GTEC Transfer switch open transition

Similar documents
Transfer switch GTEC open or delayed transition

GTEC Transfer switch Open transition

Transfer switch OTEC open or delayed transition

Transfer switch OTEC and OTECSE open transition

OTEC Transfer switch open transition

Diesel generator set C17D5T series

Transfer switch OTPC open, closed, or delayed transition

OTPC-SE Service entrance transfer switch open transition

BTPC Bypass isolation transfer switch open or closed transition

Transfer switch OHPC open or delayed transition

CHPC Transfer switch closed transition

OTPC Transfer switch open and closed transition

OHPC/CHPC Transfer Switches

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Diesel Generator Set S3.8 Series Engine

Complete Power Systems. Accountability for Every Aspect of Onsite Power Delivery

Cummins delivers reliable power in one easy-to-use system

PowerCommand Paralleling Systems. Robust Paralleling System Solutions For Reliable Performance

Digital generator set control PowerCommand 3100

PowerCommand 500/550 Remote Monitoring System

Transfer switch OT III open or delayed transition, non-automatic

Automatic Transfer Switches. Global

PowerBox C1000 D2R and C1250 D2R. Reliable, flexible power systems engineered to provide cost-effective power even in the most remote environments

Ground fault indication relay - H550, H666, H667, H668

Paralleling Equipment

Remote Monitoring System

PowerCommand 2.2 control system

PowerCommand iwatch Wireless

QSK60 Series Gas Powered Generator Sets

PowerCommand 2.2 control system

Lean-Burn Gas Fueled Generator Sets

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Spark-ignited generator set

SECTION MOTOR CONTROL

Diesel generator set QSL9 series engine

Power Connect RX50. Series. Specification sheet. Features and benefits. Weight, size and sound level

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Gas Project Application Capabilities

Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

Diesel generator set 4BT3.3 series engine

Power Connect TM Series RX60

Rental & Construction Power kva 50 Hz Dual Frequency. Our energy working for you.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Rental Power QSL9 series engine

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label.

Digital Controls Technology

PowerCommand 1.2 control system

Horizontal Circuit Switchers

7kW. 7kW. CorePower System Residential Standby Generators Air-Cooled Gas Engine FEATURES. Power Rating Model (Composite Polymer) - 7 kw 60Hz

Quick Start Guide TS 910

Diesel generator set QSK60 series engine

PowerCommand. Digital Generator Set Control

PowerCommand 1.1 control system

Quick Start Guide TS 910 & TS 920

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

.3 Section Waste Management and Disposal.

Diesel generator set QSK60 series engine

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

Diesel generator set QSX15 series engine

Horizontal Circuit Switchers

Rental Power QSB7 series engine

Rental Power KTA50 G3 series engine

AR circuit breaker - Hydraulic magnetic,

Cutler-Hammer May 2001

PB-Series. GFCI/ELCI & Panel Seal

Diesel generator set QSL9 series engine

Powering telecoms, keeping people connected. Power generation engineered for telecoms. Our energy working for you. TM

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

Diesel generator set QSK78 series engine 2750kVA kVA 50 Hz

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Rental Power 1500 kw. Specification sheet. Description. Features. Options

PowerCommand 2100 digital generator set control

Diesel generator set QSK60 series engine

Diesel generator set QSK95 series engine

Spark-ignited generator set

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

PowerCommand. GenSet Controls

Bolted contact switches. Pringle switches

Tier4 certified diesel generator set QSK50 series engine

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Diesel generator set QSX15 series engine

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Vigilant Automatic Transfer Switches

PD-Series Ground Fault Circuit Protection

Diesel generator set QST30 series engine

Installation Manual PowerBox Containers (20 & 40 )

Cat/DCG-6D1I/07-08/03/Ver 1 Page 2/10

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

Diesel generator set QSK78 series engine

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Diesel generator set 6BT5.9 series engine

20 kw GENERAC GUARDIAN SERIES STANDBY GENERATORS - PREPACKAGED. Air-Cooled Gas Engine Generator Sets FEATURES

Application Description

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Florham Park, NJ USA Call (ASCO) for sales or service

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

Transcription:

GTEC Transfer switch open transition 40 2000 amp Description GTEC transfer switches combine reliability and flexibility in a small, economical package for transferring loads between a utility and a generator set, or between two generators. The microprocessor control monitors utility and emergency standby generator power. When utility power fails or is unsatisfactory, the control starts the generator, then transfers the load from the utility to the generator. When stable utility power returns, the switch automatically transfers the load back to the utility. For genset-to-genset applications, the generator set that is connected to the utility side of the control is the lead genset. If the lead generator set goes down or is taken offline, the transfer switch starts the second generator set and transfers the load. The control can be programmed to alternate between the two generator set at a set interval up to 300 hours. The fully integrated controller is designed for practical functionality, with LED indicators and digital push-buttons for ease of operator use. 40-2000 amp switches are third-party certified as meeting IEC 60947-6-1 AC31A. All switches bear the CE mark. 40-1250 amp switches are CCC certified by the China Quality Certification Centre. This transfer switch is designed and manufactured in facilities certified to ISO9001. Features Microprocessor control: Easy-to-use, standard control. LED displays indicate transfer switch status. Pushbuttons allow operator to activate test, exercise timing and transfer mode. Programmed transition: Open transition timing can be adjusted to completely disconnect the load from both sources for a programmed time period. Recommended for inductive loads to prevent nuisance tripping. Advanced transfer switch mechanism: True transfer switch mechanism with break-before-make action. Manual operation: Standard removable handle can be used to manually operate the switch after the power source has been completely disconnected. Multi-voltage rating: The multiple selectable voltage setting is field adjustable, and allows GTEC to be applied to voltage ranging from 110V to 277V without using external transformers. Positive interlocking: Mechanical and electrical interlocking prevent source-to-source connection through the power or control wiring. Main contacts: Silver alloy contacts with multi-leaf arc chutes are rated for 100% load interruption. They require no routine contact maintenance and provide 100% continuous current ratings. Easy to service: Single-plug harness connection and compatible terminal markings simplify servicing. Access space is ample. Door-mounted controls are field-programmable; no tool is required. Complete product line: Cummins Power Generation offers a wide range of equipment, accessories and services to suit virtually any backup power application. Warranty and service: Products are backed by a comprehensive warranty and a worldwide network of distributors with factory-trained service technicians.

GTEC Open 2 Transfer switch mechanism A powerful, economical AC solenoid operates GTEC transfer switches. Independent break-before-make action is used for 2-pole, 3-pole and 4-pole switches. On 4-pole/switched neutral switches, this action prevents the objectionable ground currents and nuisance ground fault tripping that can result from overlapping designs. A mechanical interlock prevents simultaneous closing of normal and emergency contacts. Electrical interlocks prevent simultaneous closing signals to normal and emergency contacts and interconnection of normal and emergency sources through the control wiring. High-pressure silver alloy contacts resist burning and pitting. Separate arcing surfaces further protect the main contacts. Contacts are mechanically held in both normal and emergency positions for reliable, quiet operation. Contact wear is reduced by multiple leaf arc chutes that cool and quench the arcs. Barriers separate the phases to prevent interphase flashover. Protective covers for lugs are available. Specifications Voltage rating Arc interruption Neutral bar Auxiliary contacts Up to 480VAC, 50 or 60 Hz Multiple leaf arc chutes provide dependable arc interruption. A full current-rated neutral bar is Standard on enclosed 3-pole transfer switches. Two isolated contacts (one for each source) indicating switch position are provided for customer use. Contacts are normally open, and close to indicate connection to the source. Wired to terminal block for easy access. Rated at 5 amps continuous at 100VAC or 2.5 amps continuous at 200VAC. Operating temperature -30 C (-22 F) to 60 C (140 F) Storage temperature -40 C (-40 F) to 60 C (140 F) Humidity Altitude Total transfer time (source-to-source) Manual operating handle Up to 95% at 20 C Up to 2,000 m (6,561 ft) without derating Will not exceed 100 msec with normal voltage applied to the actuator and without programmed transition enabled. Transfer switches are equipped with a removable operating handle which allows operation during servicing to facilitate troubleshooting with sources of power disconnected.

Microprocessor control Simple, easy-to-use control provides transfer switch information and operator controls LED lamps for source availability and source connected indication, exercise mode, and test mode. LED status lamps also provided for control set-up and configuration Pushbutton controls for initiating test, overriding time delays and setting exercise time Field-configurable for open or programmed transition Integral exerciser clock Control is prototype-tested to withstand voltage surges per EN 60947-6-1 Gold-flashed generator start contacts GTEC Open 3 Control functions Under-voltage sensing: All phases on the normal source, and single phase on generator source. Normal source pickup: adjustable 80-95% Dropout: adjustable 70-90% of nominal voltage Generator source pickup: 90% Dropout: 75% of nominal voltage Over-voltage sensing: All phases on the normal source. Source pickup: 120% Dropout: 125% Under-frequency sensing: Default setting is OFF. Generator source pickup: 90% of nominal frequency Dropout: 85% of nominal frequency Normal source pickup: 80% Dropout: 70% Over-frequency sensing: Default setting is OFF Normal source pickup: 130% Dropout: 140%. Genset-to-genset sensing: Same functions as above, for lead and secondary generators. Exercise mode: The control exerciser clock can be set to operate on a 7, 14, 21 or 28-day cycle with a fixed exercise period duration of 20 minutes. A convenient 12-hour offset feature offsets the exercise time by 12 hours, without having to reprogram the timer. The control can be programmed to exercise the generator with or without load. Test mode: When manually or remotely activated from the control panel, the control will start the generator and run until stopped. Can be configured to test with or without load. Transition modes Open transition/programmed: Controls the time required for the device to switch from source to source, so load-generated voltages decay to a safe level before connecting to an energized source. Recommended method of dealing with significantly inductive loads to prevent nuisance tripping. Adjustable 0-10 seconds, default 0 seconds. Open transition/in-phase: Initiates open transition transfer when in-phase monitor senses both sources are in phase. Operates in a break-before-make sequence. Includes ability to enable programmed transition as a backup. If sources are not in phase within 120 seconds, the system will transfer using programmed transition. Time-delay functions Engine start: Prevents nuisance genset starts due to momentary power variation or loss. Adjustable 0-10 seconds, default 3 seconds. Transfer normal to emergency: Allows genset to stabilize before application of load. Prevents power interruption if normal source variation or loss is momentary. Allows staggered transfer of loads in multiple transfer switch systems. For genset-to-genset applications, delays transfer of load from lead to secondary generator. Adjustable 0-300 seconds, default 5 seconds. Re-transfer emergency to normal: Allows the utility to stabilize before re-transfer of load. Prevents needless power interruption if return of normal source is momentary. Allows staggered transfer of loads in multiple transfer switch systems. For genset-to-genset applications, delays re-transfer of load from secondary back to lead generator. Adjustable 0-30 minutes, default 10 minutes. Engine stop: Maintains availability of the genset for immediate reconnection if the normal source fails shortly after transfer. Allows gradual genset cool down by running unloaded. Adjustable 0-30 minutes, default 10 minutes. Elevator signal relay: Requires optional elevator signal relay (M032). Delays transfer for specified interval to prevent a power interruption during elevator operation. Options Elevator signal relay (M032): Provides relay output contacts for sending a load-disconnect warning signal to the elevator control. Transfer/re-transfer delay time is selectable for 0, 1, 2, 3, 5, 30, 120 or 300 seconds. Programmable exerciser clock (J030): Provides a fully-programmable 7-day clock to provide greater flexibility in scheduling exercise periods than standard integral exerciser. Peaking function feature allows for generator operation during periods of high utility rates. Manual restore (S006): Provides a key switch on the front door to allow the operator to control when the switch transfers to the available normal source.

GTEC Open 4 Electrical performance The transfer switches listed below must be protected by either circuit breakers or fuses. The following WCR ratings are available when protecting the transfer switch with a circuit breaker or fuse. Short circuit ratings are stated in symmetrical RMS ampere. Fuse protection Transfer switch ampere Overload current (make-break test) Endurance cycles at current (operational performance capability) WCR at 480V max with current limiting fuse 40, 63 95 amps 6000 at 63 amps 26,000 amps 100, 125 188 amps 6000 at 125 amps 26,000 amps 160, 200, 225, 250 375 amps 6000 at 125 amps 38,000 amps 350, 400, 500 750 amps 630, 800 1200 amps 1000, 1250 1875 amps 1600, 2000 3000 amps 1000 at 0 amps 2000 at 500 amps 1000 at 0 amps 2000 at 800 amps 1500 at 0 amps 1500 at 1250 amps 1500 at 0 amps 500 at 2000 amps 50,000 amps 55,000 amps 65,000 amps 120,000 amps Max fuse, size and type RT16NT-00 63 amp RT16NT-00 125 amp RT16NT-2 250 amp RT16NT-3 500 amp RT16NT-4 800 amp RT16NT-4 1250 amp KRP-C 3000 amp Class L Fuse type Transfer switch ampere 40, 63 63A 100, 125 125A 160, 200, 225, 250 250A 350, 400, 500 500A 630, 800 800A 1000, 1250 1250A 1600, 2000 2000A Max breaker rating Specified Circuit breaker protection manufacturer, model and type Schneider: NSX160FTM, EZD100, NSD100F, NSD100K Siemens: 3VU, 3RV1, 3VT1 ABB: Isomax S1, S2X80, Sim100 Schneider: NSX160FTM, NSD160K Siemens: 3VL, 3VT1 ABB: Isomax S2, Isomax S3, S3X, Sim250 Schneider: NSX250NTM, NSD250K Siemens: 3VL, 3VT2 ABB: Isomax S3, S4X, Sim250 Schneider: NSX630NTM, NSD630K Siemens: 3VL,3VT3 ABB: Isomax S4, S6X, Sim500 Schneider: MT08, MT10, NW08 Siemens: 3VL, 3WT, 3VT4 ABB: Isomax S6, E1B, E1N, E1S Schneider: MT12, NW16 Siemens: 3VL, 3WT, 3VT5 ABB: Isomax S7, E2B, E2L Schneider: MT20, MT25, NW20, NW25 Siemens: 3WT ABB: E1N, E2N, E2S, E3S

Enclosures GTEC Open 5 The transfer switch and control are mounted in a key-operated locked enclosure. Enclosures meet IEC 60947-6-1 standard. 40-500 amp switches are front-connected. 630-2000 amps are rear-connected. Standard enclosure is grey. Green is available as an option (P152). Cable tie bars are available to relieve stress on lugs for switches smaller than 500 amps. Dimensions: IP32 Amp rating Height Width Door closed Door open Weight Outline drawing in mm in mm in mm in mm lb kg 40, 63 31.4 800 23.6 600 8.8 226 31.4 800 101.4 46 0300-6004 100, 125 31.4 800 23.6 600 8.8 226 31.4 800 105.8 48 0300-6004 160, 200, 225, 250 39.3 1000 31.4 800 8.8 226 39.3 1000 125.6 57 0300-6005 350, 400, 500 39.3 1000 31.4 800 8.8 226 39.3 1000 143.3 65 0300-6005 630, 800 53.9 1370 29.2 742 24.8 631 53.0 1348 385.8 175 0300-6006 1000, 1250 53.9 1370 29.2 742 24.8 631 53.0 1348 405.6 184 0300-6006 1600, 2000 78.7 2000 39.4 1000 44.3 1126 83.7 2126 888.9 400 A0281839 Dimensions: IP54 Amp rating Height Width Door closed Door open Weight Outline drawing in mm in mm in mm in mm lb kg 40, 63 34.0 864 23.5 598 11.6 296 31.0 788 110 50 0300-4559 100, 125 34.0 864 23.5 598 11.6 296 31.0 788 110 52 0300-4559 160, 200, 225, 250 41.9 1064 31.6 804 11.6 296 39.0 991.8 143.3 65 0300-4560 350, 400, 500 41.9 1064 31.6 804 11.6 296 39.0 991.8 160.9 73 0300-4560 630, 800 53.9 1370 29.5 750 26.6 676 51.9 1319 188 0300-4561 1000, 1250 53.9 1370 29.5 750 26.6 676 51.9 1319 414.5 188 0300-4561 1600, 2000 78.9 2004 39.2 996 45.3 1150 83.7 2126 892.9 405 A026M050

GTEC Open 6 Submittal detail: options Current ratings 40 63 100 125 160 200 225 250 350 400 500 630 800 1000 1250 1600 2000 Voltage ratings R060* 110 to 139 R061* 220 to 240 R062* 255 to 277 R063 110 to 277 Pole configuration A027 Poles - 2 (solid neutral) A028 Poles - 3 (solid neutral) A029 Poles - 4 (switched neutral) Frequency A044 60 Hertz A045 50 Hertz A086-7 50/60 Hertz Application A035 Utility-to-genset A037 Genset-to-genset * Only available with L-L controller option. System Options A041 Single phase, 2-wire or 3-wire A042 Three phase, 3-wire or 4-wire Enclosure B004 Open construction: no enclosure - includes automatic transfer switch and controls (1600 2000 amp open construction not available) B901 IP32 general purpose indoor B014 IP54 general purpose outdoor P152 Optional paint colour: Onan green M048 Protective shield Control voltage M033 12V, Genset starting voltage M034 24V, Genset starting voltage Control options J030 Add-on programmable exercisor clock M032 Relay signal module S006 Manual restore switch Battery chargers K001 2 amps, 12/24 volts Auxiliary relays Relays are factory installed. All relays provide two sets of form C (DPDT) contacts rated 5 amps at 250VAC. Relay terminals accept one 0.75 mm to two 4 mm wires per terminal. L101 24 VDC coil: installed, not wired (for customer use). L102 24 VDC coil: emergency position - relay energized when GTEC in Source 2 (emergency) position. L103 24 VDC coil: normal position - relay energized when GTEC in Source 1 (normal) position L201 12 VDC coil: installed, not wired (for customer use) L202 12 VDC coil: emergency position - relay energized when GTEC in Source 2 (emergency) position L203 12 VDC coil: normal position - relay energized when GTEC in Source 1 (normal) position Warranty Warranty: 12 months from commissioning to a maximum 18 months after date of sale. Accessories AC-176 Specification sheet

GTEC Open 7 www.cumminspower.com North America 1400 73rd Avenue N.E. Minneapolis, MN 55432 USA Phone 763 574 5000 Fax 763 574 5298 Asia Pacific 10 Toh Guan Road #07-01 TT International Tradepark Singapore 608838 Phone 65 6417 2388 Fax 65 6417 2399 Brazil Rua Jati, 310 Guarulhos Sao Paulo CEP 07180-140 Phone 55 11 2186 4195 Fax 55 11 2186 4729 Europe, CIS, Middle East & Africa Manston Park Columbus Ave. Manston Ramsgate Kent CT 12 5BF United Kingdom Phone 44 1843 255000 Fax 44 1843 255902 Specifications are subject to change without notice. 2013 Cummins Power Generation. All rights reserved. Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand, InPower and Our energy working for you. are trademarks of Cummins Power Generation.