WARCO CHEMAG SERIES GH FILTERS

Similar documents
PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

HARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL

Installation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC

NECO Pumping Systems

SELF PRIMING CHEMICAL SERVICE PUMPS

OPERATING AND MAINTENANCE MANUAL BATCH PRESSURE FILTER 3 GALLON CAPACITY

Portable Filter Carts Models 5MF and 10MF

SAND FILTERS. Models: ECSF500, ECSF650, ECSF700, & ECSF800

Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

To ensure proper installation, digital pictures with contact information to before startup.

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

Installation & Operating Manual

INSTRUCTION MANUAL AND PARTS LIST FOR 3E CANNED MOTOR PUMPS

Operation & Service Manual

OPERATION AND PARTS MANUAL

WMTA6 LN SERIES SEAL-LESS MAG-DRIVE MULTI-STAGE TURBINE PUMPS

Sand Filtration System

S200-G Series Centrifugal Fire Pumps Operation and Maintenance Instructions

HARMSCO Filtration Products BC6 Series

GL Ludemann Y-Strainers

Suction Diffuser - Iron Body Style PSD 125# Flanged 2 x 1-1/2 thru 20 x Technical Data...3

Low Profile J Series Power Unit with Vane Pump

SINGLE-STAGE INJECTOR MODELS 200-3C, 200C, 201C, 202C, 203C, 204C, 206C, 208C

Artesian2 Owners Manual

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

Manual for 12 Sand Filter/ Pump Combo Unit.

BGT Series. Low Pressure Filters

Operating instructions Form no safety definitions

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

Heavy Duty Sprayer Owners Manual Model MS-O

Hydraulic and Commissioning Mannual Module 2A

SERIES PC INSTRUCTION AND OPERATION MANUAL

Artesian Owners Manual

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Marine Fuel Filtration Marine 800 Series

8000 / 10,000 / 12,000

DYNAFLUID 2000 STEAM & WATER MIXING VALVE INSTALLATION & OPERATING MANUAL

Pump Operating and Maintenance Manual - Models

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Rosedale Model HSS300 and HSS750 Single Cartridge Housings for Liquids

Section 6.1. Implement Circuit - General System. General: Implement Control Valve:

Clean & Clear Filter System Owner's Manual. Important Notice WARNING

The presented symbols are safety alert symbols. Be alert to potential personal injury in case symbols on the product or in this manual are shown.

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

PSR-HP-3000 MANUAL HAND PUMP INTERNAL LIQUID CAPICITY MAXIMUM OUTPUT PRESSURE PsiG (BarG) GALLONS (LITERS) 3000 (207) 5 (19)

High Performance, Corrosive Handling Filtration Equipment

CLAY VESSEL MANUAL (VC Series Vessels)

OWNER S MANUAL. 6. If you aren t competent to instal the pump, get help from a qualified source.

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

CSO / CP PUMPS Vertical Spindle Type Installation, Operation and Maintenance Manual

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

POND PUMP Model Nos:SPP3 & SPP6 0200

Installation Manual. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION

Parker Hannifin Filtration Group Racor Division DUAL FBO OPERATION AND MAINTENANCE INSTRUCTIONS SPARE PARTS

Portable Filter Carts 10MFP with Moduflow

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

Installation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

FPS- 80. Manual. Reverso Pumps, Inc. Ph: (954)

MAINTENANCE MANUAL DI 16

CASH VALVE K SERIES BACK PRESSURE VALVES

NECO Pumping Systems

Operating and Installation Instructions

RP-CS 2-98 CERTA-SEAL LIQUID BAG FILTERS WITH THE MATCHED PERFORMANCE DESIGN. Products

Compact LTC Oil Filtration System Manual

Operation & Service Manual

Fire Engine Dump Valve

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

B14 AAA FINE FINISH SERIES PUMP OUTFIT

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

B14 AAA FINE FINISH SERIES PUMP OUTFIT

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

VSP SERIES Installation, Operation and Maintenance Manual

OPERATION AND SERVICE MANUAL. McGILL UNIVERSITY PROJECT: MCS-3237 SUBJECT: HYDRAULIC POWER UNIT AND ROTARY ACTUATORS DECEMBER 2001

Check List for Optimal Filter Performance

M-3025CB-AV Fuel Pump

Operating Manual for Rotary Gear Pumps CMI, S.A. (Mendaro, Guipuzkoa, Spain)

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Installation, Operation and Maintenance Manual

Installation Vertical Pump: Installation 'CM' and 'CDM' Style: Operation:

H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT

Series Base mounted pump. Installation and operating instructions

Voltmaster Centrifugal Trash Pumps

Pneumatic High-Viscosity Filtration System Instruction Manual

100 Series Flow Switches Technical Reference Manual

TYPE E Main Valve Sizes 3 /8 through 12

MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL

Tests & Adjustments - General Machine. General Safety Hydraulic Tank Turbo Boost Regulator

Instructions for Installation, Operation, Care and Maintenance

Oil Solutions. TTF/BGTS Series Return In-Tank Filters. Global Filtration Technology. Filtration.

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR SERIES 470 VM VERTICAL MULTISTAGE PUMPS

Transcription:

WARCO CHEMAG SERIES GH FILTERS High Performance Pleated & Bag Type Filtration Systems INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Thank you for your purchase of a WARCO Series GH Filtration System. With proper installation and maintenance you can expect many years of trouble free operations. Failure to follow the recommended procedures may result in early and severe damage to your WARCO Filter System, and may also invalidate the warranty. SAFETY NOTE: Plant operations and maintenance personnel should follow proper safety guidelines (e.g. OSHA) when servicing this equipment. Safety glasses and hand protection should be the minimum safety protection. Safety goggles are recommended during filter change-out of elements or media due to overhead suspension and risk of chemical spray or splash. 1) SYSTEM MONITORING The WARCO Series GH high performance bag filtration systems are sold with or without centrifugal magnetic drive or mechanical seal type pumps. If using a pump special attention should be given to the recommended operating pressures for these pumps to prevent pump damage resulting from deadheading, dry-running or cavitation. Constant monitoring with flow meters or a power monitors will indicate critical minimum flow setting (i.e., bath turnover rate) for filter change-outs. Air leaks in the suction line will lead to pump cavitation, which is normally indicated by erratic pressure readings on the filter gauge (s). Please refer to pump s operation and service guide for complete pump installation, start-up and maintenance. Pump Protection: Do not operate the pump in a closed discharge (dead head) condition for extended time periods (< 1 minute). If using a centrifugal pump that is not a self-priming type, a flooded suction will be required to maintain proper prime for the system to function properly. 2) INSTALLATION WARCO Filter Chambers are shipped completely assembled and ready for installation. Please note filter media is sold separately. It is recommended that the system be located as close as possible to the process tank. Also, the nominal pipe diameter of the pump suction port must be adhered to when sizing the suction and discharge line to ensure proper flow velocities. Do not decrease the pipe size of the suction or the discharge pump connections. It is recommended to use schedule-80 slip joint glued fittings for plumbing the unit (s) to and from the process tank. Sharp 90 degree fittings (elbows or tees) should be mounted a minimum of 10 pipe diameters from the pump inlet to prevent turbulence and excessive wear of the pump components. WARCO filter systems are free standing and stable when placed on flat level surface. We strongly suggest installing ball valves in front and after the filtration system. By closing off inlet and outlet valves when system is shut down, this will prevent back siphoning and flooding. Also installing a drain line will help out when changing out filter media. The use of suction strainer (s) is recommended when large solid particulate matter is present and could enter the pump. Oversized strainers are recommended to prevent an excessive flow restriction. The 1

strainer should be mounted a minimum of 10-20 pipe diameters from the pump inlet. The screen size should be 20-50 mesh. A regular maintenance schedule should be implemented to prevent flow restriction of the pump. Installing additional pressure gauges on the inlet and discharge side of the strainer (s) this will allow for monitoring a pressure drop for proper maintenance. 3) PRELIMINARY OPERATION Please take a moment to record all the model, serial, and product code numbers. This information will come in handy for future references and filter media replacement. Care should also be taken to protect the pump components against unnecessary wear and physical abuse. Review parts list and maintain an emergency inventory of pump replacement items to assure that unit is returned to service with the least delay. Prior to start up, open the chamber (s) lid cover assembly to inspect the internals; see if the filter media is installed correctly inside the perforated support basket. Also check to make sure the correct matching retaining seal ring BAG, or CART is installed, and the arrow is pointing upward, an all rubber gaskets are in place. When the chamber s lid is shut, and bolted hand tight, all of the internal components will squeeze together to form a positive seal. This positive seal will prevent incoming solution to bypass the filter media. To prevent dry running of the pump on start-up, pour 1 or 2 gallons of solution inside the chamber to fill the pump casing. Close top lid, and tighten the knobs evenly by hand, no tools are not necessary. Inspect all pipes, hose fittings and band clamps to ensure that they are secured, to prevent possible leaks. Throttling a discharge valve to the maximum recommended pump pressure can perform pressure testing the complete system, further inspection of all pipes and fittings should then be made. Pump Protection: Do not operate the pump in a dead head condition for extended time periods (<1 minute). The minimum recommended operating pressure is necessary to prevent pump operating at run-out, which is subsequent pump damage due to cavitation. Inducing backpressure may be required on systems with low head pressure by throttling a discharge valve or installing an orifice. 4) ELECTRICAL All single-phase units are factory wired for 120-volt operation. For three-phase operation, the installation of external fused discount switch and motor starter (supplied by others) should be installed near each unit. Rotation for the system s pump motor must be correct. Refer to pump s manual for details. View the motor from the fan end, and bump start the pump motor to verify correction rotation. The motor fan blades should rotate counter clockwise. A qualified licensed electrician should do all wiring and connections. For added pump and media protection consider LINEMAN pump power monitors that can be programmed for safe minimum and maximum operating conditions. 2

5) INSTALLING FILTER MEDIA The filter media can be either a bag, or pleated cartridge type. Please note filter media is sold separately. If using a bag style media, you will need the matching round top retaining ring for proper sealing. This ring is marked with the word BAG stencil on the side of it. If you re using pleated style cartridges, you will need the corresponding retaining ring with the word CART engraved on the side of it. Please contact the factory if you do not have the correct sealing ring (s). The incoming contaminated process solution will enter the top of chamber and flow out thru the bottom. The filter chamber design features a flow path from inside to outside of the media. Both the bag or cartridge style media are single open-end (S.O.E) design, which retains solid materials inside the media itself. Therefore the filter media needs to be installed with the opening at the top of chamber facing upward. Also the top round retaining ring has a stencil arrow on it. This arrow needs to be installed pointing upward towards the lid cover. NOTE: Process solutions that are sensitive to entrained air require venting of the chamber prior to restarting. 6) OPERATION WITH ABSOLUTE RATED PLEATED ELEMENTS Open all inlet/outlet valves and energize the pump motor. As the filter chamber media removes contaminants from the process tank, the pressure drop across the unit will slowly rise. This can be observed by having a pressure gauge guard assembly installed on the chamber s lid cover. In normal operation typically it is desirable to change the filter media when it reaches 7 PSI above the initial pressure drop depending upon the type of media. Do not exceed 10 PSIG differential pressures across media. A drop in flow will reflect a rise in pressure if a centrifugal pump is being used. When the flow drops below an acceptable point, the filter media should be changed. 7) GRANULAR CARBON READY BAGS Activated carbon is an effective method of removing organic impurities from plating baths and other chemical solutions. Carbon Ready Bags are equipped with an internal PP sleeve to prevent short circuit of the carbon column for longer resonance time. Proper carbon treatment requires a low flow rate/contact time to properly activate with the process solution by means of adsorption of the impurities. The quality of solution purification is controllable by the contact time between the solution and the carbon. The flow through the carbon should be adjusted to 1 to 3 GPM flow rate for each pound of carbon that is being used. A flow meter installed on the carbon chamber piping will facilitate flow adjustment for establishing the desire flow rate thru the chamber. TO REPLACE FILTER MEDIA (Cartridges or Bag Elements) Shut down the pump. Close all inlet and outlet valves. Open drain valve to relieve pressure and drain chamber. SAFETY NOTE: Do not attempt to open the chamber top cover until pressure has been relieved through a vent or drain valve after pump is shut down. After system and filter pressure have been relieved, loosen lid Tee handle cover hold down bolts. Lift lid cover straight up from the shell. Please note the chamber features a tilt lid design. This allows the lid to remain upright in place while servicing the unit. 3

a. Remove round retaining seal ring, and lift either the spent cartridge or bag element straight up and out of chamber. b. Review section on Installing Filter Media (see page 2). Insert new media, retaining ring, close lid and hand tighten all Tee handle swing bolts- no tools are necessary. c. WARCO offers you a variety of CHEMTREX filter media with various micron ratings from 0.5 to 125 microns for fine-tuning your process requirements. 8) GASKET INSPECTION Depending upon the operating conditions (e.g. temperature, pressure, chemistry, etc.) and frequency of filter element change-outs, the square chamber lid gasket should be inspected and changed on an annual basis to avoid costly leakage or spills. Special care should be taken to thoroughly clean and rinse the gasket seat before installation to avoid potential leak pathways from the bridging effect of solid particle. 9) PUMP OPERATION Refer to the pump Installation, Operation & Maintenance (IOM) manual for complete pump guidelines. 10) MOTOR OPERATION Refer to the motor Installation, Operation & Maintenance (IOM) manual for complete motor guidelines. 4

Warco, Inc 821 Sivert Drive Wood Dale, IL 60191 Tel. (847) 549-8695 Fax. (847) 549-8696 E-mail: sales@warcoinc.net - Web-site: www.warcoinc.net 5