Parametric Study on Flow and Heat Transfer Performance of Multi-Flow Spiral-Wound Heat Exchanger

Similar documents
Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

COMPUTATIONAL ANALYSIS TO MAXIMIZE THE HEAT TRANSFER RATE OF DOUBLE TUBE HELICAL COIL HEAT EXCHANGER

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

SOLAR FLAT PLATE COLLECTOR HEAT TRANSFER ANALYSIS IN THE RAISER WITH HELICAL FINS Mohammed Mohsin Shkhair* 1, Dr.

Experimental Investigation of the Heat Transfer in a Feedwater Preheater for the Decarbonizing Steam Generator

IJESR/Oct 2012/ Volume-2/Issue-10/Article No-12/ ISSN International Journal of Engineering & Science Research

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

Aerodynamic Characteristics of Sedan with the Rolling Road Ground Effect Simulation System

Adjustment Performance of a Novel Continuous Variable Valve Timing and Lift System

CFD analysis of heat transfer enhancement in helical coil heat exchanger by varying helix angle

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

Heat Transfer in Rectangular Duct with Inserts of Triangular Duct Plate Fin Array

Prediction of Thermal Deflection at Spindle Nose-tool Holder Interface in HSM

Modal Analysis of Automobile Brake Drum Based on ANSYS Workbench Dan Yang1, 2,Zhen Yu1, 2, Leilei Zhang1, a * and Wentao Cheng2

Flow mechanism and heat transfer enhancement in longitudinal-flow tube bundle of shell-and-tube heat exchanger

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

Numerical Simulation of the Thermoelectric Model on Vehicle Turbocharged Diesel Engine Intercooler

ENHANCEMENT OF HEAT TRANSFER RATE AND REDUCTION OF SHELL SIDE PRESSURE DROP IN HELIX HEAT EXCHANGER WITH CONTINUOUS HELICAL BAFFLES

51. Heat transfer characteristic analysis of negative pressure type EGR valve based on CFD

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

Chapter 7: Thermal Study of Transmission Gearbox

Clearance Loss Analysis in Linear Compressor with CFD Method

Theoretical and Experimental Investigation of Compression Loads in Twin Screw Compressor

Effect of Stator Shape on the Performance of Torque Converter

Collaborative Innovation Center of Electric Vehicles in Beijing, Pingleyuan, No. 100, Beijing , China 3

[Type text] [Type text] [Type text] Zhang Zenglian 1 School of Automobile and Traffic Engineering, Jiangsu University, Zhenjiang,

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

Thermal Analysis of Shell and Tube Heat Exchanger Using Different Fin Cross Section

Numerical Analysis of Compact Heat Exchanger for Flow Distribution

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

Analysis of Air Flow and Heat Transfer in Ventilated Disc Brake Rotor with Diamond Pillars

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

Research and Development of Mechanically Adjustable Fluid Viscous Damper Dan-Feng SONG*, Yong-Jin LU

Fluid-Structure Interaction Heat Transfer of Piston with Consideration of Oil Oscillating Cooling and In-Cylinder Local Heat Transfer

NUMERICAL INVESTIGATION OF PISTON COOLING USING SINGLE CIRCULAR OIL JET IMPINGEMENT

CFD Analysis of Oil Discharge Rate in Rotary Compressor

COMPUTATIONAL FLOW MODEL OF WESTFALL'S 2900 MIXER TO BE USED BY CNRL FOR BITUMEN VISCOSITY CONTROL Report R0. By Kimbal A.

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

Reaction Parameters and Energy Optimisation for Biodiesel Production Using a Supercritical Process

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

Comparative Numerical Analysis of Straight and Conical Coil Heat Exchanger

The Optimal Design of a Drum Friction Plate Using AnsysWorkbench

Study on Flow Characteristic of Gear Pumps by Gear Tooth Shapes

International Journal of Engineering Research and General Science Volume 5, Issue 3, May-June, 2017 ISSN

EFFECT OF SURFACE ROUGHNESS ON PERFORMANCE OF WIND TURBINE

China. Keywords: Electronically controled Braking System, Proportional Relay Valve, Simulation, HIL Test

ADVANCES in NATURAL and APPLIED SCIENCES

Review on Comparative Study between Straight Tube Heat Exchanger and Helical Coil Heat Exchanger

Scroll Compressor Oil Pump Analysis

NUMERICAL INVESTIGATION OF FLUID FLOW AND HEAT TRANSFER CHARACTERISTICS ON THE AERODYNAMICS OF VENTILATED DISC BRAKE ROTOR USING CFD

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

CYLINDER HEAD FEM ANALYSIS AND ITS IMPROVEMENT

Effects of Dilution Flow Balance and Double-wall Liner on NOx Emission in Aircraft Gas Turbine Engine Combustors

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

Design and Numerical Parametric Study of Fractal Heat Exchanger

Influence of Ground Effect on Aerodynamic Performance of Maglev Train

Single-phase Coolant Flow and Heat Transfer

Automation of Optimal Design of Air Preheater s Corrugated Heating Elements using CFD

Research on Optimization of Bleed Air Environment Control System of Aircraft Xin-ge WANG, Han BAO* and Kun-wu YE

NUMERICAL ANALYSIS OF HELICALLY COILED HEAT EXCHANGER USING CFD TECHNIQUE

Thermal Stress Analysis of Diesel Engine Piston

Electrostatic Ignition Hazards Associated with the Pneumatic Transfer of Flammable Powders through Insulating or Dissipative Tubes and Hoses

INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS OF CIRCULAR AND DIAMOND PILLARED VANE DISC BRAKE ROTOR USING CFD

CFD ANALYSIS ON LOUVERED FIN

Analysis on natural characteristics of four-stage main transmission system in three-engine helicopter

Abstract In this study the heat transfer characteristics inside a rectangular duct with circular, rectangular, drop

University of Huddersfield Repository

CFD ANALYSIS OF FLUID FLOW AND HEAT TRANSFER IN A SINGLE TUBE-FIN ARRANGEMENT OF AN AUTOMOTIVE RADIATOR

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

Investigation of converging slot-hole geometry for film cooling of gas turbine blades

International Journal of World Research, Vol: I Issue XXXVII, January 2017 Print ISSN: X

NUMERICAL SIMULATION OF HELICAL COIL TUBE IN TUBE HEAT EXCHANGER WITH BAFFLES

Chapter 2 Dynamic Analysis of a Heavy Vehicle Using Lumped Parameter Model

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Investigation for Flow of Cooling Air through the Ventilated Disc Brake Rotor using CFD

This presentation highlights the work done in developing a simple demo model

Numerical Simulation on Erosion of Drain Valve Liangliang Xu1,a, Zhengdong Wang2,b, Xinhai Yu3,c, Cong Zeng4,d

Modeling and Fluid Flow Analysis of Wavy Fin Based Automotive Radiator

Research on Collision Characteristics for Rear Protective Device of Tank Vehicle Guo-sheng ZHANG, Lin-sen DU and Shuai LI

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

A Study on Performance Enhancement of Heat Exchanger in Thermoelectric Generator using CFD

Numerical research on hydrodynamic characteristics of end cover of pressure exchanger

The Heating Mode Of Cable Transformer With Cooling System

INTERCOOLER FOR EXTREMELY LOW TEMPERATURES OF CHARGING

ANALYSIS OF SURFACE CONTACT STRESS FOR A SPUR GEAR OF MATERIAL STEEL 15NI2CR1MO28

Finite Element Analysis Of Drum Brake Assembly

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

Parametric Modeling and Finite Element Analysis of the Brake Drum Based on ANSYS APDL

Analysis of the Influence of Piston Cooling Cavity on Its. Temperature Field

Cooling of plastic on metallic mandrel

Comparison of Heat transfer Enhancement in Tube in Tube heat exchanger using Different Turbulent Generator.

Department of Mechanical Engineering, D Y Patil College of Engineering, Akurdi, Pune , Savitribai Phule Pune University, India

THERMAL ANALYSIS OF SHELL AND TUBE HEAT EXCHANGER

Oil-water separation efficiency and fluid mechanics of a hydrocyclone Xiangzhong Fan1, a

Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

Transcription:

319 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 39, 2014 Guest Editors: Petar Sabev Varbanov, Jiří Jaromír Klemeš, Peng Yen Liew, Jun Yow Yong Copyright 2014, AIDIC Servizi S.r.l., ISBN 978-88-95608-30-3; ISSN 2283-9216 The Italian Association of Chemical Engineering www.aidic.it/cet DOI:10.3303/CET1439054 Parametric Study on Flow and Heat Transfer Performance of Multi-Flow Spiral-Wound Heat Exchanger Gaopeng Zhang, Xing Lu, Xueping Du, Min Zeng, Qiuwang Wang* Key Laboratory of Thermo-Fluid Science and Engineering, Ministry of Education, Xi an Jiaotong University, Xi an, 749, China wangqw@mail.xjtu.edu.cn The multi-flow spiral-wound heat exchangers are widely used in industrial applications, but the mechanism of flow and heat transfer has not been clarified yet. A three-dimensional model is developed based on the FLUENT software in this study. The effects of different geometrical factors, such as the space bar thickness and the tube pitch in the first layer, on flow and heat transfer performance are numerical studied. It is found that as the space bar thickness increases, the Nusselt number and the pressure loss per unit length both decreases and the similar trend is obtained as the tube pitch increases. Meanwhile, once the geometrical factors and the Reynolds number in the tube-side are determined, the Nusselt number and pressure loss per unit length in the tube-side keep constant generally, regardless of the change of Reynolds number in the shell-side. 1. Introduction Due to its high compactness and heat transfer coefficient under multi-stream condition, spiral-wound heat exchangers are widely used in industrial applications, such as air separation, process plants, nuclear industry, and refrigeration. Although this kind of heat exchanger has been put into use, the mechanism of flow and heat transfer on shell side is still not clarified yet and the method how to calculate the heat transfer coefficient and friction accurately is still being studied. Based on the heat transfer coefficient and pressure drop formulas when the fluid flows across the straight tube bank, Gilli (1989) deduced the heat transfer coefficient and pressure drop formulas for fluid flows outside the coiled tube bundles. Neeraas et al. (4) performed an experimental investigation to study the heat-transfer and pressure drop characteristics on the shell-side of spiral-wound heat exchanger, using different working fluid (methane, ethane and propane, etc.) in different phase states. Ghorbani et al. (2010) implemented an experimental study on mixed convective heat transfer under various Reynolds number, curvature ratio and pitch. Moawed (2011) investigated the influence of various curvature and torsion rate on outer-side heat transfer coefficient. The experiment model was a vertical heat exchanger whose coil was wound by hollow pipe inserted with electric heating wire. Picón-Núñez et al. (2012) developed the graphical design method originally applied for shell and tube heat exchangers and extended to the case of spiral heat exchangers which have similar and simpler structure than the multilayer SWHEs. The study on spiral-wound heat exchanger mainly consists of experimental method and two-dimension numerical simulation. In addition, almost all of the research subjects are single-stream spiral-wound heat exchanger and few papers report the flow and heat transfer performance of multi-stream spiral-wound heat exchanger. Meanwhile, due to its complex geometric structure and flow and heat transfer mechanism, there is no study report the three-dimension numerical study on multi-stream spiral-wound heat exchanger. In this study, a three-dimensional model is developed based on the FLUENT software. The effects of different geometrical factors, such as the space bar thickness, the tube pitch in the first layer and the tube external diameter, on flow and heat transfer performance are numerical investigated. Please cite this article as: Zhang G., Lu X., Du X., Zeng M., Wang Q., 2014, Parametric study on flow and heat transfer performance of multi-flow spiral-wound heat exchanger, Chemical Engineering Transactions, 39, 319-324 DOI:10.3303/CET1439054

320 Figure 1: Element of a spiral-wound heat exchanger 2. Characteristics of multi-flow spiral-wound heat exchanger Figure 1 shows the typical element of a spiral-wound heat exchanger. It can be seen that the structure of multi-flow spiral-wound heat exchanger is quite complicated. In the cylinder with space bar around, the central coil wrapped around the central cylinder using the space bar fixed. The coils' winding direction is opposite between adjacent layers. The study subject in this paper is a three-flow spiral-wound heat exchanger, there are two streams in the tube side and the flow directions of the two streams are opposite. It consists of five main geometric factors which affect the flow and heat transfer. They are the central cylinder diameter D, the tube external diameter D, the tube pitch in the first layer Pl t 1, the space bar core thickness B and the helical layer number C. 3. Computation model 3.1 Physical model To simplify the simulation, the following assumptions are made in this study: 1) The thermal properties of fluid in shell-side fluid are kept constant. 2) The flow and heat transfer are steady state and laminar. 3) The heat loss between heat exchanger and the environment is neglected. 4) The natural convection caused by the variation of fluid density is neglected. In order to avoid the backflow in the end, prolongations are used at the inlet and outlet. The physical model for numerical simulation of spiral-wound tube heat exchanger is showed in Figure 2. 3.2 Type font and type size The governing equations for continuity, momentum and energy are shown as follows. ui x i 0 (1) u u p u u i j j i t xi xi x j xi x j (2) ut i t T xi x i Pr Prt x i (3) The velocity at inlet of shell side is assumed as uniform. Pressure-outlet condition is prescribed at the outlet. The tube wall temperature is constant. The walls of center tube and shell tube are adiabatic. The above equations along with the specified boundary conditions are solved numerically using a finite-volume method based on the ANSYS FLUENT software platform. The first order upwind scheme is used to treat the convection terms. The SIMPLEC method is adopted for pressure and velocity coupling. Grids in the computational region are unstructured generated by ANSYS ICEM. In order to obtain more precise

Nu dp m /(Pa/m) 321 Figure 2: Physical model simulation results and make the detailed analysis, the grids of specific zones including walls of the tubes, the central cylinder, the inlet and outlet are increased appropriately and sufficiently. 3.3 Numerical verification and model validation Three kinds of grid systems have been established to test the effect of grid number. Figure 3 shows the variation of the average Nusselt number and pressure drop with different numbers of grid points. When the grid mesh number changes from 1,397, to 1,260,000, the average Nusselt number varies from 235.07 to 229.73 (i.e., 2 %), pressure drop per unit length from 1,338 to 1,241 (i.e., 7.3 %). The average Nusselt number and pressure drop per unit length varies slightly when the number of grid points reaches 1,137,771, which is used for taking both the accuracy and convergence rate into account. In order to validate the numerical model employed in the paper, the numerical results are compared with the experimental results in (Neeraas et al., 4) where the structures were exactly the same as the model size in the present study. Table 1 (Neeraas et al., 4) shows the parameters of the inlet. Table 1: Model operating conditions Case P in/bar T in/ v in/m s -1 1 13.664-11.87 2.38 2 13.682-11.67 4.65 3 13.501-12.20 7.06 4 13.659-13.82 8.07 Based on the experimental working conditions in (Neeraas et al., 4), three kinds of turbulent models (Standard k-, RNG k- and Realizable k- ) are adopted. As shown in Figure 4, the heat transfer coefficient predicted by RNG k- model agrees the best with the experimental. Therefore, the RNG k- model is adopted in the following simulation work. 280 260 Nu p/l 1350 1 1250 1 240 1150 220 1 1050 1.10 10 5 1.15 10 5 1.20 10 5 1.25 10 5 1.30 10 5 Grid number 1.35 10 5 1.40 10 5 0 Figure 3: Grid independence test 3.4 Boundary conditions and physical property The working fluid in this study is methanol. The velocity-inlet condition is prescribed at the inlet. The temperature of the fluid in the shell side inlet is 223 K and the temperature of the fluid in the tube side is 238 K and 253 K. Pressure-outlet condition is prescribed at the outlet. The coupling heat transfer is

Nu Nu dp m /(Pa/m) 322 calculated using fluid area and solid area coupling solution. The thickness of the tube is 2 mm. The walls of both the central and external cylinders are adiabatic. 5000 500 Experimental data of Neeraas et al. (4) Experimental data of Neeraas et al. (4) 450 Standard k- Standard k- 4000 RNG k- 400 RNG k- 350 Realizable Realizable k- k- 0 250 150 50 0.0 2.0x10 4 4.0x10 4 6.0x10 4 8.0x10 4 1.0x10 5 Figure 4: Model validation Re 0 0 0 2.0x10 4 4.0x10 4 6.0x10 4 8.0x10 4 1.0x10 5 Re 4. Numerical simulation results and discussion 4.1 Effects of thickness of space bar The thickness of space bar determines the shell-side area in which fluids pass through. Large space bar thickness means large flow area channel, as shown in Figure 1. In the case of central cylinder diameter is 80 mm, tube external diameter is 12 mm, the number of layer is 1, the tube pitch in the first layer is 17 mm, and we numerical study the effects of thickness of space bar on flow and heat transfer performance. Figure 5 shows effect of space bar on Nu number and pressure drop. 600 500 400 v shell =1.4 m/s,v tube1 =0.8 m/s,v tube2 =1 m/s C=1,dPl 1 =5 mm,d t =12 mm,d core =80 mm Nu shell Nu tube1 Nu tube2 2 3 4 B/mm / dp m (KPa/m) 6 4 2 0 v shell =1.4 m/s,v tube1 =0.8 m/s,v tube2 =1 m/s C=1,dPl 1 =5 mm,d t =12 mm,d core =80 mm dpl m shell dpl m tube1 dpl m tube2 2 3 4 B/mm Figure 5: v shell=1.4 m/s, effect of space bar on Nu number and pressure drop per length From Figure 5 we can see that the heat transfer coefficient and pressure drop per length decrease with the increase of space bar thickness. From left to right in Figures 6-7 are the temperature and pressure distribution in shell side with space bar thickness is 2 mm, 3 mm and 4 mm. It could be found clearly that smaller thickness of space bar means better heat transfer performance and higher pressure drop. As the thickness of the space bar increases, the flow channel of the fluid becomes wider and the spacing between adjacent layers becomes larger which lead to the decreasing of the average flow velocity at the same time. So the thin space bar means narrow fluid flow channel and adequate fluid mixing. As a result, the heat transfer performance becomes better as well as the pressure loss becomes larger at the same time. So it is suitable to use neither too thick nor too thin space bar in the reality of designing a spiralwound heat exchanger and the space bar with the thickness of 2~3 mm is recommended. 4.2 Effects of tube pitch in the first layer As shown in Figure 1, the tube pitch refers to the longitudinal distance between the centres of adjacent tubes in the same layer. When other factors keep constant, the geometric dimension of tube pitch determines the tube winding angle, and the big tube pitch means big winding angle. In the case of central cylinder diameter is 80 mm, the tube external diameter is 12 mm, the number of layer is 1, the thickness of

Nu dpm(kpa/m) P(KPa) space bar is 2 mm, and the effects of tube pitch in the first layer on flow and heat transfer performance are numerically studied. 323 Figure 6: v shell=1.4 m/s, temperature distribution in shell side with different space bar thickness Figure 7: v shell=1.4 m/s, pressure distribution in shell side with different space bar thickness 500 450 400 v shell =1.4 m/s,v tube1 =0.8 m/s,v tube2 =1 m/s C=1,B=2 mm,d t =12 mm,d core =80 mm Nu shell Nu tube1 Nu tube2 150 50 dpm shell dpm tube1 P tube2 dpm tube2 P shell P tube1 60 50 40 30 150 4 6 8 10 dpl 1 /mm 6 4 2 v shell =1.4 m/s,v tube1 =0.8 m/s,v tube2 =1 m/s C= 1,B=2 mm,d 0 t =12 mm,d core =80 mm 4 6 8 10 dpl 1 /mm 10 8 6 Figure 8: v shell=1.4 m/s, effect of tube pitch in the first layer on Nu number and pressure drop From Figure 8 we can see that the heat transfer coefficient and the pressure drop decrease with the increase of tube pitch in the first layer. From left to right in Figures 9-10 are the temperature and pressure distribution in shell side with tube pitch in the first layer is 17 mm, 19 mm and 22 mm. We could see clearly that smaller tube pitch in the first layer means better heat transfer performance and more pressure drop. This phenomenon could be explained as follows: when the tube pitch in the first layer increases, the gap among tube bundles becomes large which make less fluid keep stagnant and the pressure decreases correspondingly. Meanwhile, the flow resistance that restricts the fluid flows towards adjacent layers increases, which lead to the tendency that the fluid flows across the tube bundles is weakened. As a result, the Nusselt number and the heat transfer performance decreases. So small tube pitch in the first layer brings enhanced heat transfer performance as well as more pressure loss. It is suitable to choose neither too large nor too small tube pitch in the first layer in designing a spiral-wound heat exchanger and the tube pitch in the first layer that making the winding angle between 5 o ~15 o is recommended.

324 Figure 9: v shell=1.4 m/s, temperature distribution in shell side with different tube pitch in the first layer Figure 10: v shell=1.4 m/s, temperature distribution in shell side with different tube pitch in the first layer 5. Conclusion A three-dimensional numerical simulation model for multi-flow spiral-wound heat exchanger is developed and validated in the present study. The effects of some geometry parameters on the flow and heat transfer are investigated in detail. The main conclusions are drawn as follows. The Nusselt number and pressure loss per length both decrease with the increase of thickness of space bar. As the tube pitch in the first layer increases, the Nusselt number and the pressure loss both decreases. Acknowledgments This work was supported by the Natural Science Foundation of China (Grant No. 51276139). References Editorial Committee., 1989, The Latest Heat exchanger design calculation and heat transfer strengthening and quality inspection standards practical manual. The Northern Industrial Press, Beijing, China (in Chinese). Neeraas B.O.,Fredheim A.O., Aunan B., 4. Experimental shell-side heat transfer and pressure drop in gas flow for spiral-wound LNG heat exchanger, International Journal of Heat and Mass Transfer, 47,353-361, DOI: 10.1016/S0017-9310(03)00400-9. Ghorbani N., Taherian H.,Gorji M., Mirgolbabaei H., 2010. Experimental study of mixed convection heat transfer in vertical helically coiled tube heat exchangers, Experimental Thermal and Fluid Science, 34,900-905, DOI: 10.1016/j.expthermflusci.2010.02.004. Moawed M., 2011. Experimental study of forced convection from helical coiled tubes with different parameters, Energy Conversion and Management, 52, 1150-1156,DOI:1016/j.enconman.2010.09.009. Picon-Nunez M., Polley G.T., Riesco-Avila J.M., 2012. Design space for the sizing and selection of heat exchangers of the compact type, Chemical Engineering Transactions, 29, 217-222, DOI:10.3303/CET1229037.