A Review of DC/DC Converter De-rating Practices

Similar documents
Features. Figure 1. EFIL-28 Connection Diagram

Thermal Considerations: Assuring Performance of Vicors Maxi, Mini, Micro Series High-Density DC-DC Converter Modules

BASIC ELECTRICAL MEASUREMENTS By David Navone

Demystifying the Use of Frameless Motors in Robotics

Implications of Digital Control and Management for a High Performance Isolated DC/DC Converter

Model Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power

Implications of. Digital Control. a High Performance. and Management for. Isolated DC/DC Converter. Technical Paper 003.

Implications of. Digital Control. a High Performance. and Management for. Isolated DC/DC Converter. Technical Paper 003.

AUML Varistor Series. Surface Mount Varistors

Using the wrong voltage and/or low current can cause a variety of problems:

4707 DEY ROAD LIVERPOOL, NY PHONE: (315) FAX: (315) M.S. KENNEDY CORPORATION MSK Web Site:

BPS-v4 Technical Reference S-CAB 11 volt, 1 amp battery power supply

MORE THAN PRESSURE SPRING RATE STAGGER CROSS WEIGHT CHANGES

Not for New Design 10 WATT WD DUAL LOW INPUT SERIES DC/DC CONVERTERS. Features

Technical Note. Management of Sealed Lead Acid Batteries in Reliable Small DC Standby Power Supply Systems

20th. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. Do You Need a Booster Pump? Is Repeatability or Accuracy More Important?

How to: Test & Evaluate Motors in Your Application

Maxi and Mini DC-DC Converter Evaluation Board

Why Is My PV Module Rating Larger Than My Inverter Rating?

Features. Figure 1. Block Diagram. Figure 2. Input - Output DC Voltage

What Everyone Should Know About Automatic Grease Lubricators

DC/DC power modules basics

Pump ED 101. Variable, Fixed Speed Control - - Float Switch Activation. Introduction

DC/DC Power Modules Basics

VI Chip BCM Bus Converter Thermal Management

Application Note AN-1203

Working Principle of Power Saver as per Manufacture:

Temperature controller. Side. Vac 3. Typically. Temperature controller. Side. Vac Driving SSR. Temperature controller. Resistor. Vac.

EMI INPUT FILTER 28 VOLT INPUT

In order to discuss powerplants in any depth, it is essential to understand the concepts of POWER and TORQUE.

Technical Guide No. 7. Dimensioning of a Drive system

Heat Pipe Selection Guide Heat Pipe Introduction

EMaSM. Principles Of Sensors & transducers

DPX30-xxSxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; 3.3 to 28 VDC Single Output; 30 Watts Output Power

Diversion Manual (Section 6.0): 31 March 03

Overcurrent protection

CBAM Load Share (LSL) Series

Edwards Engineering Corporation

DPX30-xxDxx DC-DC Converter Module 9.5 ~ 18 VDC and 18 ~ 36 VDC and 36~ 75 VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

PS-1X Series Power Supply Unit Information & User Manual

DPX30-xxWSxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; 3.3 to 28VDC Single Output 30 Watts Output Power

Application Information

DPX30-xxWDxx DC-DC Converter Module 10 ~ 40VDC, 18 ~ 75VDC input; ±12 to ±15 VDC Dual Output; 30 Watts Output Power

DTC P0A04 - Open Wiring Fault

55 Watt K Triple Series DC/DC Converters

NOT RECOMMENDED FOR NEW DESIGNS

Features. Continuous AUML Series Units. ) 1.5 to 25 J Jump Start Capability (5 minutes), (V JUMP. ) 48 V Operating Ambient Temperature Range (T A

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

DPX15-xxWDxx Dual Output: DC-DC Converter Module 9.5 ~ 36VDC, 18 ~ 75VDC input; ±5 to ±15 VDC Dual Output; 15 Watts Output Power

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

LANC245.1W12. DC/DC Converter VDC Input 5.1 VDC Output at 2.4A. Features:

VEHICLE TOWING SAFETY

Investigation of Radiators Size, Orientation of Sub Cooled Section and Fan Position on Twin Fan Cooling Packby 1D Simulation

DPD72PG1 BILEVEL STEP MOTOR DRIVER PACK With RAMPING PULSE GENERATOR

Battery Capacity Versus Discharge Rate

Common Mistakes in Battery Pack Development (And how to avoid them) By Katherine Mack, Rose Electronics

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

The Search for Cooler, High Power & Scalable POL Regulators in Small Footprint Packages Yields Results

Lecture 1. Introduction to Power Electronics

Application Notes. Calculating Mechanical Power Requirements. P rot = T x W

GatesFacts Technical Information Library Gates Compass Power Transmission CD-ROM version 1.2 The Gates Rubber Company Denver, Colorado USA

Features. Applications

EE30181A DC Electronic Load 300 Watt

Optimizing Battery Accuracy for EVs and HEVs

Application Note 103 January LTM4600 DC/DC µmodule Regulator Thermal Performance Eddie Beville, Jian Yin AN103-1

Asia-Pacific Europe, Middle East North America Bel Power Solutions, Inc. BCD.

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1061A LINEAR LI-ION BATTERY CHARGER WITH DUAL SYNCHRONOUS BUCK REGULATOR

APPLICATION NOTE TESTING PV MICRO INVERTERS USING A FOUR QUADRANT CAPABLE PROGRAMMABLE AC POWER SOURCE FOR GRID SIMULATION. Abstract.

Cooling System Modifications... 2

Thanks for Ordering The Kawasaki KLX Adjustable Lowering Kit From

PT8A mA Li-ion/Polymer Battery Charger

Silvertel. POE Thermal Consideration. Introduction. Definition

SQ24 Series DC-DC Converter Data Sheet VDC Input; Standard Outputs from 1-12 VDC

Exercise 3. Battery Charging Fundamentals EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Charging fundamentals

Waste Heat Recovery from an Internal Combustion Engine

DCMCW60 SERIES FEATURES

MOTORS, VOLTAGE, EFFICIENCY AND WIRING. A Deeper Understanding

APPLICATION NOTE Calculating temperature rise when mounting remote access units into Oberon s Model 1074 Ceiling Zone enclosures

Efficiency Model dependant 86 ~ 88% Isolation. Isolation Cap. Switching Freq. Safety. Case Material Base Material Potting.

The benefits of using non-isolated DC-DC converters

Accurate and available today: a ready-made implementation of a battery management system for the new 48V automotive power bus

Thermal Characterization of Flex Power Modules

Cooler Bellhousing KPV series

Commissioning chilled water TES systems

AGN 021 Alternator Life Expectancy

Data Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?

25 to 30 Watt XW Single Series DC/DC Converters

Extracting Tire Model Parameters From Test Data

The Pacifier Battery Powered Bottle Warmer

AT1084 5A Low Dropout Positive Voltage Regulator

CHASSIS DYNAMICS TABLE OF CONTENTS A. DRIVER / CREW CHIEF COMMUNICATION I. CREW CHIEF COMMUNICATION RESPONSIBILITIES

Producing Light from Stoves using a Thermoelectric Generator

Optimising Reliability in LED Lighting Systems. Presented by: John Hesketh of LPA-Excil Electronics At Railway Interiors expo 2008

Laird Engineered Thermal Systems Application Note. Thermoelectric Modules and Assemblies for Medical Laser Cooling Applications

Optimizing Airflow on Dust, Mist and Fume Collection Systems

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

TABLE OF CONTENTS. 1. How Efficient is a Thermoelectric Cooler? What is a Thermoelectric System Over 2 a Compressor?

Maximizing the Power Efficiency of Integrated High-Voltage Generators

5A LOW DROPOUT POSITIVE REGULATOR

Metal-Oxide Varistors (MOVs) Surface Mount Multilayer Varistors (MLVs) > MLA Automotive Series

Transcription:

A Review of DC/DC Converter De-rating Practices By: Tim Powers As a power design engineer, the most commonly asked questions are by far related to thermal performance of dc-dc converters. At issue are many factors, such as power and temperature de-rating, thermal measurement techniques, correlation of case temperature to ambient temperature, heat sink selection, required airflow, and the list goes on. Max operating case temperature is the most commonly used parameter that converter manufacturers use to rate their products. But this value does not readily relate to how a converter will operate within a system, which makes these questions difficult to answer. A converter's case temperature can vary widely under the same electrical conditions within different systems as the overall environments are seldom the same. When a converter is selected based solely on its power capability, other suitable products may be overlooked. The theory that converter reliability can be assured by simply de-rating the power used by 50% is unsound. This may be a good practice for most passive components such as resistors where using a.25 watt part at.125 watts or less is considered to be the safe operating area. But when this approach is applied to a converter, it may actually cause more stress, leading to higher cooling costs and lower MTBF. Most DC-DC manufactures have design de-rating guidelines. Design engineer also may use guidelines that they have developed themselves. In a system requiring 100 watts of power these guidelines often call for a 200-watt converter. This sounds safe and practical, right? Maybe not. As engineers, we de-rate components to improve their reliability by decreasing component stress. The key to optimizing converter selection is to understand the properties of the converter and to choose the one that exhibits the least stress within the intended application.

The author suggests using the term "usable power." Usable power is the amount of rated output power a converter can generate without requiring an unrealistic amount of cooling. As the design of a system unfolds, the available means of cooling and mounting become pre-defined. Space provided dictates whether a heat sink can be used and if so, its size. As engineers, we would like to start with the power dissipation and temperature, design the required head sink based on its thermal impedance in ºC/Watt and design the system around it. The fact is that available space ultimately dictates this decision. Most systems have fan requirements with little room for negotiation. Even with airflow, the location set aside for the converter is usually determined by electrical layout parameters, not convenience based on cooling. The converter will be subjected to the system's max ambient temperature, which is a function of where the system will be used, the power dissipated from the converter and its neighboring components, and the effort made to remove the heat. Here again, the constraints begin with the initial system parameters and the design must accommodate these constraints. With all of this imposed on the system design engineer, it is more important than ever to select the right converter. Why is de-rating a converter by 50% based on power wrong? It isn't necessarily wrong and there are cases where it will work out fine. A common mistake design engineers make is overlooking suitable converters (which very well may be better solutions) because of a misconceived design guideline. Let's look at an example where a converter was selected based on derated power. In this scenario, perfectly appropriate converter solutions were improperly rejected because the "required" power level was not specified in the desired package. There are many factors to consider when searching for a converter, but for our example we will compare thermal aspects along, as most other parameters are very similar. Under worst-case loads consider a power requirement of roughly 100 watts and a half-brick package size. The first inclination may be ti select a converter rated for 200 watts at the appropriate output voltage and input voltage range. Cost may confine our selection to a mid-level performance converter in that power range. A converter rated at 87% efficient seems sufficient for these purposes, especially since we would be using it at 1/2 load worst case or lower.

From the curve in Fig. 1 the efficiency at 100 watts (50%) is about 84% and at 70 watts the efficiency is about 80%. At very light loads, the efficiency of a converter is generally low. As the load increases, the efficiency follows to the point where it nears its nominal value. Then the increasing efficiency becomes less linear. After this knee in the curve, the efficiency will generally peak at some point and then begin to decline. The power dissipated at these points follows: 100 Watts: (100/.84)-100=19 watts dissipated 70 Watts: (70/.8)-70=17.5 watts dissipated

By placing the normal operating load point near the knee on the efficiency curve, the power dissipated increases dramatically. The converter we chose was 125 watts. The most parameters were relatively equal, but the efficiency was dramatically improved. Lowering the power requirements increased our choices allowing us to consider higher performance models. From the curve in Fig. 2 the basic shape of the curve is very similar with higher overall efficiencies. At 100 watts we have 92% efficiency, and at 70 watts we have 91.2%. Comparing the power dissipated we observe: 100 watts: (100/.92)-100=8.7 watts dissipated 70 watts: (70/.912)-70=6.75 watts dissipated The difference is more than 50% in favor of the lower power converter. As a bonus, lower power converters actually run cooler without a heat sink than the higher power units run with a heat sink! It's always difficult to discern a converter's capabilities from initial manufacturer claims. Questionable marketing practices may add to the confusion. As advertised, a converter may be capable of 200+ watts in that package, but it also may require an inordinate amount of cooling. The obvious question which results is why can't the higher performance/lower power converter be made to deliver 200 watts? The answer relates to component robustness. Larger semiconductor packages like D and D2 packages are tough and have more volume to absorb thermal transients. Smaller packages like SO8 are less capable of withstanding sudden thermal transients and don't always offer sufficient means of transferring the heat. FET's in these small packages offers smaller die's with less parasitic capacitance's and lower RDS ON ratings. Though this reduces losses, there are practical limits to their capabilities.

Conclusion Though de-rating values are useful indications of a converter's performance, design engineers must exercise caution when relying on these values to select the proper dc-dc converter. By carefully considering the combination of parameters that contribute to an understanding of the complete thermal picture, the design engineer can confidently select the most suitable candidates for their design. How can we help you? To speak with our power supply and conversion specialists, contact us any time at 888-597-9255 or sales@wallindustries.com. We can t wait to power your success.