Safety drying ovens with expanded temperature range

Similar documents
Safety drying oven with expended temperature range

Safety drying ovens. Advantages: Areas of application: FDL series 115

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Heating oven with mechanical control

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Heating oven with natural convection

Heating oven with mechanical convection

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

MDL series Safety drying ovens with first class safety features and an expanded temperature range

Drying ovens. ED Drying oven with natural convection. Performance features and equipment :

MKT 240 (E3) - Environmental simulation chamber for complex temperature profiles in the low temperature range

Drying ovens. FD 53 - Drying oven with forced convection. Performance features and equipment :

Climate chambers with illumination

Climate chamber with illumination

Refrigerated incubator with Peltier technology

geass.com Environmental simulation chambers for cyclic temperature testing MK MKT series Alternating temperature and climate testing

MK MKF MKT MKFT Environmental simulation chambers

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Model ED 400 Drying and heating chambers Classic.Line with natural convection

Environmental simulation chambers MK MKF MKT MKFT

Dynamic climate chambers. MK MKF MKT MKFT series

FUNCTION LINE HEATING AND DRYING OVENS

C:\Users\Steen Lauritzen\Dropbox\CTS - Citrotek\English quotation text\pharma\cp+10_1200 eng.doc

Cooled incubators (ST), laboratory refrigerators

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5

Ovens. UL Certified Ovens WON, WOF & WOV models. WiseVen. High-Clean Air Ovens

Laboratory refrigerators

0268 Gear tooth calipers

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

INCUBATORS I PAGE 4-8. COMPRESSOR-COOLED INCUBATORS ICPeco PAGE COMPRESSOR-COOLED INCUBATORS ICP PAGE 19-20

DOLI's STANDARD COMPRESSION FLEXOMETER (GOODRICH FLEXOMETER)

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

Zwick. Materials testing. Product Information Temperature chambers for AllroundLine

Automatic filter AF 153 G

Automatic metal-edge filter AF 75 S / AF 95 S

WATERBATHS WNB, WNE, WPE PAGE 4-9 OILBATHS ONE PAGE ADDITIONAL INFORMATION PAGE 14

Automatic filter AF 173 G

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

0280 / 0281 Vernier depth gauges

Flash Point Process Analyzer

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

Differential pressure transmitter PASCAL Ci4 Delta P

FA 016 FAPC 016. Oil Service Units. Description. Page 53

PRODUCT VTS C LOW TEMP. FREEZERS SPECIFICATIONS DIMENSIONS FEATURES LOADING QUANTITIES BIOMEDICAL SOLUTIONS

-86 0 C FREEZER. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

AUTOMATIC FILM APPLICATOR AB3120, AB3220, AB3320, AB3400, AB3125, AB 3225, AB3325, AB3405

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Cytotoxic Safety Cabinets ENVAIR eco safe Plus

Water Baths & Shaking Water Baths. Quality Technology for Routine Applications

GMP dry heat ovens for depyrogenisation and sterilisation

Instruments for the Analysis of Petroleum Products. Oxidation Stability

AUTOMATIC FILM APPLICATOR AB3120, AB3220, AB3320, AB3400, AB3125, AB 3225, AB3325, AB3405

Automatic filter AF 173 G

Ductless mobile fume hoods with modular filtration column

Guth modulating valves. The sophisticated solution

Refrigerators/Freezers

Compression/Tension Testing Machines

GRINDING & POLISHING FORCIPOL FORCIMAT

AVL Particle Measurement System Aviation

Automatic filter AF 112 G

better measurement Simply a question of

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical specification. Recycler WR 2400

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH

Circulation pumps BFP-ATEX-T3/T4

Environmental/Analytical LabCivil Engineering Lab Equipment

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

Catalogue of Accessories

Vent and bleed filter, water-absorbing. Type BFSK 25 to 125. Contents. Features. RE Edition: Replaces: 05.13

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Automatic filter AF 172 G

Optidew Vision Optical Dew-Point Meter

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET

SafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

VAPORIX The Automatic Monitoring System for Active Vapour Recovery

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET.

Process Analyzer. Cold Filter Plugging Point Process Analyzer CFPP-4. Credible Solutions for the Oil and Gas Industry

Mitraset 19 Housings. Housing for electronic instruments

AXIAL FANS Axis / Tubo OPERATION MANUAL

Industries: Aerospace. Optical Electronics ASTM Test Ovens. Automotive. Automotive Components. Petroleum Curing Ovens. Ceramics

Environmental Chamber

EGQ 212: Duct transducer, CO 2 and temperature

Selective Laser Melting Machine

Operating voltage 120, 230 V AC Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size 1

Interface I-300 / I-300 Pro Technical data sheet

Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size (14.1) 55 (32.4) 100 (58.9) Air volume (with exhaust filter installed)

Salt Spray Chamber HKT 1000

Off-line Oil Filter Module Pi 8400

Breathing and air bleed filter, water-absorbing. Type BFSK. Contents. Features. RE Edition: Replaces: 51412

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

LEDEEN SEF. Smart electric fail-safe actuator and control systems

Transcription:

MDL series 115 Safety drying ovens Safety drying ovens with expanded temperature range The BINDER MDL, with enhanced control function, works at temperatures up to 350 C (662 F). It is it perfectly suited for high-temperature testing such as in the coil coating area. Advantages: Defined solvent quantity according to EN 1539 Wide temperature range up to 350 C (662 F) Areas of application: Chemicals Surface Technology

Customer benefits Features Customer benefits Characteristics APT.line Safety concept Performance feature Inner chamber concept Controller Quality Unit options and service Same test conditions throughout the chamber interior Independent of specimen size and quantity Defined solvent quantity Safe standard-compliant drying Short warm up times Broad range of applications, e.g. coil coating tests Maximum occupational safety Easy loading and unloading of specimen material Easy to clean Convenient HMI (Human Machine Interface) Convenient documentation All measured values read at a glance Reliable devices with long service lives Short delivery times Minimal maintenance and operating costs ptimal solution for numerous applications BINDER INDIVIDUAL for customer-specific solutions Worldwide BINDER Service APT.line preheating chamber for maximum precision Uniform circulation throughout the inner chamber Homogeneous temperature conditions throughout test specimens Complies with EN 1539: Fresh air monitoring with automatic switchoff Audible and visual alarm Class 2 temperature limiter Safety class IP 33 Easy to replace fresh air filter High air exchange rate Monitored air exchange volume Large power reserves up to 9 kw Temperature range up to 350 C (662 F) Very tight door closure with 2-point door latch Low heat dissipation due to 60 mm (2.36 inch) insulation Rack with tilt protection Complete inner chamber made of stainless steel No permanent fixtures Silicone free Viton (FKM) door seal Controller with color display and 25 storable programs Integrated digital continuous-line recorder for monitoring limits and alarm function Premium quality made in Germany Highly automated series production (20,000 units per year) High-quality materials, state-of-the-art production technology Comprehensive product portfolio: Various options: coil coating extension, temperature measurement of the specimen, calibration certificate Control and documentation software APT-CM Drying ovens, vacuum drying ovens, climate chambers Worldwide service network

Performance characteristics Electronically controlled APT.line preheating chamber assuring temperature accuracy and reproducible results Temperature range from 5 C (9 F) above ambient temperature to 350 C (662 F) All safety features met according to EN 1539 Heating load 9.0 kw Door gasket made of of high temperature resistant silicone Rear exhaust connector Ø 100 mm (3.9 inch) MCS controller with 25 storable programs of 100 sections each for a maximum of 500 program segments User-friendly LCD screen Easy-to-read menu guide Integrated electronic chart recorder Variety of options for the graphic display of process parameters Real-time clock Replacable fresh-air filter cartridge, class F6 (EU6-fine particle filter for particle sizes between 1... 10 µm) Independent adjustable temperature safety device class 2 (DIN 12880), with acoustic and visual temperature alarm Fresh-air monitoring with audible and visual alarm and automatic deactivation of heating RS 422 interface for communication software APT-CM DataControlSystem 2 chrome-plated racks included BINDER test confirmation

Specifications MDL 115 Exterior dimensions Width (mm/inch) 834 / 32.83 Height (incl. feet) (mm/inch) 800 / 31.5 Depth (plus door handle 50 mm (2 inch)) (mm/inch) 685 / 27.0 Wall clearance, rear (mm/inch) 100 / 3.9 Wall clearance, side (mm/inch) 100 / 3.9 Exhaust duct (outer Ø mm) 100 / 3.9 Steam space volume (l/cu.ft.) 156 / 5.5 Interior dimensions Width (mm/inch) 600 / 23.6 Height (mm/inch) 435 / 17.1 Depth (mm/inch) 435 / 17.1 Interior volume (l/cu.ft.) 115 / 4.1 Racks (number standard/max.) 2 / 5 Load per rack (kg/lbs.) 20 / 44 Permitted total load (kg/lbs.) 50 / 110 Weight (empty) (kg/lbs.) 90 / 199

Specifications MDL 115 Temperature range Temperature range approx. 5 C (9 F) above ambient temperature to ( C/ F) 350 / 662 Temperature variation at 70 C (158 F) (± K) 2 at 150 C (302 F) (± K) 3.4 at 300 C (572 F) (± K) 7 Temperature variation, extension in the door at 70 C (158 F) (± K) 2 at 150 C (302 F) (± K) 3 at 300 C (572 F) (± K) 8 Temperature fluctuation (± K) 0.5 Warm-up time from 2) to 70 C (158 F) (min.) 3.5 to 150 C (302 F) (min.) 6 to 300 C (572 F) (min.) 10 Recovery time after doors were open for 30 sec. 2) at 70 C (158 F) (min.) 0.5 at 150 C (302 F) (min.) 2 at 300 C (572 F) (min.) 4 Recovery time after door was open for 30 sec. 2), extension in the door at 70 C (158 F) (min.) 0.5 at 150 C (302 F) (min.) 1 at 300 C (572 F) (min.) 2 Ventilation (approx. x/min.) 3 Air circulation (approx. x/min.) 40 Exhaust air volume flow (approx. l/min. m³/h) 400 (24.0) Air flow velocity (m/sec) 0.8-1.2 Maximum amount of solvent (g)(lbs.) (at T-180 C, M-100 g/mol, U-40 g/m3, K = 0,5) 6.65/0.014 Electrical data IP protection class acc. to EN 60529 IP 33 Voltage (± 10%) 50 / 60 Hz (V) 400 Nominal power (kw) 9.0 Energy consumption at 150 C (302 F)(W) 1130 1) T = drying temperature M = molecular mass U = lower explosion limit K = solvent vapor concentration as percentage at lower explosion limit

Specifications 2) To 98% of the set value All technical data are specified for units with standard equipment at an ambient temperature of 25 C (77 F) and a line voltage fluctuation of ±10%. The temperature data is determined in accordance to factory standard following DIN 12880, respecting the recommended wall clearances of 10% of the height, width and depth of the inner chamber. All figures are typical average values for series devices. We reserve the right to alter technical specifications at any time.

ptions Door lock Prevents unauthorized access to the process sequences in the chamber. Extension for coil coating applications Extension in the door for quick loading for coil coating / hot air short cycle applications. Calibration certificate & validation BINDER can significantly reduce the workload in qualifying and validating devices. Nobody knows our devices as well and has as much experience in certifications as we do.

ptions MDL 115 Rack,chrome-plated or stainless steel Shelf, perforated, stainless steel Locking door handle with key Keyboard lock Base on castors Door flap for coil-coating tests Replacement air filter (class F6/EU6 fine particle filter for particle sizes between 1 µm and 10 µm), 100 520 22 mm (3.94 x 20.47 x 0.87 inch), with aluminum frame Additional measuring channel for digital display of specimen temperature, with clip temperature sensor. Measured data recorded via RS 422 interface Temperature measurement acc. to DIN 12880 (27 measuring points) at 150 C or at specified temperature with measuring protocol and certificate Factory calibration certificate. Measurement in center of chamber at 150 C (302 F) or at specified testing temperature Extension to factory calibration certificate. Each additional measurement at an additional measuring point or temperature