Installation Instructions 500 A Current Sensor Kit for D2h/D4h/D7h/D8h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Similar documents
Installation Instructions 300 A Current Sensor Kit for D1h/D3h/D5h/D6h Enclosure Sizes VLT Series FC 102, FC 103, FC 202, and FC 302

Installation Instructions 500 A Current Sensor Kit for F1 F4/F8 F13 Enclosure Sizes VLT Series FC 102, FC 202, and FC 302

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

Control Card VLT FC Series

Installation Instructions In-bottom/Out-back Cooling Kit for E4h Drives VLT FC Series FC 102, FC 103, FC 202, and FC 302

Installation Guide. VLT Real-time Clock MCB 117 VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202, VLT AutomationDrive

Installation Instructions In-back/Out-back Cooling Kit for D5h/D6h and D7h/D8h Enclosures VLT Series FC 102, FC 202, and FC 302

INSTRUCTIONS INSTALLATION OF LOAD-SHARE TERMINALS FOR VLT DRIVES

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Upgrading the Boxer LAD blower module

Marine Annex covering all VLT Drives Note

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Installation Instructions

5. Installation on Pedestal - IP 21 / IP 54 Units 43

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Section 1.0 Warnings Section 2.0. Section 3.0. Section 4.0. MCD3000 Inside Delta Connection Kits. Contents

Disassembling and assembling isave 21

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Changing pistons APP 21-43

Changing pistons APP and APP 16-22

INSTALLATION INSTRUCTIONS

RANGER 900 POWER STEERING KIT

INSTALLATION INSTRUCTIONS SEMI Hidden Kit Part Number: Application: Toyota Tacoma

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

INSTRUCTIONS 177R0076 INSTALLATION OF TOP AND BOTTOM COVERS FOR IP00 FRAMES D3, D4 & E2 INTO RITTAL ENCLOSURES

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

Disassembling and assembling PAH , PAHT and PAHT G

Altivar 61/71 Adjustable Speed Drives Plastic Kits and Power Terminal Kit

Installation Guide VLT Parallel Drive Modules

B-026INT October 6, 1999 FUEL FILTER BRACKET RETROFIT (JAPAN ONLY) GENERAL RETURN THIS TO: INITIAL HERE TECHNICIAN NO.

Appendix: Safety and application notes for... 15

The steering column is of a modular construction and features easy to service electrical switches.

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

850 TETHER SWITCH KIT

RCA PLUG KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

(1) Remote Control with (2) AAA Batteries

Q-Frame Main Circuit Breaker (225 A Maximum) and Adapter Kit Installation onto an NQ Panelboard Class 1640

GENUINE Interior Lighting Kit

HANDLEBAR BAG WITH PHONE CHARGER KIT

TYPE APPROVAL CERTIFICATE

TOYOTA YARIS XM SATELLITE RADIO Preparation (Sedan & Hatchback)

TOYOTA PRIUS XM SATELLITE RADIO Preparation

Agilent G1554A On-Column Capillary Inlet with EPC

Appendix: Safety and application notes for 19

Wiper motor bolt and spacer. 3. Place relays as shown in picture so you can route the wires.

This kit may void factory warranty please check with manufacturer.

3 Internal Frequency Converter Operation 43

Please visit for the latest version of these installation instructions.

Installation Guide. DEVIreg 527. Electronic Time Regulator.

INSTALLATION INSTRUCTIONS: P/N: / D

TYPE APPROVAL CERTIFICATE

Please visit for the latest version of these installation instructions.

E.S.P. Embedded Sensing Probes for Motor Brushes

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

Please call us at Mon-Fri 8am-5pm if you need any additional assistance.

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

Installation Instructions Part Number

INSTALLATION INSTRUCTIONS

Altivar 58 TRX Adjustable Speed Drive Controllers in Motor Control Centers hp, 480 V or 1 50 hp, 208/240 V Class 8998

- Wiring Brochure Universal Reset Module 422e

TOYOTA YARIS HATCHBACK INTERIOR LIGHT UPGRADE Preparation

REF QTY PART DESCRIPTION PART NUMBER

ACCESSORY KIT INSTALLATION INSTRUCTIONS Low Ambient Accessory For Air Cooled Split System Air Conditioners HB 180/240, HF -15,-20 Models Only

Installing the Boxer fan upgrade kit

Starting Torque Limiter Type TCI (Soft Start)

INSTALLATION INSTRUCTIONS FORD SUPER DUTY NOTE: (Vehicle Retains Tow Hook) PART # P3064

w w w. h d o n l i n e s h o p. d e CHROME FAN KIT GENERAL INSTALLATION -J04347 REV Kit Number Models Kit Contents

MOUNT KIT PERSONAL PLOW

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

SCION xb EC REARVIEW MIRROR Preparation

Altivar 61/71 Adjustable Speed Drives Spare Parts Kits

Installation Power Management Unit Battery Cables and Battery Harness

Please read BOTH these Installation Instructions and the General Instructions prior to installing or operating this equipment.

Floor heating system, heating circuit with FHV-A in flow.

TOYOTA Yaris Hatchback EC REARVIEW MIRROR Preparation

SCION xb AUTO-DIMMING MIRROR Preparation

ROUSH Active IO Exhaust. Installation Instructions P/N: (R LITE) Fastback GT Convertible GT V8

Installing the PBX-PIT01 or PBX-PIT05 Pit Bar in the Ford Police Interceptor Utility

MAKING MODERN LIVING POSSIBLE. Instruction Manual VLT AutomationDrive FC 300

PART NUMBER: H630SSJ000. Kit Contents: A. Amplifier with Bracket (1) D. Badge (2) with push nuts (4)

Ford 6.7 EGR Delete Kit

Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches

Installation Instructions

Avoid damage to the motorcycle. Protect painted surfaces with a soft cloth or blanket.

Instructions for 2-row monitoring only

CHROME ALLEY CAT L.E.D. FUEL & BATTERY GAUGE 7381

w w w. h d o n l i n e s h o p. d e HEATED HAND GRIP KITS GENERAL REMOVAL -J02983 REV Kit Number Models Kit numbers Service Parts

Installation manual portable distributors

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

2010+ Victory Cross Country / Cross Roads Installation Guide Nov 2014

Assisted lift operated 2/2-way solenoid valves Type EV251B

VW Shift Paddle Kit Installation Instructions

Premounted Midi Shunts

LOW, MID, HIGH RISE PRO-TAPER HANDLEBAR WITH HEATED GRIPS KIT

LED 3rd Brake Light Ring

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

Transcription:

Description The 500 A current sensor kit is designed for D2h/D4h/D7h/D8h enclosure sizes in the power ranges shown in Table 1.1. To identify the power rating, see Illustration 1.1. Product group and drive series VLT HVAC Drive FC 102, VLT Refrigeration Drive FC 103, VLT AQUA Drive FC 202 VLT AutomationDrive FC 302 Voltage rating Power rating [kw [V] (hp)] (T4) 380 480 200 315 (300 450) (T7) 525 690 200 400 (250 400) (T5) 380 500 200 250 (300 350) (T7) 525 690 160 315 (200 350) 1 Product group and drive series 2 Power rating 3 Voltage rating (phases and mains) Illustration 1.1 Nameplate Information for an FC 202 250 kw D2h Enclosure Table 1.1 Applicable Power Range for 500 A Current Sensor Kit This 500 A current sensor kit provides an upgraded current sensor and all the components required to retrofit the current sensor for an existing D2h, D4h, D7h, or D8h enclosure. For the kit parts list, refer to Illustration 1.4. Identifying the Power Rating To find the frequency converter power rating, use the following steps: 1. Obtain the following information from the nameplate, which is on the frequency converter. Refer to Illustration 1.1. Product group and drive series (characters 1 6) Power rating (characters 7 10) Voltage rating (phases and mains) (characters 11 12) Kit Part Numbers Part number 176F3737 Kit description Current sensor kit for D2h/D4h/D7h/D8h enclosure sizes Table 1.2 Part Number for the Current Sensor Kit Safety Instructions Only qualified personnel are allowed to install the parts described in these installation instructions. Make sure to read and save these instructions. 2. Determine if the power rating is in Table 1.1. Danfoss A/S 12/2015 All rights reserved. MI70V102

WARNING ELECTRICAL SHOCK HAZARD VLT frequency converters contain dangerous voltages when connected to mains voltage. Improper installation, and installing or servicing with power connected, can cause death, serious injury, or equipment failure. To avoid death, serious injury, or equipment failure: Only use qualified electricians for the installation. Disconnect the frequency converter from all power sources before installation or service. Treat the frequency converter as live whenever the mains voltage is connected. Follow the guidelines in these instructions and local electrical safety codes. WARNING DISCHARGE TIME The frequency converter contains DC-link capacitors, which can remain charged even when the unit is off. High voltage can be present even when the warning indicator lights are off. Failure to wait for a minimum of 20 minutes after power has been removed before performing service or repair work can result in death or serious injury. Removal Guidelines NOTICE The current sensor kit includes an extra set of fasteners in case any fasteners are missing or unusable. To make the disassembly/reassembly process easier, use these general guidelines: 1. Follow the removal instructions for each component. 2. Place the component along with the removed fasteners together in one place. 3. Replace old component with the new component provided in the kit. 4. If any fasteners are stripped or lost, replace with similar fastener from kit. 5. Follow the installation instructions to replace and secure each component. Removing AC Input Bus Bars This step differs based on the following installed options: 1. Stop the motor. 2. Disconnect AC mains and remote DC-link supplies, including battery back-ups, UPS, and DC-link connections to other frequency converters. 3. Disconnect or lock PM motor. 4. Wait 20 minutes for the capacitors to discharge. 5. Measure the voltage level to verify full discharge. 1 Nut (13 mm) 6 Mains input terminal 2 Brake bus bar optional 7 Fuse spacer 3 Motor terminal bus bar 8 Nut (13 mm) 4 Motor terminal block 9 Input power bus bar 5 Power terminal mounting plate Illustration 1.2 AC Input Bus Bars in Unit with Mains Fuses Option (Shown with Mains Fuses Removed) 2 Danfoss A/S 12/2015 All rights reserved. MI70V102

No options 1. Take off the air baffle by removing 4 screws (T25). 2. Remove 3 nuts (13 mm) at the top of the input bus bars, 1 per phase. 3. Remove 6 nuts (13 mm) at the bottom of the input bus bars, 2 per phase. 4. Remove the input bus bars. Mains fuses only NOTICE The current sensor kit does not include components included with this option. Reuse these components. 1. Take off the air baffle by removing 4 screws (T25). 2. Remove the 3 mains fuses by removing 6 nuts (13 mm), 1 at each end of each fuse. 3. Remove 3 nuts (13 mm) at the top of the bus bars, 1 per phase. 4. Remove the bus bars. RFI only NOTICE The current sensor kit does not include components included with this option. Reuse these components. 1. Take off the air baffle by removing 4 screws (T25). 2. Remove 3 nuts (13 mm) at the top of the RFI filter, 1 per bus phase. 3. Remove 6 nuts (13 mm) at the bottom of the RFI filter, 2 per phase. 4. Remove 4 mounting thread-cutting screws (T20) connecting the RFI filter to the side channels of the frequency converter. 5. Remove the RFI filter and unplug the RFI cable from the MK100 connector on the printed circuit board assembly. Each connector is labeled on the board. Fuses and RFI NOTICE The current sensor kit does not include components included with this option. Reuse these components. 1. Take off the air baffle by removing 4 screws (T25). 2. Remove mains fuses by removing 6 nuts (13 mm), 1 at each end of each fuse. 3. Remove 3 nuts (13 mm) at the top of the RFI filter, 1 per phase. 4. Remove 4 thread-cutting screws (T20) connecting the RFI filter to the side channels of the frequency converter. 5. Remove the RFI filter and unplug the RFI cable from MK100 on the printed circuit board assembly. Each connector is labeled on the board. MI70V102 Danfoss A/S 12/2015 All rights reserved. 3

Removing Input Terminal Block Removing Power Terminal Mounting Plate 1. Disconnect the customer input power wiring. 2. Remove the 2 screws (T25) at the bottom of the terminal block. 3. Free the current sensor wiring from the captive retaining clips. 4. To remove the terminal, slide the terminal down to disengage it from the metal clips holding it in place. Removing EMC Partition 1. Remove 1 screw (T20). 2. Remove the EMC shield. Removing Brake Terminal (optional) 1. Disconnect the customer brake wiring. 2. To detach the R (+) terminal, remove the 1 threadforming screw (T25) at the terminal block, and 1 additional screw (T40). 3. To detach the R (-) terminal, remove the 1 threadforming screw (T25) at the terminal block, and 1 additional nut (13 mm). 4. To detach the brake terminal block, remove 2 nuts (13 mm). 1 Power terminal mounting plate 5 Nut (8 mm) 2 Fan retaining screw 6 Thread-cutting screw (T25) 3 Mixing fan 7 Mixing fan cable 4 Current sensor cable routing Illustration 1.3 Power Terminal Mounting Plate Removing Output Terminal Block 1. Disconnect customer motor wiring. 2. To detach the U output bus bar, remove the 1 thread-forming screw (T25) in the center of the bus bar and the 1 bolt (T40) at the current sensor end. 3. To detach the V output bus bar, remove the 1 threadforming screw (T25) in the center of the bus bar and the 1 bolt (T40). 1. Remove the 5 thread-cutting screws (T25) from the top of the plate. The fan screw can remain in place. 2. Remove the 2 nuts (8 mm). 3. Remove the current sensor cables. 4. While pulling the plate up, unplug the mixing fan that is located under the mounting plate. 4. To detach the W output bus bar, remove the 1 thread-forming screw (T25) in the center of the bus bar and the 1 bolt (T40). 5. Remove the 3 current sensor cylinders. 6. Remove the 2 screws (T25) at the bottom of the terminal block. 7. To remove the terminal, slide the terminal down to disengage it from the metal clips holding it in place. 4 Danfoss A/S 12/2015 All rights reserved. MI70V102

Installing the Current Sensor Kit 1 Label, input 14 Motor bus bar, U 2 M10x30 machine screw with captive washer (Qty 6) 15 Motor bus bar, V 3 M10 nut (Qty 6) 16 Motor bus bar, W 4 Input/mains terminal block 17 M5x16 Torx screw (Qty 3) 5 M5x12 machine screw with captive washer (Qty 4) 18 Label, output 6 Output/motor terminal block 19 Partition with EMI shield 7 Mounting plate tab that secures the terminal blocks 20 Plastic fastener (Qty 3) 8 Power terminal mounting plate Qty: 1 (IP21/54), 1 (IP20) 21 Current sensor (Qty 3) 9 M5x12 machine screw with captive washer (Qty 6) 22 Mylar insulator (Qty 3) 10 M10 grounding nut with captive washer (Qty 4) 23 M4x10 thread-forming screw (Qty 6) 11 Bracket (Qty 2) 24 Multiple wire guide (Qty 6) 12 Mixing fan and housing assembly 25 M5x11 thread-cutting screw (Qty 6) 13 Bus bar insulation sleeve (Qty 1) Illustration 1.4 Exploded View and Parts List of 500 A Current Sensor Kit MI70V102 Danfoss A/S 12/2015 All rights reserved. 5

Installing Current Sensors Installing Power Terminal Mounting Plate NOTICE TERMINAL MOUNTING PLATE There are 2 mounting plates included in the kit (1 for IP20 and 1 for IP21/IP54). Use the one that fits your enclosure type. 1. Making sure that the arrows on the current sensor are pointing toward the front of the frequency converter, reinstall the 3 current sensors onto the power terminal mounting plate provided in the kit. Fasten securely using 2 thread-forming screws (M4x10) per sensor. Torque to 2.8 Nm (24 in-lb). 2. Connect the wire harness to the current sensors. 3. Insert 1 single wire guide and 1 multiple wire guide as shown in Illustration 1.5. 4. Run the wire harness through the wire guides. 1. Unplug the old wire harness from the power card and discard the harness. 2. Insert the power terminal mounting plate into the unit. To ease installation, insert the bottom of the plate near the bottom of the frequency converter. Secure the plate with 7 thread-cutting screws (M5x11). Torque to 1.7 Nm (15 in-lb). 3. Connect the top of the wire harness to the power card. See Illustration 1.6. 4. Connect the bottom of the wire harness to the mixing fan. 5. Insert the mixing fan into the fan housing, with the label facing the open side of the housing. 6. Push the fan wire connector to the left to make room for the fan assembly. With the fan label facing up, insert the mixing fan assembly into the plate opening. The fan assembly is level with the plate once properly seated. 7. To install the 2 brackets, place the slotted tab on the bottom of the bracket into the slots in the plate. Secure with 2 T25 machine screws from the old unit. 8. Install 4 ground nuts with captive washer (M10) onto the power terminal mounting plate. Torque to 19 Nm (169 in-lb). 1 Wire harness (current sensor) 5 Wire harness (fan) 2 Current sensor 6 Multiple wire guide 3 Power terminal mounting plate 7 Fan connector 4 Single wire guide Illustration 1.5 Wire Harness on Backside of the Power Terminal Mounting Plate 6 Danfoss A/S 12/2015 All rights reserved. MI70V102

1 Power card 6 Mixing fan 2 Power card connector to current sensor wire harness 7 Power card connector to RFI 3 Wire harness (current sensor) 8 Power card connector to fan wire harness 4 Current sensor 9 Wire harness (fan) 5 Power terminal mounting plate 10 Ground nuts Illustration 1.6 Installing Power Terminal Mounting Plate MI70V102 Danfoss A/S 12/2015 All rights reserved. 7

Installing Output Terminal Block Installing AC Input Bus Bars 1. Place the output terminal label (identified by U, V, W) above the terminal connections. See the removed output terminal block for the best label position. 2. Push the output terminal block up against the metal clips on the power terminal mounting plate until they engage. 3. Secure with 2 machine screws (M5x12) at the bottom of the terminal block. Torque to 2.3 Nm (20 in-lb). 4. Roll up the mylar insulator and insert it into the middle of each current sensor. 5. Insert the current sensor cylinder inside the mylar insulator. 6. Slide the insulation sleeve over the U-phase bus bar. 7. Attach the motor bus bars. Secure each bus bar with 1 Torx screw (M5x16) at the current sensor end and 1 thread-forming screw in the center of the bus bar. Torque the Torx screw to 2.3 Nm (20 in-lb) and the thread-forming screw to 4.0 Nm (35 in-lb). Installing Brake Terminal (optional) 1. Install the brake terminal block using 2 nuts (M8). Torque to 9.6 Nm (85 in-lb). 2. Install the R(-) terminal using 1 thread-forming screw (M4x10) at the terminal block, and 1 nut (M8). Torque the thread-forming screw to 2.8 Nm (24 in-lb) and the nut to 9.6 Nm (85 in-lb). 3. Install the R(+) terminal using 1 thread-forming screw (M4x10) at the terminal block, and 1 screw (T40). Torque the thread-forming screw to 2.8 Nm (24 in-lb) and the T40 screw to 9.6 Nm (85 in-lb). 4. Connect the customer brake wiring. Installing Partition with EMC Shield 1. Install the partition with EMC shield to the left of the motor terminal block. 2. Secure with 2 machine screws (M5x12). Torque to 2.3 Nm (20 in-lb). Installing Input Terminal Block 1. Place the input terminal label (identified by R, S, T) above the terminal connections. See the removed input terminal block for the best label position. 2. Push the input terminal block up against the metal clips on the power terminal mounting plate until they engage. 3. Secure with 2 machine screws (M5x12) at the bottom of the terminal block. Torque to 2.3 Nm (20 in-lb). The next step differs based on the following installed options: No options 1. Attach the bus bars. 2. Secure each bus bar with 1 nut (M8) at the top of the bus bar and 2 nuts (M8) at the bottom of the bus bar. Torque to 9.6 Nm (85 in-lb). Mains fuses only 1. Attach the bus bars. Secure each bus bar at the top with 1 nut (M8). Torque to 9.6 Nm (85 in-lb). 2. Install the mains fuses using 6 nuts (M8), 1 at each end of each fuse. Torque to 9.6 Nm (85 in-lb). RFI only 1. Connect the RFI cable from MK100 on the printed circuit board assembly to the RFI filter. 2. Attach the RFI filter to the side channels of the frequency converter with 4 thread-cutting screws (T20). Torque to 5.7 Nm (50 in-lb). 3. Secure the top of the RFI filter using 3 nuts (M8), 1 per phase. Torque to 9.6 Nm (85 in-lb). 4. Secure the bottom of the RFI filter using 6 nuts (M8), 2 per phase. Torque to 9.6 Nm (85 in-lb). Fuses and RFI 1. Connect the RFI cable from MK100 on the printed circuit board assembly to the RFI filter. 2. Attach the RFI filter to the side channels of the frequency converter with 4 thread-cutting screws (T20). Torque to 5.7 Nm (50 in-lb). 3. Secure the RFI filter using 3 nuts (M8) at the top of the RFI filter, 1 per phase. Torque to 9.6 Nm (85 inlb). 4. Install mains fuses using 6 nuts (M8), 1 at each end of each fuse. Torque to 9.6 Nm (85 in-lb). Reconnecting Customer Wiring 1. Reconnect the motor wiring to the U, V, and W terminals. 2. If a brake terminal is present, reconnect the customer brake wiring. 3. Reconnect the mains wiring to the R, S, and T terminals. 4. Install the air baffle using 4 screws (T25) and 2 nuts (M8). Torque to 2.3 Nm (20 in-lb). 8 Danfoss A/S 12/2015 All rights reserved. MI70V102

MI70V102 Danfoss A/S 12/2015 All rights reserved. 9

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss A/S Ulsnaes 1 DK-6300 Graasten vlt-drives.danfoss.com 130R0678 MI70V102 12/2015 *MI70V102*