Pressure regulators E/P pressure regulators Series EV04. Brochure

Similar documents
Pressure regulators E/P pressure regulators Series EV07. Brochure

Pressure regulators E/P pressure regulators Series ED05. Brochure

Pressure regulators E/P pressure regulators Series ED02. Brochure

Flow and check valves Logic valves Logic valves (AND/OR) Brochure

E/P pressure regulator, Series ED07 Qn= 1300 l/min Electr. connection: via signal connection Signal connection: input and output, Plug, M12, 5-pin

Max. particle size 50 µm Max. oil content of compressed air

Max. oil content of compressed air

Directional valves Pneumatically operated, according to standard ISO , 18 mm, CD02-AL series. Brochure

Directional valves Mechanically operated Series AP - inch. Brochure

Max. particle size 50 µm

Flow and check valves Logic valves Pneumatic counters. Brochure

Valve terminal systems Valve terminal systems Series TC08. Brochure

Valve terminal systems Valve terminal systems Series TC15. Brochure

Cylinder Accessories Piston rod mountings, series CM2 Rod clevises. Brochure

Directional valves Electrically operated CL03 series-ev. Brochure

Cylinder Accessories Cylinder mountings; series CM1 Trunnion mountings. Brochure

Sensor technologies Pressure sensors Series PE5. Brochure

Preparation of compressed air Supplementary products Pressure gauge. Brochure

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217

Directional valves Pneumatically operated Series 740. Brochure

Cylinder Accessories Handling connection kits Easy2Combine. Brochure

Directional valves Mechanically operated Series CD07. Brochure

Directional valves Mechanically operated Series AP. Brochure

Ejector, Series EBS Thread connection pneumatic control, T-design with silencer

Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR. Brochure

Ejector, Series EBS push-in fitting electrical control, T-design with release valve with silencer

Rotary actuators Rack-and-pinion gears series TRR. Brochure

Electro-Pneumatic Devices Valves and Positioners. The Drive & Control Company

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Max. oil content of compressed air Shock resistance max. (XYZ direction) Vibration resistance (XYZ direction) Quiescent current consumption

Sensor technologies Proximity sensors Sensor mountings. Brochure

ES05 THE ESSENTIAL valve SYSTEM

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

THE SSI SERIES, SMALL AND SMOOTH THE SHORT-STROKE CYLINDER STANDARDIZED ACCORDING TO ISO 15524

of MSC Series Mini Slides Completely Modular

Short-stroke cylinder, Series SSI Ports: M5 - G 3/8 double-acting with magnetic piston Cushioning: elastic Piston rod: Internal thread

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Pneumatic connection technologies Rotary joints Rotary joints. Brochure

3/2 ways/positions flow diverters L (VS91-VS92-VS95)

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Rodless cylinders Rodless cylinders Series RTC. Brochure

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Proportional pressure relief valve, pilot operated

Proportional pressure reducing valve, pilot operated

5/2-way valve, Series ST Qn= 280 l/min pipe connection compressed air connection output: G 1/8 with spring return

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

2-way proportional throttle valve for block installation

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Max. particle size 5 µm. Pressure for determining piston forces Repetitive precision. Polyurethane

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

6/2 ways/positions flow diverters

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

Proportional pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated

Servo solenoid valves with on-board electronics (OBE)

Electronic pressure switch with integrated analogue output

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Throttle and throttle check valve

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Servo solenoid valves with on-board electronics (OBE)

UNIQUE ADJUSTMENT AND FUNCTION ISO CYLINDERS WITH MODULAR SEALING SYSTEM

Check valve, pilot operated

Supply pressure compensator, direct operated

Proportional pressure relief valve, directly operated, rising characteristic curve

Servo solenoid valves with positive overlap and on-board electronics (OBE)

6 to 12/2 ways/positions bankable flow diverters flangeable

Rodless cylinders Bellow actuator Bellow actuator with mounting ring, series BCR. Brochure

Servo solenoid valves with on-board electronics (OBE)

3/2 ways/positions flow diverters

Pilot-Operated Proportional DC Valve Series D*1FH

Directional servo-valve in 4-way design

6/2 ways/positions flow diverters

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Electronic pressure switch with two switching outputs

6 to14/2 ways/positions bankable flow diverters flangeable

Proportional pressure reducing valve, pilot operated

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Proportional pressure reducing valve, pilot operated

6 to 12/2 ways/positions bankable flow diverters flangeable

Proportional pressure reducing valve, pilot operated, with inductive position transducer

6/2 ways/positions flow diverters

Proportional pressure relief valve, pilot operated

Breather filter. RE 51414/02.09 Replaces: Types BF 7 SL ; BS 7 SL ; BE 7 SL ; B 7 SL

Number of fingers 2. Max. particle size 5 µm. Pressure for determining forces

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional servo-valve of 4-way design

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated

MAREX OS III FOR A SAFE JOURNEY

The New Generation ISO Cylinders for a Dynamic Future

Transcription:

Pressure regulators E/P pressure regulators Brochure

Pressure regulators E/P pressure regulators E/P pressure regulator, Qn= 50 l/min Compressed air connection output: G /8 Electr. connection: Plug, EN 750-80, form C Signal connection: input and output, Plug, EN 750-80, form C Pilot valves Accessories Connector with cable, Series CN form C 8 mm, With coding pin 7 Connector with cable, Series CN form C 8 mm screened 8 Mounting for DIN rail, for EV04 9 Mounting kit, for EV04 0 Silencers, Series SI Sintered bronze Pneumatics catalog, online PDF, as of 07-0-6, AVENTICS S.à r.l., subject to change

Pressure regulators E/P pressure regulators E/P pressure regulator, Qn= 50 l/min Compressed air connection output: G /8 Electr. connection: Plug, EN 750-80, form C Signal connection: input and output, Plug, EN 750-80, form C Pilot valves Version Poppet valve Control Analog Certificates CE declaration of conformity Ambient temperature min./max. +5 C / +50 C Medium temperature min./max. +5 C / +50 C Medium Compressed air Max. particle size 50 µm Max. oil content of compressed air 0. mg/m³ 00656 Qn 50 l/min Mounting orientation vertical Operating pressure See table below Hysteresis 0, bar DC operating voltage 4 V Voltage tolerance DC -0% / +0% Permissible ripple 5% Max. power consumption 0. ma Protection class IP54 Compressed air connection input G /8 Compressed air connection output G /8 Compressed air connection, exhaust G /8 Weight 0.6 kg Materials: Housing Seal Die-cast aluminum; Die cast zinc Acrylonitrile butadiene rubber Nominal flow Qn with working pressure 7 bar, with secondary pressure 6 bar and Δp = 0. bar Technical Remarks The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! The pressure dew point must be at least 5 C under ambient and medium temperature and may not exceed C. The oil content of compressed air must remain constant during the life cycle. Use only the approved oils from AVENTICS, see chapter Technical information. The protection class is only ensured when the plug is mounted properly. For detailed information, see operating instructions. Operating pressure max. Pressure setting range min./max. Nominal input value Actual output value Fig. Note Part No. [bar] [bar] 8 0. / 6 0-0 ma 0-0 ma Fig. - 560000 8 0. / 6 4-0 ma 4-0 ma Fig. - 56000 8 0. / 6 0-0 V 0-0 ma Fig. - 5600 8 0. / 6 0-0 V - - Fig. ) 56000 0. / 0 0-0 ma 0-0 ma Fig. - 56000 0. / 0 0-0 V - - Fig. ) 5600 ) Output 0V constant to supply a potentiometer Minimum working pressure = 0.5 bar + max. required secondary pressure Additional pressure setting ranges available on request Pneumatics catalog, online PDF, as of 07-0-6, AVENTICS S.à r.l., subject to change

4 Pressure regulators E/P pressure regulators E/P pressure regulator, Qn= 50 l/min Compressed air connection output: G /8 Electr. connection: Plug, EN 750-80, form C Signal connection: input and output, Plug, EN 750-80, form C Pilot valves Dimensions ) mounting space for name plate ) electrical connector can be plugged at 90 intervals ) spacer bushings are supplied loose 4) universal threaded connection, suitable for G/8 as per ISO 8/:000 and /8-7 NPTF D56_0 Functional diagram a) V G V T M T Z M b) U P a) Nominal input value, b) Actual output value. The E/P pressure control valve modulates the pressure corresponding to an analog electrical nominal input value. The integrated electronics make a comparison between the nominal input value and the pressure in the output line (actual value). The controller generates electrical input signals, which either ventilate or exhaust control volume Z of the relay valve by means of two pilot valves (M, M) until the specified pressure is attained in the output line. ) Operating pressure ) Working pressure ) Exhaust D56_ Pneumatics catalog, online PDF, as of 07-0-6, AVENTICS S.à r.l., subject to change

Pressure regulators E/P pressure regulators E/P pressure regulator, Qn= 50 l/min Compressed air connection output: G /8 Electr. connection: Plug, EN 750-80, form C Signal connection: input and output, Plug, EN 750-80, form C Pilot valves 5 Fig., Characteristic and pin assignment for current control with actual output value ) supply voltage ) input current nominal value (ohmic load 00 Ω, max. 50 ma. The voltage at the nominal input value may not exceed V. ) actual output value (max. total resistance of downstream devices < 00 Ω). 4) the supply voltage must be protected by an external M 0.5 A fuse. Connect plug via a shielded cable to ensure EMC. A) plug B) plug D56_0 Fig., Characteristic and pin assignment for voltage control with actual output value [bar] 0 5 0 6 5 4 0 0 4 6 8 0 [V] ) ) ) { { { 0 V + 4 V DC 0 V 0... 0 V DC 0... 0 ma 0 V 4) M 0,5 A A) B) ) Supply voltage ) Nominal input value voltage ) Actual output value (max. total resistance of downstream devices < 50 Ω) 4) The supply voltage must be protected by an external M 0.5 A fuse. Connect plug via a shielded cable to ensure EMC. A) Plug B) Plug 00775 Pneumatics catalog, online PDF, as of 07-0-6, AVENTICS S.à r.l., subject to change

6 Pressure regulators E/P pressure regulators E/P pressure regulator, Qn= 50 l/min Compressed air connection output: G /8 Electr. connection: Plug, EN 750-80, form C Signal connection: input and output, Plug, EN 750-80, form C Pilot valves Fig., Characteristic and pin assignment for potentiometer control without actual output value [bar] 0 6 5 4 ) { 0 V + 4 V DC ) M 0,5 A A) 5 0 0 0 4 6 8 0 [V] 4) ) { 0 V 0... 0 V DC 0 V DC B) D56_40 ) Supply Voltage ) Nominal input value voltage ) The supply voltage must be protected by an external M 0.5 A fuse. Connect plug via a shielded cable to ensure EMC. 4) Potentiometer control (0 - kω (min.), 0-0 kω (max.)) A) Plug B) Plug Pneumatics catalog, online PDF, as of 07-0-6, AVENTICS S.à r.l., subject to change

Pressure regulators E/P pressure regulators 7 Accessories Connector with cable, Series CN form C 8 mm, With coding pin Protection class IP67 Operating voltage DC, max. 0 V DC Operational voltage AC, max. 0 V AC Cable exit angled 90 Materials: Cable sheath Polyvinyl chloride 00940 Technical Remarks The specified protection class is only valid in assembled and tested state. For 4 V DC applications, a coding pin is required to protect against reverse polarity. Max. current Contact assignment Number of wires Cable length L [A] [m] [kg] Weight Note Part No. BN BU GN/YE 6 +E 5 0.068 ) 894606 ) With coding pin Dimensions 8 ) 8 50 5m 00797 ) Coding pin Pneumatics catalog, online PDF, as of 07-0-6, AVENTICS S.à r.l., subject to change

8 Pressure regulators E/P pressure regulators Accessories Connector with cable, Series CN form C 8 mm screened Protection class IP67 Operating voltage DC, max. 4 V DC Operational voltage AC, max. 4 V AC Cable exit angled 90 Materials: Cable sheath Polyvinyl chloride 00940 Technical Remarks The specified protection class is only valid in assembled and tested state. Max. current Contact assignment Number of wires Cable length Weight L [A] [m] [kg] Part No. BK BU BN GN/YE 4 +E 4 5 0.95 8946060 Pneumatics catalog, online PDF, as of 07-0-6, AVENTICS S.à r.l., subject to change

Pressure regulators E/P pressure regulators Accessories 9 Dimensions 8 ) 8 5 40,5 M L 0 4675 Mounting for DIN rail, for EV04 0099 0055 Part No. Type Weight [kg] 56004 Mounting for DIN rail 0.06 Pneumatics catalog, online PDF, as of 07-0-6, AVENTICS S.à r.l., subject to change

0 Pressure regulators E/P pressure regulators Accessories Mounting kit, for EV04 P56_05 D56_05 ) use a screw from the proportional solenoid to secure the angle subbase. Part No. Weight [kg] 56005 0.4 for E/P pressure regulator, series EV04, ED04 Pneumatics catalog, online PDF, as of 07-0-6, AVENTICS S.à r.l., subject to change

Pressure regulators E/P pressure regulators Accessories Silencers, Series SI Sintered bronze Working pressure min./max. Ambient temperature min./max. Medium 0 bar / 0 bar -5 C / +80 C Compressed air Materials: Silencers Thread Sintered bronze Brass P00_060 Compressed air connection Sound pressure level Qn Order quantity Weight Part No. [db] [l/min] [piece] [kg] G /8 75 500 0 0.0 87000000 Dimensions D00_06 Part No. Port G SW Ø D L L 87000000 G /8 6 8 6 Sound pressure level measured at 6 bar at m distance Pneumatics catalog, online PDF, as of 07-0-6, AVENTICS S.à r.l., subject to change

AVENTICS GmbH Ulmer Straße 4 0880 Laatzen, GERMANY Phone +49 5 6-0 Fax +49 5 6-69 www.aventics.com info@aventics.com Find more contact information at www.aventics.com/contact Only use the AVENTICS products shown in industrial applications. Read the product documentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. When integrating the product into applications, note the system manufacturer s specifications for safe use of the product. The data specified only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that the products are subject to a natural process of wear and aging. 6-0-07 An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. AVENTICS S.à r.l. This document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS S.à r.l.. It may not be reproduced or given to third parties without its consent. PDF online