MAG- Backflow Preventers. MAG-BEECO Backflow Preventers deliver the highest level of performance, reliability, ease of use and save time and money.

Similar documents
MADE IN THE USA BACKFLOW PREVENTERS

THE DEFENDER 4D-200 SERIES

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

DOUBLE CHECK VALVES SERIES PRODUCT CODES OPERATION MEDIUM HAZARD RATING. 20mm - 50mm FEATURES APPLICATION SPECIFICATION STATEMENT DESCRIPTION

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

BACKFLOW PREVENTION CATALOG

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

4P-300 4V-500 CONTINUOUS PRESSURE THERMOPLASTIC DUAL. PRINCIPLE (U & Z Flow) DUAL CHECK VALVE. PRINCIPLE (Stn.Steel) REDUCED PRESSURE

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

PRESSURE REDUCING CONTROL VALVE

INSTALLATION & MAINTENANCE MODEL mm

Backflow Prevention. Quick Reference Guide

Cash-Flo. Operation & Maintenance Manual. BackFLOW PREVENTERS. A Division of the Reliance Worldwide Corporation

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

Backflow Preventers TABLE OF CONTENTS

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

Valve Selection. 1. Function and service considerations

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

AMES 2000 SS/2000 SE. BASIC REPAIR KIT Repair kit contains all check modules and O-rings

Backflow Preventers & Accessories

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

SECTION VALVES PART 1 -GENERAL

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

Flood Control Integrated System (FCIS)

HERSEY 6CM SIZE 2 1/2", 3", 4", 6", 8", 10"

Backflow Prevention Products

Backflow Irrigation Control Station BIC-1000

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Irrigation Series. Backflow Preventers, Water Pressure Regulators, and Water Control Products for Irrigation Applications

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

BEECO-2018 LIT mifab.com/ index.html. Distributed by:

Stainless Steel The Next Generation of Backflow

Deep Well Pump Control Valve

BACKFLOW PREVENTION CATALOG

FILTERS, STRAINERS AND VALVES PRODUCT GUIDE

PRESSURE RELIEF VALVE CONTROL VALVE

THIS WARRANTY IS IN LIEU

Instructions for Installation, Operation, Care and Maintenance

Colt Series C400, C500

Section - L. Antipollution devices

A. This Section includes the following domestic water piping specialties:

Herpteraium SECTION VALVES GENERAL

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

FLOW CONTROL. PRODUCT GUIDE WATER CONTROLS FOR A MODERN WORLD HEATING SYSTEM COMPONENTS HEATING & COOLING DISTRIBUTION SYSTEMS


SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

35 Dealing with Type II and N Pattern Assemblies Pete Chapman

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

SECTION PLUMBING PIPING VALVES AND ACCESSORIES PART 1 - GENERAL

Victaulic Fittings, Couplings, Valves & Sprinkler Heads for the Fire Sprinkler Market Keeping the art of distribution simple

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Valves & Flow Control Components Valves & Flow Control Components

PRESSURE REDUCING VALVES

Transportation Products

of wet barrel hydrants, hydrant valves and hydrant tools.

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Irrigation Solutions. Backflow Preventers, Water Pressure Regulators, and Water Control Products for Irrigation Applications.

LEAD FREE * PVS-7000 Engineered Flood Protection Valve Station with SentryPlus Alert

Instructions for Installation, Operation, Care and Maintenance

Index. Butterfly Valves

GO WITH THE FLOW! PRODUCT GUIDE TITAN FLOW CONTROL, INC. TITAN TELEPHONE: YOUR PIPELINE TO THE FUTURE!

Table Summary of Sprinkler System Inspection, Testing, and Maintenance. Reference. Inspection , ,

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

FM 3. FM 3 with Bypass. Materials and Specifications. Fire Service Meter with Bypass Sizes 3, 4, 6, 8, 10. Features

DELUGE VALVE DATA SHEET

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

Backflow Prevention Products and Parts

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

DV-5a Automatic Water Control Valve Double Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Maintenance Manual Double Check and Double Check Detector Assemblies Series 850, 856, 870V & 876V 2 1 /2" - 10" (65 250mm)

1. All piping shall have flow arrows indicating direction of flow.

SECTION METERS AND GAGES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Series 990/990RPDA. Reduced Pressure Zone Backflow Preventer. Sizes: 4", 6", 8" (100mm, 150mm, 200mm)

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.

SCOPE OF WORK WASTEWATER TREATMENT PLANT THE WORLD LEADER IN PIPE JOINING SOLUTIONS

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Series 995/995RPDA. Sizes: 3" - 6" Reduced Pressure Zone Backflow Preventer/ Reduced Pressure Detector Assemblies RP/IS-995/995RPDA

Athletic Field Painting Pointers Line Star Drawing Line Star Parts List 3-4. Spray Boom Drawing Stainless Steel Tank 6

This catalog contains the following geothermal accessory products and specification guides:

T200 Pressure Regulator

Michigan State University Construction Standards. GENERAL-DUTY VALVES FOR PLUMBING PIPING Page

w w w. w a t t s. c o m

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION VALVES

RESILIENT SEATED GATE VALVE FAF 6200

Transcription:

MAG-BEECO deliver the highest level of performance, reliability, ease of use and save time and money. BENEFITS Peace of Mind MAG-BEECO Backflow valves pass the most rigorous, stringent test standards and are designed with safety in mind. You won t be kept awake at night wondering if your backflow valve is doing its job. Savings on maintenance and commissioning MAG-BEECO s Modular Body construction means you can instantly convert from a Double Check to a Reduced Pressure Zone. Maintenance is easy as repair parts are modular: it only takes two relief valve kits and three check repair kits to cover all sizes. This means you don t need an unmanageable and costly array of parts making BEECO valves not only the easiest valves to service, but maintenance contracts will be cheaper. And your scheduling service won t be delayed either. Easy valve access MAG-BEECO covers for both our epoxy coated ductile iron and brass products are easily accessible. A single bolt enables you to remove the brass cover. On our large ductile iron products, we have eliminated the numerous bolts of other products and replaced them with a simple pipe coupling that is not under pressure. The valve can be exposed within minutes again saving time and money. Easily replaceable Check Valves Once you have accessed the valve with our easily removable covers, we have also solved the problem of broken checks with our easily replaceable checks. No more frustration, wastage and extra cost of checks being broken while prying them out for repair. A simple pair of pliers enables you to grab a well-designed, innovative metal nipple and just snap the part out with ease. AS/NZS 2845.1 Lic: WM 74542

Fire Detector Check Valves APPLICATIONS For installation on potable water lines Protects against back siphonage and back pressure Maximum protection in Low Hazard conditions (Single Detector Check Valve) and in Medium Hazard conditions (Double Detector Check Valve) in fire sprinkler systems Metered by-pass to detect unauthorised water use and leaks Single Detector Check Valve with Metered By-Pass Flanged or Roll Grooved Product Code Description Length of Device (mm) SDC80YV 80mm SDC with 20mm Metered By-Pass 470 SDC100YV 100mm SDC with 25mm Metered By-Pass 470 SDC150YV 150mm SDC with 25mm Metered By-Pass 578 SDC200YV 200mm SDC with 25mm Metered By-Pass 851 Single Detector Check Valve with Spacer By-Pass Flanged or Roll Grooved Product Code Description Length of Device (mm) SDC80SE/CW 80mm SDC with 20mm Spacer By-Pass 470 SDC100SE/CW 100mm SDC with 25mm Spacer By-Pass 470 SDC150SE/CW 150mm SDC with 25mm Spacer By-Pass 578 SDC200SE/CW 200mm SDC with 25mm Spacer By-Pass 851 Single Testable Check Valve Flanged or Roll Grooved Product Code Description Length of Device (mm) STCV80 80mm STCV Testable with Test Points 470 STCV100 100mm STCV Testable with Test Points 470 STCV150 150mm STCV Testable with Test Points 578 STCV200 200mm STCV Testable with Test Points 851 Double Detector Check Valve with Metered By-Pass Flanged or Roll Grooved Product Code Description Length of Device (mm) DDCV65/20 65mm DDCV with 20mm Metered By-Pass 470 DDCV80/20 80mm DDCV with 20mm Metered By-Pass 470 DDCV100/20 100mm DDCV with 20mm Metered By-Pass 470 DDCV150/20 150mm DDCV with 20mm Metered By-Pass 578

AS/NZS 2845.1 Lic: WM 74542 FEATURES AND BENEFITS Single Detector Check Valve: 80mm-200mm size options available with 20mm and 25mm metered or spacer by-pass Double Detector Check Valve: 65mm-150mm size options with 20mm metered by-pass Shorter lay lengths Fewer parts needed save money Servicing ability and commissioning is easy, simple and cost effective Entire valve can be fully serviced inline lightweight short lay length modular design makes this valve easy and quick to service Pipe Connections: Flanged and Grooved connections Epoxy coated ductile iron construction Ease of access means lower maintenance costs saving time and money Noryl Replacement check valves 300 series stainless steel springs Max. working pressure: 1200 kpa Max. working temperature: 60 C Hydrostatic Test Pressure: 2400 kpa INSTALLATION Install device as per AS3500 and any local applicable codes and manufacturer s instructions. SPECIFICATION SAMPLE The MAG-BEECO Single/Double Detector Check Valve backflow preventer shall be WaterMark approved rated at le Detector 60 C. Check The main Valve body Specification shall be epoxy Sheet coated ductile iron construction with Noryl replaceable check valves. del SDC (3-8 ) The Single/Double Detector Check Valve shall be MAG-BEECO. Flomatic Corporation FLOW CHARACTERISTICS P R E S S U R E L O S S kpa M/W C psi 69 7 10 55 5.6 8 42 4.2 6 28 2.8 4 FLOW CURVES 3" (80mm) 4" (100mm) 6" (150mm) 14 1.4 2 TYPICAL INSTALLATION 0 350 700 1050 1400 1750 2100 gpm 79.49 158.97 238.45 317.94 397.43 476.91 M /H 22.08 44.17 66.26 88.34 110.43 132.51 lps FLOW RATE 3 DC Single Detector Check Valve Backflow ters should be installed with adequate clearance sy accessibility for testing and maintenance and protected from freezing. Local codes shall installation requirements. Unless otherwise d, the assembly shall be mounted at a minimum ce of 12 (305mm) between port and floor or The assembly shall have a maximum of 30 ) above adequate drains with sufficient side ce for testing and maintenance. The installation made so that no part of the unit can be ged. Thermal water expansion can cause ive pressure. Excessive pressure situations be eliminated to avoid possible damage to the Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 ½ 75 112 149 224 3 115 173 230 346 4 198 298 397 595 6 450 675 900 1351 8 780 1169 1559 2339 Design is for illustrative purposes.

In Wall Backflow Tundish - Single or Dual Assembly MAG purpose made tundishes with Beeco s Reduced Pressure Zone Backflow Device for maximum protection in high hazard applications. Single or Dual configurations in Stainless Steel Cabinets. APPLICATIONS For installation on potable water lines Protects against back siphonage and back pressure Maximum protection in High Hazard applications Configuration: Single or Dual Suitable for hot and cold water FEATURES AND BENEFITS Cover available as either lockable Perspex front cover with key lock or solid stainless steel cover Cabinet: Stainless Steel Fully assembled, pre-plumbed with RPZD Body, Barrel Unions, Y Strainer and Ball Valves Sizes: 15mm to 50mm single and dual assemblies (above 32mm is custom built enclosure) RPZs fully serviceable inline Test points from top of backflow device Noryl Replacement check valves Maximum working pressure: 1200 kpa Maximum working temperature: 82 C Hydrostatic test pressure: 2400kPa INSTALLATION Unless otherwise specified, install device at a minimum of 300mm above adequate drain with sufficient clearance for testing and maintenance. Note: Illustrated dimensions apply only to 15mm, 20mm and 25mm assemblies. SPECIFICATION SAMPLE The Backflow in Wall Tundish assembly shall be WaterMark approved rated at 82 C. The Tundish cabinet shall be stainless steel. The main RPZs shall be all brass construction with easily replaceable check valves. The assembly shall be MAG-BEECO. Figure 1- Flow Rates FRP-0.50LF, FRP0.75LF and FRP1.00LF

AS/NZS 2845.1 Lic: WM 74542 Product Code / Model Dual RPZ Assembly Product Code / Model Single RPZ Assembly MAG/IBT15/D 15mm Dual hot and cold MAG/IBT15/S 15mm Single hot and cold MAG/IBT20/D 20mm Dual hot and cold MAG/IBT20/S 20mm Single hot and cold MAG/IBT25/D 25mm Dual hot and cold MAG/IBT25/S 25mm Single hot and cold MAG/IBT32/D 32mm Dual hot and cold MAG/IBT32/S 32mm Single hot and cold MAG/IBT40/D 40mm Dual hot and cold MAG/IBT40/S 40mm Single hot and cold MAG/IBT50/D 50mm Dual hot and cold MAG/IBT50/S 50mm Single hot and cold MAG BACKFLOW INWALL CABINET With Hot & Cold RPZ Valves ISOLATION VALVE TEST COCKS ISOLATION VALVE WATER INLET WATER OUTLET ISOLATION VALVE WATER INLET 900 WATER OUTLET TEST COCKS ISOLATION VALVE Y STRAINER 90 Note: - Pre plumbed - Clear Lockable Viewing Panel - Full Stainless Steel Panel Available - Sizes available: 15-32mm (above 32mm is custom built enclosure) - Pressure loss: 49kPa - Depth: 90mm 100 430 65

Reduced Pressure Zone Device (RPZs) - 15mm-50mm Testable High Hazard Designed with ease of access in mind and with very few spare parts needed, the modular design makes MAG-BEECO valves the easiest and quickest valve to perform your mandatory yearly recertification on. APPLICATIONS For installation on potable water lines Protects against back siphonage and back pressure Maximum protection in High Hazard applications FEATURES AND BENEFITS Fewer parts needed save money Servicing ability and commissioning is easy, simple and cost effective Easy Repair: Checks are designed with a unique thumb screw holding in the disc to allow for easy removal with a simple pair of pliers dramatically reducing part breakage during repair Ease of access means lower maintenance costs saving time and money Single threaded cover enables quick access inside the valve Repair parts are modular - only takes two relief valve kits and three check repair kits to cover all sizes Entire valve can be fully serviced inline lightweight short lay length modular design makes valve easy and quick to service Sizes: 15mm to 50mm device Body: Brass Noryl Replacement check valves Relief valve port independent of check valves Maximum working pressure: 1200kPa Maximum working temperature: 82 C Hydrostatic test pressure: 2400kPa 300 series stainless steel springs INSTALLATION Unless otherwise specified, install device at a minimum of 300mm above adequate drain with sufficient clearance for testing and maintenance. SPECIFICATION SAMPLE The RPZD shall be WaterMark approved rated at 82 C. The main body shall be all brass construction with Noryl replaceable check valves. The RPZD shall be MAG-BEECO.

AS/NZS 2845.1 Lic: WM 74542 Reduced Pressure Zone Device Model Dimensions MAG Product Code Valve Size mm A (Device only) B (Device, Y Strainer and 2 Ball Valves) Device Only With Y Strainer and 2 Ball Valves FRP-0.50LF - 15mm RPZ Device 15mm 169 346 B9315 B9315C FRP-0.75LF - 20mm RPZ Device 20mm 169 346 B9320 B9320C FRP-1.00LF - 25mm RPZ Device 25mm 201 413 B9325 B9325C FRP-1.25LF - 32mm RPZ Device 32mm 230 488 B9332 B9332C FRP-1.50LF - 40mm RPZ Device 40mm 228 516 B9340 B9340C FRP-2.00LF - 50mm RPZ Device 50mm 272 615 B9350 B9350C Figure 1 - Flow Rates FRP-0.50LF, FRP-0.75LF and FRP-1.00LF Figure 2- Flow Rates FRP-1.25LF, FRP-1.50LF and FRP-2.00LF

Reduced Pressure Zone Device (RPZs) - 65mm-250mm Testable High Hazard Designed with ease of access in mind and with very few spare parts needed, the modular design makes MAG-BEECO valves the easiest and quickest valve to perform your mandatory yearly recertification on. APPLICATIONS For installation on potable water lines Protects against back siphonage and back pressure Maximum protection in High Hazard applications FEATURES AND BENEFITS Shorter lay lengths Fewer parts needed save money Servicing ability and commissioning is easy, simple and cost effective Single threaded cover enables quick access inside the valve Ease of access means lower maintenance costs saving time and money Repair parts are modular - only takes two relief valve kits and three check repair kits to cover all sizes Entire valve can be fully serviced inline lightweight short lay length modular design makes this valve easy and quick to service Epoxy coated ductile iron construction Noryl Replacement check valves Relief valve port independent of check valves Maximum working pressure: 1200kPa Maximum working temperature: 60 C Hydrostatic test pressure: 2400kPa 300 series stainless steel springs Figure 1- Flow Rates FRP-2.50LF, FRP-3.00LF and FRP-4.00LF INSTALLATION Unless otherwise specified, install device at a minimum of 300mm above adequate drain with sufficient clearance for testing and maintenance. Figure 2- Flow Rates FRP-6.00LF, FRP-8.00LF and FRP-10.00LF SPECIFICATION SAMPLE The RPZD shall be WaterMark approved rated at 60 C. The main body shall be epoxy coated ductile iron construction with Noryl replaceable check valves. Both checks 1st and 2nd shall be accessible for maintenance without removing the device from the system. The RPZD shall be MAG-BEECO.

AS/NZS 2845.1 Lic: WM 74542 Reduced Pressure Zone Device Model Dimensions MAG Product Code FRP-2.50LF - 65mm RPZ Device FRP-3.00LF - 80mm RPZ Device FRP-4.00LF - 100mm RPZ Device FRP-6.00LF - 150mm RPZ Device FRP-8.00LF - 200mm RPZ Device FRP-10.00LF - 250mm RPZ Device Valve Size mm A (Device only) B (Strainer) C (Device, Y Strainer and 2 Butterfly Valves) C1 (Device, Y Strainer and 2 Gate Valves) Flange Type Number of Holes Device Only With Butterfly Valves and Y Strainer With Gate Valves and Y Strainer 65mm 470 290 852 1140 Table D 4 B9265 B9265C B9265GVS 80mm 470 320 882 1196 Table D 4 B9280 B9280C B9280GVS 100mm 470 380 954 1308 Table E 8 B92100 B92100C B92100GVS 150mm 578 570 1210 1632 Table E 8 B92150 B92150C B92150GVS 200mm 851 600 1573 2035 Table E 8 B92200 B92200C B92200GVS 250mm 851 730 1744 2241 Table E 12 B92250 B92250C B92250GVS Easy One-Clamp Access Design Easily Maintained Strong Durable Internal Checks Easily Repairable Seat & Diaphragm Easily Repairable Seat & Diaphragm Relief Valve is located at the bottom of the body when installed vertically. This ensures that all water will drain from the body.

Double Check Valve (DCVs) - 20mm-50mm Testable Medium Hazard Designed with ease of access in mind and with very few spare parts needed, the modular design makes MAG-BEECO valves the easiest and quickest valve to perform your mandatory yearly recertification on. APPLICATIONS For installation on potable water lines Protects against back siphonage and back pressure Maximum protection in Medium Hazard applications FEATURES AND BENEFITS Fewer parts needed save money Servicing ability and commissioning is easy, simple and cost effective Easy Repair: Checks are designed with a unique thumb screw holding in the disc to allow for easy removal with a simple pair of pliers dramatically reducing part breakage during repair Ease of access means lower maintenance costs saving time and money Entire valve can be fully serviced inline lightweight short lay length modular design makes this valve easy and quick to service Single threaded cover enables quick access inside the valve Repair parts are modular - only takes two relief valve kits and three check repair kits to cover all sizes Sizes: 20mm to 50mm Body: Brass Noryl TM Replacement check valves Relief valve port independent of check valves Maximum working pressure: 1200kPa Maximum working temperature: 82 C Hydrostatic test pressure: 2400kPa 300 series stainless steel springs INSTALLATION Install device as per AS3500 and any local applicable codes and manufacturer s instructions. SPECIFICATION SAMPLE The Double Check Valve backflow preventer shall be WaterMark approved rated at 82 C. The main body shall be all brass construction with Noryl replaceable check valves. Both checks 1st and 2nd shall be accessible for maintenance without removing the device from the system. The DCV shall be MAG-BEECO.

AS/NZS 2845.1 Lic: WM 74542 Double Check Valve Model Dimensions MAG Product Code Valve Size mm A (Device only) B (Device, Y Strainer and 2 Ball Valves) Device Only With 2 Ball Valves and Strainer FDC-0.75LF - 20mm DCV Device 20mm 169 346 B9120 B9120C FDC-1.00LF - 25mm DCV Device 25mm 201 413 B9125 B9125C FDC-1.25LF - 32mm DCV Device 32mm 230 488 B9132 B9132C FDC-1.50LF - 40mm DCV Device 40mm 228 516 B9140 B9140C FDC-2.00LF - 50mm DCV Device 50mm 272 615 B9150 B9150C Figure 1 - Flow Rate FDC-0.75LF and FDC-1.00LF Figure 2 - Flow Rates FDC-1.25LF, FDC-1.50LF and FDC-2.00LF

Double Check Valve (DCVs) - 65mm-250mm Testable Medium Hazard Designed with ease of access in mind and with very few spare parts needed, the modular design makes MAG-BEECO valves the easiest and quickest valve to perform your mandatory yearly recertification on. APPLICATIONS For installation on potable water lines Protects against back siphonage and back pressure Maximum protection in Medium Hazard applications FEATURES AND BENEFITS Shorter lay lengths Fewer parts needed save money Servicing ability and commissioning is easy, simple and cost effective Epoxy coated ductile iron construction Ease of access means lower maintenance costs saving time and money Single threaded cover enables quick access inside the valve Entire valve can be fully serviced inline lightweight short lay length modular design makes this valve easy and quick to service Repair parts are modular - only takes two relief valve kits and three check repair kits to cover all sizes Noryl TM Replacement check valves Relief valve port independent of check valves Maximum working pressure: 1200kPa Maximum working temperature: 60 C Hydrostatic test pressure: 2400kPa 300 series stainless steel springs INSTALLATION Install device as per AS3500 and any local applicable codes and manufacturer s instructions. SPECIFICATION SAMPLE The Double Check Valve backflow preventer shall be WaterMark approved rated at 60 C. The main body shall be epoxy coated ductile iron construction with Noryl replaceable check valves. Both checks 1st and 2nd shall be accessible for maintenance without removing the device from the system. The DCV shall be MAG-BEECO.

AS/NZS 2845.1 Lic: WM 74542 Double Check Valve Model Dimensions MAG Product Code FDC-2.50LF - 65mm DCV Device FDC-3.00LF - 80mm DCV Device FDC-4.00LF - 100mm DCV Device FDC-6.00LF - 150mm DCV Device FDC-8.00LF - 200mm DCV Device FDC-10.00LF - 250mm DCV Device Valve Size mm A (Device only) B (Strainer) C (Device, Strainer and 2 Butterfly Valves) C1 (Device, Strainer and 2 Gate Valves) Flange Type Number of Holes Device Only With Butterfly Valves and Strainer With Gate Valves and Strainer 65mm 470 290 852 1140 Table D 4 B9165 B9165C B9165GVS 80mm 470 320 882 1196 Table D 4 B9180 B9180C B9180GVS 100mm 470 380 954 1308 Table E 8 B91100 B91100C B91100GVS 150mm 578 570 1210 1632 Table E 8 B91150 B1150C B91150GVS 200mm 851 600 1573 2035 Table E 8 B91200 B91200C B91200GVS 250mm 851 730 1744 2241 Table E 12 B91250 B91250C B91250GVS Figure 1 - Flow Rates FDC-2.50LF and FDC-3.00LF Figure 2 - Flow Rates FDC-4.00LF Figure 3 - Flow Rates FDC-6.00LF, FDC-8.00LF and FDC-10.00LF

Reduced Pressure Zone Components Reduced Pressure Zone (2 1/2-10 ) Test Cock Lid Lid Clamp Lid Gasket Check Retainers Second Check Valve First Check Valve Epoxy Coated Ductile Iron Body Pressure Relief Valve Check Valve (2 1/2-10 ) Disk Seat Stem Stem O-Ring Bolts Washer Seat O-Ring Spring Diaphragm Piston Piston O-RIng Relief Valve (2 1/2-10 ) Nut Spring Check O-Ring Seat Bolt Disk Washer Disk Holder

Reduced Pressure Zone Components Reduced Pressure Zone (1/2-2 ) Test Cock Lid Lid O-Ring First Check Valve Plastic Spacer S Second Check Valve Ball Valve Cast Bronze Body Relief Valve Relief Check Valve Check Valve (1/2-2 ) Spring Disk Cap Screw Check Valve Body Check Valve Disc Retainer Check Valve O-Ring Check Valve Base Relief Valve (1/2-2 ) Seat Sub-Assembly Screw Stem Piston Seat O-Ring Spring Disc Diaphragm Piston O-Ring