Trident Laundry Chemical Delivery System

Similar documents
Trapper Drain Maintenance/Odor Control Chemical Dispensing

DEMA Dispensing. Overview. Warnings. I-1205 Rev. B a digital ware. The DEMA. Nitro Plus is. tee.

DART Ware Wash Speed Control

DEMA SQUIRT DRAIN UNIT

DEMA 951 FLUSH MANIFOLD WITH 24V DC VALVE INSTALLATION INSTRUCTIONS

DEMA S.U.D.S Jr. SINGLE PRODUCT LAUNDRY 581K(I)(S)(V)

Drain Chief Plus Drain Maintenance/Odor Control Chemical Dispensing

DEMAMaster TM DM-811 Series Installation Manual

DEMA Nitro for Europe Ware Wash Chemical Dispensing

DEMA SINGLE PRODUCT LAUNDRY MASTER TM W/BLEACH OPTION INSTALLATION INSTRUCTIONS LIQUID MODEL 840 (B)(S)

BIOACTIVE SOLUTIONS AC DRAIN STATION

DEMA 259B DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

DEMA Pro-Fill I Sink Dispenser

DEMA 652 DUO-FEED INSTALLATION INSTRUCTIONS

Spray Clean 606T-2 Installation Instruction

DEMA MODELS 606T INSTALLATION INSTRUCTIONS

DEMA Pro-Fill II Sink Dispenser

DEMA MODEL 603T-WI INSTALLATION INSTRUCTIONS

DEMA MODEL 606T-WI INSTALLATION INSTRUCTIONS

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

DEMA MODEL 604T-WI INSTALLATION INSTRUCTIONS

DEMA MODEL 582 FOAM STATION III INSTRUCTION SHEET

ALWAYS FOLLOW ALL SAFETY PRECAUTIONS AS DIRECTED BY THE CLEANING CHEMICAL LABEL

I Button Chemical Dispenser. Overview. Installation Instructions

DEMA 651AG SINGLE-FEED INSTALLATION INSTRUCTIONS

DEMA DILUTION-AT-HAND EXTREME 800 Series Chemical Dispensers

23200 Navigator Dilution Control System 4 Button Model (NAV 4)

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

DEMA SPRAY CLEAN MODELS: 244CDF & 244CDFT INSTALLATION INSTRUCTIONS

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

DEMA SPRAY CLEAN MODELS: 244BC, 244BCE, 244BCP & 244BCT INSTALLATION INSTRUCTIONS

TABLE 1. * SPECIFY S Stainless Steel Knob Part No S or Part No ST (for tips) for pressure exceeding 700 PSI.

PeroxiDraw Dispenser

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

DEMA RAPID FIRE MODELS 6300, , , , 6310, 6300H 6300E, 6300EH, &6310E INSTRUCTION SHEET

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

Spray & Foam Dispenser Item #

665 Series Dispenser. Metering tip kit

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

DEMA SPRAY CLEAN MODELS: 241CDF & 241CDFT INSTALLATION INSTRUCTIONS

DEMA SINGLE-FEED MODEL: 651GAP& 651GAP-1 INSTALLATION INSTRUCTIONS

900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg.

Caution! Pg. 1 of 5 I-932

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

DEMA Model 294D Spray Foam INSTALLATION INSTRUCTIONS

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE.

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

Items # and #

Certo Chemical Dilution System

Reference Manual FM-200 Series

910 BHF OWNER S MANUAL. Pg. 1 of 9

DEMA MIXRITE PROPORTIONING PUMP MODELS 574 & CL & 575CL FOR CORROSIVE LIQUID CHEMICALS INSTALLATION INSTRUCTION.

ILCS EDGE System Installation Manual

Crescent Flush Manifold FOR LIQUID LAUNDRY SUPPLY SYSTEMS

SAFETY INFORMATION & INSTRUCTION MANUAL

FLUSH MANIFOLD REFERENCE MANUAL FOR LIQUID LAUNDRY SUPPLY SYSTEMS. FM-500 Series. P/N Rev. C

D EMA TWO-STAGE INJECTOR MODELS 233, 234A, 236A, 236-8, 238, AND 2312 INSTALLATION INSTRUCTIONS FIGURE 3 FIGURE 2

Intended Use: Explanation of Signal Word Consequences

DEMA 257C / 257CV PRO BATTERY DRAIN CHIEF INSTALLATION & OPERATING INSTRUCTIONS

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

ILCS EDGE Jr EDP Installation Manual

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

L5000 Plus. Installation & Setup Guide

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

415DS AUTO DISCHARGE WET SOLUTION VAC PARTS MANUAL REV A

ECLIPSE Laundry Dispenser Controller

ALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC

SCHEDULE 80 PVC PRESSURE FITTINGS L80P EFFECTIVE JULY 1, 2017 REVISED PRODUCTS PRICE LIST INCLUDES: SCHEDULE 80 PVC 1/4 TO 12

MITYFLEX PERISTALTIC PUMPS

Tools Needed for Mounting Cleá Filling Station

On-Premise Pro Instruction Manual

VSP SERIES Installation, Operation and Maintenance Manual

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

QUEST NT. Illustrated Parts List. Release Date: August 17, 2004 Publication Number: IPL Revision Date: July 28, 2015 Revision: J

Electronic Service Manuals

CHEM-FEED. Engineered Skid Systems. ProSeries. by Blue-White Ind.

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG BUNN-O-MATIC CORPORATION

Operating Instructions for the. In Line Conveyor System West Cabot Boulevard Langhorne, PA w w w.empire-airblast.

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

Ball & Socket Fittings (Bauer Style)

PPM EO-100 TM. Operation Manual

SWING JOINT & HEAVY TURF

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

MODEL EVA PARTS MANUAL Rev.1.05

SOLUTION STATION Instruction Manual

LDS-455 PREWETTING SYSTEM

Manifold QF. Contents. Description. Installation & Setup Guide. Safety 3. Introduction 3. Installation Standards 4. Specifications 5.

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

Outdoor Bottle Fillers

Installation & Operator s Manual

OP-500 On-Premise Series Instruction Manual

Transcription:

Trident Laundry Chemical Delivery System Installation and Setup Guide The DEMA Trident is a complete laundry chemical delivery system for commercial laundry applications. The Trident features Bluetooth connectivity for programming using the Trident App on smart devices and PC. Warnings Installation of DEMA products must meet all applicable electrical codes and regulations established by national, city, county, parish, provincial or other agencies. It is possible that electrical codes and regulations require that a certified electrical contractor or engineer perform the electrical installation. For questions, contact a certified electrician. All installations must conform to local plumbing codes and use approved backflow prevention devices. A pressure indicating tee is to be installed with existing faucets according to local plumbing codes in the state of Wisconsin and any other state that requires the use of a pressure indicating tee. ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH CHEMICAL PRODUCTS. I-1225 Page 1 of 9

Installation WARNING: INSTALLATION OF DEMA PRODUCTS MUST MEET ALL APPLICABLE ELECTRICAL CODES AND REGULATIONS ESTABLISHED BY NATIONAL, CITY, COUNTY, PARISH, PROVINCIAL OR OTHER AGENCIES. IT IS POSSIBLE THAT ELECTRICAL CODES AND REGULATIONS REQUIRE THAT A CERTIFIED ELECTRICAL CONTRACTOR OR ENGINEER PERFORM THE ELECTRICAL INSTALLATION. FOR QUESTIONS, CONTACT A CERTIFIED ELECTRICIAN. 1. Determine a suitable location to mount the Trident. The following should be considered: a. Length of power cord. The power cord is 10ft long and includes an 115VAC plug for wall outlet. The plug can be cut off so that the power cord can be hardwired or retrofitted with a different type of plug. Electrical requirements described on step 7. b. Length of Trident communication cables. The standard cable lengths are: i. 25ft - Trident Pump Stands to Pro Access - and Trident Pump Stand to Trident Pump Stand ii. 8ft Trident Pump Stand to Pro-Connect (STU) iii. 8ft - Pro-Connect (STU) to Pro-Select (formula selector remote). c. Avoid wet areas d. Easy access for interfacing the buttons and display on pump stands and Pro-Access e. Chemical container location f. Wall or mounting surface must be suitable to attach (screw) the DIN mounting bracket. 2. Mount the mounting bracket on the wall or on the DIN rail. Appropriate screws and anchors must be used based on the type of wall material. A level should be used when mounting the DIN rail. 3. Mount the Trident by hooking it onto the DIN mounting bracket. 4. Lock the Trident to the DIN rail by sliding the DIN Rail lock up and locks into place. 5. Install and mount the Pro-Access, Pro-Connect and Pro- Select (see individual instruction guides for each component) 6. Connect the Trident communication system - See Cable Wiring Diagram on next page for cable connections 7. Connect main power cord by plugging into a 115/230VAC wall outlet. The power cord has a 115VAC plug. The plug can be cut off and the power can be hardwired to a power source or an alternate plug. The Trident will accept power between 100 and 250VAC 50/60Hz 2.0A. 8. Connect chemical pickup and discharge tubing to the chemical pumps. Trident is equipped with either John Guest push-on fittings or barb fittings at chemical pumps. 9. Install chemical lines at the chemical containers and either a flush manifold or the laundry machine chemical injection connections. 10. Prime chemical pumps either using the Pro-Access or at the face of the Trident pump stand or the Trident App. a. Trident pump stand push the left arrow button and a P1 will be displayed. Press Enter to start and stop the pump. Use the Up and Down arrow buttons to choose additional pumps. Use the right arrow button to exit priming. b. Pro-Access and App Find the priming function in the pump stand menu 11. See Pro-Access manual for programming. Additionally, the Trident App can be used to program the Trident using a smart phone/pad or PC. Hook the Trident main module and pump modules onto the DIN rail DIN Rail Lock Push (slide) the lever up to engage the DIN rail lock. Release Pull lever slightly away from wall and slide down. I-1225 Page 2 of 9

I-1225 Page 3 of 9

Replacement Modules Trident Pump Driver Module Assembly Components 1 81.447.1 DIN Rail 3 pump 2 86.100.17 Trident Pump Driver Module 3 84.204.21 Large Blue Pump Module,105RPM, EPDM Sqz Tube, 3/8 JG Ready 4 Large Blue Pump Module,105RPM, EPDM Sqz Tube, 3/8 Barb 81.198.40 Small Blue Pump Module,105RPM, EPDM Sqz Tube, ¼ JG Ready Small Blue Pump Module,105RPM, EPDM Sqz Tube, 3/8 Barb 5 81.198.41 Flush Valve Module 6 81.144.1 Pump Module Connecting Pins I-1225 Page 4 of 9

Pump Driver Replacement Parts Trident Pump Driver Module Assembly Components 1 86.100.11 Pump Driver Enclosure Back Assembly 2 86.100.12 Control Board Mounting Bracket Assembly 3 86.100.13 Pump Driver Enclosure with labels and mounting screws 4 86.100.14 Power Supply Kit 5 84-125-12 Power cable (internal) 6 86.100.15 Power Connector/Switch Module with mounting hardware 7 81-147-1 Key Pad 8 86.100.16 Trident Control Board Assembly (includes main board & display) 9 84.440.3 Power Cord w/115vac Plug 10 58-60 #6 x ½ Hi-Lo Screw (for plastic) 11 81-20-2 #4 x 3/8 Hi-Lo Screw (for plastic) 12 41-40-2 #6-32 x ½ Screw I-1225 Page 5 of 9

Small Blue Pump Replacement Parts Trident Quick Change Pump Replacement Parts - small blue pump 16oz/min or (460ml/min) 1 41.40.2 #6-32 Screw 2 81.173.9 Pump and Motor Assembly 105 RPM 3 81.197.1 Pump Module Enclosure Assembly (small blue pump) 4 84.434.1 Pump Module Enclosure Back (small blue pump) 5 44.116.2 #8 x 3/8 Hi Lo Screw (for plastic) 6 81.147.1 ½ Hole Plug 7 81.183.5 ½ Cable Strain Relief 8 81.196.10 Cable Assembly Trident Quick Change Pump Replacement Parts - Small blue pump 16oz/min (460ml/min) 1 81.174.1 Small Pump Cover 2 81.177.1 Squeeze tube EPDM 7/16 OD x ¼ ID JG Ready ¼ Stem 81.177.6 Squeeze tube EPDM 5/8 OD x 3/8 ID 3/8 Barb 3 81.172.1 Roller Block Assembly 4 25.85.2 10-32 x ½ Screw 5 81.128.2 Small Pump Base 6 80.59.105MK 105 RPM Motor 24VDC I-1225 Page 6 of 9

Large Blue Pump Replacement Parts Trident Quick Change Pump Replacement Parts - large blue pump 50oz/min or (1500ml/min) 1 41.40.2 #6-32 Screw 2 84.205.1 Pump and Motor Assembly 105 RPM 3 84.206.1 Pump Module Enclosure Assembly (large blue pump) 4 84.433.1 Pump Module Enclosure Back (small blue pump) 5 44.116.2 #8 x 3/8 Hi Lo Screw (for plastic) 6 81.147.1 ½ Hole Plug 7 81.183.5 ½ Cable Strain Relief 8 81.196.2 Cable Assembly Trident Quick Change Pump Replacement Parts - Large blue pump 50oz/min (1500ml/min) 1 84.209.1 Large Pump Cover 2 84.208.1 Squeeze tube EPDM 5/8 OD x 3/8 ID JG Ready 3/8 Stems 84.208.2 Squeeze tube EPDM 5/8 OD x 3/8 ID 3/8 Barb 3 84.207.1 Roller Block Assembly 4 25.85.2 10-32 x ½ Screw 5 84.188.1 Large Pump Base 6 80.59.105MK 105 RPM Motor 24VDC I-1225 Page 7 of 9

Pump Driver Control Board and Power Supply Wiring Diagram Control Board with Display Power Supply Power connector mounted at bottom of the Trident pump driver module Internal Power Cord Part numbers for these parts can be found on the Pump Driver Replacement Parts Diagram in this instruction guide Kit and Accessory Items DEMA Part No. Description 81.182.3 3/8 x 3/8 John Guest Union (2 included with Trident for each large blue pump) 81.182.5 3/8 x ¼ John Guest Union (2 included with Trident for each small blue pump) 58.110.1 ¼ John Guest Tee 58.110.2 3/8 John Guest Tee 58.103.2 ¼ John Guest x ¼ MPT Straight Fitting 58.104.2 ¼ John Guest x 1/1 MPD Elbow Fitting 81.195.1 ¼ Male Stem (JG) x ¼ Female (JG) Elbow Fitting 95.31 ¼ JG x Garden Hose Adapter 95.32 3/8 JG x Garden Hose Adapter 83.16.1 Velcro Patch (2 included with Trident) 86.100.10.2 Trident Connect w/25 Cable Kit (included with Trident) 86.100.8.1 Trident Pro Select w/8 Cable Kit (optional end user formula selector) 86.100.9 Trident Pro Access Kit 25.115.100 3/8 OD x 100 LDPE Tubing 25.163.100 3/8 OD x 100 EVA Tubing 25.164.100 ½ OD x 100 EVA Tubing I-1225 Page 8 of 9

Specifications Main Power 115/230VAC 50/60Hz 2A Pump Motor/Valve Output 24VDC 1.25A Operation Temperature 40 F 115 F (5 C 45 C) CE Bluetooth Warranty Merchandise Returns No Merchandise will be Returned for Credit Without DEMA S Written Permission. Returned Merchandise Authorization Number is Required in Advance of Return. Product Warranty DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products that have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, or misapplication. Rubber and synthetic rubber parts such as o -rings, diaphragms, PVC tubing, and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty is void. Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability for damages. Return merchandise authorization number must be granted in advance of returned units for repair or replacement (See Merchandise Returns above). I-1225 Page 9 of 9