Installation Instructions CAUTION

TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Installation Instructions (07-08) CAUTION

TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

ASSA ABLOY Universal Door Closers

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

TS93 EMF T/PT/TDE. Surface applied door closer

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8" I.D. Air Inlet Tubing Connected To Control Box

5600 Series Power Operator Installation and Instruction Manual

Closer with traditional styling for low to moderate traffic openings 78-B/F DOOR CLOSER CATALOG

ROFU TJ 152-A. Y ALE SECURITY GROUP 50BC Series Door Closer. 50BC Series Door Closers. Sizing Chart for Installations. Ordering Information

9000 Series Trinity The world's most intelligent door closer

Multi-feature closers with compact design, ideal for application on interior doors DOOR CLOSER CATALOG

Multi-point closer/holder with motion sensor 7100SZ DOOR CLOSER CATALOG

Power drill Center punch Wire stripper

7100SZ SERIES. Multi-Point Closer/Holder with Motion Sensor

78-B/F Series. Traditional Door Closers

7100SZ Series SafeZone Installation and Instruction Manual

Multi-sized cast iron closer for high use applications DOOR CLOSER CATALOG

51 Series Door Closers. An ASSA ABLOY Group brand

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

9540 SERIES. Cast Iron Door Closer

5300 Series 5300 SERIES

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG

Contents. Section 5: Adjustments Ball Detect Adjustment Transport Band Tension Adjustment


SAFETY REASONABLE EFFORT. ANY BINDING, SAGGING, LOOSE HINGES, OR DAMAGED HINGES MUST BE REPAIRED BEFORE CONTINUING WITH THIS INSTALLATION!

Norton ABS-AMERICAN BUILDING SUPPLY, INC Series Multi-Sized Closers - Packed 6 per case

51 Series Door Closers. An ASSA ABLOY Group brand

These door closers should NOT be installed on the exposed side (weather side) of exterior doors.

7500/7700 SERIES INSTITUTIONAL DOOR CLOSER

7570 SERIES Security Door Closer

PFT-71 Transom Connector w/fin Installation Instructions

TECHNICAL INFORMATION

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

422 Series. Cam Action Door Closer

7100SZ Series SafeZone. Multi-Point Closer/Holder with Motion Sensor

Electromagnetic Door Holder/Releases

1600 SERIES ALUMINUM STOREFRONT DOOR CLOSERS

HOW TO TELL HAND OF DOOR:

Door Closer. DC4600 Series

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

Door Controls DOOR CLOSERS

57-1. Front door. Tools. Special tools and equipment. T Socket 3320/2 Bit insert for Socket T Assembly tool

4040XP Series Door controls

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

*24191* 4040SEL Sentronic. 35 ft-lbs 48 N-m 62 N. Installation CAUTION. Customer Service. Installation Instructions

1130 Series Door controls

PFT-61 LH & RH Sidelite Transom Patch Fitting w/stop & Fin Installation Instructions

Installation Guide. Stowe Cargo Management System. Table of Contents

Shipped set to size 3. Standard closer offers 3 installation options. - Regular (Pull side) - Top Jamb (Push side) - Parallel Arm (Push side)

DC5000 Series. Cam Action Door Closer

U1500. Surface Applied Door Closers

LIGHT DUTY ROLL UP DOOR

1120 Series Door controls

Premium Dry Freight (Plywood) Door Installation REFERENCE FIGURE 1

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

D O O R C L O S E R S

D-1610/D-1611 SERIES: DOOR CLOSERS. D-1610/D-1611 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY.

MOUNTING FINISH COVER CYLINDER **ARM FUNCTION REGULAR (DOUBLE) DESIGNER METAL NON-HANDED NON-SIZED

Copyright , 2018 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express

D o o r C l o s e r s

THE GLIDER 5th Wheel Attachment

ASSA ABLOY. 7100SZ Series SafeZone External Sensor. Installation and Instruction Manual ASSA ABLOY. Patent Pending

Stowe Cargo Management System

*24828* 1 Installation. Left Hand Shown, Right Hand Opposite. Customer Service

1130 Series. Door Closers. SARGENT Manufacturing Company 2004, 2007 All rights reserved

OPERATOR S MANUAL R-Series Roust-a-Bout

SCION tc STRUT TIE BAR Preparation

4040XPT Series Door controls

1461 Series Door controls

An ASSA ABLOY Group brand. 400/4400 Series. Institutional Door Closer

D-3550 / D-3551 SERIES: DOOR CLOSERS. D-3550 / D-3551 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY.

HIGH SECURITY CLOSERS SERIES

RTS88. Overhead Concealed Door Closer

626F Exit Device Trim Installation Instructions

* * Maintenance Kit

4031 Series Door controls

HIGH SECURITY SERIES

Section 13. Tail Rotor Drive. RotorWay International A600 TALON Construction Manual. Section 13. Page A

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

High Security Closers Series

235/245400, , 28N

Installation Instructions Lockey TB 250/450/650 Plus Hydraulic Pedestrian Gate Closer (with hydraulically adjustable closing speed)

KEANE MONROE a member of the record group

Installation Instructions

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W Trailer Hitches 1216 Hawaii Road / PO Box 186 Humboldt, KS P: F:

Hunter Automatics HA-8. Installation Manual

<THESE INSTRUCTIONS MUST BE GIVEN TO THE END USER> B&W

Transcription:

Installation Instructions Series 78-B/FHA Hold Open Traditional Style Door Closers Read these instructions before proceeding with the installation. Make sure that the door opens the full angle desired and latches without any binding action or interference. Select the type of installation from figure 1 below. Note: For special applications, a separate door and frame preparation template is packed with these instructions. use this instruction sheet for installation sequence and closer adjustments only. Check hand of door, see figure 1 below. Hand of door closer must be the same as hand of door. Door closer is handed but can be easily reversed. SEE PAGE 4 FOR INSTRUCTIONS FOR REVERSING HAND OF CLOSER. Type of Installation and Handing of Door Regular Installation Parallel Installation Figure 1. For installation on PULL SIDE of Door ONLY For installation on PUSH SIDE of Door ONLY See Page 2 for Template and Installation See Page 5 for Template and Installation Opposite from Opposite from Latch Latch Latch Latch 1

Regular Mounting Dimensions Template Figure 2. Do not scale drawing Dimensions are in inches (mm). Shown Same dimensions apply for measured from centerline of pivot point. Indexing of Main Figure 4. Pinion Shaft Index Pinion Shaft Index 2

Installation Sequence 1. Using the template at the top of page 2, see figure 2, select the angle of opening desired. Locate and mark for 4 holes on the door for the closer body and 2 holes on the frame for the arm shoe. 2. Prepare the door and frame for fasteners using the information from the "Preparation for Fasteners" chart, figure 3 on page 2. 6. Following the main arm indexing illustrations in figure 4, place main arm onto the closer pinion shaft. Install and tighten main arm screw with a 1/2" wrench. 3. Install closer body to door as shown. 7. Open door slightly and assemble connecting rod into holder loop. Close and latch door. Adjust secondary arm assembly so that the main arm is perpendicular to face of door. Tighten set screw securely. 4. Disassemble holder loop assembly from the main arm assembly by loosening set screw. 5. Fasten holder loop assembly to frame face as shown. NOTE: Holder Adjustment Nut must be UP for DOWN for Holder Adjustment Nut 8. Hold Open Adjustment - Open door to angle of hold open desired and tighten holder adjustment nut with wrench supplied. 9. Closing Tension - Place wrench (packed with door closer) on ratchet as shown. Swing wrench away from hinge to wind spring between 3 to 10 notches, engage arm dog in ratchet, increase or decrease spring power to suit conditions. Caution - Underwound spring (less than 3 notches) or overwound spring (more than 10 notches) will cause spring breakage. 3

Regular Closer Adjustment - Closing Speed... Controlled by the regulating valve on the end of the closer closest to the hinge. Sweep Speed... Controls the door's speed in the sweep speed range, see illustration. Full 360 clockwise turns decrease the sweep speed. Full 360 counter-clockwise turns increase the sweep speed. Latch Speed... Controls the door's speed in the latch speed range, see illustration. A partial turn, up to a maximum of 1/2 turn (180 ) in either direction determines the latch speed.... Controlled by the regulating valve on the end of the closer farthest from the hinge. cushions or slows the door opening speed near the end of the opening cycle. Full 360 clockwise turns increases resistance to opening. Full 360 counter-clockwise turns decreases resistance to opening. Note: If backcheck is encountered extremely early in the opening cycle, rotate the valve 1/2 turn (180 ) to eliminate early opening resistance. Caution... To avoid damage to closer, never fully close the backcheck regulating valve. Hydraulic Control Figure 5. Range Sweep Speed Range Latch Speed Range Note: All valves adjustable with 1/8" hex-key furnished in screw pack. Closing Speed Control Figure 6. Full turns for Sweep Range Control Figure 7. Full turns for Range 1/2 turn max. for Latch Range Parallel Closer Adjustment - Closing Speed... Controlled by the regulating valve on the end of the closer farthest from the hinge. Sweep Speed... Controls the door's speed in the sweep speed range, see illustration. Full 360 clockwise turns decrease the sweep speed. Full 360 counter-clockwise turns increase the sweep speed. Latch Speed... Controls the door's speed in the latch speed range, see illustration. A partial turn, up to a maximum of 1/2 turn (180 ) in either direction determines the latch speed.... Controlled by the regulating valve on the end of the closer closest to the hinge. cushions or slows the door opening speed near the end of the opening cycle. Full 360 clockwise turns increases resistance to opening. Full 360 counter-clockwise turns decreases resistance to opening. Note: If backcheck is encountered extremely early in the opening cycle, rotate the valve 1/2 turn (180 ) to eliminate early opening resistance. Caution... To avoid damage to closer, never fully close the backcheck regulating valve. To Reverse Closer Hand 1. Remove main arm screw, arm assembly, ratchet, and top cover. Reversing Closer Hand Figure 8. 2. Lift out spring using screwdriver wedged between coils. (See figure 8) 3. Reverse spring and re-assemble to required hand. (See figure 8) 4. Rotate shaft to required hand. (See figure 8) 5. Replace cover and insert ratchet, lining up slot with inner hook on spring. L R 4

Parallel Mounting Dimensions Template Frame Preparation Figure 9. Do not scale drawing Door Preparation No. 88 Drop Plate Mounting Holes Only Shown Same dimensions apply for measured from centerline of pivot point. Dimensions are in inches (mm). Indexing of Main Figure 11. Pinion Shaft Index Pinion Shaft Index 5

Installation Sequence 1. Using the template at the top of page 5, see figure 9, select the angle of opening desired. Locate and mark for 4 holes on the door for either the closer body or #88 drop plate and 4 holes on the frame for the soffit plate. 2. Prepare the door and frame for fasteners using the information from the "Preparation for Fasteners" chart, figure 10 on page 5. 3. Install closer body to door as shown. If a backplate is used, mount it first, then fasten the closer to the backplate. 6. Following the main arm indexing illustrations in figure 11, place main arm onto the ASSA closer ABLOY pinion shaft. Install and tighten main arm screw with a 1/2" wrench. 7. Open door slightly and assemble connecting rod into holder loop. Close and latch door. Adjust secondary arm assembly so that the main arm is approximately 2 from parallel with face of door. Tighten set screw securely. 4. Disassemble holder loop assembly from the main arm assembly by loosening set screw. 5. Fasten soffit plate to frame soffit with 4 mounting screws. 8. Hold Open Adjustment - Open door to angle of hold open desired and tighten holder adjustment nut with wrench supplied. Holder Adjustment Nut DOWN 9. Closing Tension - Place wrench (packed with door closer) on ratchet as shown. Swing wrench toward hinge to wind spring between 3 to 10 notches, engage arm dog in ratchet, increase or decrease spring power to suit conditions. Caution - Underwound spring (less than 3 notches) or overwound spring (more than 10 notches) will cause spring breakage. 6 3000 Highway 74 East Monroe, NC 28112 Tel: (877)- 974-2255 Fax: (800)-338-0965 www.nortondoorcontrols.com