No part of this publication may be reproduced.without written permission.

Similar documents
No part of this publication may be reproduced without written permission.

142F 144F GASOLINE ENGINE SM-142F-01A INSTRUCTION MANUAL

GX120 GX160 GX200 OWNER S MANUAL 32ZH X32-ZH Serial number and engine type HONDA EUROPE N.V.(EEC)

Owner s Manual ELECTRIC GENERADORS R7100DP / G7100G

AG-HA-2500N GASOLINE GENERATOR

No part of this publication may be reproduced without written permission.

No part of this publication may be reproduced without written permission.

Böhler-AG GASOLINE GENERATOR

GASOLINE GENERATOR SET SPG8000 PORTABLE GENERATOR INSTRUCTION MANUAL IMPORTANT!

rmm Indicates a strong possibility of severe personal injury or loss of

FOR SAFE OPERATION. * Exhaust contains poisonous carbon monoxide Avoid inhalation of exhaust gases. Never engine in a closed garage or confined area.

Commercial Series Generator Operator Manual (with Kohler Command series engines)

YK1900i DIGITAL INVERTER GASOLINE GENERATOR OWNER S MANUAL PLEASE READ THIS MANUAL CAREFULLY. IT CONTAINS IMPORTANT SAFETY INFORMATION.

Owner s Manual PORTABLE GENERATOR. Model: PR2800 PR6500

SMQGZ F-02 PORTABLE WATER PUMP QGZ F INSTRUCTION MANUAL

2000 WATT DIGITAL GENERATOR

Honda WX10T OWNER S MANUAL

WUXI KIPOR POWER CO., LTD. DIGITAL INVERTER GENERATOR

Owner s Manual. 100 Amp. DC WELDER 600W GENERATOR GASOLINE 6.5HP

Gasoline Inverter Generator

No part of this publication may be reproduced without written permission.

EMm Indicates a strong possibility of severe personal injury or loss of

WUXI KIPOR POWER CO., LTD. DIGITAL INVERTER GENERATOR

Owner's Manual GASOLINE GENERATOR


Inverter Generator Start Manual

SECTION 6 2 SERVICE PROCEDURES AND SPECIFICATIONS. Engine. Specifications

Engines Original Instructions Model: DG350

Inverter Generator Start Manual

Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without incurring any obligation.

Part No FJ180V KAI. 4-stroke air-cooled gasoline engine OWNER, S MANUAL

INTRODUCTION SAFETY MESSAGES CONTENTS OWNER S MANUAL WDP30X WARNING WARNING CAUTION

PF-4000, PF-4010, PF-4210 MULTI-PURPOSE ENGINE

SECTION 6 2 SERVICE PROCEDURES AND SPECIFICATIONS. Engine. Specifications

1200W INVERTER GENERATOR

Owner s Manual. GENERATOR EB2000i. o2013 Honda Motor Co., Ltd. -All Rights Reserved. See page 78 for Initial Use Instructions

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine

OWNER S MANUAL DT177F DT188F DT190F - 1 -

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

Owner s Manual. GENERATOR EU2000i. o Honda Motor Co., Ltd. -All Rights Reserved. See page 82 for Initial Use Instructions

GX120 GX160 FOR RAMMER-TYPE COMPACTORS

GXH50 OWNER S MANUAL MANUEL DE L UTILISATEUR MANUAL DEL PROPIETARIO INTRODUCTION...1 ENGLISH FRANÇAIS ESPAÑOL SAFETY MESSAGES...

Owner s Manual PUMP WB20XT/WB30XT. 201 Honda Motor Co., Ltd. All Rights Reserved

Water pump Owner's Manual

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

This manual covers the operation and maintenance of water pump: 25ZB21-1.2Q

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

Owner s Manual. GENERATOR EU3000is. o Honda Motor Co., Ltd. -All Rights Reserved. See page 85 for Initial Use Instructions

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INTRODUCTION SAFETY MESSAGES CONTENTS OWNER S MANUAL WDP30X WARNING: WARNING CAUTION

PLEASE READ THIS MANUAL

GXH50 OWNER S MANUAL MANUEL DE L UTILISATEUR MANUAL DEL PROPIETARIO INTRODUCTION ENGLISH FRANÇAIS ESPAÑOL SAFETY MESSAGES CONTENTS

Owner, s Manual WATER PUMP WT20X WT30X WT40X. C 2012 Honda Motor Co., Ltd. -All Rights Reserved

G2200 G4000 G5500 G6000E

GENERATOR EB4000X EB5000X EB6500X

These labels warn you of potential hazards that can cause serious injury. Read them carefully.

1100W PORTABLE GENERATOR

Gasoline Engine. Owner s Manual 120F 160F 200F 240F 270F 340F 390F

Owner, s Manual. GENERATOR EB3000c. C Honda Motor Co., Ltd. -All Rights Reserved

PREFACE. Thank you for purchasing a Kipor Generator from the Coast Distribution System.

Owner s Manual. GENERATOR EU6500is. o2007 Honda Motor Co., Ltd. -All Rights Reserved. See page 78 for instructions on assembling your generator

mimei Indicates a strong possibility of severe personal injury or death if instructions are not followed.

Owner s Manual. GENERATOR EU3000i. o2009 Honda Motor Co., Ltd. -All Rights Reserved. See page 83 for Initial Use Instructions

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

500Wi Digital Inverter Generator By POWERHOUSE

GASOLINE GENERATOR SET USER S MANUAL

Owner s Manual WATER PUMP WX10. o Honda Motor Co., Ltd. -All Rights Reserved

Petrol Engine Powered Pump Instruction Manual

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

Owner s Manual WATER PUMP WH15X/WH20X. o2011 Honda Motor Co., Ltd. -All Rights Reserved

igx240 igx270 igx340 igx390

Owner s Manual. GENERATOR EU1000i. o2013 Honda Motor Co., Ltd. -All Rights Reserved. See page 84 for Initial Use Instructions

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

PH2100PRi Digital Inverter Generator Operating Instructions

720W PORTABLE GENERATOR

Operator s Manual Water Pumps WP201, WP30, WP40

LAWNMOWER OWNER S MANUAL & Service Record Booklet HUT216

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E

PORTABLE INVERTER GENERATOR MODEL

(J Indicates the possibility of equipment damage if instructions are not followed.

QUESTIONS? Contact your Honda dealer. There is a dealer locator at powerequipment.honda.com

Owner s Manual. GENERATOR EU3000is. o Honda Motor Co., Ltd. -All Rights Reserved

Owner, s Manual WATER PUMP WX10T. Includes US and Canadian Models. C 2014 Honda Motor Co., Ltd. -All Rights Reserved

8500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL

The HRA-21 meets CPSC blade safety requirement for walkbehind rotary power mowers.

Gasoline Engine Owner s Manual

GX610 GX620 GX670 OWNER S MANUAL MANUEL DE L UTILISATEUR MANUAL DEL PROPIETARIO INTRODUCTION...1 ENGLISH FRANÇAIS ESPAÑOL SAFETY MESSAGES...

Powerland Tri Fuel Generator. Owner s Manual. Full Power Output Panel SERIES GASOLINE, LPG, NG POWER

Gasoline Engine FOR YOUR SAFETY. Operator s Manual. Tame the Great Outdoors TM MODEL NUMBER 156F SERIAL NUMBER PURCHASE DATE

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

Gasoline Engine Owner s Manual G200F(D)A/G210F(D)A G300F(D)A G390F(D)A/G420F(D)A

Petrol Engine Powered Pump Instruction Manual

PETROL INVERTER GENERATOR. Models HY1000Si - HY2000Si

GX630 GX660 GX690 OWNER S MANUAL MANUEL DE L UTILISATEUR MANUAL DEL PROPIETARIO INTRODUCTION...1 ENGLISH FRANÇAIS ESPAÑOL SAFETY MESSAGES...

KIPOR POWER CO., LTD. DIGITAL GENERATOR

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

BRUSH CUTTER UMK435T OWNER S MANUAL. Honda Motor Co., Ltd MVK X3M-VK *UMK435T(3MVK9600)-omote 4/9/08 13:37 Page 1

Transcription:

Thank you for purchasing a Honda generator. This manual covers operation and maintenance of the EG3500X generators. All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without incurring any obligation. No part of this publication may be reproduced.without written permission. This manual should be considered a permanent part of the generator and remain with the generator when sold. Pay special attention to statements preceded by the following words: - Indicates a strong possibility of severe personal injury or loss of life if instructions are not followed. CAUTION: Indicates a possibility of personal injury or equlpment damage if inetructions am not followed. NOTE: Gives helpful information. If a problem should arise, or if you have any questions about the generator, authorized Honda dealer. consult an m The Honda generator is designed to give safe and dependable service lf operated according to instructions. Read and understand the Owner s Manual beforc operating the generator. Failure to do so could result in personal injury or equipmen damage. 1

CONTENTS CONTENTS 1. CAUTION LABEL LOCATION..... 3 2. GENERATOR SAFETY..... 5 3. COMPONENT IIJENTIFICATION..... 6 4. PRE-OPERATION CHECK..... 6 5. STARTING THE ENGINE... 11 6. GENERATOR USE... 14 7. STOPPING THE ENGINE..... 17 9 High altitude operation... 18 8. MAINTENANCE... 19 9. TRANSPORTING/STORAGE..... 27 10. TROUBLESHOOTING..... 29 11. SPECIFICATIONS..... 31 12. WIRING DIAGRAM... 32 13. WARRANTY SERVICE... 33 2

1. CAUTION LABEL LOCATION HONDA MOTOR CO., LTD. MADE IN JAPAN Q 3

mcnfck for SPItlEO flttl OR futl LtAKS. SIOP fnglyt BIfORf RfflMN6 lconlrorol OUll IYI A NI fulli All f.ssfncf ARRflfR Lf MOIfUR AVAYl Of ROARf Lf PLIIW. ~INSPWIUNAR PARA COMBUSllBLf OOlRAYADO

2. GENERATOR SAFETY To ensure safe operation - l Place the generator at least lm (3 ft) away from buildings or other equipment when operating the generator. l Operate the generator on a level surface. If the generator is tilted, fuel spillage may result. l Exhaust gas contains poisonous carbon monoxide. Never run the generator in an enclosed area. Be sure to provide adequate ventilation; l Know how to stop the generator quickly and understand operation of all the controls. Never permit anyone to operate the generator without proper instrutions. l Keep children and pats away from the generator when it is in operation. l Keep away from rotating parts while the generator is running. 0 The generator is a potential source of electrical shbcks when misuad; do not operat with wet hands. Do not operate the generator in rain or snow and do not let it get wet. 5

3. COMPONENT IDENTIFICATION CHOKE LEVER OIL ALERT LAMP I ENGINE SWITCH / I VOLTAGE SELECTOR SWITCH AC CIRCUIT BREAKER / AC RECEPTACLER FUEL VALVE CARBUR DRAlN S SEDkENt - CUP I RECOIL STARTER GRIP ENGINE OIL-FILLER CAP \ ENG INE OIL DRAIN PLUG 6

GASOLINE FILLER CAP GROUND TERMINAL AIR CLEANER RK PLUG 7

4. BRE-OPERATION CHECK ENGINE OIL CAUTION : l Engine oil is a major factor affecting engine performance and service lie. Non-detergent oils and vegetable oils are not recommended. l Be sure to check the engine on a level surface with the angina stopped. Use Honda 4-stroke oil, or an equivalent high detergent premium quality motor oil certified to meet or exceed U.S. auto-mobile manufacturer s requirements for Service Classification SE or SF. (Motor oils classified SE or SF will show this designation on the container.) SAE low-40 is recommended for general all-temperature use. Other viscosities shown in the chart may be used when the everage temperature in your area is within the indicated range. 1. Remove the oil filler cap and wipe the dipstick clean. 2. Insert the dipstick into the oil filler neck, but do not screw it in. 3. If the level is low, fill to the top of the oil filler neck with the recommended oil. CAUTION : Running the angina with insufficient oil can cause serious angina damage. FILLER -50 1 1 HOLE -20-10 0 10 20 30 40% Ambient temperature CAP

FUEL Use any regular grade automotive gasoline (unleaded gasoline is preferred) with a pump octane rating of 88 or higher. Never use an oil/gasoline mixture or dirty gasoline. Avoid getting dirt, dust or water in the fuel tank. CAUTION : Gasoline substitutes are not recommended ; they may be harmful to the fuel system components. l Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped. l Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored. l Do not overfill the tank and make sure the filler cap is securely closed after refueling. l Be careful not to spill fuel when refueling. Fuel vapor or spilled fuel may ignite. If any fuel is spilled, make sure the area is dry before starting the engine. Fuel tank capacity : 6.0 lit. (12.7 US pt. 10.6 Imp pt) 1. Check the fuel level. 2. If level is low, fill to the shoulder of the fuel filter. FUEL FILLER CAP FUEL FILTER 9

GASOLINES CONTAINING ALCOHOL If you decide to use a gasoline containing alcohol ( gasohol ), be sure the octane rating is at feast as high as that recommended by Honda. There are two types of gasohol : that containing ethanol, and that containing methanol. Do not use gasohol that contains more than 10% ethanol. Do not use gasoline containing methanol (methyl or wood alcohol) that does not also contain cosolvents and corrosion inhibitors for methanol. Never use gasoline containing more than 5% methanol, even if it has cosolvents and corrosion inhibitors. NOTE : l Fuel system damage or engine performance problems resulting from the use of such fuels are not covered under Power Equipment Warranties. Honda cannot endorse the use of fuels containing methanol since evidence of their suitability is as yet incomplete. l Before purchasing fuel from an unfamiliar station, try to confirm whether the fuel contains alcohol, and to what percentage. If you notice any undesirable operating symptoms after using a gasoline that contains alcohol ; or one that you think contains alcohol, switch to a gasoline that you know does not contain alcohol. 10

5. STARTING THE ENGINE Make sure the AC circuit breaker is OFF position. 1. Turn the fuel valve to the ON position. FUEL 2. Move the choke lever to the CLOSE position. NOTE : Do not use the choke if the engine is warm or the air temperature is high. CHOKE LEVER 11

3, Turn the engine switch to the ON position. ENGINE SWITCH 4. Pull the starter grip lightly until1 resistance is felt, then pull briskly. CAUTION : Do not allow the starter grip to snap beck against the engine. Return it gently to prevent damage to the starter. STARTER GRIP 12

5. As the engine warm up, gently turn the choke lever to OPEN position. CHOKE LEVER 13

6. GENERATOR USE To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy wire between the ground terminal and the ground source. CAUTION : 0 Limit operation requiring maximum power to 30 minutes. For continuous operation, do not excaad the rated power. In either caaa, the total wattage of all appliances connected muat be considered. l Do not exceed the current limit apacified for any one receptacle. l Do not connect the generator to a household circuit. This could caueo the damage to the generator. 1. Turn the voltage selector switch to either position. NOTE : If you turn the switch to 12OV you can use six receptacles for 12OV appliances. If 12OV/24OV is selected, you can use five receptacles for 12OV and one receptacle 240V. GROUND TERMINAL VOLTAGE SELECTOR I I 14

2. Plug in the appliance. 3. Switch on the AC circuit breaker. This generator is equipped with an AVR (Automatic Voltage Regulator) for stable voltage supply. AC CIRCUIT BREAKER I PLUG 15

Oil Alert Syetem The oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls below a safe limit, the Oil Alert system will automatically shut down the engine (the engine switch will remain in the OK position). If the Oil Alert system shuts down the engine, the Oil Alert lamp will flash when you operate the starter, and the engine will not run. If this occurs, add engine oil (P. 8) OIL ALERT LAMP 16

7. STOPPING THE ENGINE To stop the engine in an emergency, turn the engine switch OFF. In normal use : 1. Turn the AC circuit breaker OFF position. AC CIRCUIT BREAKER 2. Turn the engine switch OFF position. ENGINE SWITCH 17

3. Turn the fuel valve OFF position. FUEL VALVE l High altitude operation At high altitude, the standard carburetor air-fuel mixture will be excessively rich. Performance will decrease, and fuel consumption will increase. High altitude performance can be improved by installing a smaller diameter main fuel jet in the carburetor and readjusting the pilot screw. If you always operate the generator at altitudes higher than 6,000 feet above sea level, have your authorized Honda Generator dealer perform these carburetor modifications. Even with suitable carburetor jetting, engine horsepower will decrease approximatery 3.5% for each 1,000 foot increase in altitude. The affect of altitude on horsepower will be greater than this if no carburetor modification is made. CAUTION: Operation of the generator at an altitude lower than the carburetor is jetted for may result in reduced performance, overheating, and serious engine damage caused by an excessively lean air/fuel mixture. 18

8. MAINTENANCE The purpose of the maintenance schedule and adjustment is to keep the generator in the best operating condition. Inspect or service as scheduled in the table below. m Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. The exhaust contains poisonous carbon monoxide gas. CAUTION : Use only genuine HONDA parts or their equivalent. The use of replacement parts which are not of equivalent quality may damage the generator. Maintenance Schedule first Every Every E-V I I -- I E(IGI usa month 3 month 6 month year 200&s. 5o ll. 10&a. 30&a., I Sediment cup Spark plug Spark arrester Valve clearance Fuel tank and strainer Clean Clean-Readjust Clean Check-Readjust Clean 0 (11 fl Check Fuel line (Replace if necessary) J NOTE (1) : Service more frequently when used in dusty areas. (2) : These items should be serviced by an authorized Honda dealer, unless the owner has the proper tools and is mechanically proficient. See the Honda Shop Manual.._ 0 0 I 19

Tool kit The tools supplied are necessary for performing some periodic maintenance, simple adjustments and repairs. Always keep the kit with the generator. c L 1 SCREWDRIVER loxl2mm WRENCH t 0 1 - PLUG WRENCH HANDLE BAR DRIVER HANDLE EII 0 - - TOOL BAG 20

Changing oil Drain the oil while the engine is still warm to assure rapid and complete draining. 1. Remove the drain plug and filler cap, and drain the oil. Retighten the plug securely., 2. Refill with the recommended oil (see P. 8) and check the level. I ENGINE OIL CAPACITY : 1.11Il.16 US qt. 1.94 Imp pt) FILLER CAP DRAIN- PLUG CAUTION: Used motor oil may cause skin cancer if repeatedly left in contact with the skin for prolonged periods. Although this is unlikely unless you handle used oil on a daily basis, it is still advisable to throughly wash your hands with soap and water as soon as possible &ter handling used oil. NOTE: Please dispose of used motor oil in a manner that is compatible with the environment. We suggest you take it in a sealed container to your local service station for reclamation. Do not throw it in the trash or pour it on the ground. 21

Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. malfunction, service the air cleaner regularly. To prevent carburetor Never usa gasoline or low flash point solvents A fire or explosion could result. for clean the air cleaner element. CAUTION : Never run the generator without the air cleaner. Rapid engine wear may result. 1. Remove the wing nut and the air cleaner cover. Remove the elements and separate them. Carefully check both elements for holes or tears and replace if damaged. 2. Foam element : Wash the element in a solution of household detergent and warm water, then rinse thoroughly, or wash in nonflammable or high flash point solvent. Allow the element to dry thoroughly. Soak the element in clean engine oil, and squeeze out the excess oil. The engine will smoke during initial start-up if too much oil is left in the foam. 3. Paper element: Tap the element lightly several times on a hard surface to remove excess dirt, or blow compressed air through the filter from the inside out. Never try to brush the dirt off; brushing will force dirt into the fibers. Replace the paper element if it is excessively dirty. WING NUT AIR CLEANER COVER w ---,a PAPER ELEMENT 22 FOAM ELEMENT

Sediment cup cleaning Turn the fuel valve to OFF. Remove the sediment cup and O-ring, and wash them in nonflammable or high flash point solvent. Dry them throughly, and reinstall, securely. Turn the fuel valve ON, and check for leaks. FUEL VALVE.wiiY.kFY SEDIMENT CUP SEDIMENT &lp 23

Spark plug service Recommended spark plug ; BPRSES (NGK) WlGEPR-U (ND) CAUTION : Never use a spark plug of incorrect heat range. lo ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 1. Remove the spark plug cap, and use a spark plug wrench to remove the plug. lzmu!q If the engine has been running, the muffler will be very hot. Be careful not to touch the muffler. PLUG WRENCH 2. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused. 3. Measure the plug gap with a feeler gauge. The gap should be O-7-0.8 mm (0.028-0.031 in) 0.7-0.8mm (0.628-0.031 in) 24

4. Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 5. After the spark plug is seated, tighten with a spark plug wrench to compress the washer. NOTE : If installing a new spark plug, tighten l/2 turn after the spark plug seats to compress the washer. If reinstalling a used spark plug, tighten l/8-1 /4 turn after the spark plug seats to compress the washer. CAUTION : The spark plug must be securely tightened. An improperly tightened spark plug can become very hot and may damage the engine. 25

Spark arrester maintenance c!imm If the engine has been running, the muffler will be very hot. Allow it to cool before proceeding. 1. Remove the eight 5 mm screws @ from the muffler protector @, and remove the muffler protector. 2. Remove the 4mm screw @from the spark arrester 0, and remove the spark arrester from the muffler 0. 3. Use a brush to remove carbon deposits from the spark arrester screen. CAUTION : Be careful not to damage the spark arrester screen. SPARK ARREST SCREEN / NOTE : The spark arrester must be free of breaks and holes. Replace, if necessary. 4. Install the spark arrester and the muffler in the reverse order of disassembly. 26

9. TRANSPORTING/STORAGE CAUTION : When transporting the generator, turn the engine switch and oil alert switch OFF and keep the generator level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite. I Before storing the unit for an extended period : 1. Assure the storage area is free of excessive hunmidity and dust. 2. Drain the fuel. a. With the fuel valve OFF, remove and empty the sediment CUP. b. Turn the fuel valve ON and drain the gasoline in the fuel tank into a suitable container. c. Replace the sediment cup and tighten securely. FUEL VALVE SEDIMENT CUP 27

d. Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. 3. Change the engine oil. 4. Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder. Crank the engine several revolutions to distribute the oil, then reinstall the spark plug. 5. Pull the starter rope slowly until1 resistance is felt. Continue pulling untjl the notch on the starter pulley aligns with the hole on the recoil starter. (see illustration below.) At this point, the intake and exhaust valves are closed, and this will help to protect the engine from internal corrosion. Align the notch on the starter pulley with the hole at the top of the recoil euerter. 8. Cover the engine to keep out dust. 28

10. TROUBLESHOOTING A. When the engine will not start: 1. Is the engine switch on 1 2. Does the oil alert lamp flash when the starter is pulled? 3. Is there enough fuel? 4. Are all loads disconnected from the AC receptacles? 5. Is there a spark at the spark plug? a.remove the spark plug cap. Clean any dust from around the spark plug base, then remove the spark plug. b.lnstall the spark plug in the plug cap. c.turn the engine switch on. d.grounding the side electrode to any engine ground, pull the recoil starter to see if sparks jump across the gap. m Be sure there is no spilled fuel near the spark plug. Spilled fuel may ignite. Perform this test in a well ventilated area. e.lf there are no sparks, replace the plug. f.if the new spark plug does not spark, take the generator Honda dealer. to an authorized OIL AL,ERT IAMP ENGINE SWITCH 29

6. Is gasoline reaching the carburetor? To check, place a suitable container under the drain, turn the engine switch on and loosen the drain screw. Fuel should flow out freely. If OK, try to start the engine according to the instructions. DRAIN SCREW 7. If the engine still does not start,.take the generator to an authorized Honda dealer. c!!zma If any fuel is spilled, make sure the area around the spark plug and the generator is dry before starting the engine. Fuel vapor or spilled fuel may ignite. B. When the engine starts but stops immediately ; 1. Check the oil alert lamp. If the oil alert lamp flashes when the starter is pulled, check the engine oil level end fill with the recommended oil. 2. Re-start the engine. C. No electricity at the AC receptacles : 1. Is the AC circuit breaker on? 2. Check the electrical appliance or equipment for any defects. 30

11. SPECIFICATIONS Dimensions Model Power equipment description code Length x Width x Height Dry weight EG3500X EA6 655 x 460 x 460 mm (25.8 x 18.1 x 18.1 in) 53.5 kg (117.9 lb) Engine Model GX240 Engine type 4-stroke, overhead valve, single cylinder Displacement 242 cc (14.8 cuin) (Bore x Storke) (73 x 58 mm (2.9 x 2.3 in)) Max. output 8.0 HP/3600 rpm Max. torque 1.7 kg-m (12.3 ft-lb)/2500 rpm Fuel consumption 230 g/hph (0.7 Ib/HPh) Cooling system Forced air Ignition system Transistorized magneto PTO shaft rotation Counterclockwise Generator Model Type AC output EG3500X Rated voltage 120 V/240 V Rated frequency 60 Hz Rated ampere 25/12.5 A Rated output _ 3.0 kva (3000 W) Maximum output 3.5 kva (3500 W) A 31

12. WIRING DIAGRAM I r _._.-.--.-. -...=I 1!! 32 W 1 WHITE 1 Gr 1 GRAY I

13. WARRANTY SERVICE Owner Satisfaction Your satisfaction and goodwill are important to your dealer and to us. All Honda warranty details are explained in the Distributor s Limited Warranty. Normally, any problems concerning the product will be handled by your dealer s service department. If you have a warranty problem that has not been handled to your satisfaction, we suggest you take the following action: l l Discuss your problem with a member of dealership management. Often complaints can be quickly resolved at that level. If the problem has already been reviewed with the Service Manager, contact the owner of the dealership or the General Manager. If your problem still has not been resolved to your satisfaction, contact the Customer Relations Department of American Honda Motor Co., Inc. American Honda Motor Co., Inc. Customer Relations Department P.O. Box 420 Gardena, California 90247-0842 Telephone: (2 13) 604-2400 We will need the following information in order to assist you: - Your name, address, and telephone number - Product model and serial number - Date of purchase - Dealer name and address - Nature of the problem After reviewing all the facts involved, you will be advised of what action can be taken. Please bear in mind that your problem will likely be resolved at the dealership, using the dealer s facilities, equipment, and personnel, so it is very important that your initial contact be with the dealer. Your purchase of a Honda product is greatly appreciated by both your dealer and American Honda Motor Co., Inc. We want to assist you in every way possible to assure your complete satisfaction with your purchase. 33

Current customer service contact information: United States, Puerto Rico, and U.S. Virgin Islands: Honda Power Equipment dealership personnel are trained professionals. They should be able to answer any question you may have. If you encounter a problem that your dealer does not solve to your satisfaction, please discuss it with the dealership's management. The Service Manager or General Manager can help. Almost all problems are solved in this way. If you are dissatisfied with the decision made by the dealership's management, contact the Honda Power Equipment Customer Relations Office. You can write: American Honda Motor Co., Inc. Power Equipment Division Customer Relations Office 4900 Marconi Drive Alpharetta, GA 30005-8847 Or telephone: (770) 497-6400 M-F, 8:30 am - 7:00 pm EST When you write or call, please provide the following information: Model and serial numbers Name of the dealer who sold the Honda power equipment to you Name and address of the dealer who services your equipment Date of purchase Your name, address, and telephone number A detailed description of the problem

34 NOTE

NOTE 35

NOTE