PMA 5. Pensky-Martens Flash Point Tester. ::: Volatility... Flammability

Similar documents
Instruments for Chemical and Petroleum Products. Flash Point

ADU 5. Automatic Distillation Unit

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Closed Cup Flash Point Tester

Callisto 100. Cold Filter Plugging Point Tester

ERAFLASH NEW! THE SAFE SIDE OF FLASHPOINT TESTING. One Flashpoint Tester for All Applications:

Stabinger Viscometer SVM 3001

Penetration. Test Methods

RSSOT New Standards ASTM D 7525 ASTM D 7545 ASTM D 7525 ASTM D Manufacturer since

Paragon Scientific Ltd Proficiency Testing Scheme Schedule

Low cost EDXRF elemental analyzer

Stabinger Viscometer Series. SVM Series

TESTING OF FUELS : FLASH AND FIRE POINT

Solution Sheet 1.

Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester 1

Flash Point Process Analyzer

Standard Test Methods for Flash-Point by Pensky-Martens Closed Cup Tester 1

Sulfur in Oil Analyzer

AVL Particle Measurement System Aviation

Types E2 and D2. Types Q and L. Including products with: Digital Precision Pressure Gauges

Portable TOC Analyser for Stack Emissions

Determination of flash point Pensky-Martens closed cup method

Cetane ID 510. Customer Presentation. Refining. Petrochemical

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Elemental Analysis Advanced

Product Profile. Laboratory instruments. for quality control, analysis and calibration. Fuels

Vertical Tensile Machine

Standard Test Method for Flash Point by Tag Closed Cup Tester 1

ISO 3679 INTERNATIONAL STANDARD. Determination of flash point Rapid equilibrium closed cup method

ASTM D Standard Specification for Biodiesel Fuel (B 100) Blend Stock for Distillate Fuels

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Multi-Parameter Certified Reference Material

breakthrough versatility

Jet Fuel Conductivity Analysers & Additive Management systems

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

DEPARTMENT OF CHEMICAL ENGINEERING University of Engineering & Technology, Lahore. Energy Engineering Lab

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Digimar 816 CL. Versatile. User-friendly operation... The measuring program... Precise measuring results...

SCOPE OF ACCREDITATION

TSHR 7000 series TN-TS-TX analyzer

PETROLEUM TESTING EQUIPMENT N-WISSEN 2016

A Tradition of Competence

For reliable control of small, large or multi-system-type lubrication systems

Process Analyzer. Flash Point Analyzer Model P-500. Credible Solutions for the Oil and Gas Industry

SVM Stabinger Viscometer. ::: Viscometry at its best

L U B R I C A N T S & MATERIALS

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

Vapor Pressure Measurement Of Gasoline, Crude Oil & LPG With New ASTM D5191 & D5188 Speed Test

Main Roads Technical Standard

ElvaX Sulfur in Oil analyzer

Precision Thermometers for Material Testing

PowerView PV380-R2 Mechanical Configuration


SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

FPA4 DATASHEET JUNHO 2013

MiniLab EL Series for High Performance Engine Development and Maintenance

Electromagnetic Flowmeters. Product Overview.

CERTIFICATE OF ACCREDITATION

Semi-hermetic reciprocating compressors

MODULAR MELT FLOW: The First Step: Melt Flow Index (Weight Method) According to ASTM D 1238, ISO 1133 Method A and other equivalents

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

D-2 Incorporated. JF-1A-RC RampCheck Product Brochure. Part Number: JF-1A-RC Revision Date: 09/11/15 Drawing Number: R6

Products for Asphalt Testing

Standard Test Method for Flash Point by Modified Continuously Closed Cup (MCCCFP) Tester 1

Analysis of biodiesel oil (as per ASTM D6751 & EN 14214) using the Agilent 5100 SVDV ICP-OES

On-Line NIR Analysis for Blending

SINPAR FTC Combination Research and Motor Method Octane Rating Unit

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

TSHR 6000 series TN/TS/TX analyzer

IROX 2000 IROX DIESEL

Exceeding Expectations

On-Line NIR Analysis of Crude Distillation Unit

Flampunktsbestämning Sluten degel med jämviktsmetod (ISO 1523:2002) Determination of flash-point Closed cup equilibrium method (ISO 1523:2002)

ERAVAP NEW! VAPOR PRESSURE TESTING AT ITS BEST. One Vapor Pressure Tester for All Applications:

Options. 1 Test Station, Type ZT V/50Hz V/60Hz V/60Hz V/60Hz

Excellence Level. Excellence XSR Balances Discover Efficiency in Daily Weighing

Q200. Aquamax FlashPoint. Q5800 MiniLab 53 MiniLab 153 MicroLab Q1000. Q100 Spectroil M. Q300/310 Q3000 Pat 940 Density 5

BRAKE TESTER DECELEROMETER

Standard Test Method for Freezing Point of Aviation Fuels (Automated Optical Method) 1

Detailed Mid-FTIR Analysis Of Gasoline, Diesel & Jet Fuel With A Single Portable Analyzer In Seconds

MESA-7220 Multi-Element Analyzer Using EDXRF Technology

Temperature multi-function calibrator Model CTM

Refrigerated incubator with Peltier technology

MESA-7220 Measurement of Sulfur, Chlorine and other elements in Petroleum Products Using Mono-chromatic, Polarized EDXRF Analysis

Model Name: 4 Position RPV-1

Project Reference No.: 40S_B_MTECH_007

ERWEKA 8 ELNOVA ZT30 ZT40 ZT50 ZT60 ZT70 _!! disintegration testers ZT 20. If* h» L i J. Handelsgesellschaft mbh ERWEKA

A unique density, viscosity sensor. High technology brick. Field oriented. For light & medium petroleum products. Related norms

Zirconia Oxygen Probe

Climate chambers with illumination

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Mineral Turpentine Adulterant in Lubricating Oil

Simulated Distillation Analyzers, Software, Standards, Consumables, Training

Crude Oil and E&P Testing Laboratory Instruments for quality control, analysis and calibration

FREQUENTLY ASKED QUESTIONS (FAQs)

Pipe gasket range. Designed to make a difference. Designed to make a difference 1

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Tests conducted under the following industry standards for PermaFrost API ASHRAE ARI ASTM EPA ANSI UL. SINCE 1985 Quality Controlled Through Analysis

High Accuracy Bunker Blending / Bunker Control

Battery-Powered Flow Transmitter

Transcription:

PMA 5 Pensky-Martens Flash Point Tester ::: Volatility... Flammability

A Tradition of Competence 140 years of developing, producing and supporting excellent flammability instruments. 140 years of technology lie between the first flash point tester and today s Anton Paar product line of flammability measuring instruments. Mr. Berthold Pensky developed the first closedcup flash point tester and set a milestone for the production of flash point testers based on quality and precision. Aligned to the requirements of varying industrial branches the instruments from Berlin could meet a worldwide demand. The acquisition of Petrotest by Anton Paar combines the spirit of research and inventive talent with the advantages of a worldwide, well-established sales and service team. Founded in 1922, Anton Paar today employs over 2000 people in 20 countries who manage a global business and provide the whole value chain, starting from product ideas, research and development, production, sales, application support and after-sales services. As a result of this unique concentration of talents and know-how, Anton Paar's product portfolio has grown continuously. It now covers a wide range of laboratory instruments, process technologies and automation systems, ranging from standardized QC to complex R&D solutions. Anton Paar is close to you and your work. An experienced local team speaks your language and provides application support and training. Anton Paar thinks globally and acts locally.

Flash Point Measurement All methods all standards one product line Anton Paar has the suitable flammability tester for each type of measuring task in its product line. Tests according to 4 standardized methods in the temperature range of -30 C to 400 C are possible to cover a wide range of applications. This includes: the petrochemical field, calibration and regulation authorities, transportation and shipping, engineering, waste management and the cosmetics and food industries. Cleveland method open-cup determination for expected flash and fire points in the range of 79 C to 400 C (175 F to 752 F). Pensky-Martens methods closed-cup determination for expected flash points in the range of 40 C to 400 C (104 F to 752 F). Comprising: Method A for distillate fuels (diesel, kerosene, heating oil, turbine fuels), new lubricating oils, paints, varnishes and other homogeneous liquids. Method B for residual fuel oils, cutback residual, used lubricating oils, non-homogeneous materials like mixtures of petroleum liquids and solids, surface-film-building petroleum liquids or liquids with a viscosity above 5.5 cst at 40 C. Method C for biodiesel (FAME). Requires electronic flash point detection! Pensky-Martens closed-cup (PMCC). PMA 5 is standardized for both biodiesel and biodiesel blended fuels along with such distillate fuels as diesel, heating oil and kerosene and such potentially flammable liquids as lubricating oils, paints and varnishes. Product highlights are: ``One-Twist head ``Multi-detector ``Integrated fire-extinguishing device ``Gas and electric ignition ``1-button operation ``Tray For standardized, comfortable, versatile and safe flash point testing the PMA 5 Pensky-Martens tester is the right choice! Tag method closed-cup determination for expected flash points below 93 C (200 F). Abel method closed-cup determination for expected flash points in the range of -30 C to 70 C (-22 F to 158 F).

PMA 5 Make Work Easy and Safe Patented error-free connection The One-Twist patented swivel-around multi-functionhead guarantees the safe and easy one-hand connection of all sensors and actuators such as the shutter actuator, stirrer, igniter and detector contacts. It reduces the set-up time after a sample change and assures comfortable and error-free handling. Immersion depth to perfection The multi-detector combines the flash point detector and the temperature probe in a solid housing with a perfectly adjusted immersion depth. Available with glass or stainless steel temperature probe and officially certified. Neatness at work A tray to hold cup/lid, sensor and igniters when out of use. Small dishes collect the sample remains. This keeps your workspace clean and prevents damage to sensitive parts.

Choice of ignition The PMA 5 allows the use of an electric or gas igniter. If working with the gas ignition, the electric igniter is used as an auxiliary ignition to ensure the uninterrupted burning of the test flame. If necessary it relights the flame during the test automatically. Being independent of a gas source allows more mobility and extends the application range. Fire hazard reduced to zero The integrated fire-extinguishing system is automatically controlled or can be released manually. Flames that might occur outside the cup will be extinguished by nitrogen or carbon dioxide gas. Turn, click and push The Pmove jog wheel has a scroll function (by turning the jog shuttle), 4 cursor keys (the button is moved in the direction of the illuminated arrow) and an <ENTER> function (by pressing the button). With this comfortable program operation you can input e.g. test parameters, sample name and program selection, even with protective gloves on.

Versatility by Options Software FPPNet This optional software allows a computer connection for direct control and real-time monitoring of the test progress. It is a convenient solution for test data evaluation and documentation. Further, it simplifies firmware updates and the export of test results. On-site calibration The calibration set PMA/PM is a mandatory accessory for the PMA 5 calibration programs. It is used to calibrate the sample Pt100 dynamically against certified thermometers. The on-site calibration feature is very cost-effective and available at any time. Multi-detector functionality check The holding device for multi-detectors (PMA and ABA/TAG) allows you to check the functionality of your Pt100 and thermo-couple and enables calibration services to calibrate the Pt100. The diagnosis function of the sensitive sensors prevents unnecessary service costs in case of unexpected measurements. Small-scale samples The test insert ppm for small sample volumes between 2 ml to 15 ml extends the application of the PMA 5 for small sample quantities. A reduced sample volume of 80 % is valuable for the cosmetics industry and also the R&D field. Versatility by stainless steel The test insert PM-NIRO is a stainless steel alternative to the 75 ml standard type made of brass. Our multi-detector PM-NIRO combines the flash point detector with a sturdy stainless steel temperature probe. Not in compliance with official standards it extends the spectrum of samples.

Specifications Flash point determination The temperature in non-equilibrium methods is increased slowly over a given range with the source of ignition being presented to the vapor at intervals until the flash is observed. The flash point is the lowest temperature, corrected to a barometric pressure of 101.3 kpa, at which application of an ignition source causes the vapors of a specimen of the sample to ignite under specified conditions of the test. Standard methods Pensky-Martens methods for petroleum products: ASTM D93 A+B+C, ISO 2719 A+B, ISO 15267, JIS K 2265-3, IP 34 A+B, GOST R EN ISO 2719 Technical specifications Test programs ASTM D93 (A+B+C) ISO 2719 (A+B) JIS 2265-3 (A+B) Search A+B (ASTM+ISO) Search Run Rapid Bitumen ppm (Milli-PM, 5 ml to 15 ml sample) 15 individually designable test programs Operation Temperature range up to 405 C Ignition type Gas and electric Stirring speed According to standard method or user-defined Heating rate According to standard method or user-defined Cooling Built-in forced air Barometric pressure Flash point is automatically corrected to barometric pressure correction Detection Test place Safety Calibration Handling Thermal/eliminates interferences from water 1 (standardized test insert with multi-detector included) ``Overheat protection, automatic shut-off ``Automated fire-extinguishing system ``A potential-free alarm relay contact is also available from the PMA 5 to a fire suppression or remote alarm system ``Password protection ``Self-made Pt100 sample-temperature-probe calibration, against certified a liquid-in-glass ASTM thermometer ``Pt100 sample-temperature-probe correction using up to 21 user-defined temperature points from the external calibration certificate ``Heater-block-Pt100 calibration ``Barometric-pressure-sensor calibration ``Splash-proof membrane key panel with color display ``Jog shuttle with LED indication for input of test parameters, sample name and program selection ``Selection of C or F, as well as further test parameters ``Multi-language user support (English, German, French) ``Progress of test displayed in different colors (user-defined) ``The jog shuttle and 4 softkeys underneath the display are used for operation Documentation Memory 1000 tests, 20 operator names and 100 samples Statistics Mean, Min, Max, Repeatability Interfaces 3x USB, 1x RS232, 1x LAN Input options Optional keyboard and bar code reader Display 5.7'' QVGA color; real-time measurement displayed Requirements and dimensions Electrical supply 115/230 V, 50/60 Hz Gas supply Test flame: 50 mbar of propane or butane Fire extinguisher: 6 bar to 12 bar of nitrogen or carbon dioxide Dimensions 230 mm x 410 mm x 460 mm (W x D x H) Weight net 14 kg

Subject to change without notice 07/14 H03IP001EN-D