PTZ CAMERA. User Manual WE DO FUTURE. Ver. 1.2

Similar documents
SDOMEO51MV USER MANUAL. Portable Rugged PTZ Cameras

ICVS-TX MOBILE DUAL IMAGER THERMAL PTZ CAMERA USER MANUAL

TWINCAM USER MANUAL Portable All-Condition Rugged PTZ Camera

USER MANUAL. Rugged Weatherproof Mobile PTZ Camera. (IR and White Light Versions)

1. Check that the packing and the contents are not visibly damaged. Contact the retailer

USER MANUAL. Portable All-Condition Rugged PTZ Camera. (Thermal Imaging Version)

HTC-240P/HTC-240W INSTRUCTION MANUAL

22X MINITRAX III DOME CAMERA

22X PTZ III DOME CAMERA

CAM-PTZ-AUT Tracking Module for PTZ Camera Installation & User Manual

22X MINITRAX III DOME CAMERA

22X PTZ III DOME CAMERA

OWNER S MANUAL Dome Camera

INSTRUCTION MANUAL 22X MINITRAX III Lite DOME CAMERA

OWNER S MANUAL Dome Camera

PTZDECO241 Pan/Tilt/Zoom RS-485 receiver. Please read this manual carefully before use product!

DLD6440 Protocol Converter

Speed Dome 66 Installation Manual

PowerView PV380-R2 Mechanical Configuration

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

TruVision HD-TVI Series 4 PTZ Dome Camera Installation Guide

Warnings & Cautions. Components CAUTION

TruVision HD-TVI PTZ Camera (TVP-6101/ TVP-6102/ TVP-6103) Installation Guide

OUTDOOR SPEED BOME CAMERA MINI HIGH SPEED DOME CAMERA

INSTALLER MANUAL USER MANUAL. Contents

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Installation Guide. BBV Protocol Converter. BBV single camera protocol converter. Software version CONV3V39

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

Compact LED profile with zoom

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

Instruction Manual. Backup Camera System For Pickup Trucks. RVS-Pickup

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

PACKAGE LIST CONTENT. User Manual 1 GIMBAL STABILIZER 1 MICRO USB CABLE 1

CONTENTS 1.0 INTRODUCTION SAFETY... 5

Interactive Whiteboard. User Guide. Before operating the unit, please read this manual thoroughly, and retain it for future reference

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

ES30C/ES31C Series Esprit with IOP

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

B-RAD Select USER MANUAL TABLE OF CONTENTS

WARNING. This shows the detail that could lead to death or severe injury if ignored or through misuse the product.

TIRE PRESSURE AND MONITORING SYSTEMS (DIAGNOSTICS)

Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT

Digital Mounted Machinegun Optic (DMMO) Enhancing Crew Served Weapons (M2HB)

SE8300 Series Installation Guide 24 Vac Low Voltage

MODEL 422 Submersible Pump Controller

Owner's Manual. Remote Security and Convenience System INS0866 8/98

Inline Ultrasonic Flowmeter

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

SAFETY PRECAUTIONS Warning: Read and understand all instructions in this manual. Use appropriate personal safety equipment including hearing and eye p

Instructions manual / Position Controller 1. GY-G Series INSTRUCTIONS MANUAL

Instruction Manual. Backup Camera System With Replacement Mirror Display RVS N

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

User Manual Solar Charge Controller 3KW

AVH-2330NEX AVH-2300NEX AVH-1330NEX AVH-1300NEX

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

MATRIX LLC LEVEL CONTROL PANEL

SE8300 Series Installation Guide 24 Vac Low Voltage

AVH-601EX AVH-600EX AVH-501EX AVH-500EX

TYPE 5867 PORTABLE Q METER

INDEX. 1.Safety Precautions and Warnings...3

DIESEL Engine Fire Pump Controllers Features

TOWA SEIDEN INDUSTRIAL CO., LTD.

USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS

Multi Wheel Bluetooth Tire Pressure Monitoring System User Manual Model: External

CX-SERIES ADVANCED BATTERY CHARGER

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Instruction Manual. Backup Camera System With Replacement Mirror Monitor RVS

UNITED STATES Ford Customer Relationship Center (FORD) (TDD for the hearing impaired: ) owner.ford.

Installation Instructions

OpenEVSE - 40A Charging Station

Signet 2551 Magmeter Flow Sensor

Combined Ventilation Controller RVWS-T-224HA

TE-HUD User Manual. l ::: J TECH SUPPORT. MetraDealer.com

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

HUD Vehicle Mounted Head Up Users Operation Instruction Manual

Rotel RSX-1065 RS232 HEX Protocol

User s Manual XOB15091 OBD II / EOBD CODE READER. All Rights Reserved. Warranty and Service

AD1240 Champion Series Outdoor, Medium Duty Pan/Tilt

ELECTRIC ACTUATOR S20 - S35 - S55 - S85

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Service Manual BLACK DIAMOND SERVICE MANUAL. V.160 November

Gate & Door Controller with LCD and Intelligent Technology

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual

TOUCH PLS TOUCHSCREEN PLS A NEW HORIZON IN PROGRAMMABLE LIMIT SWITCHES

User Manual. Solar Charge Controller 3KW

Differential Pressure Transmitter

Uninterruptible Power System

Rotel RSX-1067 RS232 HEX Protocol

A-200 Speed Dome. Quick Start Guide UD.6L0201D0127A02

Model TUR-200D Turbine Flowmeter

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

Product Guide: Series III Pump Control Board Set (RoHS)

PV Generation System. Solar Charge Controller SPECIFICATION

StepSERVO Tuning Guide

Roll Up Door Operator

User manual. Standard Modular Chiller HP 1/8 compressors with CAREL driver Application program for pco 1, pco 2, pco 3, pco C and pco XS.

Transcription:

WE DO FUTURE User Manual Ver. 1.2 0.009º Dome System Accuracy / 220 Preset Position / Extrnal Firmware Upgrade (RS-485) / Home Position & Recover / Slip Ring For Long Life Time / Proportion PTZ Control

Contents Components CONTENTS 2 COMPONENTS 3 WARNINGS & CAUTIONS 4 GENERAL FEATURES 5 PART NAMES 7 A. Basic Parts 7 B. Additional Accessorries 7 INSTALLATION 8 QUICK OPERATING KEYS 11 DIAGNOSTIC 13 OSD MENU SETTING 14 A. Main Menu 15 B. Dome Setup 15 C. Dome Setup #2 [Next Page] 17 D. Camera Set 19 E. Preset 24 F. Autoscan 25 G. Tour 27 H. Privacy 28 I. Pattern 29 J. Alarm 30 K. Sector 32 DIP SWITCHING SETTING 33 A. ID Setting 33 B. 485 Termination 39 C. Function 39 TROUBLESHOOTING 40 SPECIFICATION 41 DIMENSIONS 44 PTZ Camera BOTTOM CASE CAMERA IR LED TOP CASE BUBBLE DIP Switch DIP Switch Cover Accessaries L-WRENCH - 1EA SCREW M4 18-4EA WALL MOUNT BRAKET - 1EA SET ANCHOR BOLT W5/16-4EA 002 003

Warnings & Cautions General Features IR If you fail to read this information and handle the product incorrectly, death or serious injury may occur. The unit should be installed by trained personnel. Switch off immediately if the product emits smoke or abnormal heat. Never install the product in an area with exposed oil or gas. Never install the product on a ceiling that cannot hold its weight. Never touch the power cord with wet hands. Clean only with dry cloth. Never install the product in extreme high or low temperature. Never drop, hit strongly or cause the product to vibrate. Never expose the product to direct sunlight or severe ray. INDOOR / OUTDOOR APPLICATIONS The domes small size and construction to IP 66 ingress protection rating make it ideal for internal or external applications. 0.009º DOME SYSTEM ACCURACY WITH 1/16 MICRO STEP With 0.009º technical accuracy, camera provides excellent sensitive and delicate controlling on preset mode by adapting 1/16 micro step and twin gear system. RELIABLE RAM-MATERIAL The mechanical stabilization improves the durability and long life time of the camera by using reliable materials especially, stepping motor, slip ring, timing belt and power condenser. This camera case is made of fire resisting material that approved UL grade 94 V-0. It is useful for indoor environment concerning about the fire accident. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN COMPENSATION FUNCTION: PRESET POSITION The function provides absolute preset position even in difficult applications where vibration and strong winds may otherwise affect dome performance. SLIP RING FOR LONG LIFE TIME (20MILION ROTATE RING TESTED) Equipped with slip ring is passed by up to 20 millions rotate ring test within 6 months. CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. POWER MISCONNECTION PROTECTION ON 485 TERMINALS This protection function prevents the communication terminal from being out and trouble when power source falsely connects to the RS-485 terminals. Hi speed dome got a patent for power misconnection protection on RS-485 terminal. FILTER CHANGEABLE TRUE DAY/NIGHT Top quality images are assured under day and night conditions due to the true day / night camera with IR cut filter. Low light sensitivity is further increased by the cameras digital slow shutter. QUICK OPERATION KEYS This camera provides quick function keys to allow control by most keyboards and DVRs that have Pelco protocol support. 004 005

General Features Installation IR VARIOUS SURVEILLANCE FUNCTIONS Auto Scan repeats pan and tilt between two preset positions with different speed and dwell time. 8 Group Tour up to 8 Programmable Group tours available and each group is consisting up to 60 presets step with different speed and dwell time with 16 characters. 220 Preset positions up to 220 programmable preset positions are available with 16 characters. 8 Patterns up to 8 programmable user-defined patters are available with 16 characters and each one is consisting 50 seconds, total 400. 8 Sectors up to 8 programmable user-defined sectors are available with 16 characters. 8 Privacy Masking Zones up to 8 programmable user-defined privacy masking zones are available with 16 characters.(18x, 26X only) 4 Alarm input and 2 relay out up to 4 alarms and 2 relay out available to match with preset, tours, patterns. Remove the protection of cover attached each component after picking the product out from box. Remove the protection of film from Top case. 400º/S, 350º/S ON PRESET SPEED The 360º full pan function moves through a maximum of 400º /sec., enabling you to quickly pinpoint the spot you want to watch. Tilt speed provides through a maximum 350º /sec on preset. On preset mode, the camera is set up to 400º /sec. MULTIPLE LANGUAGES AND PROTOCOLS To convenience for the customers, this camera provides several languages and protocols including English, Italian, Polish and Pelco D, Pelco P and Ultrak protocol. Take the protection of film of Camera Lens out from Bottom Case. INTELLIGENT PAN/TILT CONTROLLING Pan and tilt speed compensation function linked to zoom position. Remove the protection of cushion from Bottom Case 006 007

Installation Installation IR Unite both Top Case and Bottom Case using + driver. (Screw Locking Torque : 8.0 kgf.cm) Get wiring through to the back side of wall pushing to hole inside of bracket. Set up the bracket which is packed with product as option on the wall. Make a decision the place for Camera angle in order not to be bothered. Just double-check the wiring hole whether it is size enough or not and then set it up horizontally. Unite with product using screw M4 18 from top of bracket. (Screw Locking Torque : 10.0 kgf.cm) Unite with the product if setting for bracket is done. Connect both Safety Wire and product first because product is heavy. Make the setting over after doublecheck both horizon and position of product. 008 009

Quick Operating Keys Quick Operating Keys IR The dome supports Pelco-D/P, SAMSUNG and VICON i3dvr(sae) protocols. The dome may be used with any controller or DVR etc that supports the Pelco D and Pelco P protocols. The default setting of the dome is Pelco D / P (auto detection) with 2400 bps (baud rate). [PELCO D/P PROTOCOLS] The comprehensive feature set of the dome is available from Pelco compatible controllers via quick operation keys as defined below. 1~64 + preset and 100~255 + preset are used for normal user presets. Presets 65-99 + are reserved for special functions. For example, to enter OSD MENU, press the button 95 + PRESET 65 + preset : "Preset Status" is displayed, to remove this screen, press Focus Near button. 70 + preset : This feature provides picture stabilization image. 92 + preset : This feature freezes the current live image during tour, auto scan or pattern operation. When you press 92 + preset button, the image freezes but the camera is still working as per operation such as tour, pattern or auto scan. This feature is operated by preset number but not included in OSD main menu. To return to normal images, press 92 + preset button again. Due to Zoom camera module, OSD Menu not provides every feature. In this case, "Not available" is displayed on the monitor. <Quick Operation Key Table 1> Number Note Function 1~64,100~255 +Preset Preset Executing Preset 1 ~ 64, 100~255 65 +Preset Preset Status Display Preset Status 66 +Preset Auto Scan Executing Auto Scan 67 +Preset Auto Flip Selectable On/Off in Auto Flip mode 70 + Preset VIB CORR Selectable On/Off in Picture Stabilization function 71~78 + Preset Group Tour Executing Group Tour #1 ~ #8 81~88 + Preset Pattern Executing Pattern #1 ~ #8 91 + Preset Zero Position Searching Pan / Tilt Zero Position 92 + Preset Freeze Select Freeze image when camera is working 93 + Preset BLC Selectable On/Off in BLC function 94 + Preset Day / Night Selectable Day / Night / Auto Mode 95 + Preset OSD Entering OSD Main Menu 96 + Preset Focus Adjust Focus adjust 97 +Preset Alarm Selectable Enable/Disable all Alarms 98 +Preset AUX 1 Selectable On/Off in Aux1 99 +Preset AUX 2 Selectable On/Off in Aux2 <Quick Operation Keys Table 2: Use these function keys if controller has these keys> Menu Function Tilt Up / Down Sub menu cursor moves up / down Pan Left / Right Enter to the sub menu or status change or decrement Focus Near Using for Enter key when user select YES or NO Focus Far Using for function changing keys when set coordinate Zoom Tele Status cursor to the right Zoom Wide Status cursor to the left 010 011

Diagnostic OSD Menu Setting Whenever the dome is powered on, a standard diagnostic is operated. To enter OSD Menu, press the button 95+Preset than OSD Main Menu is displayed MAIN MENU CAMERA ID : 001 BAUD RATE : 2400BPS WAITING... PAN ORIGIN TILT ORIGIN TX CONNECTION CAMERA COMM TEST OK TEST OK TEST OK TEST OK DOME SETUP CAMERA ID HOME POS MANUAL SPEED AUTO FLIP ZOOM SPEED ALARM LANGUAGE [NEXT PAGE] SAVE AND : CAM1 : 150º/S : FAST : DISABLE : ENGLISH SYSTEM LOCK [PASS WORD] [OSD DISPLAY] [SYSTEM STATUS] [INITIALIZATION] [PREVIOUS PAGE] [NEXT PAGE] A. Pan Origin Test Zero point of Pan is located during the Panning test. B. Tilt Origin Test Zero point of Tilt is located during the Tilt test. C. TX connection Test Wait for 60 seconds for TX Connection Test, During 60 seconds, the camera is must received a signal by any control equipment as DVR or controller. Then Ok is displayed then automatically verifying TX Connection Test. * If "Not Tested" is displayed in the test, - The result which is not received any signal from DVR or controller - Wrong connecting way such as the protocol, baud rate or RS-485 connection. The use may check the install way carefully. D. Camera Comm. Test Camera communication is also checked. OK should be displayed in these four tests before installation. If all the above Tests are OK, NOW EEPROM CHECKING and ALL DATA INITIALIZING is displayed and the camera is ready to operate. CAMERA SET PRESET AUTOSCAN TOUR PRIVACY PATTERN ALARM SECTOR SET SHUTTER : FULL AUTO MIRROR APERTURE : 16 D ZOOM WB MODE : ATW MODE BLC [BLC] D/N MODE :AUTO MODE [SLOW] [NEXT PAGE] PRESET NO : 001 PRESET ID : PRESET001 PAN : 123.2 TILT : 89.2 FREEZE MODE FREEZE ALL SAVE TOUR NO. : 01 TOUR TITLE : TOUR01 TOUR STEP : 01 PRESET NO. : 001 DWELL TIME : 03 SPEED : 300º/S SAVE PATT NO : 01 PATT TITLE : PATTERN01 DATA FILL : 012% SAVE SECTOR NO. : 01 SECTOR ID : SECTOR1 SECTOR START : 334.7-1.6 SETCOR END : 000.4 08.8 SAVE [NEXT PAGE] SENSE UP : X2 AGC MODE : MIDDLE SSNR MODE : MIDDLE COLOR : 050 DIS MODE IRIS SET : AUTO [PREVIOUS PAGE] START ANGLE : 250.5 35.0 END ANGLE : 320.0 35.0 DIRECTION : CW ENDLESS SPEED : 10º/S DWELL TIME : 01 SAVE AND PRIVACY NUMBER : 01 DISPLAY ACTION : MOVE SAVE ALARM NO. : 0.1 ALARM INPUT ALARM ACT : 001 AUX ACT : BLC SAVE 012 013

OSD Menu Setting IR OSD Menu Setting A. MAIN MENU To enter OSD Menu, press the button 95+Preset [Maxpro 90+Preset] than OSD Main Menu is displayed. B. DOME SET MAIN MENU DOME SETUP CAMERA SET PRESET AUTO SCAN TOUR PRIVACY PATTERN ALARM SECTOR It can be possible to enter into Main Menu by using Menu Key or 95+Preset of controller. DOME SET CAMERA ID : CAM1 HOME POS MANUAL SPEED : 150º/S AUTO FLIP ZOOM SPEED : FAST ALARM : DISABLE LANGUAGE : ENGLISH [NEXT PAGE] SAVE AND You can enter into Dome Set by using Controller Joystick of Left/Right after choice Dome setup from MAIN MENU OSD. B-1. CAMERA ID This is for set up the ID String and Possibly exchange to other word as users want, 16Bytes in total. Exchange into other word by using Left/Right of controller joystick and move Left/Right by using Zoom in/zoom Out. The word changed should be signed top of the left on ON/OFF Setting from "OSD DISPLAY" MENU B-2. HOME POS This is ability of HOME POSITION, basically include RECOVER. If you have it ON, Number and relevant ability would be showed up. Time is for Number, relevant ability is for operation. Possible to set up the time by using Left/Right of Joystick, if you press the Focus Far Key, would be showed up on the left side of Menu, and "[ ]" can be changed into other ability by using Left/Right as users want. If you press the Focus Far Key after finish setting of "[ ]", should be taken off and escaped from "[ ]". Possible time of setting: 15~90(Possibly setting as 5unit.) Possible list of setting: [AUTO] - RECOVER function performance. (Performed ability movement last time.) [PRST1] ~ [PRST8] - PRESET1 ~ PRESET8 movement [TOUR1] ~ [TOUR8] - TOUR1 ~ TOUR8 movement [PATT1] ~ [PATT8] - PATTERN1 ~ PATTERN8 movement [SCAN] - AUTOSCAN movement B-3. MANUAL SPEED You can set it up by 100º~250º/sec with maximum speed when user control PAN/TILT. B-4. AUTO FLIP Possible setting up the ON/OFF, on ON, angle of the tilt should be approached to 90º while PAN/TILT. In case of controlling automatically, Tilt would be located by -2º after circuit 180º. That means, possible to check the area of 184º. B-5. ZOOM SPEED Possibly set up the Fast/Slow and it decides speed of approaching of zoom position by adjusting speed of ZOOM MOTOR. B-6. ALARM Alarm can set up the 4 input line and 1 COMMON wiring on perception of the designed input change to SPEED DOME. Disable : Clear ALARM movement. ENABLE : Performance the designed movement about ALARM occurrence. 014 015

OSD Menu Setting IR OSD Menu Setting B-7. LANGUAGE This is for setting the language of OSD MENU and basically include ENGLISH / ITALIAN / POLISH. Change into Left / Right of Joystick. B-8. NEXT PAGE You can get into the Next Page by using Left / Right of Joystick. B-9. SAVE AND It can be used to save and taking out in the DOME SET, it wouldn't work out to save the data in case getting out of Menu using. B-10. It's used to get out of Menu not to save the set value. SAVE AND must surely be used in case of save. C. DOME SET #2 [NEXT PAGE] Password should be inputted 2 times using number, preset key. In case of same thing with PASSWORD input of 2 times, "CONFIRMED" will be showed up and back to the Menu after 4 second. Basic value of PASSWORD : 99 C-3. OSD DISPLAY Each part can be set up into ON/OFF, on On, remark operating sign in the designed place. OSD DISPLAY CAMERA ID ON PRESET ID ON SECTOR ID ON TOUR ID ON PATT ID ON SCAN ID ON COORDINATE ON [PREVIOUS PAGE] DOME SETUP SYSTEM LOCK OFF [PASS WORD] [OSD DISPLY] [SYSTEM STATUS] [INITIALIZATION] [PREVIOUS PAGE] C-1. SYSTEM LOCK Possibly set up the ON / OFF, in case of ON, when getting in the OSD MENU, set the function using password to prohibit from others except for manager. C-2. PASS WORD It is feasible to use that function when SYSTEM LOCK is ON, instruction is below. DOME SETUP ENTER PASSWORD BY ENTERING PRESET CODE! PASSWORD *** CONFIRM *** C-4. SYSTEM STATUS This is for checking the information of IR SPEED DOME, instruction is below. SYSTEM STATUS PROTOCOL PELCO-D, P BAUD RATE 2400 BPS FIRMWARE VER 1.00a UPGRADED DATE 09.02.11 CAMERA MODULE SCM3270 R/B UPGRADED DATE 01.K.10 [PREVIOUS PAGE] PROTOCOL : Communication Protocol information between Controller and SPEED DOME. RAUD RATE : Communication Speed information between Controller and SPEED DOME. FIRMWARE VER : Version information of Firmware used in product. UPGRADED DATE : Information on final writing day of the firmware. CAMERA MODULE : Module information used in product. R/B UPGRADED DATE : Information of final writing day on firmware of the REAR BOARD. 016 017

OSD Menu Setting IR OSD Menu Setting C-5. INITIALIZATION This is for removing the informations of PRESET/TOUR/SECTOR/PRIVACY/ PATTERN saved in Memory, on choice for LOAD OPTIMIZED DEFAULT, all of value should be initialized to FACTORY DEFAULT. INITIALIZATION [TOUR CLEAR] [PRESET CLEAR] [SECTOR CLEAR] [PRIVACY CLEAR] [PATTERN CLEAR] [LOAD OPTIMIZED DEFAULT] [PREVIOUS PAGE] CAMERA SET MENU #1 CAMERA SET SHUTTER FULL AUTO MIRROR OFF APERTURE 16 D ZOOM OFF WB MODE ATW MODE BLC OFF[BLC] D/N MODE AUTO MODE [SLOW] [NEXT PAGE] CAMERA SET MENU #2 [NEXT PAGE] C-6. PREVIOUS PAGE THis is for moving on former page. D. CAMERA SET You can set it up on module operating in the CAMERA SET MENU. MAIN MENU DOME SETUP CAMERA SET PRESET AUTO SCAN TOUR PRIVACY PATTERN ALARM SECTOR Possible to enter using Left/Right of Joystick after choose CAMERA SETUP from MAIN MENU OSD. CAMERA SET SENSE UP X2 AGC MODE MIDDLE SSNR MODE MIDDLE COLOR 050 DIS MODE OFF IRIS SET AUTO [PREVIOUS PAGE] D-1. SHUTTER This is menu for set up the Shutter Speed of Camera. The value for Default is FULL AUTO, and possible to change it using Left/ Right of Joystick - Change Procedure : FULL AUTO MANUAL A.FLICKER - FULL AUTO : Changing the Shutter Speed automatically according to lights. - A.FLICKER : Set FLICKER as ON - MANUAL : It can be changed by Focus Far Key of Controller, showing up mark if you press it. In this time, possible to set up from X512 (Digital Slow Shutter) to 1/120000 using Left/Right of Joystick and setting value would be saving vanishing if pressed Focus Far Key. 018 019

OSD Menu Setting IR OSD Menu Setting D-2. MIRROR Possible to set up ON/OFF, image should be left side to right. D-3. APERTURE Sharpness can be controlled. - The value for Default is 16, possible to adjust 00~31, higher the number, clear the Sharpness. D-4. D ZOOM Digital Zoom can be set ON/OFF. D-5. WB MODE Possible to set up the White Balance, number of Mode are 3 in total. - Default value is ATW, which can be changed into INDOOR/OUTDOOR/ATW MODE. D-6. BLC It can be set up into 3 Mode by Back Light Compensation. - Basically on OFF, possible to set up the ON/OFF using Left/Right of Joystick. - would be showed up on the left if pressed Focus Far Key on ON, and then possible to insert to the Menu of BLC/HLC/SSDR. D-6-1. BLC MODE (Back Light Compensation) D-6-2. HLC MODE (High Light Compensation) BLC SET BLC MODE HLC LEVEL SET HIGH MASK COLOR 07 LEVEL SET : Possible to set up into HIGH/LOW. MASK COLOR : Higher the number, closer to black and feasible to set up 01~16 D-6-3. SSDR MODE (Samsung Super Dynamic Range) BLC SET BLC MODE SSDR LEVEL SET WIDE MASK COLOR 008 BLC MODE LEVEL SET AREA SET BLC SET BLC HIGH LEFT / TOP RANGE SET : Possible to set up into WIDE/NARROW LEVEL SET : Setup 00~16 LEVEL SET : It can be set up into HIGH/MIDDLE/LOW AREA SET : This is for setting the area, sign would be showed up when getting in the BLC Menu. - LEFT/TOP : The sign of LEFT/TOP can be changed by Joystick. - RIGHT/BOTTOM : The size of RIGHT/BOTTOM can be changed by Joystick. D-7. D/N MODE Setting up the DAY&NIGHT. - It can be set up 3Mode of DAY/NIGHT/AUTO in total using Left/Right of Joystick, in case with IR_LED, should be on ON when NIGHT MODE, be Controlled LED brightness by ZOOM. - In case of AUTO, it would be changed automatically using amount of lights and No IR LED, possible to set up the changed speed [SLOW/FAST] using Focus Far Key. - In case with IR LED, possible to change it 0~10 stage using Focus Near Key. 020 021

OSD Menu Setting IR OSD Menu Setting D-8. SENSE UP You can set up the Digital Slow Shutter, not doing anything directly. In case on ON sense up, Shutter Speed should be adjusted according to amount of lights. Then Slow Shutter is not working that the section set to Sense up would be Limited. - Possible to set it up using Left/Right of Joystick, maximum is x2~x512 * SENSE UP is not applied in case controlling Shutter Speed with manual. D-9. AGC MODE : Auto Gain Control Possible to set up 4 mode of OFF/LOW/MIDDLE using Left/Right of Joystick. D-10. SSNR : Samsung Super Noise Reduction Possible to set up 4 mode of OFF/LOW/MIDDLE using Left/Right of Joystick. D-11. COLOR Set up the Color of display and control every 5 out of 0~100. Lower the number, closer to black and white, higher the number, color would be stronger. The value of Default is 50 D-12. DIS This is for Digital Image Stabilizer, control the ON/OFF using Joystick. D-13. IRIS SET Set up the Iris (AUTO,MANUAL) - AUTO : IRIS is operating automatically. - MANUAL : On Manual Mode, F1.6 would be signed and if you press Focus Far Key, should be showed up and then can be changed using Joystick Left/Right. If you press Focus Far Key after completing setting, should be disappeared and setting value would be saved. The Range for change is CLOSE, F1.6~F28 E. PRESET SET You can insert to PRESET menu using Left/Right of Joystick after choice PRESET SET. PRESET SET PRESET NO : 001 PRESET ID : PRESET001 PAN : 123.2 TILT : 89.2 FREEZE MODE FREEZE ALL SAVE E-1. PRESET NO. Possible to set up the number of PRESET to save using LEFT/RIGHT of Joystick. - PRESET NUMBER is impressed with 3 word - The number for setting of [1~64],[100~255] 165 in total can be picked out. - On control of LEFT/RIGHT of Joystick can be changed automatically, with this.[64 100],[100 64] - If you press the Focus Far Key, It could be moving to relevant preset in case of enrolled when Cursor locate on PRESET NO E-2. PRESET ID ID of PRESET can be enrolled by user randomly in range of 16 words. - Default is kind of ""PRESET***"".( * meaning is PRESET NUMBER) - Changing the words as LEFT/RIGHT of Joystick, and position can be changed by ZOOM IN/OUT. - End of Changing ID should be moved on OSD MENU of up or down by controlling TILT. In this time, in case of pressing the FOCUS FAR, getting in the PAN/TILT/ ZOOM setting mode and it would be changed original ID setting mode if pressed one more time. 022 023

OSD Menu Setting IR OSD Menu Setting E-3. PAN/TILT If you press the Focus Far Key after place Cursor to Menu, sign would be showed up on the left and can set up the position, zoom you want. And then get out of there pressing the Focus Far Key after completing setting. That time, should be taken out. E-4. FREEZE MODE On moving on relevant preset when Preset set, it can be set up whether display move to Freeze, on On, Freeze Preset can be vitalized. E-5. FREEZE ALL Set up the ON/OFF, on ON, Freeze Preset can be vitalized to all of Preset. E-6. SAVE It's used to save the value set after setting is completed and can be saved anything using Left/Right of Joystick F. AUTO SCAN You can get in the AUTO SCAN using Left/Right of Joystick after decision AUTO SCAN from Main Menu. AUTO SCAN SET START ANGLE : 250.5 35.0 END ANGLE : 320.0 35.0 DIRECTION : CW ENDLESS SPEED : 10º/S DWELL TIME : 01 SAVE AND F-1. START / END ANGLE Possible to set up the position of beginning and end of Auto Scan. - You can control the only position of PAN from each menu of START ANGLE/ END ANGLE in basic screen. - In case you change the position of TILT or ZOOM, it'd be possible only with status changed mode by pressing FOCUS FAR. (In this time, PAN/TILT/ZOOM Possible.) -The position of PAN should be decided into each position of START/END and position of TILT or ZOOM would be decided into last day controlled without relationship of START/END. (Control of TILT and ZOOM should be applied to same position of START/ END.) - The coordinate of PAN/TILT signed in START ANGLE would be marked into coordinate in case of entering MENU, when position of cursor moved on START/END ANGLE, it would be changed to current position.so there is no way to check the position saved. F-2. DIRECTION Feasible to set up the direction of rotation of PAN. - You can set it up into CW/CCW. F-3. ENDLESS On ON, Endless keeps rotating into direction set from DIRECTION regardless of position of START/END. F-4. SPEED You can set up the speed of revolution of PAN from 01º/S to 35º/S. Possibly input into Direct using [1-35]+Preset after place the Cursor on the SPEED Menu. F-5. DWELL TIME On OFF of ENDELSS, you can set up the time stopped when approaching each position of START/END. The value for setting is 1~99, input directly using [1-99]+Preset. F-6. SAVE AND It's used to save and take off the Menu after setting completed. F-7. It's used to take off the Menu not saving setting value. 024 025

OSD Menu Setting IR OSD Menu Setting G. TOUR You can use this function using Left/Right of Joystick after choice the TOUR in the Main Menu. TOUR SET TOUR NO. : 01 TOUR TITLE : TOUR01 TOUR STEP : 01 PRESET NO. : 001 DWELL TIME : 03 SPEED : 300º/S SAVE G-1. TOUR NO. This is for Menu for choice the GROUP NUMBER of TOUR that you'll set it up into GROUP out of 8 of TOUR. Possibly choice 1~8. G-2. TOUR TITLE ID for tour can be registered as option by user within range of 16words. - Default is for ""TOUR**"". (* is for TOUR NUMBER) - You can change the character with PAN LEFT/RIGHT and position with ZOOM IN/OUT. - For make ID changing over, move to OSD MENU by controlling TILT. G-3. TOUR STEP This is for turn of playback of PRESET you'll design the GROUP. Possibly it could be registered 60 in maximum and PRESET will working as turn. G-4. PRESET NO. This is for registration the PRESET to TOUR STEP. - Choose the PRESET number using LEFT/RIGHT of Joystick. - You can input it directly using [1..64],[100,255]+ Preset. - The color for PRESET should be changed in case that PRESET isregistered. G-5. DWELL TIME This is for setting the holding time after moving is finished to relevant PRESET. - The value for setting is 1~99, you can input it directly using [1-99]+Preset. G-6. SPEED Possible to set up the time moving to relevant PRESET. - The value for setting is 10º/S~400º/S, can input it directly using [1-40]+Preset. (On inserting Direct, you should input the value of shared into 10 from relevant Speed value.) F-3. TOUR STEP This is for turn of playback of PRESET you'll design the GROUP. Possibly it could be registered 60 in maximum and PRESET will working as turn. G-7. SAVE This is for saving the setting value, save it suing Left/Right of Joystick. If value saved, Cursor for TOUR STEP would be placed automatically and raising up 1 of TOUR STEP. G-5. It's used to take off the TOUR SET Menu. H. PRIVACY You can use this function using Left/Right of Joystick after choice PRIVACY in Main Menu. This is for MASKING in order to protect the private life on special position of security area. PRIVACY SET PRIVACY NUMBER : 01 DISPLAY ACTION : MOVE SAVE H-1. PRIVACY NUMBER You can set it up 8 in total, it should be used to choose the relevant number. H-2. DISPLAY You can set it up both ON/OFF, on ON, BLUE BOX of square would be indicated on center of screen. 026 027

OSD Menu Setting IR OSD Menu Setting H-3. ACTION This is for set up the position, size of PRIVACY MASK, you can control with 2 ADJUST MODE in order to set the MOVE MODE and size for set the position. - Possible for setting MOVE/ADJUST using Left/Right of Joystick in ACTION MENU.» MOVE : You can adjust the position of PAN/TILT/ZOOM and move as you want.» adjust : You can adjust the size of PRIVACY MASK. H-4. SAVE It's used to save the set value and if saved it, Cursor should be moved on to PRIVACY SET MENU automatically. H-5. It's used to take off the PRIVACY SET MENU. I. PATTERN You can get in using Left/Right of Joystick after decision the Pattern in Main Menu. PATTERN SET PATT NO. : 01 PATT TITLE : PATTERN01 DATA FILLL : 012% SAVE I-2. PATT TITLE On working PATTERN, the function for inputting the characters for title if showed up on the screen. - Default os for "PATTERN01 " - The changing of character can be set up using the Left/Right/Up or Zoom In/Out of joystick. I-3. DATA FILL This is for marking when saving or status of PATTERN DATA. - If you press the Focus Far Key, "DATA FILL" would be blinked and get started saving of Manual value. In this time, if data saved by 99%, Cursor could be placed on the save automatically after stop the operation. - Blinking of DATA FILL would be stopped and DATA saved on the right would be signed to "%" if you press the Focus Far Key after Manual adjustment is finished. I-4. SAVE This is for saving the data set and in case saving the value, Cursor would be moving on PATT NO and the value of NO grows up each 1. I-5. It is used to take off the PATTERN SET MENU. J. ALARM You can get the function in using Left/Right of Joystick after ALARM in Main Menu and it makes it operating special when it senses the changing the 4ports inside. I-1. PATT NO. This is for choice of number of pattern, and 8 in total you can register. ALARM SET ALARM NO. : 01 ALARM INPUT ALARM ACT : 001 AUX ACT : BLK SAVE J-1. ALARM NO. It can be chosen the ALARM number that you'll set. 028 029

OSD Menu Setting IR OSD Menu Setting J-2. ALARM INPUT Set up the sensing way of ALARM or Using ARARM. - [OFF/NO/NC] can be set up. - NO's meaning is Normal Open and handle the CLOSE to NORMAL of OPEN. - NC's meaning is Normal Close and handle the OPEN to NORMAL of CLOSE. - It should be controlled by using LEFT/RIGHT of Joystick. J-3. ALARM ACT This is for registration the operating when occur ALARM. - The number of registration for PRESET is [1..64, 100..200]/TOUR[01..08]/ PATTERN[01..08] - PRESET is marked with 3words and changed to ([001..064], [100..200]) automatically. - TOUR is marked with 3words of [P01...P08]. Each PATTERN is YOUR[1...8]. - PATTERN is marked with 3wordsof [T01...T08]. Each is TOUR[1..8]. - In case of PRESET, ACTION is over after completion of moving for PRESET position. - In case of TOUR/PATTERN, ACTION is over after completion each 1 time. J-4. AUX ACT On occurrence ALARM, it's function for controlling the outdoor PORT. - You can choice between BLK/AUX1/AUX2 - When setting to BLK, on occurrence the ALARM, There's no changing AUX terminal. - On setting AUX1, it should handle the terminal into on when occurrence ALARM. - On setting AUX2, it should handle the terminal into on when occurrence ALARM. - The holding time for ON of each AUX terminal is fasten 5sec. J-5. SAVE This is for saving the set value, NO is raised up 1, when Cursor places to ALARM NO. J-6. This is used to take off the ALARM MENU. K. SECTOR This is for sign the TITLE on the screen on sprecial section to get in using LEFT/ RIGHT of JOYSTICK after choose the SECTOR in the Main Menu. SECTOR SET SECTOR NO. : 01 SECTOR ID : SECTOR1 SECTOR START : 334.7-1.6 SECTPR EMD : 000.4 08.8 SAVE K-1. SECTOR NO. You can design the SECTOR 8 in total using Left/Right of Joystick. K-2. SECTOR ID This is for inputting words for TITLE and will be marked on the screen on SECTOR. -Default is "SECTOR1 ".( is blank) - You can set up the changing of character using Left/Right/Up/Down or Zoom in/out of Joystick. K-3. SECTOR START Design the START position of SECTOR section to work. - Enter it as designed MODE by pressing FOCUS FAR. - Move on position as you want to go using PAN/TILT/ZOOM. - The designed MODE should be over by pressing the FOCUS FAR Key after design of position is completed. K-4. SECTOR END Design the END position of SECTOR section. - Enter the place as designed MODE by pressing the FOCUS FAR key. - Move on the position as you want to go using the PAN/TIRL/ZOOM. K-5. SAVE It's used to save the set SECTOR value. K-6. It's used to take off the SECTOR SET Menu. 030 031

DIP Switch Setting DIP Switch Setting A. ID SETTING The camera has camera ID to be controlled by Controller or DVR. After opening, set ID using DIP SW1. Factory default : Camera ID = 1 ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 1 ON OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 9 ON OFF OFF ON OFF OFF OFF OFF 10 OFF ON OFF ON OFF OFF OFF OFF 11 ON ON OFF ON OFF OFF OFF OFF 12 OFF OFF ON ON OFF OFF OFF OFF 13 ON OFF ON ON OFF OFF OFF OFF 14 OFF ON ON ON OFF OFF OFF OFF 15 ON ON ON ON OFF OFF OFF OFF 16 OFF OFF OFF OFF ON OFF OFF OFF 17 ON OFF OFF OFF ON OFF OFF OFF 18 OFF ON OFF OFF ON OFF OFF OFF 19 ON ON OFF OFF ON OFF OFF OFF 20 OFF OFF ON OFF ON OFF OFF OFF 21 ON OFF ON OFF ON OFF OFF OFF 22 OFF ON ON OFF ON OFF OFF OFF 23 ON ON ON OFF ON OFF OFF OFF 24 OFF OFF OFF ON ON OFF OFF OFF 25 ON OFF OFF ON ON OFF OFF OFF 26 OFF ON OFF ON ON OFF OFF OFF 27 ON ON OFF ON ON OFF OFF OFF 28 OFF OFF ON ON ON OFF OFF OFF 29 ON OFF ON ON ON OFF OFF OFF 30 OFF ON ON ON ON OFF OFF OFF 31 ON ON ON ON ON OFF OFF OFF 32 OFF OFF OFF OFF OFF ON OFF OFF 33 ON OFF OFF OFF OFF ON OFF OFF 34 OFF ON OFF OFF OFF ON OFF OFF ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 35 ON ON OFF OFF OFF ON OFF OFF 36 OFF OFF ON OFF OFF ON OFF OFF 37 ON OFF ON OFF OFF ON OFF OFF 38 OFF ON ON OFF OFF ON OFF OFF 39 ON ON ON OFF OFF ON OFF OFF 40 OFF OFF OFF ON OFF ON OFF OFF 41 ON OFF OFF ON OFF ON OFF OFF 42 OFF ON OFF ON OFF ON OFF OFF 43 ON ON OFF ON OFF ON OFF OFF 44 OFF OFF ON ON OFF ON OFF OFF 45 ON OFF ON ON OFF ON OFF OFF 46 OFF ON ON ON OFF ON OFF OFF 47 ON ON ON ON OFF ON OFF OFF 48 OFF OFF OFF OFF ON ON OFF OFF 49 ON OFF OFF OFF ON ON OFF OFF 50 OFF ON OFF OFF ON ON OFF OFF 51 ON ON OFF OFF ON ON OFF OFF 52 OFF OFF ON OFF ON ON OFF OFF 53 ON OFF ON OFF ON ON OFF OFF 54 OFF ON ON OFF ON ON OFF OFF 55 ON ON ON OFF ON ON OFF OFF 56 OFF OFF OFF ON ON ON OFF OFF 57 ON OFF OFF ON ON ON OFF OFF 58 OFF ON OFF ON ON ON OFF OFF 59 ON ON OFF ON ON ON OFF OFF 60 OFF OFF ON ON ON ON OFF OFF 61 ON OFF ON ON ON ON OFF OFF 62 OFF ON ON ON ON ON OFF OFF 63 ON ON ON ON ON ON OFF OFF 64 OFF OFF OFF OFF OFF OFF ON OFF 65 ON OFF OFF OFF OFF OFF ON OFF 66 OFF ON OFF OFF OFF OFF ON OFF 67 ON ON OFF OFF OFF OFF ON OFF 68 OFF OFF ON OFF OFF OFF ON OFF 69 ON OFF ON OFF OFF OFF ON OFF 70 OFF ON ON OFF OFF OFF ON OFF 71 ON ON ON OFF OFF OFF ON OFF 72 OFF OFF OFF ON OFF OFF ON OFF 73 ON OFF OFF ON OFF OFF ON OFF 74 OFF ON OFF ON OFF OFF ON OFF 75 ON ON OFF ON OFF OFF ON OFF 76 OFF OFF ON ON OFF OFF ON OFF 77 ON OFF ON ON OFF OFF ON OFF 78 OFF ON ON ON OFF OFF ON OFF 79 ON ON ON ON OFF OFF ON OFF 80 OFF OFF OFF OFF ON OFF ON OFF 032 033

DIP Switch Setting DIP Switch Setting ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 81 ON OFF OFF OFF ON OFF ON OFF 82 OFF ON OFF OFF ON OFF ON OFF 83 ON ON OFF OFF ON OFF ON OFF 84 OFF OFF ON OFF ON OFF ON OFF 85 ON OFF ON OFF ON OFF ON OFF 86 OFF ON ON OFF ON OFF ON OFF 87 ON ON ON OFF ON OFF ON OFF 88 OFF OFF OFF ON ON OFF ON OFF 89 ON OFF OFF ON ON OFF ON OFF 90 OFF ON OFF ON ON OFF ON OFF 91 ON ON OFF ON ON OFF ON OFF 92 OFF OFF ON ON ON OFF ON OFF 93 ON OFF ON ON ON OFF ON OFF 94 OFF ON ON ON ON OFF ON OFF 95 ON ON ON ON ON OFF ON OFF 96 OFF OFF OFF OFF OFF ON ON OFF 97 ON OFF OFF OFF OFF ON ON OFF 98 OFF ON OFF OFF OFF ON ON OFF 99 ON ON OFF OFF OFF ON ON OFF 100 OFF OFF ON OFF OFF ON ON OFF 101 ON OFF ON OFF OFF ON ON OFF 102 OFF ON ON OFF OFF ON ON OFF 103 ON ON ON OFF OFF ON ON OFF 104 OFF OFF OFF ON OFF ON ON OFF 105 ON OFF OFF ON OFF ON ON OFF 106 OFF ON OFF ON OFF ON ON OFF 107 ON ON OFF ON OFF ON ON OFF 108 OFF OFF ON ON OFF ON ON OFF 109 ON OFF ON ON OFF ON ON OFF 110 OFF ON ON ON OFF ON ON OFF 111 ON ON ON ON OFF ON ON OFF 112 OFF OFF OFF OFF ON ON ON OFF 113 ON OFF OFF OFF ON ON ON OFF 114 OFF ON OFF OFF ON ON ON OFF 115 ON ON OFF OFF ON ON ON OFF 116 OFF OFF ON OFF ON ON ON OFF 117 ON OFF ON OFF ON ON ON OFF 118 OFF ON ON OFF ON ON ON OFF 119 ON ON ON OFF ON ON ON OFF 120 OFF OFF OFF ON ON ON ON OFF 121 ON OFF OFF ON ON ON ON OFF 122 OFF ON OFF ON ON ON ON OFF 123 ON ON OFF ON ON ON ON OFF 124 OFF OFF ON ON ON ON ON OFF 125 ON OFF ON ON ON ON ON OFF 126 OFF ON ON ON ON ON ON OFF ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 127 ON ON ON ON ON ON ON OFF 128 OFF OFF OFF OFF OFF OFF OFF ON 129 ON OFF OFF OFF OFF OFF OFF ON 130 OFF ON OFF OFF OFF OFF OFF ON 131 ON ON OFF OFF OFF OFF OFF ON 132 OFF OFF ON OFF OFF OFF OFF ON 133 ON OFF ON OFF OFF OFF OFF ON 134 OFF ON ON OFF OFF OFF OFF ON 135 ON ON ON OFF OFF OFF OFF ON 136 OFF OFF OFF ON OFF OFF OFF ON 137 ON OFF OFF ON OFF OFF OFF ON 138 OFF ON OFF ON OFF OFF OFF ON 139 ON ON OFF ON OFF OFF OFF ON 140 OFF OFF ON ON OFF OFF OFF ON 141 ON OFF ON ON OFF OFF OFF ON 142 OFF ON ON ON OFF OFF OFF ON 143 ON ON ON ON OFF OFF OFF ON 144 OFF OFF OFF OFF ON OFF OFF ON 145 ON OFF OFF OFF ON OFF OFF ON 146 OFF ON OFF OFF ON OFF OFF ON 147 ON ON OFF OFF ON OFF OFF ON 148 OFF OFF ON OFF ON OFF OFF ON 149 ON OFF ON OFF ON OFF OFF ON 150 OFF ON ON OFF ON OFF OFF ON 151 ON ON ON OFF ON OFF OFF ON 152 OFF OFF OFF ON ON OFF OFF ON 153 ON OFF OFF ON ON OFF OFF ON 154 OFF ON OFF ON ON OFF OFF ON 155 ON ON OFF ON ON OFF OFF ON 156 OFF OFF ON ON ON OFF OFF ON 157 ON OFF ON ON ON OFF OFF ON 158 OFF ON ON ON ON OFF OFF ON 159 ON ON ON ON ON OFF OFF ON 160 OFF OFF OFF OFF OFF ON OFF ON 161 ON OFF OFF OFF OFF ON OFF ON 162 OFF ON OFF OFF OFF ON OFF ON 163 ON ON OFF OFF OFF ON OFF ON 164 OFF OFF ON OFF OFF ON OFF ON 165 ON OFF ON OFF OFF ON OFF ON 166 OFF ON ON OFF OFF ON OFF ON 167 ON ON ON OFF OFF ON OFF ON 168 OFF OFF OFF ON OFF ON OFF ON 169 ON OFF OFF ON OFF ON OFF ON 170 OFF ON OFF ON OFF ON OFF ON 171 ON ON OFF ON OFF ON OFF ON 172 OFF OFF ON ON OFF ON OFF ON 034 035

DIP Switch Setting DIP Switch Setting ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 173 ON OFF ON ON OFF ON OFF ON 174 OFF ON ON ON OFF ON OFF ON 175 ON ON ON ON OFF ON OFF ON 176 OFF OFF OFF OFF ON ON OFF ON 177 ON OFF OFF OFF ON ON OFF ON 178 OFF ON OFF OFF ON ON OFF ON 179 ON ON OFF OFF ON ON OFF ON 180 OFF OFF ON OFF ON ON OFF ON 181 ON OFF ON OFF ON ON OFF ON 182 OFF ON ON OFF ON ON OFF ON 183 ON ON ON OFF ON ON OFF ON 184 OFF OFF OFF ON ON ON OFF ON 185 ON OFF OFF ON ON ON OFF ON 186 OFF ON OFF ON ON ON OFF ON 187 ON ON OFF ON ON ON OFF ON 188 OFF OFF ON ON ON ON OFF ON 189 ON OFF ON ON ON ON OFF ON 190 OFF ON ON ON ON ON OFF ON 191 ON ON ON ON ON ON OFF ON 192 OFF OFF OFF OFF OFF OFF ON ON 193 ON OFF OFF OFF OFF OFF ON ON 194 OFF ON OFF OFF OFF OFF ON ON 195 ON ON OFF OFF OFF OFF ON ON 196 OFF OFF ON OFF OFF OFF ON ON 197 ON OFF ON OFF OFF OFF ON ON 198 OFF ON ON OFF OFF OFF ON ON 199 ON ON ON OFF OFF OFF ON ON 200 OFF OFF OFF ON OFF OFF ON ON 201 ON OFF OFF ON OFF OFF ON ON 202 OFF ON OFF ON OFF OFF ON ON 203 ON ON OFF ON OFF OFF ON ON 204 OFF OFF ON ON OFF OFF ON ON 205 ON OFF ON ON OFF OFF ON ON 206 OFF ON ON ON OFF OFF ON ON 207 ON ON ON ON OFF OFF ON ON 208 OFF OFF OFF OFF ON OFF ON ON 209 ON OFF OFF OFF ON OFF ON ON 210 OFF ON OFF OFF ON OFF ON ON 211 ON ON OFF OFF ON OFF ON ON 212 OFF OFF ON OFF ON OFF ON ON 213 ON OFF ON OFF ON OFF ON ON 214 OFF ON ON OFF ON OFF ON ON 215 ON ON ON OFF ON OFF ON ON 216 OFF OFF OFF ON ON OFF ON ON 217 ON OFF OFF ON ON OFF ON ON 218 OFF ON OFF ON ON OFF ON ON ID SW1-#1 SW1-#2 SW1-#3 SW1-#4 SW1-#5 SW1-#6 SW1-#7 SW1-#8 219 ON ON OFF ON ON OFF ON ON 220 OFF OFF ON ON ON OFF ON ON 221 ON OFF ON ON ON OFF ON ON 222 OFF ON ON ON ON OFF ON ON 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF OFF OFF ON ON ON 228 OFF OFF ON OFF OFF ON ON ON 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON ON OFF OFF ON ON ON 231 ON ON ON OFF OFF ON ON ON 232 OFF OFF OFF ON OFF ON ON ON 233 ON OFF OFF ON OFF ON ON ON 234 OFF ON OFF ON OFF ON ON ON 235 ON ON OFF ON OFF ON ON ON 236 OFF OFF ON ON OFF ON ON ON 237 ON OFF ON ON OFF ON ON ON 238 OFF ON ON ON OFF ON ON ON 239 ON ON ON ON OFF ON ON ON 240 OFF OFF OFF OFF ON ON ON ON 241 ON OFF OFF OFF ON ON ON ON 242 OFF ON OFF OFF ON ON ON ON 243 ON ON OFF OFF ON ON ON ON 244 OFF OFF ON OFF ON ON ON ON 245 ON OFF ON OFF ON ON ON ON 246 OFF ON ON OFF ON ON ON ON 247 ON ON ON OFF ON ON ON ON 248 OFF OFF OFF ON ON ON ON ON 249 ON OFF OFF ON ON ON ON ON 250 OFF ON OFF ON ON ON ON ON 251 ON ON OFF ON ON ON ON ON 252 OFF OFF ON ON ON ON ON ON 253 ON OFF ON ON ON ON ON ON 254 OFF ON ON ON ON ON ON ON 255 ON ON ON ON ON ON ON ON 036 037

DIP Switch Setting Trouble Shooting B. 485 TERMINATION If you have trouble operating in your camera, refer to the following. The 1st of DIP SW2 is used for 100Ω termination. Set ON DIP SW2-1st of only the last looped camera from the controller. Even in case of only one camera, set ON DIP SW2-1st of the camera. NO OPERATING Check if the power supply is AC24V Check if RS-485 communication cable is connected correctly. Check camera ID setting. Check the termination. CAM 1 CAM 2C AM n-1 CAM n TERMINATION SW1-ON NO PICTURE Check if all the cables are connected correctly. Check the monitor is adjusted correctly. Check if video signal line is cut. DARK SCREEN Adjust the monitor status. ADNORMAL CAMERA OPERATION STATUS Check if the voltage level is out of the specification. Check the termination. C. FUNCTION DIP S/W NO. DEFINITION DETAIL 1 Binary Number Protocol #1 321 : Dip S/W Number 000 : PELCO-D/P 001 : VICON 2 Binary Number Protocol #2 010 : SAMSUNG 011 : SAE 100 : x 101 : x 3 Binary Number Protocol #3 110 : x 111 : x SCREEN NOT CLEAR Check if there is dust on a lens. Adjust the monitor status. if excessive light is seen on a screen, change the camera angle or location. Adjust the lens focus again. 4 Binary Number Baud rate #1 54 : Dip S/W Number 00 : x 01 : 2400 bps 5 Binary Number Baud rate #2 10 : 4800 bps 11 : 9600 bps 6 Reserved Reserved 7 Reserved Reserved 8 Termination RS-485 terminating resistance can be used by user. ON : Availble OFF : Not Available. 038 039

Specification (Without IR) Specification (Without IR) Model TNS-1821 / 1822 TNS-2821 / 2822 TNS-3621 / 3622 PAN/TILT Pan Rotation Angle 360º Endless Pan Speed Manual : 0.5º ~ 200º /sec (64step) / Preset : Max 400º/sec Tilt Rotation Angle -2º ~ 90º Tilt Speed Manual : 0.5º ~ 150º/sec (64step) / Preset : Max 350º/sec System Accuracy 0.009º FUNCTION Preset 220 positions with 16-character label available for each position with different speed steps and Freeze Preset available Group Tour Max. 8 Programmable group tours (each one consisting of up to 60 preset steps with different steps) Auto Scan Programable Auto scan Pattern 8 Programmable Patterns (total 480 seconds) Sector 8 selectable Sectors with 16 characters Home Position (Recover) Yes (Preset / Tour / Pattern / Scan) Password Protection Yes Privacy Zone 24 24 24 Image Stabilizer N/A Yes Yes Recover Origin N/A N/A N/A WDR Option Option Option SSNR N/A N/A N/A SSDR N/A N/A N/A DNR Yes Yes Yes DSS (Sens Up) BLC HLC N/A N/A N/A Day & Night AUTO / DAY / NIGHT Flickerless Alarm Input 4 alarms(with various programmable states) Alarm Actions Activate preset, Group Tour, Pattern or Relay output per alarm input Aux Output 2 Relay Auto Flip OSD Menu Yes Communication RS-485 Protocol Multiple Protocols IR Mode N/A POWER Power Consumption AC24V 1A 24W Max (With Heater : AC24V 1.2A 28.8W Max) Power Supply AC24V 50/60Hz 1.2A (With Heater : AC24V 50/60Hz 1.5A) OTHERS Construction Aluminum die casting Motor Type Stepping motor (2 Phase) Micro Steps 1/16 Micro Step Storage Temperature -20ºC ~ 60ºC (-4ºF ~ 140ºF) Operating Temperature -10ºC ~ 50ºC (14ºF ~ 122ºF) (With Heater : -40ºC ~ 50ºC) Certifications CE, FCC, IP66 CAMERA MODULE Image Sensor 1/4" Sony Exview HAD CCD Total Image Pixels NTSC : 811(H) x 508(V) 410K Horizontal Resolution PAL : 795(H) x 596(V) 470K 550TVL Lens 18x F=1.4~3.0, f=4.1~73.8mm 28x F=1.35~3.7, f=3.5~98.0mm 36x F=1.6~4.5, f=3.4~122.4mm (Digital : 12X / Total : 216X) (Digital : 12X / Total : 324X) (Digital : 12X / Total : 432X) WDR Color : 0.7Lux(1/60:NTSC / 1/50:PAL) WDR Color : 0.65Lux(1/60:NTSC / 1/50:PAL) Min. Illumination B/W : 0.01Lux(1/4:NT / 1/3:PAL) B/W : 0.005Lux(1/4:NT / 1/3:PAL) 1.4Lux(Color : 50IRE) Non WDR Non WDR 0.01Lux(B/W : ICR ON) Color : 0.4Lux(1/60:NTSC / 1/50:PAL) B/W : 0.4Lux(1/60:NTSC / 1/50:PAL) Color : 0.25Lux(1/60:NTSC / 1/50:PAL) B/W : 0.0015 lx (1/4:NT / 1/3:PAL) Luminance S/N Ratio More than 50dB Video Output Composite video output 75Ω Terminated Model TNS-2721 / 2722 TNS-3321 / 3322 TNS-3721 / 3722 TNS-E3621 / E3622 PAN/TILT Pan Rotation Angle 360º Endless Pan Speed Manual : 0.5º ~ 200º /sec (64step) / Preset : Max 400º/sec Tilt Rotation Angle -2º ~ 90º Tilt Speed Manual : 0.5º ~ 150º/sec (64step) / Preset : Max 350º/sec System Accuracy 0.009º FUNCTION Preset 220 positions with 16-character label available for each position with different speed steps and Freeze Preset available Group Tour Max. 8 Programmable group tours (each one consisting of up to 60 preset steps with different steps) Auto Scan Programable Auto scan Pattern 8 Programmable Patterns (total 480 seconds) Sector 8 selectable Sectors with 16 characters Home Position (Recover) Yes (Preset / Tour / Pattern / Scan) Password Protection Yes Privacy Zone 8 8 8 16 Image Stabilizer Yes Yes Yes Yes Recover Origin N/A N/A N/A N/A WDR Option Option Option Yes SSNR Yes Yes Yes N/A SSDR Option Option Option N/A DNR N/A N/A N/A Yes DSS (Sens Up) BLC HLC N/A Day & Night AUTO / DAY / NIGHT Flickerless Alarm Input 4 alarms(with various programmable states) Alarm Actions Activate preset, Group Tour, Pattern or Relay output per alarm input Aux Output 2 Relay Auto Flip OSD Menu Yes Communication RS-485 Protocol Multiple Protocols IR Mode N/A POWER Power Consumption AC24V 1A 24W Max (With Heater : AC24V 1.2A 28.8W Max) Power Supply AC24V 50/60Hz 1.2A (With Heater : AC24V 50/60Hz 1.5A) OTHERS Construction Aluminum die casting Motor Type Stepping motor (2 Phase) Micro Steps 1/16 Micro Step Storage Temperature -20ºC ~ 60ºC (-4ºF ~ 140ºF) Operating Temperature -10ºC ~ 50ºC (14ºF ~ 122ºF) (With Heater : -40ºC ~ 50ºC) Certifications CE, FCC, IP66 CAMERA MODULE Image Sensor 1/4" Interline Transfer CCD 1/4" Sony Super HAD II CCD Total Image Pixels NTSC : 811(H) x 508(V) 410K NTSC : 1028(H) x 508(V) 410K Horizontal Resolution PAL : 795(H) x 596(V) 470K 600TVL PAL : 1028(H) x 596(V) 470K 650TVL Lens 27x F=1.4~2.8, f=3.5~95.0mm 33x F=1.6~3.5, f=3.5~116.5mm 37x F=1.6~3.9, f=3.5~129.5mm 36x F=1.6~4.5, f=3.4~122.4mm (Digital : 12X / Total :432X) (Digital : 16X / Total :528X) (Digital : 16X / Total :592X) (Digital : 32X / Total :1152X) Min. Illumination Luminance S/N Ratio Video Output 0.2Lux(Color : 50IRE) 0.02Lux(B/W : ICR ON) 0.2Lux(Color : 50IRE) 0.02Lux(B/W : ICR ON) 0.2Lux(Color : 50IRE) 0.02Lux(B/W : ICR ON) More than 50dB Composite video output 75Ω Terminated 0.5Lux(Color : 50IRE) 0.0004Lux(B/W : ICR ON) 040 041

Specification (With IR) Specification (With IR) Model TNS-IR-1821 / 1822 TNS-IR-2821 / 2822 TNS-IR-3621 / 3622 PAN/TILT Pan Rotation Angle 360º Endless Pan Speed Manual : 0.5º ~ 200º /sec (64step) / Preset : Max 400º/sec Tilt Rotation Angle -2º ~ 90º Tilt Speed Manual : 0.5º ~ 150º/sec (64step) / Preset : Max 350º/sec System Accuracy 0.009º FUNCTION Preset 220 positions with 16-character label available for each position with different speed steps and Freeze Preset available Group Tour Max. 8 Programmable group tours (each one consisting of up to 60 preset steps with different steps) Auto Scan Programable Auto scan Pattern 8 Programmable Patterns (total 480 seconds) Sector 8 selectable Sectors with 16 characters Home Position (Recover) Yes(Preset / Tour / Pattern / Scan) Password Protection Yes Privacy Zone 24 24 24 Image Stabilizer N/A Yes Yes Recover Origin N/A N/A N/A WDR Option Option Option SSNR N/A N/A N/A SSDR N/A N/A N/A DNR Yes Yes Yes DSS (Sens Up) BLC HLC N/A N/A N/A Day & Night AUTO / DAY / NIGHT Flickerless Alarm Input 4 alarms(with various programmable states) Alarm Actions Activate preset, Group Tour, Pattern or Relay output per alarm input Aux Output 2 Relay Auto Flip OSD Menu Yes Communication RS-485 Protocol Multiple Protocols IR Mode Visual Distance : 30m POWER Power Consumption AC24V 1.5A 36W Max Power Supply AC24V 50/60Hz 2A OTHERS Construction Aluminum die casting Motor Type Stepping motor (2 Phase) Micro Steps 1/16 Micro Step Storage Temperature -20ºC ~ 60ºC (-4ºF ~ 140ºF) Operating Temperature -10ºC ~ 50ºC (14ºF ~ 122ºF) Certifications CE, FCC, IP66 CAMERA MODULE Image Sensor 1/4" Sony Exview HAD CCD Total Image Pixels NTSC : 811(H) x 508(V) 410K Horizontal Resolution PAL : 795(H) x 596(V) 470K 550TVL Lens 18x F=1.4~3.0, f=4.1~73.8mm 28x F=1.35~3.7, f=3.5~98.0mm 36x F=1.6~4.5, f=3.4~122.4mm (Digital : 12X / Total : 216X) (Digital : 12X / Total : 324X) (Digital : 12X / Total : 432X) WDR Color : 0.7Lux(1/60:NTSC / 1/50:PAL) WDR Color : 0.65Lux(1/60:NTSC / 1/50:PAL) Min. Illumination B/W : 0.01Lux(1/4:NT / 1/3:PAL) B/W : 0.005Lux(1/4:NT / 1/3:PAL) 1.4Lux(Color : 50IRE) Non WDR Non WDR 0.01Lux(B/W : ICR ON) Color : 0.4Lux(1/60:NTSC / 1/50:PAL) B/W : 0.4Lux(1/60:NTSC / 1/50:PAL) Color : 0.25Lux(1/60:NTSC / 1/50:PAL) B/W : 0.0015 lx (1/4:NT / 1/3:PAL) Luminance S/N Ratio More than 50dB Video Output Composite video output 75Ω Terminated Model TNS-IR-2721 / 2722 TNS-IR-3321 / 3322 TNS-IR-3721 / 3722 TNS-IR-E3621 / E3622 PAN/TILT Pan Rotation Angle 360º Endless Pan Speed Manual : 0.5º ~ 200º /sec (64step) / Preset : Max 400º/sec Tilt Rotation Angle -2º ~ 90º Tilt Speed Manual : 0.5º ~ 150º/sec (64step) / Preset : Max 350º/sec System Accuracy 0.009º FUNCTION Preset 220 positions with 16-character label available for each position with different speed steps and Freeze Preset available Group Tour Max. 8 Programmable group tours (each one consisting of up to 60 preset steps with different steps) Auto Scan Programable Auto scan Pattern 8 Programmable Patterns (total 480 seconds) Sector 8 selectable Sectors with 16 characters Home Position (Recover) Yes(Preset / Tour / Pattern / Scan) Password Protection Yes Privacy Zone 8 8 8 16 Image Stabilizer Yes Yes Yes Yes Recover Origin N/A N/A N/A N/A WDR Option Option Option Yes SSNR Yes Yes Yes N/A SSDR Option Option Option N/A DNR N/A N/A N/A Yes DSS (Sens Up) BLC HLC N/A Day & Night AUTO / DAY / NIGHT Flickerless Alarm Input 4 alarms(with various programmable states) Alarm Actions Activate preset, Group Tour, Pattern or Relay output per alarm input Aux Output 2 Relay Auto Flip OSD Menu Yes Communication RS-485 Protocol Multiple Protocols IR Mode Visual Distance : 30m POWER Power Consumption AC24V 1.5A 36W Max Power Supply AC24V 50/60Hz 2A OTHERS Construction Aluminum die casting Motor Type Stepping motor (2 Phase) Micro Steps 1/16 Micro Step Storage Temperature -20ºC ~ 60ºC (-4ºF ~ 140ºF) Operating Temperature -10ºC ~ 50ºC (14ºF ~ 122ºF) Certifications CE, FCC, IP66 CAMERA MODULE Image Sensor 1/4" Interline Transfer CCD 1/4" Sony Super HAD II CCD Total Image Pixels NTSC : 811(H) x 508(V) 410K NTSC : 1028(H) x 508(V) 410K Horizontal Resolution PAL : 795(H) x 596(V) 470K 600TVL PAL : 1028(H) x 596(V) 470K 650TVL Lens 27x F=1.4~2.8, f=3.5~95.0mm 33x F=1.6~3.5, f=3.5~116.5mm 37x F=1.6~3.9, f=3.5~129.5mm 36x F=1.6~4.5, f=3.4~122.4mm (Digital : 12X / Total :432X) (Digital : 16X / Total :528X) (Digital : 16X / Total :592X) (Digital : 32X / Total :1152X) Min. Illumination Luminance S/N Ratio Video Output 0.2Lux(Color : 50IRE) 0.02Lux(B/W : ICR ON) 0.2Lux(Color : 50IRE) 0.02Lux(B/W : ICR ON) 0.2Lux(Color : 50IRE) 0.02Lux(B/W : ICR ON) More than 50dB Composite video output 75Ω Terminated 0.5Lux(Color : 50IRE) 0.0004Lux(B/W : ICR ON) 042 043