Wilkins Safety Group

Similar documents
Electrical safety and you

Monitor and Review. Electrical Safety. Causeway Coast and Glens Borough Council HSPD 009

This expansion of responsibility for electrical safety was brought about by the Electricity at Work Regulations 1989 (EAWR).

Element C8.3 Installation, Use and Inspection of Electrical Systems

SAFETY FACT SHEETS. Electrical Hazards Safety Non Negotiable. G-HS-ST Electrical Hazards. G-HS-FS Version:1

INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT

Operating procedures relating to the use of electrical equipment and installations

Electrical test equipment for use on low voltage electrical systems

The Management of Electrical Safety in Quarries, Associated Plant and Equipment

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Electrical Safety Part II

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

28W WORK LAMP Model: CTL28 Part No:

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

2. All electrical items covered by Portable Appliance Testing must be tested on a regular basis by a certified competent person.

Guidance for Low Voltage Electrical Installations

OPERATION & MAINTENANCE INSTRUCTIONS

AVOIDING ELECTROCUTION HAZARDS

Books. Code of Practice for In-Service Inspection and Testing of Electrical Equipment (3rd edition) By IET Publication

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

OPERATION & MAINTENANCE INSTRUCTIONS

part three electrical installations

SPECIFICATION FOR. MAINTENANCE OF POWERED LIFTING PLATFORMS (for use by disabled persons)

OPERATION & MAINTENANCE INSTRUCTIONS

Bore Hole Pump Model Nos: CBB75 CBB100 Part Nos:

OPERATION & MAINTENANCE INSTRUCTIONS

ELECTRO SCIENCE CLUB BASIC ELECTRICAL SAFETY. Sanjay Srivastava,TGT(WE)

OPERATING & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

EARTHING YOUR QUESTIONS ANSWERED

FINAL-ER 42 Electrician Regulations Answer Schedule

Car Battery Charger Instructions for Use

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

SUBMERSIBLE PUMP HSE RANGE

SUBMERSIBLE PUMP HSE RANGE

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

PORTABLE ELECTRICAL EQUIPMENT SAFE OPERATING PROCEDURE

Electrical Awareness for Construction Activities. Overhead Power Lines & Underground Cables

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

SUBMERSIBLE DIRTY WATER PUMP

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET

ORIGINAL INSTRUCTIONS

Contents. 1 Introduction. 2. Advisory and Information Systems. 3. Supply. 3.1 Quality of Electric Supply. 3.2 Interference with other Customers

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

12 amp RMS Battery Charger

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

MAINTENANCE AND TESTING OF PORTABLE ELECTRICAL EQUIPMENT, RCDS AND TOOLS CS-OHS-33

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

18TH EDITION BS7671 HOW THIS AFFECTS YOU. BITESIZE II. wylexreasons.co.uk WHY CHOOSE ANYTHING LESS?

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Electrical safety on small construction sites

Cordless Rechargeable Saw Instructions for Use

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION

SAFE USE AND HANDLING OF HOSES AND FLEXIBLE CONNECTIONS IN THE SOLVENTS INDUSTRY

LEAD ACID BATTERY CHARGER

SUBMERSIBLE PUMP. Model No: HIPPO 2 OPERATING & MAINTENANCE INSTRUCTIONS

Electrical Safety Part I

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

SUBMERSIBLE WATER PUMP

The Impact of the 18 th edition (BS 7671:2018)

18V CORDLESS DRILL MODEL NO: CON18LiC

Unrestricted. S.Mukhopadhyay

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

CFT24 &CFT230 PART NOS:

"ELECTRICAL SAFETY IN THE LABORATORY"

Applications of Electrical Machines

SUBMERSIBLE WATER PUMP

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

Fault Finding. Standard/Fundamental Faults

Ordinary Level Physics SOLUTIONS: EFFECTS OF AN ELECTRIC CURRENT

ELECTRICAL GROUNDING SAFETY PROGRAM

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

1.Safe testing IMPORTANT:

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

9. Effects of an electric current

ELECTRICIAN S THEORY EXAMINATION 19 June 2010 QUESTION AND ANSWER BOOKLET

ELECTRICAL. 60 Minutes

RMT1201. ORIGINAL INSTRUCTIONS Cordless Multi-Tool

BSS Examination Checking Procedures Part 3 - Electrical systems Recommendations for change May 2012

1/2 HP SUMP PUMP OWNER'S MANUAL

SUBMERSIBLE WATER PUMPS

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

RPS1215 ORIGINAL INSTRUCTIONS. Cordless Pruner

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

Low Voltage Power Supplies in Electrified Areas

Boardworks Ltd Mains Electricity

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

EST Electrical Service Technician Answer Schedule

Safelift Overhead Runway Beams & Rolling Beam Cranes

Electrical Safety Program

National Grid UK Electricity Transmission plc. NATIONAL SAFETY INSTRUCTION and Guidance

Transcription:

H & S Guidance - Electricity INTRODUCTION Each year there are almost 1000 reportable accidents at work due to contact with electricity including a significant number of fatalities (about 20 a year). Even non-fatal shocks can cause severe and permanent injury or lead to other accidents (e.g. falls from ladders). Almost all workplaces are subject to the Electricity at Work Regulations 1989 which require duty holders to take precautions against the risk of death or personal injury from electricity in work activities WHAT ARE THE HAZARDS? Contact with live parts causing shock and burns Fires arising from faults Ignition of potentially flammable or explosive atmospheres The risk of injury from electricity depends on where and how it is used. For example, risks are greatest:- In wet surroundings Out of doors (includes greater risk of damage) In cramped conditions with a lot of earthed metalwork Where flexible/extension leads are used REDUCING THE RISK OF INJURY Ensure the electrical installation is safe:- New installations of fixed systems or the maintenance of existing fixed systems (where appropriate) should be to a suitable standard, e.g. BS7671 Requirements for electrical installations, or the current edition of the Institution of Electrical Engineers Regulations for Electrical Installations (the IEE Wiring Regulations). The IEE Wiring Regulations are non-statutory regulations and are a code of practice widely recognised and accepted in the UK. Compliance with them is likely to achieve compliance with relevant aspects of the Electricity at Work Regulations 1989. Provide enough socket outlets.

Provide safe and suitable equipment 1. Choose suitable equipment 2. Use of alternative power source (e.g. air tools) 3. Maintenance, which may involve a combination of the following:- User checks - of cables, plugs, joints, cable clamps, general condition and appearance. Formal visual inspection - by a competent person; may involve removal of plug cover to check fuse, cord grip, cable termination etc. but does not involve taking equipment apart. Combined inspection and test - requiring a wider degree of competency; checks are for loss of earth integrity, correct polarity and fusing, cable termination and suitability of equipment. NB The frequency of checking/inspection and testing will be influenced by the risk assessment, which will take into account such factors as:- working environment if hand-held manufacturers recommendations frequency of use likelihood of abuse previous maintenance history It is recommended that all reports are kept and used as a management tool to help control electrical safety. Accessible and identified emergency cut-off (isolation) switch near each fixed machine. Suitable protection for electrical equipment in flammable/explosive atmospheres. Reduce the Voltage - e.g. Temporary lighting at 12, 25, 50 or 110 volts Battery operated tools 110 V centre-tapped-to-earth portable tools

Provide a safety device - such as a residual current device (RCD) with a sensitivity of not more than 30 milliamps (ma). An RCD is a device that detects some, but not all, faults in the electrical system and rapidly switches off the supply. The best place for an RCD is built into the main switchboard or socket outlet, but a plug-in RCD can be used as a least-preferred option. Remember to operate or check the operation of the test button regularly. Work safely - following established safe systems of work and ensuring appropriate level(s) of competency. Remember the hidden dangers from underground power cables and the particular hazards of overhead power lines. PARTICULAR ELECTRICAL SAFETY ISSUES FLEXIBLE LEADS, PLUGS AND SOCKETS Defective leads, plugs and sockets cause more accidents than their appliances. Safety considerations include the following: Cables & cords If moved only occasionally consider fixed cabling. Ensure insulation and protection of cable is appropriate. Ensure adequate strength/support if needs to be suspended. Joints:- better to replace cable that to make a repair; if repaired, use a cable coupler with the 'connector' part on the supply side. Insulating tape should never be used. Extension leads preferred to long cable attached to the apparatus; reels to have notice of maximum safe current when coiled and to be fully unwound if above this. Flexing damage - usually where the cable enters the apparatus at the cord grip. Sheath damage (e.g. floor polishing machines). Adaptors-Use of adaptors is not recommended due to increases in mechanical stresses and the potential for electrical overload. Cord Grips-Failure to grip cable may result in the earth conductor becoming loose near to the live terminal or metalwork of the fuse (and fuse carrier) resulting in metalwork becoming live.

Children-Where access by children may be likely, shutters/covers etc. could be fitted to socket outlets or connectors. CABLE JOINTS AND REPAIRS Proprietary joints and cable connectors should be used which incorporate terminals or compression fittings suitable for stranded conductors, cable clamps and sleeving. Open-type connectors have disadvantages and should be discouraged. ELECTRICAL DISPLAYS Lighting or electrical display safety involves consideration of the following: Staff competency (limits stipulated in writing) Layout - recommended to be in accordance with IEE Regs, RCD protection, subdivision of large displays each with its own circuit, isolation and protective device(s). Connections - properly constructed; cord grips Adjustments - utilise switched sockets or lighting tracks; disconnect/ isolate and lock off prior to work. Routine inspection/testing. Domestic appliances - in addition to the above the larger power needs will necessitate a domestic type ring main with the addition of suitable lockable isolation facilities. ELECTRICAL SAFETY AT PLACES OF ENTERTAINMENT Guidance Note GS50 (Electrical safety at places of entertainment) gives useful guidance under headings, which include the following:- Risks Managing electrical safety Preventing electrical danger Power supplies and power distribution (fixed installations, generators, 110-125 volt supplies) Equipment (general, lighting systems, sound systems, maintenance)

Leaflet IND(G)247 Electrical Safety for Entertainers gives advice to entertainers who use electrical equipment for sound, lighting or other effects. The main precautions recommended are:- Maintenance, inspection, testing and repairs should only be carried out by someone who is suitably qualified and/or experienced, such as an electrician. Always ensure/check that other people s equipment is in a safe condition or properly connected - never assume this. Always use compatible equipment. Use a residual current device on the power supply to instruments and equipment. These are best located at the main switchboard or at the socket outlet but if these are not provided, an RCD fitted plug or RCD adapter is better than nothing. Ensure good earth connections with sound equipment (either double insulated or correctly fitted with a protective (safety) earth). Correct use of suitable transformers if using American equipment (110-125 volts). It is strongly recommended that a competent person (e.g. an electrician) is an always consulted. CHECKLIST - ELECTRICITY Have you considered the possibility of injury from electrocution, electric shock, heat, radiation or uncontrolled fire arising from the use of electricity? YES/NO Have you identified what electrical systems and equipment are within your control? YES/NO Have you informed, instructed and trained your staff to an appropriate level regarding the provisions of the Electricity at Work Regulations 1989? YES/NO Have you policies and procedures that define personal responsibilities and competencies regarding electricity? YES/NO Do you ensure that the fixed electrical system is checked periodically? (The IEE Regs recommend every 5 years). YES/NO

Do you have a system in place for purchasing, using and maintaining all portable and transportable electrical appliances? YES/NO Does it include 'user' checks? YESNO Does it include 'formal visual inspections'? YESNO Does it include 'combined inspection and testing' if necessary? YES/NO Are written records/registers/maintenance logs kept? YES/NO Are employees trained etc. in the hazards, risks and precautions of using electricity and your procedures for preventing danger? YES/NO REFERENCES/FURTHER DETAILS 1. Booklet HS (G) 85 Electricity at Work - Safe Working Practices HSE. ISBN 0 7176 0442X 2. Booklet HS(G) 107 Maintaining portable and transportable electrical equipment HSE. ISBN 0 7176 0715 1 3. Leaflet IND(G) 236 Maintaining portable electrical equipment in offices and other low risk environments. HSE. www.hse.gov.uk/pubns/indg236.pdf 4. Leaflet IND (G) 237 Maintaining portable electrical equipment in hotels and tourist accommodation. HSE. www.hse.gov.uk/pubns/indg237.pdf 5. Guidance Note GS38 - Electrical test equipment for use by electricians. HSE. ISBN 0 7176 0845 X 6. Guidance Note PM29 - Electrical hazards from steam/water pressure cleaners etc. (HSE). ISBN 0 7176 0813 1. 7. Guidance Note PM38 - Selection and use of electrical hand lamps. HSE. ISBN 0 11 886360 6. 8. Leaflet IND(G)231 - Electrical Safety and You. HSE.ISBN 0 7176 1207 4. www.hse.gov.uk/pubns/indg231.pdf 9. The Electricity at Work Regulations 1989 - an open learning course. HSE. ISBN 0 11 885443 7 10. Booklet HS(G) 118 - Electrical Safety in Arc Welding. HSE. ISBN 0 7176 0704 6

11. Leaflet - Electricity at Work Regulations 1989: compliance for firms without electrical staff. (The Loss Prevention Council, 140 Aldersgate Street, London, EC1A 4HY). 12. Leaflet IND(G)247 - Electrical Safety for Entertainers (HSE) 13. Guidance Note GS50 - Electrical Safety at Places of Entertainment (HSE). ISBN 0 7176 1387 9. 14. CD ROM. Your guide to the essentials of electrical safety. (HSE). ISBN 0 7176 1714 9.