ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

Similar documents
UTM10 Series Ultrasonic Transit-time Flowmeters

MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd.

digital flow meters BW Digi-Meter F-1000

Range of Ultrasonic Flowmeters.

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

Model DFX Doppler ultrasonic flow meter

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

Appendix. Clearance. Skewed profiles. Application Schematics

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

Armstrong In-Line and Insertion Vortex Flow Meters

F-2600 SERIES INLINE VORTEX FLOW METER

MICRO-FLO MICRO-FLO. Digital Paddlewheel Flow meter Operating Manual. Blue-White. Industries, Ltd.

Low Profile Insertion Vortex

Distributed by: M&M Control Service, Inc MICRO-FLO MICRO-FLO

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Model FVP General Specification. Flanged Vortex Plate. Product Features

ISTEC MAGNETIC METERS

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

NC State University Design and Construction Guidelines Division 23 Energy Management

Dissolved Oxygen Measurement System with Air Blast Cleaner

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

Hot Tap Insertion Vortex

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

Time Delta S Fixed Transit-Time Flow Meter System

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Vortex Plate. Model VP General Specification. Product Features

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

ULTRAFLO 2000 ULTRASONIC LIQUID FLOW AND HEAT/ENERGY METERS FOR PERMANENT INSTALLATION HIGH TEMPERATURE SENSORS AS STANDARD

Multivariable Vortex Flow Meter

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Model 1000 Vortex Meter

FLEX-PRO. Peristaltic Metering Pump. SERIES A3V and A4V. Operating Manual. ProSeries. by Blue-White Ind.

VALVES & ACTUATORS. 20th TECHNOLOGY REPORT. SOLUTIONS for FLUID MOVEMENT, MEASUREMENT & CONTAINMENT. HOW MUCH PRESSURE Can a 150 lb. Flange Withstand?

ThermoPro TM Series TP10

DIGIFLO ELECTRONIC FLOWMETER

F-2600 SERIES INLINE VORTEX FLOW METER

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Distributed by: M&M Control Service, Inc

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Model 5000 Vortex Meter

VIM20 Vortex Insertion Flowmeter

Model Q45H/ Residual Chlorine Monitor...

NCM-603 Hand Held Clamp-on Ultrasonic Transit Time Flowmeter

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

imag 4700 SERIES FLANGED MAGMETER

VIM20 Vortex Insertion Flowmeter

INDEX. Introduction. Introduction. Sensor Mounting. Keypad System. Battery. Menu System. Error/Warning Messages. Troubleshooting guide

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

USER'S GUIDE Installation & Operation Instructions Portable Doppler Flow Meter Model PF D550 Manual Series A.1.

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

USER'S GUIDE Installation & Operation Instructions Slurry Flow Meter Model SFM 6.1 Manual Series A.1.1

USER'S GUIDE. Installation & Operation Instructions. Portable Doppler Flow Meter Model PDFM 5.0 Manual Series A.1.5

CHEM-FEED. Engineered Skid Systems. ProSeries. by Blue-White Ind.

flow x3 flow monitoring

Compu-Flow. Electromagnetic Insertion Flow Meter. Compu-Flow EXM MAG

Multivariable Vortex Flow Meter

F-1500 SERIES INSERTION TURBINE FLOW METER

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Vortex In Line Flow Meter

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

EASZ-10P Operating Instructions

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Vortex Eggs Delta Flowmeter

RIM20 Rotor Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter

F-2500 SERIES VORTEX METER

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Hydro-Flow Model 2200 Installation and Operation Guide B

Hand held ultrasonic flow meter

RCM - Direct Reading Flowmeters

Turbidity and Suspended Solids Transmitter

TABLE OF CONTENTS Service Information 2 Quick Start Instructions 4-5 Introduction 6 Specifications 6 Controls and Terminology

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

The readings you need, right where you need them. AX Series Vortex Meters

INSTRUMENTATION & CONTROL

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

CONTROLLERS & SPECIAL VALVES

FLEX-PRO TM PERISTALTIC PUMPS

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

Electromagnetic Flowmeters. Product Overview.

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

The readings you need, right where you need them. AX Series Vortex Meters

THYRO-PX SERIES DIGITAL THYRISTOR SCR POWER CONTROLLER UP TO 2900 AMPS

VORTEX IN-LINE FLOW METERS

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Vortex In Line Flow Meter

SIGNET 7002 Vortex Flow Sensor ENGLISH

TRANSIT TIME FLOW METERS

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

Ultra Mag SUBMITTAL PACKAGE

USER'S GUIDE Installation & Operation Instructions Portable Doppler Flow Meter Model PDFM 5.0 Manual Series A.1.9

Hydro-Flow Model 2300 Installation and Operation Guide B

Transcription:

ProSeries by Blue-White Industries, Ind. Ltd. Industries, Ltd. s SNIC-PR s SNIC-PR s S4 Transit Time Ultrasonic Flowmeter ½ thru 2 diameter Pipe Sizes Inline spool piece Advanced communications Data logging Process control relays 4-20mA and pulse outputs NEMA 4X (IP 66) washdown enclosure 2 Year warranty Liquid applications Model S4X1CX020DG NEMA 4X Applications:! Ultra-Pure Water! Wastewater! Ground water! Food and Beverage Features:! Ultrasonic Transit Time operation.! Inline spool piece pipe fitting for easy installation.! Non-intrusive, transducers do not touch the fluid.! Special low power mode permits battery operation (limited features).! High quality backlit LCD.! Data logging to internal memory. User configurable to time interval, flow rate and total set-point triggers. 190,000 events can be downloaded to flash drive via USB.! Isolated 4-20 ma output - fully configurable.! 0-1000Hz Pulse output - fully configurable.! Process control functions via two independently configurable 1 amp, form C relays. Configure to flow rate for high/low/range rate alarm or to flow total for either manual trigger batch operations or flow triggered batch operations.! ptional communications include Industrial Ethernet, Modbus RTU, Modbus TCP, PRFIBUS DPV1, and PRFINET.

Specifications: General peration Measuring Principle Ultrasonic - Transit Time. Fluid Types Water to 5% (0 to 50,000 ppm) particulate. Fluid Velocity Range 0.5 to 30 feet per second (0.15 to 9 meters per second) Nominal Pipe Sizes 0.50, 0.75, 1.00, 1.50 and 2 inch IPS pipe sizes Accuracy +/-2% of rate > 1 ft/sec, +/-0.10 ft/sec < 1 ft/sec Inline Pipe Fitting/ Transducer Pipe Fitting/Transducer NEMA 4X (IP66), High Density Polyethylene Connection option A - High Density Polyethylene, Female NPT threads Maximum fluid temperature: 14 F to 160 F (-10 C to 71 C) Maximum operating pressure: Connection option B - 316 Stainless Steel, Female NPT threads Maximum fluid temperature: 14 F to 160 F (-10 C to 71 C) Maximum operating pressure: Connection option C - PVC, Female Slip Maximum fluid temperature: 14 F to 140 F (-10 C to 60 C) Maximum operating pressure: Connection option D - 300 PSI/g at 70 F 300 PSI/g at 70 F 300 PSI/g at 70 F 316 Stainless Steel, 150# Flat Face Flange (without gaskets) Maximum fluid temperature: 14 F to 160 F (-10 C to 71 C) Maximum operating pressure: 300 PSI/g at 70 F Cable - field replaceable Shielded coaxial RG/U Type: 59. FEP jacket, black. RoHS Compliant Connector: thermoplastic locking. NEMA 4X (IP66) Available lengths: 10ft (3m), 25 ft. (7m), 50 ft. (15m), 100 ft. (30m) TEMPERATURE F (C) 160 F ( 71 C) 150 F ( 65 C) 140 F ( 60 C) 130 F ( 54 C) 120 F ( 49 C) 110 F ( 43 C) 100 F ( 38 C) 90 F ( 32 C) 80 F ( 27 C) INLINE PIPE FITTING TEMPERATURE VS PRESSURE PVC Adapters HDPE and 316SS Adapters 70 F ( 21 C) 0 50 100 150 200 250 WRKING PRESSURE (PSI/g) 300 SPU (Signal Processing Unit) Enclosure NEMA 4X (IP66), Powder coated aluminum, SS clamps and hardware. Dimensions: 7.24H x 6.69W x 3.11D inches (184H x 170W x 79D mm) Weight 3.7 lb. (1.7 Kg.) Mounting Pipe fitting, wall or pipe (vertical or horizontal) mounting. Hardware included. Power Requirements 15-28 VDC; 15 watts maximum perating Temperature 14 F to 140 F (-10 C to 60 C) Storage: -40 F to 158 F (-40 C to 70 C) Display VGA backlit LCD, UV resistant. Simultaneous Rate and Total: 8 digit maximum Decimal location configurable to 5 places. Display Language English Keypad Six-button positive action tactile switch keypad. Security Programmable 4-digit password. Display Volume Units Independently configurable Rate and Total display units in: U.S. Gallons, ounces, barrels (US liquid), barrels (US oil), cubic ft, acre ft, Imperial (British) gallons, liter, cubic meter, or user defined custom units. Rate display in feet or meters per second. Display Time Units Seconds, minutes, hours, days. Display/utput Response Time 1.0 second. Flow Rate Display Averaging Selectable: 0.50, 1.0, 2.5, 5.0 (default), 10.0 seconds. Data utputs! Isolated 4-20 ma output - fully configurable, invertible! 0-1000 Hz Pulse output - fully configurable, invertible Data Logging Date/time stamped flow rate and flow total data in FAT32 file format, easily imported into Excel. Configurable to trigger on time interval (1-999,999 sec), rate and/or total set-point values. Store up to 191,800 log events in the memory buffer, downloadable to flash memory via USB port. Process Control Two independently configurable relays. Type: FRM C Load capacity: 30V, 100mA max (ext. supplied)! Configure to flow rate for high/low/range rate alarm. Programmable release values enable auto release or manual latching operation.! Configure to flow total for automatically triggered, timed batch operations for proportional feed applications. External Communications Computer connection via optional Communications Modules:! Industrial Ethernet/IP! Modbus RTU! Modbus TCP! Profinet RT/I! Profibus DPV1 When equipped with a communications module, the following data transfer is possible: 1. Flow rate 2. Flow total 3. Fault/warning codes 4. Log data 5. CC1 relay status 6. CC2 relay status 7. Current fluid sound speed 8. Number of Goodness of Measurement boxes filled in 9. Analog output value (4-20 ma) 10. Frequency output value (0-1000 Hz) 11. Firmware version 2 of 6

Dimensions: 6.69 in 170 mm 3.11 in 79 mm Sonic-Pro SPU 8.00 in 203 mm.35 in 9 mm 6.52 in 166 mm 7.24 in 184 mm 6.23 in 158 mm 1.24 in 31 mm.58 in 15 mm.81 in 21 mm.70 in 18 mm 6.52 in 166 mm 1.50 in 38 mm TYP..86 in 22 mm 3.14 in 80 mm 3.2 in 81 mm 2.5 in 64 mm 15.36in 39.0cm Sonic-Pro Inline Pipe Fittings 12.78in 32.45cm W E D L A L B C W Pipe Size 2" 1.5" 1".75".5" L W A B C 7.47in [18.97cm] Flanged Fittings 8.02in [20.38cm] 7.35in [18.68cm] 6.76in [17.18cm] 6.45in [16.45cm] 6.20in [15.75cm] 1.94in [4.93cm] 1.50in [3.81cm].96in [2.45cm].74in [1.88cm].55in [1.39cm] 4.75in [12.07cm] 3.88in [9.86cm] 3.12in [7.92cm] 2.38in [6.05cm] 6.00in [15.24cm] 5.00in [12.70cm] 4.25in [10.80cm] 3.88in [9.86cm] 3.50iin [8.89cm] Pipe Size 2" 1.5" 1".75".5" L W D E NPT Fittings 6.97in [17.71cm] 6.53in [16.59cm] 5.98in [15.18cm] 5.90in [14.97cm] 5.83in [14.80cm] 1.94in [4.93cm] 1.50in [3.81cm].96in [2.45cm].74in [1.88cm].55in [1.39cm] 3.90in [9.91cm] 3.33in [8.45cm] 3 of 6

Installation: Fluid Requirements The Sonic-Pro series S4 Ultrasonic Flow Meter can measure fluid flow in water. The Sonic-Pro S4 meter measures fluid flow using the Transit Time method. The Sonic-Pro S4 ultrasonic sound transducers are factory positioned for water. They do not touch the process fluid and there are no moving parts. This method of flow measurement is safe, non-intrusive and very easy to service. To enable the sound waves to complete their circuit, the Transit Time measuring method requires relatively clean water. The maximum amount of particles should not exceed 0% to 5% (0 to 50,000 ppm). Water that contains low concentrations of other chemicals, such as 5% sodium hypochlorite, may be acceptable provided the chemical does not change the speed that sound travels through the fluid more than approximately +/- 100 m/sec. The transducers are factory adjusted for a fluid with a sound speed of 1500 meters per second +/- 100 m/sec. Minimum Straight Pipe Length Requirements The Sonic-Pro s sound wave beam is only affected by fluid that actually passes through the beam and therefore, the meter will not measure with high accuracy if the fluid velocity is not consistent across the entire pipe diameter. Flow disturbances such as pumps, elbows, tees, and valves in the flow stream can cause swirl patterns and vortices that will affect the measurement accuracy or disrupt flow measurement capability. Install the transducers on a straight run of pipe as far as possible from any disturbances. The distance required for high accuracy will depend on the type of disturbance. Flange Reducer Type of Disturbance o 90 Elbow o Two 90 Elbows - 1 Direction o Two 90 Elbows - 2 Directions Gate valve or Pump Straight Lengths of Pipe Required Upstream from Transducers Downstream from Transducers 5 x Nominal Pipe Size 5 x Nominal Pipe Size 7 x Nominal Pipe Size 5 x Nominal Pipe Size 10 x Nominal Pipe Size 5 x Nominal Pipe Size 15 x Nominal Pipe Size 5 x Nominal Pipe Size 20 x Nominal Pipe Size 5 x Nominal Pipe Size 25 x Nominal Pipe Size 5 x Nominal Pipe Size Transducer Mounting Location! The meter can be mounted on horizontal or vertical runs of pipe.! Mounting anywhere around the diameter of vertical pipe is acceptable, however, the pipe must be completely full of fluid at all times.! Back pressure is required on downward flows to ensure a full pipe.! See the minimum straight length of pipe requirement chart above. N Pipe must be full N Air could be trapped K Down flows must have back pressure! K K L >= 10D L >= 5D See minimum straight length requirements above 4 of 6

Display: All Sonic-Pro S4 models allows full access to the configuration menus directly from the front panel. Display VGA backlit LCD displays flow rate, accumulated flow total, Goodness f Measurement (GM) indication, measured fluid sound speed Display Language English Keypad SIx-button tactile switch keypad. Security Programmable 4-digit password. Display Volume Units Rate and Total display units in: U.S. Gallons, ounces, barrels (US liquid), barrels (US oil), cubic ft, acre ft, Imperial (British) gallons, liter, cubic meter, or user defined custom units. Rate display in feet or meters per second. Display Time Units Seconds, minutes, hours, days. utput Signals: All Sonic-Pro S4 models include both a 4-20mA analog and a 0-1000 Hz frequency output signal that is user configurable. Communications ptions: Any S4 model can be equipped with any one of the following optional Communications Modules:! Industrial Ethernet/IP! Modbus RTU! Modbus TCP! Profinet RT/I! Profibus DPV1 When equipped with a communications module, the following data transfer is possible: 1. Flow rate 2. Flow total 3. Fault/warning codes 4. Log data 5. CC1 relay status 6. CC2 relay status 7. Current SS 8. Number of Goodness of Measurement boxes filled in 9. Analog output value (4-20 ma) 10. Frequency output value (0-1000 Hz) 11. Firmware virsion Data Logging: All Sonic-Pro S4 models include data logging to a USB memory stick. Each log entry includes: date/time, flow rate value, flow total value, and error codes in FAT32 file format easily imported into Excel. Configurable to trigger on time interval (1-999,999 sec), rate and/or total set-point values. Store up to 191,800 log entries in the memory buffer and download to an external flash memory via USB port. Process Control: All Sonic-Pro S4 models include two contact closure relays for rate and total flow volume alarms. Each relay is can be configured to respond to changes in either the measured rate of flow or the accumulated total flow value. When assigned to monitor flow rate, high/low/range rate alarms are possible. When assigned to monitor accumulated total, automatically triggered, timed batch (proportional feed) operations are possible. Type: FRM C. Load: 30V, 100mA max (ext. supplied) 5 of 6

Model Number Matrix: Sonic-Pro S4 Part Number Matrix Signal Processing Unit (SPU) - Display S4 Sonic-Pro Base model Communications ptions D Industrial Ethernet/IP E Modbus RTU F Modbus TCP/IP G PRFINET RT/I H PRFIBUS-DPV1 X Standard 4-20mA and High Speed Pulse output only Input Power (15-30 VDC required - all units include D cell battery pack, 4 D cell batteries are not included) 0 Without power supply (customer supplies 15-30 VDC) 1 U.S. 115VAC~50/60 / 15VDC plug-in transformer 2 Europe 220VAC~50/60 / 15VDC plug-in transformer 3 U.S. 230VAC~50/60 / 15VDC plug-in transformer Inline Pipe Fitting/Transducer C Inline pipe fitting/transducer (see pipe size and material options below) X Without inline pipe fitting/transducer Transducer Cable Length and Connection Type A 10 ft cable length - with field replaceable liquid-tight cable plug and socket B 25 ft cable length - with field replaceable liquid-tight cable plug and socket C 50 ft cable length - with field replaceable liquid-tight cable plug and socket D 100 ft cable length - with field replaceable liquid-tight cable plug and socket X Display mounted directly on the inline pipe fitting/transducer - no transducer cables Z Inline pipe fitting transducer only (no display) - without cables Inline Pipe Fitting/Transducer Fluid Sound Speed Working Range 0 Water like fluids 1500 +/- 100 m/sec Nominal IPS Pipe Connection Size 05 1/2 07 3/4 10 1 15 1-1/2 20 2 Pipe Connection Type and Material A F/NPT, HDPE B F/NPT, 316SS C Slip, PVC D Flange, 316SS Inline Body Material G Polyethylene (HDPE) S4 D 1 C A 0 07 A G Sample Part Number Inline Pipe/Transducer nly ST Sonic-Pro Transducer Transducer Model Transducer Cable Length and Connection Type Pipe Configuration Specifications ST - C - B - 015AG Sample Number Blue-WhiteR Industries, Ltd. 5300 Business Drive, Huntington Beach, CA 92649 Tel: 714-893-8529 Fax: 714-894-9492 www.blue-white.com Email: sales@blue-white.com 6 of 6