KTD30 Digital Insulation and Continuity Tester

Similar documents
KTD30 Digital Insulation and Continuity Tester. User Manual. kewtechcorp.com

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

1.Safe testing IMPORTANT:

Digital/Analog Megohmmeter Model 1026

MIT300 Series Insulation and Continuity Testers

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL

User Guide. Model Insulation Tester / Megohmmeter

COMPONENT-TESTER INSTRUCTION MANUAL

Distributor. Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA KEWTECH

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

KEWTECH. KT56 digital multi function tester. Instruction manual

Digital/Analog Megohmmeter Model 1026 USER MANUAL

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

User Guide. Model Insulation Tester / Megohmmeter

User Guide. Model Insulation Tester / Megohmmeter. Introduction

BM kv Digital Insulation Tester USER MANUAL

OPERATING INSTRUCTION

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

MIT300 Series Insulation and Continuity testers USER MANUAL

RISH Insu 10 Analog-Digital Insulation Tester

Model Insulation Tester / Megohmmeter. User Manual

MIT300 Series Insulation and Continuity testers USER MANUAL

PAT120, PAT150 and PAT150R

KMP Insulation-Continuity Tester. Users Manual

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

SafetyPAT Plus A B P/N:

Attention ETCR8600 Leakage Protector Tester To read this user manual carefully. To comply with the operating cautions presented in this manual.

OPERATING INSTRUCTION

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

Table of Contents Title Page No.

Users Manual. MegOhmMeter

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

User's Manual Digital High Voltage Insulation Tester Model

Instruction Manual for model CB1 Check Box

USER MANUAL. Insulation Tester + DMM. Model MG320

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

MIT300 Series Insulation and Continuity Testers USER MANUAL

Dawson DDM190D. Digital Multimeter User s Manual

Autoranging Industrial Multimeter

Digital Insulation Resistance Testers. you can depend on

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

Component Test Fixture

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Digital Multimeter AHMAD FOUAD ALWAN

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Reference Manual Handheld Pressure Calibrator JOFRA HPC400

True RMS Autoranging Multimeter

DIGITAL RCD(ELCB) TESTER

Autoranging Multimeter

with lcd display 12-42v

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso

SCALIX MULTIPURPOSE SCALES SCALIX COMPACT SCALE FKS-600 FKS-6000 INSTRUCTION MANUAL

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

WENS30C Loop Calibrator

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

MEGGER BM15/MJ15 MEGGER. Insulation Testers. User Guide. MeterCenter (800)

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Model UT601: OPERATING MANUAL

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

MODEL No s: PP3, PP3K

Reading on meter (set to ohms) when the leads are NOT touching

HD110C Heavy-Duty Digital Multimeter

Advanced Test Equipment Rentals ATEC (2832)

Digital Multimeter User's Manual

Model ½ Digit Multimeter

707Ex. Users Manual. ma Calibrator

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

DIGITAL MULTIMETER INSTRUCTION MANUAL

Chek-A-Cell TM TestEquipmentDepot.com. Instruction Manual Rev A 8/12

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK.

ATD-5570 DELUXE AUTOMOTIVE METER

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Temperature Calibrator

MIT515, MIT525, MIT1025, MIT1525

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

DIGITAL INSULATION TESTER RS-5500/5505 INSTRUCTION MANUAL

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

1. INTRODUCTION AND SYSTEM DESCRIPTION SPECIFICATIONS... 5

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Model Battery Powered Milliohm Meter

INSTRUCTION MANUAL DM5B Fax: (503)

MANUAL PCE-IT111

Safety design conforming to the following provisions

MILWAUKEE ELECTRIC TOOL CORPORATION TEST & MEASUREMENT PRODUCT. REPAIR SERVICE INSTRUCTIONS CALIBRATION Milliamp Clamp Meter

Atlas ESR. User Guide. Capacitance and Equivalent Series Resistance Meter. Model ESR60 (Enhanced)

Transcription:

KTD30 Digital Insulation and Continuity Tester User Manual www.kewtechcorp.com 1

The Kewtech KTD30 Loop Impedence Tester is designed for use by suitably qualified personnel familiar with electrical supply systems. Operation a Detailed View of the KTD30 Caution Before using your KTD30 please read these instructions; in particular note the safety issues that follow: Your tester is for use on dead circuits only. Although your Kewtech instrument is fully protected against accidental connection to a live circuit it is essential to check the circuit is dead before working on it. 2 3 Your tester is equipped with a very convenient auto test (hands free) feature but do not touch the lead tips when using this feature. 1 Live Circuit There may be capacitance on the circuit being tested (a longer than normal test time will indicate this condition). Your tester will automatically discharge this but do not disconnect the test leads until this auto discharge has completed. On the subject of test leads, always check for damaged leads or croc clips - Kewtech replacement lead sets are inexpensive and easy to obtain. The continuity circuit is fuse protected against accidental connection to mains (unlikely as there will be a warning to indicate a live circuit) - if this fuse does blow replace it with the correct type F 500mA fast blow ceramic. It is located inside the battery compartment. 2 LCD Display 3 Power ON/OFF (including Intelligent Auto Power Off) BS EN 61010-1 Batteries 6 Continuity Test Because of storage issues your tester is not supplied with batteries. ALWAYS REMOVE THE TEST LEADS BEFORE REPLACING BATTERIES. Just 4 AA cells are required (alkaline recommended). The battery compartment is at the the back of the instrument, remove the screw (do not lose it) slide the battery cover off and carefully insert the batteries observing correct polarity. Replace cover and fix screw back in. 4 good quality AA alkaline cells should give 5000 tests at DC. Note: Access to the protective fuse is also gained through the battery compartment. Always replace with the correct type F 500mA Fast Blow Ceramic. 4 Insulation Test 5 Insulation Test Voltage 250V 1000V 7 Continuity Test Lead Null 8 Briefly Pust to Test (Instant) plus Push and Hold for 2 seconds for Auto Test (Hands Free)

1 LIVE CIRCUIT WARNING If this is alight DO NOT PROCEED you are connected to a live circuit. This useful indicator will also show if a (capacitive) circuit under test is fully discharged before disconnecting any test leads. 2 LCD Display. When power up (Power ON/OFF) is selected your Kewtech KTD30 will default to symbols CERT, INS, this means it is ready to perform a insulation test in Certification mode and it will do this test when you briefly press button 8. CERT INS 8 The Push To Test Button performs two functions: A brief push (less than one second) initiates the test and automatically captures the result (which stays on screen until the next test, Power OFF or Mode change). For Auto Test the button is held down for longer than 2 seconds at which point is displayed in the LCD you now have Hands Free when the probes are touched onto any two test points your KTD30 will carry out an automatic test and capture the result for as long as the probes are held in contact. A brief push on the Test button unlocks Hands Free mode. 4 Overview of the Display 5 I E MΩ D H CERT NUL CONT INS 250V 1000V F C This This how is how the the display will look when when you you first first power power up the instrument. up the instrument. B MΩ G 3 Power ON/OFF Pressing and releasing this button turns the KTD30 on holding down for longer than 2 seconds turns the unit off (plus Auto Power Off is incorporated). A 4 This button selects Insulation Testing Mode (your KTD30 defaults to Insulation Test DC on Power On). 5 This allows selection of insulation test voltage 250V DC for SELV and PELV circuits DC (default) for circuits up to and including and 1000V for circuits abouve (SELV = Separated Extra-Low Voltage. PELV = Protective Extra-Low Voltage). 6 Selects Continuity Test Mode. 7 Continuity Test Lead NULL In order to give accurate continuity resistance results your tester will record the resistance of the test leads store it and automatically subtract the stored value from any continuity measurement being made. To NULL the leads hold the test lead tips together very firmly with one hand and press the NULL Button the result will be displayed continuity testing will then subtract this stored value whenever Test Button 8 is pressed the value is reset to zero after Power OFF (or Auto Power OFF) is selected. A Fuse Broken DO NOT PROCEED B > Greater Than / < Less Than C Battery Condition = good. = 1/2. Flashing = replace. D TestMode CERT Certification E Measuring Mode INS Insulation or CONT Continuity F Insulation DC Volts Test Voltage 250 500-1000V DC G Measuring Units MΩ Insulation Ω Continuity H Null Function (Continuity only) Nulls and stores Ohms value of the test leads for the testing session you are in (automatically resets to zero on switch off) I AutoTest (Hands Free) Selected

Continuity Test Ranges Insulation Test Ranges Accuracy (Cert mode) Ranges (Auto Range) Tolerance (@ 20 C) 0.00 to 9.99Ω ±3% ±2 digits 10.0 to 99.9Ω ±3% ±2 digits 100 to 999Ω ±3% ±2 digits Open Circuit Voltage >4V, <10V 6 Short Circuit Current >200mA 7 Zero offset Adjust (Test Lead Null) Typical Test Time (Cert mode) (2Ω) Power 2Ω <2 sec 4 AA alkaline batteries (not included) Battery Life (BS EN 61557) > 5000 tests @ test voltage Environmental Operating Temperature Range 0 C to 40 C Storage Temperature Range 10 C to 60 C Size 157mm 89mm 39mm Weight 400g Accuracy (Cert mode) Test Voltage Ranges (Auto Range) Tolerance (@200C) 250V 1000V Output Voltage 100 to 199MΩ ±6% ±1 digit 100 to 199MΩ ±3% ±1 digit 200 to 499MΩ ±6% ±1 digit 100 to 399MΩ ±3% ±1 digit 400 to 999MΩ ±6% ±1 digit Voltage Load Output Current Tolerance 250 250kΩ 1 ma 0% +20% 500 500kΩ 1 ma 0% +20% 1000 1MΩ 1 ma 0% +20% Short circuit current (in to 2kΩ) Typical Test Time (cert mode) (10MΩ) <2mA <2 sec

8 Kewtech Corporation Limited Midas House, Unit 2b, Stones Courtyard, High Street, Chesham, Bucks HP5 1DE T: 01494 792 212 F: 01494 791 826 E: sales@kewtechcorp.com www.kewtechcorp.com