Mechanical mixing box MBM

Similar documents
Technical documentation

Additional operating instructions according to ATEX 94/9/EC Volumetric flow controller VM-PRO-Ex

Volumetric Flow Limiter VOLKOM

ceiling swirl diffuser Model DQJA / DQJR

Ceiling diffuser 4DE

ceiling swirl diffuser DQJ

LAQ Return air diffuser

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

Round duct diffuser DBB-RR

WGA Long throw nozzle grille

Long Throw Nozzle WDA

Ceiling diffuser 4DF

Nozzle Jet Diffuser Model DSA

Swirl Diffuser Model DQF

Round duct grille Model KG-RR

Ceiling induction diffuser DISA-300

Mixing Box MBE / MBP

Fan coil unit NBS 100/150

Ceiling induction diffuser DISA-601

Ceiling Slot Diffuser Model DSX

Ceiling impulse diffuser Model PIL

Lint separator FLARE

Particle Filter Box FKU

Particle Filter Box Model FKF

Ceiling Slot Diffuser DSC

Round Duct System Model RR-Complete

Ceiling Slot Diffuser DSC

Ceiling Slot Diffuser DSC

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Ventilation grille Model AL

volumetric flow controller Model VRA-Q Smart

Air diffuser system Model AUDIX -AW

Round Duct System Model RR-Complete

Ceiling Swirl Diffuser DQJ

VARYCONTROL VAV Dual Duct Terminal Boxes

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Ventilation grille Model IB-R

DSC-PLASTER Slot diffuser for plasterboard ceilings

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Round Duct System Accessories RR - accessories

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Compact Grille Model KG

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

CONSTANTFLOW Volume Flow Controllers

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Ventilation Grille PA

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

CAV controllers Type RN

Weather protection grille ALAS

Ceiling swirl diffusers

Ceiling swirl diffusers with perforated face plate

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

BSK-EN Fire damper INSTALLATION, MOUNTING AND OPERATING INSTRUCTIONS

Ceiling swirl diffusers

Fire damper BKA-EN. with general technical approval Z tested according to DIN EN

Parts and characteristics

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Slot diffusers for ceiling installation

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

series RVV Variable flow rate controllers

VOLUME CONTROL / REGULATING DAMPERS

Air Displacement Vent Units

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

CRP. Commissioning damper, Ductwork Leakage Class 0 QUICK FACTS. Perforated damper blade for better damper characteristic

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

Ceiling swirl diffusers

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

IrisControlDamper. For Adjustment and Measuring of Airflow.

TBV - Terminal Unit. Halton TBV. Terminal Unit

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Ceiling swirl diffusers with perforated face plate

Volume Flow Limiters Type VFL

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

UTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

CAV-S Mechanical constant volume fl ow controller, steel

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

VAV TERMINAL BOXES TYPE: BA BT

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Fire Dampers. Types FKA FRL FRK 4/1/EN/1

Fan - Powered Terminal Unit Series Flow

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Transcription:

Mechanical mixing box MBM Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de

Contents Description...3 Construction... 3 Model... 3 Accessories... 3 Models and dimensions...4 Dimensions...4 MBM 100-315...4 Dimensions of accessories... 5 Technical data...7 Volumetric flow range... 7 Flow generated noise... 7 Radiated noise... 7 Setting curves for air volume regulation... 8 Minimum pressure differences... 9 Circuit diagram... 10 Legend... 10 Order details... 10 Specification text... 10 Z08/22 -

Description Mixing boxes are used in twin-duct air-conditioning systems. The Mixing Box Model MBM consists of a casing with two circular connections and an integrated sound absorber for reducing noise generated by flow. The round connection spigots contain elliptical control flaps, which are responsible for regulating the air temperature. The unit mixes cold and hot air in such a way that the difference between the highest and the lowest temperature at the outlet of the device is less than 10%. The actuator for the cold and hot air dampers, which are mounted offset to one another by 60 and are connected via a lever system, forms a control circuit together with the room temperature control and is managed by the room temperature control. If the requirement for cooling increases, the cold air flap is opened via the adjusting signal of the room temperature controller and the warm air flap is closed accordingly. If the adjusting signal falls back again, then both flaps are respectively adjusted in opposite directions. The supply air volume is controlled by the second control circuit via one or two constant volumetric flow controllers independently of the duct pressure, for which a constant volumetric flow controller with electric setpoint value adjustment can be used at an extra charge. If the supply air or return air volume must be adjusted to variable room occupations, etc., this can be done using a constant volumetric flow controller equipped with an actuator without opening the false ceiling. The setting values and control signals for actuators with constant control can be obtained from the documentation. For OPEN/CLOSED actuators, the controller setting is achieved by a mechaniical limiter. The measurement voltage U (2-10 V DC) can be used for position feedback or as subsequent control signal. The motors are arranged on the underside of the unit, in order to allow them to be checked through the inspection opening in the false ceiling. The setpoint values are initially set ex works, during which all dual duct terminal boxes are checked for correct functioning. For maintenance, service, retrofitting, etc., inspection openings in sufficient number and size must be provided on-site. Field of application - for supply air systems - for constant volumetric flows - Differential pressure range 250-1000 Pa - for ambient temperatures from 0 to 55 C - for air velocities in the duct from 2 to 12 m/s - Supply voltage actuator 24 V AC, 50/60 Hz - Model for spiral duct connection according to DIN EN 1506 - with integrated silencer unit to reduce flow generated noise - additional acoustic cladding to reduce radiated noise available at an extra charge Attention! The cold-air connection spigot must be insulated on site if there is a risk of condensate formation. Construction Housing - Galvanised sheet steel, abrasion-resistant up to a duct velocity of 20 m/s Damper unit - lined with mineral wool, abrasion-resistant Hot/cold air damper control - Standard model: 2-/3-point via NM24A (1 actuator) - Special model: continuously via NM24A-SR (1 actuator) - Special model: pneumatically via AK 31 P (1 actuator) Silencer unit - lined with mineral wool, abrasion-resistant Hot and cold air control damper - Galvanised sheet steel, with silicone-free damper leaf seal made of PUR for airtight seal according to DIN EN 1751, class 3. Model MBM 100-250 MBM 315 MBM 400 Accessories - with a mechanical volumetric flow controller VM-PRO 100 to 250 - with two mechanical volumetric flow controllers VM-PRO 250 - with three mechanical volumetric flow controllers VM-PRO 250 Acoustic cladding (-DS) - Galvanised sheet steel with 40 mm mineral wool lining Rubber lip seal (-GD) - Special rubber Duct silencer (-RS) - Galvanised sheet steel with mineral wool lining and perforated cover Attention! The activation of the continuous actuator NM24A-SR takes place via a 0-10V DC signal, whose working range is 2-10V DC. 2V DC corresponds to the 0% position of the actuator and 10V DC to the 100% position. Z08/22-3

Models and dimensions Dimensions MBM 100-315 View A Through-hole ø10 View B Rivet nut M8 Available sizes NW L L1 H B B1 ød a b c e 100 240 98 210 170 125 1100 910 265 123 235 200 135 160 300 704 660 158 270 584 230 200 1305 1115 340 198 310 260 155 250 1520 1330 390 248 360 300 180 315 1585 1280 455 1104 1060 313 425 984 410 255 MBM 400 View C Through-hole ø10 View D Rivet nut M8 Z08/22-4

Dimensions of accessories Acoustic cladding (-DS) View E View F Available sizes NW DH DB DB1 100 320 125 345 160 380 784 740 200 420 250 470 315 535 1184 1140 400 620 1224 1180 Inspection openings are provided at the underside of the unit, in order to allow the constant volumetric flow controller to be checked and adjusted. Rubber lip seal (-GD) Detail X Z08/22-5

Duct silencer (-RS) Socket ends on-site Available sizes NW ød ød P (mm) 50 100 150 100 98 200 300-125 123 225 325-160 158 260 360-200 198 300 400-250 248 350 450-315 313 415 515 615 400 398 500 600 700 Selection chart packing thickness NW L (RS) = 500 L (RS) = 950 L (RS) = 1450 L (RS) = 1950 P (mm) P (mm) P (mm) P (mm) 50 100 50 100 150 50 100 150 50 100 150 100 x x x x - x - - x - - 125 x x x x - x - - x - - 160 x x x x - x x - - x - 200 x x x x - x x - - x - 250 x x x x - x x - - x - 315 x x x x x x x x - - x 400 x x x x x x x x - - x x = available - = not available P = Packing thickness Z08/22-6

Technical data Volumetric flow range NW (m³/h) (l/s) min. max. min. max. 100 70 260 19 72 125 120 420 33 117 160 180 700 50 194 200 250 1200 69 333 250 300 1500 83 417 315 600 3000 167 833 400 900 4500 250 1250 Flow generated noise NW L WA [db(a)] (m³/h) [l/s] Δp t = 250 Pa Δp t = 500 Pa 70 19 24 28 100 130 36 27 31 210 58 31 36 260 72 33 38 120 33 26 30 125 240 67 31 34 340 94 34 38 420 117 36 39 180 50 28 32 160 420 117 33 37 580 161 36 40 700 194 38 42 250 69 28 32 200 575 160 32 36 925 257 37 41 1200 333 41 45 300 83 29 34 250 750 208 32 36 1175 326 35 38 1500 417 38 40 600 167 29 27 315 1500 417 38 42 2350 653 42 46 3000 833 44 48 900 250 34 38 400 2250 625 39 43 3525 979 44 48 4500 1250 47 51 Radiated noise without acoustic cladding / with acoustic cladding (-DS) 40mm NW 100 125 160 200 250 315 400 (m³/h) [l/s] without acoustic cladding L WA [db(a)] Δp t = 250 Pa Δp t = 500 Pa with acoustic cladding L WA [db(a)] Δp t = 250 Pa Δp t = 500 Pa 70 19 29 33 25 29 130 36 32 36 28 32 210 58 37 40 32 36 260 72 38 42 34 38 120 33 31 35 27 31 240 67 35 40 32 35 340 94 39 42 34 38 420 117 41 44 35 39 180 50 33 37 30 33 420 117 37 41 34 38 580 161 40 43 36 40 700 194 42 45 37 41 250 69 32 37 29 34 575 160 38 42 35 39 925 257 43 47 38 43 1200 333 45 49 40 44 300 83 34 39 31 33 750 208 38 43 35 40 1175 326 42 47 37 42 1500 417 44 49 38 43 600 167 34 38 31 35 1500 417 41 43 37 40 2350 653 43 46 39 43 3000 833 45 48 41 45 900 250 37 39 29 31 2250 625 42 43 36 40 3525 979 46 46 40 43 4500 1250 48 48 42 45 Z08/22-7

Setting curves for air volume regulation Controller setting MBM 250 Controller setting MBM 100 Controller setting MBM 315 Controller setting MBM 125 Controller setting MBM 400 Controller setting MBM 160 Controller setting MBM 200 RS = controller setting For correct design and use of the dual duct terminal box MBM, we recommend not exceeding the max. controller setting of 10. This ensures that the mechanical constant volumetric flow controller is working in the optimum range. Attention! The MBM 315 is equipped with 2 VM-PRO-250, both constant controllers being activated in parallel, i.e., the air volume must be calculated twice. Attention! The MBM 400 is equipped with 3 VM-PRO-250, all constant controllers being activated in parallel, i.e., the air volume must be calculated three times. Z08/22-8

Minimum pressure differences NW 100 125 160 200 250 315 400 Mixing ratio 100/0 50/50 100/0 50/50 100/0 50/50 100/0 50/50 100/0 50/50 100/0 50/50 100/0 50/50 Hot/cold air Controller position 1 2 3 4 5 6 7 8 9 (m 3 /h) 70 120 180 250 300 600 900 [l/s] 19 33 50 69 83 167 250 Δp t min (Pa) 71 74 75 79 67 71 59 62 54 54 67 70 67 70 (m 3 /h) 80 160 280 325 400 800 1200 [l/s] 22 44 78 90 111 222 333 Δp t min (Pa) 75 79 83 91 85 94 75 80 71 73 75 79 75 79 (m 3 /h) 105 200 360 450 575 1150 1725 [l/s] 29 56 100 125 160 319 479 Δp t min (Pa) 85 95 90 103 96 111 86 95 110 116 89 95 89 95 (m 3 /h) 130 240 420 575 750 1500 2250 [l/s] 36 67 117 160 208 417 625 Δp t min (Pa) 97 113 104 122 115 134 97 113 145 156 98 108 98 108 (m 3 /h) 160 275 480 700 900 1800 2700 [l/s] 44 76 133 194 250 500 750 Δp t min (Pa) 110 129 127 151 144 170 126 149 167 183 116 132 116 132 (m 3 /h) 185 310 540 825 1050 2100 3150 [l/s] 51 86 150 229 292 583 875 Δp t min (Pa) 140 165 162 191 186 219 177 209 187 208 145 167 145 167 (m 3 /h) 210 340 580 925 1175 2350 3525 [l/s] 58 94 161 257 326 653 979 Δp t min (Pa) 185 217 202 237 222 260 233 273 201 227 176 203 176 203 (m 3 /h) 225 370 625 1025 1300 2600 3900 [l/s] 63 103 174 285 361 722 1083 Δp t min (Pa) 216 254 245 287 263 308 393 341 217 250 209 243 209 243 (m 3 /h) 245 400 670 1100 1400 2800 4200 [l/s] 68 111 186 306 389 778 1167 Δp t min (Pa) 267 312 298 347 307 357 343 398 233 270 234 273 234 273 10 V (m 3 /h) 260 420 700 1200 1500 3000 4500 ZU [l/s] 72 117 194 333 417 833 1250 Δp t min (Pa) 305 356 329 383 339 395 423 490 249 292 262 306 262 306 100/0 = Mixing ratio of hot air to cold air 100% to 0% 50/50 = Mixing ratio of hot air to cold air 50% to 50% Z08/22-9

Circuit diagram Actuator make Belimo Type NM24A/NM24A-SR/SM24A/SM24A-SR OPEN/CLOSED control 3-point control Order details Mixing Box type MBM NW 100 125 160 200 250 315 400 Control damper regulation OPEN/CLOSED -NM24A Accessories: Acoustic cladding -DS Control damper regulation continuous -NM24A-SR Rubber lip seal -GD Activation 0-10V DC (2-10V DC) Notes - Connection via safety transformer. - Parallel connection of further drives is possible. - Observe specifications. Legend DC 0...10V DC 2...10V Direction of rotation (m³/h) = Supply air volumetric flow [l/s] = Supply air volumetric flow DS (mm) = Thickness of the acoustic cladding 40mm RS - = Duct silencer P (mm) = Packing thickness NW (mm) = Nominal width Δp t (Pa) = Pressure loss Δp t min (Pa) = Minimum static pressure difference L WA [db (A)] = A-weighted sound power level (room and ceiling damping not yet included) Duct silencer -RS Order example: MBM-200-NM24A Unless stated otherwise, the thick-frame model will be delivered. Specification text Dual duct terminal box for use in twin-duct air-conditioning systems, including two round connection spigots arranged at an angle of 120, relative to one another, with control flaps with damper leaf seal made of PUR, fits ducts according to DIN EN 1506, sealing airtight to DIN EN 1751, class 3. Fitted with integrated mechanical constant volumetric flow controller type VM- PRO in round design, in which the mechanics and damper are in a closed control unit outside the air flow, insensitive to contamination. Differential pressure range from 250 to 1,000 Pa, volumetric flow deviation ±5 %, relative to the V max volume. Galvanised sheet steel housing with integrated silencer unit with thermal and acoustic mineral wool lining, abrasion-resistant up to an air velocity of 20 m/s. With nominal widths 100 und 125 mm, the control damper and damper axis are made of galvanised sheet steel. Regulation of cold/hot air damper continuously or via 3-point signal, supply voltage 24V AC, 50/60 Hz, ambient temperature 0-55 C. Product: SCHAKO type MBM Accessories (at an extra charge) - Acoustic cladding (-DS) made of sound-damping mineral wool thickness 40 mm, with sheet metal casing made of galvanised sheet steel - Duct silencer (-RS), outer casing and perforated sheet made of galvanised sheet steel with mineral wool filling. - Rubber lip seal (-GD), made of silicone-free special rubber. Z08/22-10