Power Factor Correction Capacitors Type LKT

Similar documents
Power Factor Correction Capacitors Type LKT

Power Factor Correction Capacitors Type LKT

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:

Power Factor Correction

High Reliable Components for Power Factor Correction and Power Quality

Power Factor Correction Capacitors Type LKT

High Reliable Components for Power Factor Correction and Power Quality

POWER CAPACITORS. Cylindrical capacitor standard duty

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

Power Factor Correction Capacitors in sheet steel cases

PhiCap Capacitors for Power Factor Correction

multicond Power capacitors Data sheet: multicond

LV Capacitors QCap-L series Capacitors for power factor correction

PhaseCap HD Capacitors for Power Factor Correction

Three Phase Capacitors KNK

Advancements in AC Power Capacitor Manufacturing Techniques Solve Traditional Industry Application Problems

LV Capacitor CLMD Reliability for Power Factor Correction

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction

EMPAC Metal enclosed capacitor bank for wind applications

Power Factor Correction

Medium Voltage Capacitors

PoleCap Capacitors for Power Factor Correction (Outdoor usage)

Power Factor Correction Capacitors Harmonic Filter Reactors

Automatic COSYS PFC. Automatic power factor correction system NEW

LV Capacitor Bank APC

PhaseCap capacitors for power factor correction

- Soft resin impregnated Stacked winding Tripple Safety System

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

Film capacitors Power Factor Correction

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

MODVAR Low voltage reactive power compensation modules Installation manual

Trifazni kondenzatorji KNK

Easy Choice for Energy Efficiency

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions

LV Capacitor Bank APC

Power Factor Correction

LV Capacitor CLMD03 Power Module Instruction manual

Film Capacitors Power Factor Correction

Components for Power Factor Correction

CLMD Low-voltage capacitors for reliable power factor correction

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

Low Voltage Power Factor Corrections

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

Film capacitors Power Factor Correction

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Capacitor Switching Contactors Type K3...-A, K3...-K

Film Capacitors Power Factor Correction

CP Automatic capacitor bank

Aerovox Corp. Capacitors for HID Lighting Applications. Catalog HID-cap 2004-R0

Product details are described at websites

Film Capacitors Power Factor Correction

Power Quality Solutions

Capacitors for Power Factor Correction

DYNACOMP. The top-class reactive power compensator

Motor Running & Motor Starting Lamp Power Factor

Film Capacitors Power Factor Correction

Medium Power Film Capacitors

MADE IN GERMANY. Components for reactive power compensation. Components for reactive power compensation. Power Quality. Reactive power controllers

Film Capacitors Power Factor Correction

Index Low Voltage Network Quality. Low Voltage Network Quality

Energy sector DC LINK CAPACITORS AND SNUBBERS

Film capacitors Power Factor Correction

APC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction

Power System Solutions (PSS)

Power Factor Correction Equipment

Technical Specification For Outdoor Substation Harmonic Filter Banks

Power factor correction Harmonic filtering Dynamic flicker compensation

Film Capacitors Power Factor Correction

Power factor correction and harmonic filtering. Power capacitors Low Voltage

Applications C87 8 B F AA 4 J

FRANKE. Power Factor Correction GMKP ENERGY. GMKPg Low Voltage Capacitors by Gas Technology Save energy and reduce carbon dioxide emission!

C1000 Series Automatic Cap Bank

Tubular capacitor. Electrical features Overcurrent 1,8 times the rated current (permanently)

ARTECHE LOW VOLTAGE CAPACITOR BANKS. smartbat LV.

Film Capacitors Power Factor Correction

Product Groups. Standard Features

Power capacitors Low Voltage

POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR

Power Factor Correction

Applications. Internal Connection

Ensuring the Safety Of Medical Electronics

Dimensions mm. IMax Multiplier 1kHz 10kHz. Ambient Temperature. Fixing symbol code

Motor Run & General Purpose AC Capacitors. AC Film Capacitors for. Purpose Applications. RoHS COMPLIANT. Intelligent Capacitor Solutions

B. Coefficient table for calculation of capacitance after rated voltage increase

Reactive Energy Management

Snubber, High Current DC, and Switching Capacitors

Power Factor Correction - UPS - Stabilizers - AC / DC Power Supply Units

A-C Capacitors for Motor Run Applications

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

Q pole Pole Mounted Capacitor System

POWER FACTOR CORRECTION Three phase Power Factor Correction Capacitors, Accessories and Trays

POWER ELECTRONIC CAPACITORS

Thermal Overload Relays - WEG RW Series, 2 Pole

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

100V 160V 200V 250V 400V

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

Transcription:

Power Factor Correction s LKT E337088 Features that matter: Handles continuous current up to 2.25 / 2.7 times rated current Withstands inrush current up to 375 / 450 times rated current Self-healing type, segmented film techno ogy plus overpressure disconnector Environment-friendly, dry type CO 2 emission reduction Saves energy costs It s all about saving your money!

Power Factor Correction s LKT General Features FRAKO Power Factor Correction s utilize unique advanced technology and incorporate our exclusive triple safety feature. FRAKO is the first power capacitor manufacturer to succeed in combining segmented capacitor film with self-healing and over-pressure disconnection. This exclusive manufacturing technique significantly increases the reliability of capacitors in power factor and filter applications The capacitors are compliant with: UL 810 (up to 600 VAC, 68 C ambient) CSA C22.2 190 (up to 600 VAC, 46 C ambient) IEC 60831 (up to 800 VAC, 68 C ambient) Technical Features For the operation of Power Factor Correction s three aspects are of utmost importance: High current capability Long life expectancy Triple safety features High Current Capability In electrical systems containing harmonic producing loads, power factor capacitors must be capable of carrying additional current due to the system harmonics. Even without resonance, harmonics will increase capacitor terminal voltage and increase capacitor current, which can further stress a capacitor making it necessary for a high current capability. If, for example, the 11th harmonic is present with 8% of the rated system voltage, then the rms value of the rated voltage is only slightly increased (about 0.3%), but the current in the capacitor will exceed its rated value by 33%. It becomes clear that the ability of a capacitor to withstand excessive current is much more important than the ability to withstand excessive voltage. Therefore FRAKO designs its capacitors as follows: Maximum continuous current up to 2.25 / 2.7 times rated current Withstand inrush current up to 375 / 450 times rated current Highest Durability FRAKO capacitors have earned a reputation for superior quality, high reliability and long life expectancy. This is assured by our conservative approach to capacitor design plus skillful manufacturing processes and in-process verification testing. FRAKO sets a new standard for capacitor manufacturing. Exceeds Industry Standards Our specifications for capacitors exceed all known industry standards and FRAKO capacitors surpass the requirements of UL, CSA and EN/IEC standards. Additional quality tests following each individual manufacturing step confirm an outstanding manufacturing quality. Through our unique manufacturing process, FRAKO achieves a world leading capacitor of the highest durability. Exclusive Manufacturing Process for long life For example, our consistently low power loss throughout the life of the capacitor, is achieved by our use of a proprietary mineral filler and stabilizer which can permanently avoid partial discharges within the dielectric material. Our vacuum drying process takes place under temperature controlled conditions for several days and eliminates the possibility of humidity within the capacitor - which if present would accelerate the aging process of a capacitor (reducing capacitor life). This process is an extra effort made by FRAKO but pays off for our customers with a longer life expectancy. Our production processes assure that quality and reliability are built into every capacitor, and this is confirmed by our verification testing current 2

Power Factor Correction s LKT Safety Features FRAKO Power Factor Correction s offer our exclusive Triple Safety feature: Self-healing at over-voltage Segmented film increase capacitor integrity and life expectancy by removing (electrically) small segments of film which have been damaged e. g. in the unlikel event of a failing self-healing process Our patented over-pressure disconnector system assures safe and quick removal of capacitors from the electrical circuit at the end of their life or under a severe overload condition Over-Voltage Capability FRAKO Power Factor Correction s have an over-voltage capability that meets the requirements of EN 60831-1 and -2, IEC 60831-1 and -2, and surpasses the requirements of UL 810: Rated voltage [VAC] 240 300 400 440 480 500 525 600 Over-voltage [VAC] 8 hours daily 264 330 440 484 528 550 578 660 30 min. daily 276 345 460 506 552 575 604 690 5 min. daily 288 360 480 528 576 600 630 720 1 min. daily 312 390 520 572 624 650 683 780 Further ratings for IEC only: Rated voltage [VAC] 690 800 Self-healing segmented capacitor fil Over-voltage [VAC] 8 hours daily 759 880 30 min. daily 793.5 920 5 min. daily 828 960 1 min. daily 897 1040 The principle of the overpressure disconnector Patent 102005045978 To verify proper functioning of all internal safety systems, FRAKO regularly draws sample capacitors from the production line and performs multiple tests to confir proper operation of the safety system and to assure our outstanding quality is achieved in every capacitor. Application FRAKO capacitors are recommended for use in fixe or automatic power factor correction systems as well as harmonic filters. FRAKO holds system registration certificates for ISO 9001 (quality system), ISO 14001 (environmental management system) and ISO 50001 (energy management system). Mechanical Construction Cylindrical aluminum case with mounting stud M12 12, low loss self-healing dielectric made from segmented metallized polypropylene film. Filled with a dry type PCBfree, flame inhibiting, mineral filler with adhesive stabilizer and integrated mechanical overpressure disconnector. Discharge resistors are permanently connected at the capacitor terminals. Our patented fast connecting terminal, available as an option, minimizes wiring time, protects against direct contact with live terminals and meets the requirements of protection class IP20. 3

Power Factor Correction s LKT Design FRAKO specializes in the production of three phase capacitors which are available in a wide variety of ratings to meet various international requirements. Our additional offerings include single phase capacitors and medium voltage capacitors. Please contact our company for more information. Ratings UL/CSA: IEC: 0.9-30 kvar ; 208-600 VAC 0.9-30.9 kvar ; 208-800 VAC UL/CSA: 0.7-25 kvar ; 208-600 VAC IEC: 0.7-25.7 kvar ; 208-800 VAC Other ratings upon request. Maximum Fault Current: 10,000 amps Capacitance Tolerance - 5% / + 5% (Available to - 1% / + 1%) Discharging after Disconnection In accordance with the National Electrical Code (NFPA 70, Article 460), Canadian Electrical Code (C22.2 190- M1985) and IEC 60831, all FRAKO capacitors have integrated discharge resistors that guarantee terminal voltage will discharge to 50 V or less within one minute after the capacitor is disconnected from the power source. Accessories: Fast Connecting Terminal for FRAKO Power Factor Correction s All FRAKO capacitors are available with an optional fast connecting terminal. This maintenance free, patented terminal saves wiring time and assures secure connection of capacitor wiring and maintains permanent connection for the duration of the capacitor life. Article- Description 31-08005 Plug-in type fast connecting terminal for capacitors with 85 mm, 3-phase 31-08004 Plug-in type fast connecting terminal for capacitors with 85 mm, single phase AKD 30/3 AKD 30/1 Power Loss Less than 0.5 W / kvar when measured at the connecting terminal (including discharge resistor). About 0.2 W/ kvar dielectric losses. Ambient Temperature UL/IEC: - 40 C up to + 68 C (- 40 F up to + 154 F) CSA: - 40 C up to + 46 C (- 40 F up to + 114.8 F) Plug-in type fast connecting terminal for capacitors with 85 mm : AKD 30/3 Article-: 31-08005 4

Power Factor Correction s LKT Dimensions 16 h 17.0 16 h 35.0 M12 M12 s with d = 85 mm (3.35 in) diameter for connection with flat cable plu 9.5 1.2 mm (0.38 0.05 in) s with d = 85 mm (3.35 in) diameter Fast connecting terminal AKD 30/3 6 AWG 16 mm 2 (0.0248 in 2 ) Height (h) varies by capacitor rating (see page 8-15 for h dimensions) 5

Technical Data Technical Data Basic Standard Premium Heavy Duty operated with DL-specificatio operated with DP-specification* LKT -DB60 LKT -DP60 LKT -DL60 LKT -DL60 LKT -HD60 Rated reactive power 1.8 30 kvar 1.5 25 kvar 0.9 30 kvar 0.7 25 kvar 1.8 25 kvar 1.5 20.8 kvar 1.8 29.9 kvar 2) 1.5 24.9 kvar 2) 3.2 21.6 kvar 2.7 18 kvar Rated voltage 208 525 V UL ratings: 208 600 V 208 525 V UL ratings: 208 600 V 208 525 V IEC ratings: 208 800 V IEC ratings: 208 615 V Rated frequency Maximum overcurrent capability (at rated voltage) Maximum inrush current capability (at rated voltage) Ambient temperature 1) Maximum case temperature Dielectric power loss Power loss including discharge resistors Test voltage (terminal - terminal) Test voltage (terminal - case) Mean life expectancy Maximum humidity 60 / 50 Hz power frequency suitable for use in harmonic and PWM voltage filter 1.25 l N 1.5 l N 167 l N 200 l N -25 ºC up to class D (-13 ºF up to class D) 60 / 50 Hz power frequency suitable for use in harmonic and PWM voltage filter 1.5 l N 1.8 l N 208 l N 250 l N -40 ºC up to +60 ºC (-40 ºF up to +140 ºF) 60 / 50 Hz power frequency suitable for use in harmonic and PWM voltage filter 1.8 l N 2.2 l N 250 l N 300 l N -40 ºC up to +65 ºC (-40 ºF up to +149 ºF) 60 / 50 Hz power frequency suitable for use in harmonic and PWM voltage filters 1.65 l N 2.0 l N 250 l N 300 l N -40 ºC up to +60 ºC (-40 ºF up to +140 ºF) 60 / 50 Hz power frequency suitable for use in harmonic and PWM voltage filter 2.25 l N 2.7 l N 375 l N 450 l N -40 ºC up to +68 ºC (-40 ºF up to +154 ºF) 70 ºC (158 ºF) 75 ºC (167 ºF) 75 ºC (167 ºF) 75 ºC (167 ºF) 75 ºC (167 ºF) 0.2 W/kvar 0.2 W/kvar 0.2 W/kvar 0.2 W/kvar 0.2 W/kvar 0.5 W/kvar 0.5 W/kvar 0.5 W/kvar 0.5 W/kvar 0.5 W/kvar 2.15 U N for 2 s 1.85 U N for 18 s 2.15 U N for 2 s 1.85 U N for 18 s 2.15 U N for 2 s 1.85 U N for 18 s 2.15 U N for 2 s 1.85 U N for 18 s 2.15 U N for 2 s 1.85 U N for 18 s 3,900 V, 2 s 3,900 V, 2 s 3,900 V, 2 s 3,900 V, 2 s 3,900 V, 2 s 100,000 h. 130,000 h. 170,000 h. 130,000 h. 200,000 h. 95% relative humidity 95% relative humidity 95% relative humidity 95% relative humidity 95% relative humidity Maximum altitude 4,000 m (13,124 ft) 4,000 m (13,124 ft) 4,000 m (13,124 ft) 4,000 m (13,124 ft) 4,000 m (13,124 ft) Number of 20,000 40,000 60,000 60,000 100,000 annual switching operations Discharging level in 60 s 50 V 50 V 50 V 50 V 50 V 1) CSA compliance up to +46 ºC (114.8 ºF) maximum Generally, DL-type capacitors can also be operated at higher voltages with the DP-type specification Please note that the DP values in the chart are marked with * 2) IEC ratings up to 30.9 kvar / 25.7 kvar 6

Technical Data Basic Standard Premium Heavy Duty Tightening torque for aluminium mounting screw (approx.) Recommended for 15 Nm (133 in-lbs) 15 Nm (133 in-lbs) 15 Nm (133 in-lbs) 15 Nm (133 in-lbs) 15 Nm (133 in-lbs) Networks with low harmonic content and normal ambient temperature Networks with higher harmonic levels and/ or high ambient temperature Demanding networks (i.e. networks with very high harmonic levels and/or very high ambient temperature) 1) CSA compliance up to +46 ºC (114.8 ºF) maximum Generally, DL-type capacitors can also be operated at higher voltages with the DP-type specification Please note that the DP values in the chart are marked with * 2) IEC ratings up to 30.9 kvar / 25.7 kvar Networks with higher harmonic levels and/ or high ambient temperature Extreme demanding network- and ambient conditions Temperature class admissible ambient temperature maximum mean over 24 h highest mean over 1 year D 55ºC (131 ºF) 45ºC (113 ºF) 35ºC (95 ºF) 7

Power Factor Correction s (three-phase) LKT -DP60 for 60 Hz Standard s (three-phase) Diam. Capacitance Article- Rated Reactive Power in kvar at Rated Voltage 60Hz 208 V 230 V 240 V 300 V 400 V 415 V 440 V 460 V 480 V 525 V 570 V 600 V 10-240-DP60 85 163 3 153.5 31-10629 7.5 9.2 10.0 12.5-240-DP60 85 215 3 191.9 31-10630 9.4 11.5 12.5 20-240-DP60 85 278 3 307.0 31-10631 15.0 18.4 20.0 15-300-DP60 85 163 3 147.4 31-10632 7.2 8.8 9.6 15.0 18-300-DP60 85 215 3 176.8 31-10633 8.7 10.6 11.5 18.0 12-400-DP60 85 163 3 66.3 31-10652 3.2 4.0 4.3 6.8 12.0 15-400-DP60 85 215 3 82.9 31-10653 4.1 5.0 5.4 8.4 15.0 24-400-DP60 85 278 3 132.6 31-10654 6.5 7.9 8.6 13.5 24.0 30-400-DP60 85 278 3 165.8 31-10655 8.1 9.9 10.8 16.9 30.0 12-440-DP60 85 163 3 54.8 31-10656 2.7 3.3 3.6 5.6 9.9 10.7 12.0 15-440-DP60 85 215 3 68.5 31-10657 3.4 4.1 4.5 7.0 12.4 13.3 15.0 24-440-DP60 85 278 3 109.6 31-10658 5.4 6.6 7.1 11.2 19.8 21.4 24.0 30-440-DP60 85 278 3 137.0 31-10659 6.7 8.2 8.9 13.9 24.8 26.7 30.0 10-480-DP60 85 163 3 38.4 31-10634 1.9 2.3 2.5 3.9 6.9 7.5 8.4 9.2 10.0 12.5-480-DP60 85 163 3 48 31-10635 2.3 2.9 3.1 4.9 8.7 9.3 10.5 11.5 12.5 20-480-DP60 85 215 3 76.8 31-10636 3.8 4.6 5.0 7.8 13.9 15.0 16.8 18.4 20.0 25-480-DP60 85 278 3 95.9 31-10637 4.7 5.7 6.3 9.8 17.4 18.7 21.0 23.0 25.0 11.25-525-DP60 85 163 3 36.1 31-10638 1.8 2.2 2.4 3.7 6.5 7.0 7.9 8.6 9.4 11.25 14-525-DP60 85 215 3 44.9 31-10639 2.2 2.7 2.9 4.6 8.1 8.8 9.8 10.7 11.7 14.0 22.5-525-DP60 85 278 3 72.2 31-10640 3.5 4.3 4.7 7.3 13.1 14.1 15.8 17.3 18.8 22.5 28-525-DP60 85 278 3 89.8 31-10641 4.4 5.4 5.9 9.1 16.3 17.5 19.7 21.5 23.4 28.0 10-600-DP60 85 215 3 24.6 31-10642 1.2 1.5 1.6 2.5 4.4 4.8 5.4 5.9 6.4 7.7 9.0 10.0 12.5-600-DP60 85 215 3 30.7 31-10643 1.5 1.8 2.0 3.1 5.6 6.0 6.7 7.3 8.0 9.6 11.3 12.5 20-600-DP60 85 278 3 49.1 31-10644 2.4 2.9 3.2 5.0 8.9 9.6 10.8 11.8 12.8 15.3 18.1 20.0 25-600-DP60 85 320 3 61.4 31-10645 3.0 3.7 4.0 6.3 11.1 12.0 13.4 14.7 16.0 19.1 22.6 25.0 12.5-690-DP60 85 215 3 23.2 31-10646 1.1 1.4 1.5 2.4 4.2 4.5 5.1 5.6 6.0 7.2 8.5 9.5 15-690-DP60 85 215 3 27.9 31-10647 1.4 1.7 1.8 2.8 5.0 5.4 6.1 6.7 7.3 8.7 10.2 11.3 20-690-DP60 85 215 3 37.1 31-10648 1.8 2.2 2.4 3.8 6.7 7.2 8.1 8.9 9.7 11.6 13.7 15.1 25-690-DP60 85 278 3 46.4 31-10649 2.3 2.8 3.0 4.7 8.4 9.0 10.2 11.1 12.1 14.5 17.1 18.9 30-690-DP60 85 320 3 55.7 31-10650 2.7 3.3 3.6 5.7 10.1 10.9 12.2 13.3 14.5 17.4 20.5 22.7 12.6-800-DP60 85 215 3 17.4 31-10661 0.9 1.0 1.1 1.8 3.2 3.4 3.8 4.2 4.5 5.4 6.4 7.1 16-800-DP60 85 215 3 22.1 31-10662 1.1 1.3 1.4 2.3 4.0 4.3 4.8 5.3 5.8 6.9 8.1 9.0 25.2-800-DP60 85 278 3 34.8 31-10663 1.7 2.1 2.3 3.5 6.3 6.8 7.6 8.3 9.1 10.9 12.8 14.2 10

Power Factor Correction s (three-phase) LKT -DP60 for 50 Hz Standard s (three-phase) Diam. Capacitance Article- Rated Reactive Power in kvar at Rated Voltage 50Hz 208 V 230 V 240 V 300 V 400 V 415 V 440 V 460 V 480 V 525 V 570 V 600 V 10-240-DP60 85 163 3 153.5 31-10629 6.3 7.7 8.33 12.5-240-DP60 85 215 3 191.9 31-10630 7.8 9.6 10.4 20-240-DP60 85 278 3 307.0 31-10631 12.5 15.3 16.7 15-300-DP60 85 163 3 147.4 31-10632 6.0 7.4 8.0 12.5 18-300-DP60 85 215 3 176.8 31-10633 7.2 8.8 9.6 15.0 12-400-DP60 85 163 3 66.3 31-10652 2.7 3.3 3.6 5.6 10.0 15-400-DP60 85 215 3 82.9 31-10653 3.4 4.1 4.5 7.0 12.5 24-400-DP60 85 278 3 132.6 31-10654 5.4 6.6 7.2 11.3 20.0 30-400-DP60 85 278 3 165.8 31-10655 6.8 8.3 9.0 14.1 25.0 12-440-DP60 85 163 3 54.8 31-10656 2.2 2.7 3.0 4.6 8.3 8.9 10.0 15-440-DP60 85 215 3 68.5 31-10657 2.8 3.4 3.7 5.8 10.3 11.1 12.5 24-440-DP60 85 278 3 109.6 31-10658 4.5 5.5 6.0 9.3 16.5 17.8 20.0 30-440-DP60 85 278 3 137.0 31-10659 5.6 6.8 7.4 11.6 20.7 22.2 25.0 10-480-DP60 85 163 3 38.4 31-10634 1.6 1.9 2.1 3.2 5.8 6.2 7.0 7.7 8.3 12.5-480-DP60 85 163 3 48 31-10635 2.0 2.4 2.6 4.1 7.2 7.8 8.8 9.6 10.4 20-480-DP60 85 215 3 76.8 31-10636 3.1 3.8 4.2 6.5 11.6 12.5 14.0 15.3 16.7 25-480-DP60 85 278 3 95.9 31-10637 3.9 4.8 5.2 8.1 14.5 15.6 17.5 19.1 20.8 11.25-525-DP60 85 163 3 36.1 31-10638 1.5 1.8 2.0 3.1 5.4 5.9 6.6 7.2 7.8 9.4 14-525-DP60 85 215 3 44.9 31-10639 1.8 2.2 2.4 3.8 6.8 7.3 8.2 9.0 9.8 11.7 22.5-525-DP60 85 278 3 72.2 31-10640 3.0 3.6 3.9 6.1 10.9 11.7 13.2 14.4 15.7 18.8 28-525-DP60 85 278 3 89.8 31-10641 3.7 4.5 4.9 7.6 13.5 14.6 16.4 17.9 19.5 23.3 10-600-DP60 85 215 3 24.6 31-10642 1.0 1.2 1.3 2.1 3.7 4.0 4.5 4.9 5.3 6.4 7.5 8.3 12.5-600-DP60 85 215 3 30.7 31-10643 1.2 1.5 1.7 2.6 4.6 5.0 5.6 6.1 6.7 8.0 9.4 10.4 20-600-DP60 85 278 3 49.1 31-10644 2.0 2.5 2.7 4.2 7.4 8.0 9.0 9.8 10.7 12.8 15.0 16.7 25-600-DP60 85 320 3 61.4 31-10645 2.5 3.1 3.3 5.2 9.2 10.0 11.2 12.2 13.3 16.0 18.8 20.8 12.5-690-DP60 85 215 3 23.2 31-10646 0.9 1.2 1.3 2.0 3.5 3.8 4.2 4.6 5.0 6.0 7.1 7.9 15-690-DP60 85 215 3 27.9 31-10647 1.1 1.4 1.5 2.4 4.2 4.5 5.1 5.6 6.0 7.2 8.5 9.5 20-690-DP60 85 215 3 37.1 31-10648 1.5 1.9 2.0 3.2 5.6 6.0 6.8 7.4 8.1 9.7 11.4 12.6 25-690-DP60 85 278 3 46.4 31-10649 1.9 2.3 2.5 3.9 7.0 7.5 8.5 9.2 10.1 12.1 14.2 15.8 30-690-DP60 85 320 3 55.7 31-10650 2.3 2.8 3.0 4.7 8.4 9.0 10.2 11.1 12.1 14.5 17.1 18.9 12.6-800-DP60 85 215 3 17.4 31-10661 0.7 0.9 0.9 1.5 2.6 2.8 3.2 3.5 3.8 4.5 5.3 5.9 16-800-DP60 85 215 3 22.1 31-10662 0.9 1.1 1.2 1.9 3.3 3.6 4.0 4.4 4.8 5.7 6.8 7.5 25.2-800-DP60 85 278 3 34.8 31-10663 1.4 1.7 1.9 3.0 5.3 5.7 6.4 6.9 7.6 9.0 10.7 11.8 11

Power Factor Correction s (three-phase) LKT -DP60 for 60 Hz and 50 Hz Standard s (three-phase) - IEC ratings only Diam. Capacitance Article- Rated Reactive Power in kvar at Rated Voltage 60Hz 208 V 600 V 615 V 690 V 750 V 800 V 12.5-690-DP60 85 215 3 23.2 31-10646 9.9 12.5 See Table 15-690-DP60 85 215 3 27.9 31-10647 11.9 15.0 Standard s (three-phase) 20-690-DP60 85 215 3 37.1 31-10648 15.9 20.0 - UL ratings 25-690-DP60 85 278 3 46.4 31-10649 19.9 25.0 30-690-DP60 85 320 3 55.7 31-10650 23.8 30.0 12.6-800-DP60 85 215 3 17.4 31-10661 7.5 9.4 11.1 12.6 16-800-DP60 85 215 3 22.1 31-10662 9.5 11.9 14.1 16.0 25.2-800-DP60 85 278 3 34.8 31-10663 14.9 18.8 22.2 25.2 Standard s (three-phase) - IEC ratings only Diam. Capacitance Article- Rated Reactive Power in kvar at Rated Voltage 50Hz 208 V 600 V 615 V 690 V 750 V 800 V 12.5-690-DP60 85 215 3 23.2 31-10646 8.3 10.4 See Table 15-690-DP60 85 215 3 27.9 31-10647 9.9 12.5 Standard s (three-phase) 20-690-DP60 85 215 3 37.1 31-10648 13.2 16.7 - UL ratings 25-690-DP60 85 278 3 46.4 31-10649 16.6 20.8 30-690-DP60 85 320 3 55.7 31-10650 19.9 25.0 12.6-800-DP60 85 215 3 17.4 31-10661 6.2 7.8 9.2 10.5 16-800-DP60 85 215 3 22.1 31-10662 7.9 9.9 11.7 13.3 25.2-800-DP60 85 278 3 34.8 31-10663 12.4 15.6 18.5 21.0 12

Power Factor Correction s (single-phase) LKT -EP for 60 Hz and 50 Hz Standard s (single-phase) - IEC ratings only Diam. Capacitance Article- Rated Reactive Power in kvar at Rated Voltage 60Hz 208 V 230 V 280 V 400 V 415 V 440 V 460 V 480 V 525 V 5-280-EP 60 138 1 203.7 31-10547 3.3 4.1 6.0 10-280-EP 85 131 1 407.4 31-10548 6.6 8.1 12.0 3.33-440-EP 60 90 1 54.8 31-10526 0.9 1.1 1.6 3.3 3.6 4.0 4.17-440-EP 60 138 1 68.6 31-10527 1.1 1.4 2.0 4.1 4.5 5.0 5-440-EP 60 138 1 82.2 31-10528 1.3 1.6 2.4 5.0 5.33 6.0 9.4-440-EP 70 138 1 154.6 31-10511 2.5 3.1 4.6 9.3 10.0 11.3 2.4-480-EP 60 90 1 33.2 31-10529 0.5 0.7 1.0 2.0 2.15 2.4 2.7 2.9 3.33-480-EP 60 90 1 46.0 31-10530 0.8 0.9 1.4 2.8 3.0 3.4 3.7 4.0 3.6-480-EP 60 138 1 49.7 31-10531 0.8 1.0 1.5 3.0 3.2 3.6 3.9 4.3 4.8-480-EP 60 138 1 66.3 31-10515 1.1 1.3 2.0 4.0 4.3 4.8 5.3 5.8 6-480-EP 60 138 1 82.9 31-10514 1.4 1.66 2.5 5.0 5.4 6.0 6.6 7.2 2.8-525-EP 60 90 1 32.3 31-10532 0.5 0.7 1.0 1.9 2.1 2.4 2.6 2.8 3.4 3.33-525-EP 60 138 1 38.5 31-10533 0.6 0.8 1.1 2.3 2.5 2.8 3.1 3.3 4.0 8.33-525-EP 70 138 1 96.2 31-10518 1.6 1.9 2.8 5.8 6.3 7.0 7.7 8.33 10.0 Standard s (single-phase) - IEC ratings only Diam. Capacitance Article- Rated Reactive Power in kvar at Rated Voltage 50Hz 208 V 230 V 280 V 400 V 415 V 440 V 460 V 480 V 525 V 5-280-EP 60 138 1 203.7 31-10547 2.8 3.4 5.0 10-280-EP 85 131 1 407.4 31-10548 5.5 6.8 10.0 3.33-440-EP 60 90 1 54.8 31-10526 0.7 0.9 1.3 2.8 3.0 3.33 4.17-440-EP 60 138 1 68.6 31-10527 0.9 1.1 1.7 3.4 3.7 4.17 5-440-EP 60 138 1 82.2 31-10528 1.1 1.4 2.0 4.1 4.4 5.0 9.4-440-EP 70 138 1 154.6 31-10511 2.1 2.6 3.8 7.8 8.4 9.4 2.4-480-EP 60 90 1 33.2 31-10529 0.5 0.6 0.8 1.70 1.80 2.0 2.2 2.4 3.33-480-EP 60 90 1 46.0 31-10530 0.6 0.8 1.1 2.3 2.5 2.8 3.1 3.33 3.6-480-EP 60 138 1 49.7 31-10531 0.7 0.8 1.2 2.5 2.7 3.0 3.3 3.6 4.8-480-EP 60 138 1 66.3 31-10515 0.9 1.1 1.6 3.33 3.6 4.0 4.4 4.8 6-480-EP 60 138 1 82.9 31-10514 1.1 1.4 2.0 4.17 4.5 5.0 5.5 6.0 2.8-525-EP 60 90 1 32.3 31-10532 0.4 0.5 0.8 1.6 1.7 2.0 2.1 2.3 2.8 3.33-525-EP 60 138 1 38.5 31-10533 0.5 0.6 0.9 1.9 2.1 2.3 2.6 2.8 3.33 8.33-525-EP 70 138 1 96.2 31-10518 1.3 1.6 2.4 4.8 5.2 5.9 6.4 7.0 8.33 13

Power Factor Correction s (three-phase) LKT -DL60 for 60 Hz and 50 Hz Premium s (three-phase) 3) Diam. Capacitance Article- Rated Reactive Power in kvar at Rated Voltage 60Hz 208 V 230 V 240 V 300 V 400 V 415 V 440 V 460 V 480 V 525 V 570 V 600 V 615 V 12-400-DL60 85 215 3 66.3 31-10680 3.2 4.0 4.3 6.8 12.0 12.9* 14.5* 15-400-DL60 85 215 3 82.9 31-10681 4.1 5.0 5.4 8.4 15.0 16.2* 18.2* 24-400-DL60 85 215 3 132.6 31-10682 6.5 7.9 8.6 13.5 24.0 25.8* 29.0* 12-440-DL60 85 163 3 54.8 31-10683 2.7 3.3 3.6 5.6 9.9 10.7 12.0 13.1* 14.3* 15-440-DL60 85 215 3 68.5 31-10684 3.4 4.1 4.5 7.0 12.4 13.3 15.0 16.4* 17.9* 24-440-DL60 85 278 3 109.6 31-10685 5.4 6.6 7.1 11.2 19.8 21.4 24.0 26.2* 28.6* 10-480-DL60 85 163 3 38.4 31-10686 1.9 2.3 2.5 3.9 6.9 7.5 8.4 9.2 10.0 12.0* 12.5-480-DL60 85 215 3 48.0 31-10687 2.3 2.9 3.1 4.9 8.7 9.3 10.5 11.5 12.5 15.0* 20-480-DL60 85 278 3 76.8 31-10688 3.8 4.6 5.0 7.8 13.9 15.0 16.8 18.4 20.0 23.9* 25-480-DL60 85 278 3 95.9 31-10689 4.7 5.7 6.3 9.8 17.4 18.7 21.0 23.0 25.0 29.9* 11.25-525-DL60 85 215 3 36.1 31-10690 1.8 2.2 2.4 3.7 6.5 7.0 7.9 8.6 9.4 11.25 13.3* 14.7 15.4* 14-525-DL60 85 215 3 44.9 31-10691 2.2 2.7 2.9 4.6 8.1 8.7 9.8 10.8 11.7 14.0 16.5* 18.3 19.2* 22.5-525-DL60 85 320 3 72.2 31-10692 3.5 4.3 4.7 7.3 13.1 14.1 15.8 17.3 18.8 22.5 26.5* 29.4 30.9* 3) UL and IEC ratings up to 600 V; 615 V IEC only Generally, DL-type capacitors can also be operated at higher voltages with the DP-type specification. Please note that the D values in the chart are marked with * Premium s (three-phase) 3) Diam. Capacitance Article- Rated Reactive Power in kvar at Rated Voltage 50Hz 208 V 230 V 240 V 300 V 400 V 415 V 440 V 460 V 480 V 525 V 570 V 600 V 615 V 12-400-DL60 85 215 3 66.3 31-10680 2.7 3.3 3.6 5.6 10.0 10.8* 12.1* 15-400-DL60 85 215 3 82.9 31-10681 3.4 4.1 4.5 7.0 12.5 13.5* 15.1* 24-400-DL60 85 215 3 132.6 31-10682 5.4 6.6 7.2 11.3 20.0 21.5* 24.2* 12-440-DL60 85 163 3 54.8 31-10683 2.2 2.7 3.0 4.6 8.3 8.9 10.0 10.9* 11.9* 15-440-DL60 85 215 3 68.5 31-10684 2.8 3.4 3.7 5.8 10.3 11.1 12.5 13.7* 14.9* 24-440-DL60 85 278 3 109.6 31-10685 4.5 5.5 6.0 9.3 16.5 17.8 20.0 21.9* 23.8* 10-480-DL60 85 163 3 38.4 31-10686 1.6 1.9 2.1 3.2 5.8 6.2 7.0 7.7 8.3 10.0* 12.5-480-DL60 85 215 3 48.0 31-10687 2.0 2.4 2.6 4.1 7.2 7.8 8.8 9.6 10.4 12.5* 20-480-DL60 85 278 3 76.8 31-10688 3.1 3.8 4.2 6.5 11.6 12.5 14.0 15.3 16.7 19.9* 25-480-DL60 85 278 3 95.9 31-10689 3.9 4.8 5.2 8.1 14.5 15.6 17.5 19.1 20.8 24.9* 11.25-525-DL60 85 215 3 36.1 31-10690 1.5 1.8 2.0 3.1 5.5 5.9 6.6 7.2 7.8 9.4 11.1* 12.3 12.9* 14-525-DL60 85 215 3 44.9 31-10691 1.8 2.2 2.4 3.8 6.8 7.3 8.2 9.0 9.8 11.7 13.8* 15.3 16.0* 22.5-525-DL60 85 320 3 72.2 31-10692 3.0 3.6 3.9 6.1 10.9 11.7 13.2 14.4 15.7 18.8 22.1* 24.6 25.7* 3) UL and IEC ratings up to 600 V; 615 V IEC only Generally, DL-type capacitors can also be operated at higher voltages with the DP-type specification. Please note that the D values in the chart are marked with * 14

Power Factor Correction s (three-phase) LKT -HD60 for 60 Hz and 50 Hz Heavy Duty s (three-phase) Diam. Capacitance Article- Rated Reactive Power in kvar at Rated Voltage 60Hz 208 V 230 V 240 V 300 V 400 V 415 V 440 V 460 V 480 V 500 V 525 V 20.1-480-HD60 85 215 3 77.1 31-10693 3.8 4.6 5.0 7.9 14.0 15.0 16.9 18.5 20.1 21.6-480-HD60 85 215 3 82.9 31-10694 4.1 5.0 5.4 8.4 15.0 16.2 18.2 19.8 21.6 18.7-500-HD60 85 215 3 66.1 31-10695 3.2 4.0 4.3 6.7 12.0 12.9 14.5 15.8 17.2 18.7 19.3-500-HD60 85 215 3 68.3 31-10696 3.3 4.1 4.4 6.9 12.4 13.3 15.0 16.3 17.8 19.3 20.2-500-HD60 85 215 3 71.4 31-10697 3.5 4.3 4.7 7.3 12.9 13.9 15.6 17.1 18.6 20.2 21.6-525-HD60 85 215 3 69.3 31-10698 3.4 4.1 4.5 7.1 12.5 13.5 15.2 16.6 18.1 19.6 21.6 Heavy Duty s (three-phase) Diam. Capacitance Article- Rated Reactive Power in kvar at Rated Voltage 50Hz 208 V 230 V 240 V 300 V 400 V 415 V 440 V 460 V 480 V 500 V 525 V 20.1-480-HD60 85 215 3 77.1 31-10693 3.2 3.9 4.2 6.6 11.6 12.5 14.1 15.4 16.8 21.6-480-HD60 85 215 3 82.9 31-10694 3.4 4.1 4.5 7.0 12.5 13.5 15.1 16.5 18.0 18.7-500-HD60 85 215 3 66.1 31-10695 2.7 3.3 3.6 5.6 10.0 10.7 12.1 13.2 14.4 15.6 19.3-500-HD60 85 215 3 68.3 31-10696 2.8 3.4 3.7 5.8 10.3 11.1 12.5 13.6 14.8 16.1 20.2-500-HD60 85 215 3 71.4 31-10697 2.9 3.6 3.9 6.0 10.7 11.6 13.0 14.3 15.5 16.8 21.6-525-HD60 85 215 3 69.3 31-10698 2.8 3.5 3.8 5.9 10.5 11.3 12.6 13.8 15.1 16.3 18.0 15

Supplemental Ratings for DP60 s kvar at 208V - 60Hz kvar at 240V - 60Hz kvar at 380V - 60Hz kvar at 440V - 60Hz kvar at 480V - 60Hz kvar at 600V - 60Hz Rated Voltage Rated KVAR uf uf wye equivalent per phase Max. Amps Article (continuous) No with 7% Reactor reactor No with 7% Reactor reactor No with 7% Reactor reactor No with 7% Reactor reactor No with 7% Reactor reactor No with 7% Reactor reactor 240 300 400 440 480 525 600 690 800 1 3x 15.4 46.2 LKT 1-240-DP60 3.6 31-10800 0.75 0.81 1.00 1.5 3x 23.0 69.0 LKT 1.5-240-DP60 5.4 31-10801 1.13 1.21 1.50 2 3x 30.7 92.1 LKT 2-240-DP60 7.2 31-10802 1.50 1.61 2.00 2.5 3x 38.4 115.2 LKT 2.5-240-DP60 9 31-10803 1.88 2.02 2.50 3 3x 46.1 138.3 LKT 3-240-DP60 10.8 31-10804 2.25 2.42 3.00 4 3x 61.4 184.2 LKT 4-240-DP60 14.4 31-10805 3.00 3.23 4.00 5 3x 76.8 230.4 LKT 5-240-DP60 18 31-10806 3.76 4.04 5.00 6 3x 92.1 276.3 LKT 6-240-DP60 21.7 31-10807 4.51 4.84 6.00 7.5 3x 115.1 345.3 LKT 7.5-240-DP60 27.1 31-10808 5.63 6.06 7.50 10 3x 153.5 460.5 LKT 10-240-DP60 36.1 31-10629 7.51 8.07 10.00 12.5 3x 191.9 575.7 LKT 12.5-240-DP60 45.1 31-10630 9.39 10.09 12.50 15 3x 230.3 690.9 LKT 15-240-DP60 54.1 31-10809 11.27 12.11 15.00 17.5 3x 268.6 805.8 LKT 17.5-240-DP60 63.2 31-10810 13.14 14.13 17.50 20 3x 307.0 921.0 LKT 20-240-DP60 72.2 31-10631 15.02 16.15 20.00 15 3x 147.4 442.2 LKT 15-300-DP60 43.3 31-10632 7.21 7.75 9.60 10.32 18 3x 176.8 530.4 LKT 18-300-DP60 52 31-10633 8.65 9.30 11.52 12.38 12 3x 66.3 198.9 LKT 12-400-DP60 26 31-10652 3.24 3.49 4.32 4.64 10.83 15 3x 82.9 248.7 LKT 15-400-DP60 32.5 31-10653 4.06 4.36 5.40 5.81 13.54 24 3x 132.6 397.8 LKT 24-400-DP60 52 31-10654 6.49 6.98 8.64 9.29 21.66 30 3x 165.8 497.4 LKT 30-400-DP60 65 31-10655 8.11 8.72 10.80 11.61 27.08 12 3x 54.8 164.4 LKT 12-440-DP60 23.6 31-10656 2.68 2.88 3.57 3.84 8.95 9.62 12.00 15 3x 68.5 205.5 LKT 15-440-DP60 29.5 31-10657 3.35 3.60 4.46 4.80 11.19 12.03 15.00 24 3x 109.6 328.8 LKT 24-440-DP60 47.2 31-10658 5.36 5.77 7.14 7.68 17.90 19.24 24.00 30 3x 137.0 411.0 LKT 30-440-DP60 59.1 31-10659 6.70 7.21 8.93 9.60 22.38 24.05 30.00 1 3x 3.8 11.4 LKT 1-480-DP60 1.8 31-10811 0.19 0.20 0.25 0.27 0.63 0.67 0.84 0.90 1.00 1.5 3x 5.8 17.4 LKT 1.5-480-DP60 2.7 31-10812 0.28 0.30 0.38 0.40 0.94 1.01 1.26 1.35 1.50 2 3x 7.7 23.1 LKT 2-480-DP60 3.6 31-10813 0.38 0.40 0.50 0.54 1.25 1.35 1.68 1.81 2.00 2.5 3x 9.6 28.8 LKT 2.5-480-DP60 4.5 31-10814 0.47 0.50 0.63 0.67 1.57 1.68 2.10 2.26 2.50 3 3x 11.5 34.5 LKT 3-480-DP60 5.4 31-10815 0.56 0.61 0.75 0.81 1.88 2.02 2.52 2.71 3.00 4 3x 15.4 46.2 LKT 4-480-DP60 7.2 31-10816 0.75 0.81 1.00 1.08 2.51 2.69 3.36 3.61 4.00 5 3x 19.2 57.6 LKT 5-480-DP60 9 31-10817 0.94 1.01 1.25 1.34 3.13 3.37 4.20 4.52 5.00 6 3x 23.0 69.0 LKT 6-480-DP60 10.8 31-10818 1.13 1.21 1.50 1.61 3.76 4.04 5.04 5.42 6.00 7.5 3x 28.8 86.4 LKT 7.5-480-DP59 13.5 31-10819 1.41 1.51 1.88 2.02 4.70 5.05 6.30 6.77 7.50 10 3x38.4 115.2 LKT 10-480-DP60 18 31-10634 1.88 2.02 2.50 2.69 6.27 6.74 8.40 9.03 10.00 12.5 3x 48.0 144.0 LKT 12.5-480-DP60 22.6 31-10635 2.35 2.52 3.13 3.36 7.83 8.42 10.50 11.29 12.50 15 3x 57.6 172.8 LKT 15-480-DP60 27.1 31-10820 2.82 3.03 3.75 4.03 9.40 10.11 12.60 13.55 15.00 17.5 3x 67.2 201.6 LKT 17.5-480-DP60 31.6 31-10821 3.29 3.53 4.38 4.70 10.97 11.79 14.70 15.81 17.50 20 3x 76.8 230.4 LKT 20-480-DP60 36.1 31-10636 3.76 4.04 5.00 5.38 12.53 13.47 16.81 18.07 20.00 22.5 3x 86.3 258.9 LKT 22.5-480-DP60 40.6 31-10822 4.23 4.54 5.63 6.05 14.10 15.16 18.91 20.32 22.50 25 3x 95.9 287.7 LKT 25-480-DP60 45.1 31-10637 4.69 5.05 6.25 6.72 15.67 16.84 21.01 22.58 25.00 11.25 3x 36.1 108.3 LKT 11.25-525-DP60 18.6 31-10638 1.77 1.90 2.35 2.53 5.89 6.34 7.90 8.49 9.40 10.11 14 3x 44.9 134.7 LKT 14-525-DP60 23.1 31-10639 2.20 2.36 2.93 3.15 7.33 7.88 9.83 10.57 11.70 12.58 22.5 3x 72.2 216.6 LKT 22.5-525-DP60 37.1 31-10640 3.53 3.80 4.70 5.05 11.79 12.67 15.80 16.99 18.81 20.22 28 3x 89.8 269.7 LKT 28-525-DP60 46.2 31-10641 4.40 4.72 5.85 6.29 14.67 15.77 19.67 21.14 23.41 25.16 1 3x 2.5 7.5 LKT 1-600-DP60 1.4 31-10823 0.12 0.13 0.16 0.17 0.40 0.43 0.54 0.58 0.64 0.69 1.00 1.5 3x 3.7 11.1 LKT 1.5-600-DP60 2.2 31-10824 0.18 0.19 0.24 0.26 0.60 0.65 0.81 0.87 0.96 1.03 1.50 2 3x 4.9 14.7 LKT 2-600-DP60 2.9 31-10825 0.24 0.26 0.32 0.34 0.80 0.86 1.08 1.16 1.28 1.38 2.00 2.5 3x 6.1 18.3 LKT 2.5-600-DP60 3.6 31-10826 0.30 0.32 0.40 0.43 1.00 1.08 1.34 1.45 1.60 1.72 2.50 3 3x 7.4 22.2 LKT 3-600-DP60 4.3 31-10827 0.36 0.39 0.48 0.52 1.20 1.29 1.61 1.73 1.92 2.06 3.00 4 3x 9.8 29.4 LKT 4-600-DP60 5.8 31-10828 0.48 0.52 0.64 0.69 1.60 1.72 2.15 2.31 2.56 2.75 4.00 5 3x 12.3 36.9 LKT 5-600-DP60 7.2 31-10829 0.60 0.65 0.80 0.86 2.01 2.16 2.69 2.89 3.20 3.44 5.00 6 3x 14.7 44.1 LKT 6-600-DP60 8.7 31-10830 0.72 0.78 0.96 1.03 2.41 2.59 3.23 3.47 3.84 4.13 6.00 7.5 3x 18.4 55.2 LKT 7.5-600-DP60 10.8 31-10831 0.90 0.97 1.20 1.29 3.01 3.23 4.03 4.34 4.80 5.16 7.50 10 3x 24.6 73.8 LKT 10-600-DP60 14.4 31-10642 1.20 1.29 1.60 1.72 4.01 4.31 5.38 5.78 6.40 6.88 10.00 12.5 3x 30.7 92.1 LKT 12.5-600-DP60 18 31-10643 1.50 1.61 2.00 2.15 5.01 5.39 6.72 7.23 8.00 8.60 12.50 15 3x 36.8 110.4 LKT 15-600-DP60 21.7 31-10832 1.80 1.94 2.40 2.58 6.02 6.47 8.07 8.67 9.60 10.32 15.00 17.5 3x 43.0 129.0 LKT 17.5-600-DP60 25.3 31-10833 2.10 2.26 2.80 3.01 7.02 7.55 9.41 10.12 11.20 12.04 17.50 20 3x 49.1 147.3 LKT 20-600-DP60 28.9 31-10644 2.40 2.58 3.20 3.44 8.02 8.62 10.76 11.56 12.80 13.76 20.00 22.5 3x 55.3 165.9 LKT 22.5-600-DP60 32.5 31-10834 2.70 2.91 3.60 3.87 9.03 9.70 12.10 13.01 14.40 15.48 22.50 25 3x 61.4 183.3 LKT 25-600-DP60 36.1 31-10645 3.00 3.23 4.00 4.30 10.03 10.78 13.44 14.45 16.00 17.20 25.00 12.5 3x 23.2 69.6 LKT 12.5-690-DP60 15.7 31-10646 1.14 1.22 1.51 1.63 3.79 4.08 5.08 5.46 6.05 6.50 9.45 10.16 15 3x 27.9 83.7 LKT 15-690-DP60 18.8 31-10647 1.36 1.47 1.81 1.95 4.55 4.89 6.10 6.56 7.26 7.80 11.34 12.19 20 3x 37.1 111.3 LKT 20-690-DP60 25.1 31-10648 1.82 1.95 2.42 2.60 6.07 6.52 8.13 8.74 9.68 10.40 15.12 16.26 25 3x 46.4 139.2 LKT 25-690-DP60 31.4 31-10649 2.27 2.44 3.02 3.25 7.58 8.15 10.17 10.93 12.10 13.01 18.90 20.32 30 3x 55.7 167.1 LKT 30-690-DP60 37.7 31-10650 2.73 2.93 3.63 3.90 9.10 9.78 12.20 13.11 14.52 15.61 22.68 24.39 12.6 3x 17.4 52.2 LKT 12.6-800-DP60 13.6 31-10661 0.85 0.92 1.13 1.22 2.84 3.06 3.81 4.10 4.54 4.88 7.09 7.62 16 3x 22.1 66.3 LKT 16-800-DP60 17.3 31-10662 1.08 1.16 1.44 1.55 3.61 3.88 4.84 5.20 5.76 6.19 9.00 9.68 25.2 3x 234.8 104.4 LKT 25.2-800-DP60 27.3 31-10663 1.70 1.83 2.27 2.44 5.69 6.11 7.62 8.19 9.07 9.75 14.18 15.24

Power Factor Correction s LKT Transfab TMS 175, Jules-Léger Boucherville (QC) J4B 7K8 Canada Phone: 1 866 540 0412 Fax: 450 449 9115 salestms@transfabtms.com transfabtms.com FRAKO 95-00321 / 07/12/8815 Subject to technical changes