or breakdown of their systems. Class I Division 2 units are key in hazardous locations in maintaining a safe environment. Each unit is manufactured to ensure safety and reliability. All units are encapsulated NEMA 3R and ABS approved with the option for a 316 grade stainless steel enclosure that meets the corrosion resistance requirements. Applications Include: Petroleum refineries Chemical factories Gasoline storage and dispensing areas Utility gas plants Spray finishing areas Aircraft hangers Offshore Drilling & Production *General Specifications: Class I Division 2 Groups A,B,C & D ABS - Approved T3C - Temp Classification Enclosures - NEMA 3R Single Phase, 1-25 KVA Three Phase, 3-75 KVA Windings - Aluminum standard Indoor and Outdoor use 60 Hz standard, 50 Hz optional Electrostatic Shields optional Standard Wall-mount up to 25 KVA Temperature Rise - 115 C @ 40 C ambient standard Heat cured powder coat finish enclosures standard UL listed For more information on Jefferson Electric s Class I Division 2 Transformers, please contact your local sales rep or call us directly at (800) 892-3755 Class I Div 2-1409 Page 1

Class I Div 2 - Single Phase 1-25KVA, Temperature Rise - 115 C @ 40 C ambient standard KVA Catalog Number Fig. Height (A) Width (B) Depth (C) 120 X 240 V - 120/240 V 60Hz Taps None 1 411-2071-060 2 10.19 5.06 4.59 Wiring Diagram Est. Ship Wgt. (lbs) 19 2 411-2091-060 3 12.50 6.69 5.34 41 3 411-2101-060 3 14.56 7.56 7.15 68 5 411-2111-060 3 14.56 7.56 7.15 93 S240A 7.5 411-2131-060 4 16.12 13.50 8.55 130 10 411-2151-060 4 16.12 13.50 8.55 155 15 411-2161-060 4 21.12 16.50 10.06 255 25 411-2181-060 4 21.12 16.50 10.06 291 208 V - 120/240 V 60Hz Taps None 1 411-2072-060 2 10.19 5.06 4.59 19 2 411-2092-060 3 12.50 6.69 5.34 41 3 411-2102-060 3 14.56 7.56 7.15 68 5 411-2112-060 3 14.56 7.56 7.15 93 S208A 7.5 411-2132-060 4 16.12 13.50 8.55 130 10 411-2152-060 4 16.12 13.50 8.55 155 15 411-2162-060 4 21.12 16.50 10.06 255 25 411-2182-060 4 21.12 16.50 10.06 291 240 X 480 V - 120/240 V 60Hz Taps None 1 411-2073-060 2 10.19 5.06 4.59 19 2 411-2093-060 3 12.50 6.69 5.34 41 3 411-2103-060 3 14.56 7.56 7.15 68 5 411-2113-060 3 14.56 7.56 7.15 93 S480A 7.5 411-2133-060 4 16.12 13.50 8.55 130 10 411-2153-060 4 16.12 13.50 8.55 155 15 411-2163-060 4 21.12 16.50 10.06 255 25 411-2183-060 4 21.12 16.50 10.06 291 Class I Div 2-1409 Page 2

Class I Div 2 - Single Phase 1-25KVA, Temperature Rise - 115 C @ 40 C ambient standard KVA Catalog Number Fig. Height (A) Width (B) Depth (C) 240 X 480 V - 120/240 V 60Hz Taps: 2-2.5% FCAN + 2-2.5% FCBN Wiring Diagram Est. Ship Wgt. (lbs) 3 411-2103-062 3 14.56 7.56 7.15 68 5 411-2113-062 3 14.56 7.56 7.15 93 7.5 411-2133-062 4 16.12 13.50 8.55 130 S480B 10 411-2153-062 4 16.12 13.50 8.55 155 15 411-2163-062 4 21.12 16.50 10.06 255 25 411-2183-062 4 21.12 16.50 10.06 291 277 V - 120/240 V 60Hz Taps: 2-2.5% FCBN 1 411-2074-061 2 10.19 5.06 4.59 19 2 411-2094-061 3 12.50 6.69 5.34 41 3 411-2104-061 3 14.56 7.56 7.15 68 5 411-2114-061 3 14.56 7.56 7.15 93 S277A 7.5 411-2134-061 4 16.12 13.50 8.55 130 10 411-2154-061 4 16.12 13.50 8.55 155 15 411-2164-061 4 21.12 16.50 10.06 255 25 411-2184-061 4 21.12 16.50 10.06 291 600 V - 120/240 V 60Hz Taps: 4-2.5% FCBN 1* 411-2075-063 2 10.19 5.06 4.59 19 2 411-2095-063 3 12.50 6.69 5.34 41 3 411-2105-063 3 14.56 7.56 7.15 68 5 411-2115-063 3 14.56 7.56 7.15 93 S600B 7.5 411-2135-063 4 16.12 13.50 8.55 130 10 411-2155-063 4 16.12 13.50 8.55 155 15 411-2165-063 4 21.12 16.50 10.06 255 25 411-2185-063 4 21.12 16.50 10.06 291 * Has no Taps Class I Div 2-1409 Page 3

Class I Div 2-1409 Page 4

Class I Div 2 Wiring Diagrams Class I Div 2-1409 Page 5

Class I Div 2 Wiring Diagrams Class I Div 2-1409 Page 6

Class I Div 2 - Three Phase 3-75KVA, Temperature Rise - 115 C @ 40 C ambient standard KVA Catalog Number Fig. Height (A) Width (B) Depth (C) 208 Volts - 208/120 Volts 60Hz Taps: 2-5% FCBN 3 413-2108-010 4 13.12 15.12 8.06 Wiring Diagram Est. Ship Wgt. (lbs) 6 413-2128-010 4 13.12 15.12 8.06 140 9 413-2148-010 4 15.12 19 9.06 190 15 413-2168-010 4 15.12 19 9.06 T208H 30 413-2198-010 21 33 23 9.5 890 45 413-2218-010 21 36 24.5 11 790 75 413-2238-010 21 37 25 12.5 1050 208 Volts - 480/277 Volts 60Hz Taps: 2-5% FCBN 3 413-2101-010 4 13.12 15.12 8.06 6 413-2121-010 4 13.12 15.12 8.06 140 9 413-2141-010 4 15.12 19 9.06 190 15 413-2161-010 4 15.12 19 9.06 T208A 30 413-2191-010 21 33 23 9.5 890 45 413-2211-010 21 36 24.5 11 790 75 413-2231-010 21 37 25 12.5 1050 240 Volts - 208/120 Volts 60Hz Taps: 2-5% FCBN 3 413-2102-010 4 13.12 15.12 8.06 6 413-2122-010 4 13.12 15.12 8.06 140 9 413-2142-010 4 15.12 19 9.06 190 15 413-2162-010 4 15.12 19 9.06 T240A 30 413-2192-010 21 33 23 9.5 890 45 413-2212-010 21 36 24.5 11 790 75 413-2232-010 21 37 25 12.5 1050 240 Volts - 480/277 Volts 60Hz Taps: 2-5% FCBN 3 413-2103-010 4 13.12 15.12 8.06 6 413-2123-010 4 13.12 15.12 8.06 140 9 413-2143-010 4 15.12 19 9.06 190 15 413-2163-010 4 15.12 19 9.06 T240G 30 413-2193-010 21 33 23 9.5 890 45 413-2213-010 21 36 24.5 11 790 75 413-2233-010 21 37 25 12.5 1050 Class I Div 2-1409 Page 7

Class I Div 2 - Three Phase 3-75KVA, Temperature Rise - 115 C @ 40 C ambient standard KVA Catalog Number Fig. Height (A) Width (B) Depth (C) 480 Volts - 208/120 Volts 60Hz Taps: 2-5% FCBN 3 413-2104-010 4 13.12 15.12 8.06 Wiring Diagram Est. Ship Wgt. (lbs) 6 413-2124-010 4 13.12 15.12 8.06 140 9 413-2144-010 4 15.12 19 9.06 190 15 413-2164-010 4 15.12 19 9.06 T480A 30 413-2194-010 21 33 23 9.5 890 45 413-2214-010 21 36 24.5 11 790 75 413-2234-010 21 37 25 12.5 1050 480 Volts - 240 Volts 60Hz Taps: 2-5% FCBN 3 413-2107-010 4 13.12 15.12 8.06 6 413-2127-010 4 13.12 15.12 8.06 140 9 413-2147-010 4 15.12 19 9.06 190 15 413-2167-010 4 15.12 19 9.06 T480B 30 413-2197-010 21 33 23 9.5 890 45 413-2217-010 21 36 24.5 11 790 75 413-2237-010 21 37 25 12.5 1050 480 Volts - 480/277 Volts 60Hz Taps: 2-5% FCBN 3 413-2105-010 4 13.12 15.12 8.06 6 413-2125-010 4 13.12 15.12 8.06 140 9 413-2145-010 4 15.12 19 9.06 190 15 413-2165-010 4 15.12 19 9.06 T480C 30 413-2195-010 21 33 23 9.5 890 45 413-2215-010 21 36 24.5 11 790 75 413-2235-010 21 37 25 12.5 1050 600 Volts - 208/120 Volts 60Hz Taps: 2-5% FCBN 3 413-2109-010 4 13.12 15.12 8.06 6 413-2129-010 4 13.12 15.12 8.06 140 9 413-2149-010 4 15.12 19 9.06 190 15 413-2169-010 4 15.12 19 9.06 T600A 30 413-2199-010 21 33 23 9.5 890 45 413-2219-010 21 36 24.5 11 790 75 413-2239-010 21 37 25 12.5 1050 Class I Div 2-1409 Page 8

Class I Div 2 - Three Phase 3-75KVA, Temperature Rise - 115 C @ 40 C ambient standard KVA Catalog Number Fig. Height (A) Width (B) Depth (C) 600 Volts - 480/277 Volts 60Hz Taps: 2-5% FCBN 3 413-210B-010 4 13.12 15.12 8.06 Wiring Diagram Est. Ship Wgt. (lbs) 6 413-212B-010 4 13.12 15.12 8.06 140 9 413-214B-010 4 15.12 19 9.06 190 15 413-216B-010 4 15.12 19 9.06 T600H 30 413-219B-010 21 37 25 12.5 890 45 413-221B-010 21 37 25 12.5 790 75 413-223B-010 21 37 25 12.5 1050 Class I Div 2 Transformer Dimensional Diagrams Class I Div 2-1409 Page 9

Class I Div 2 Wiring Diagrams Class I Div 2-1409 Page 10

Class I Div 2 Wiring Diagrams Class I Div 2-1409 Page 11

Class I Div 2 Wiring Diagrams Class I Div 2-1409 Page 12