TMA5 Mini Vane Anemometer

Similar documents
TACH-10 Contact / Non-Contact Tachometer

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

PY-11 Voltage & Continuity Tester

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

TIME-10 Process Control Stopwatch

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

THWD-5. Relative Humidity Temperature Meter. Users Manual. For detailed specifications and ordering info go to

THWD-3 and TH-3 Relative Humidity and Temperature Meters

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

KMP Insulation-Continuity Tester. Users Manual

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

INSP-3 Wiring Inspection Tester

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

CO2-100 CO2 Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

KMP7010. Ground Resistance Tester. Users Manual

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

TMD90A Dual Input Digital Thermometer

Operator s Manual TC-253A. Temperature Converter

362 Clamp Meter. Users Manual

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

323/324/325 Clamp Meter

365 Detachable Jaw True-rms Clamp Meter

Users Manual. Phase Rotation Indicator

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

302+/303 Clamp Meter. Users Manual

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

373 Clamp Meter. Users Manual

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

i3000s/i2000 Flex AC Current Probe

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Users Manual. Airflow Meter

233 True-rms Remote Display Digital Multimeter Safety Information

362 Clamp Meter. Users Manual

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING


Visit us at

Visit us at SOLAR-500. Solar Analyzer. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

User's Guide. CO 2 Meter. Model CO250

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

718 30G/100G. Users Manual. Pressure Calibrator. 99 Washington Street Melrose, MA Phone Toll Free

716 Pressure Calibrator

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

Infrared Thermocouple Probe

i400s Calibration Information Introduction

1000FLT. Users Manual. Fluorescent Light Tester

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

PK-8270-X/PK-8370-X. Lines and Fittings Kit. Instructions. Introduction. How to Contact Fluke Calibration

712 RTD Calibrator. Instruction Sheet. Introduction

Users Manual. MegOhmMeter

Go to to register your product and find more information.

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

PolyStat Immersion Circulators

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

User's Manual. Earth Ground Resistance Tester. Model Introduction

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

DT304. Digital Temperature Logger INSTRUCTION MANUAL

Electrostatic Fieldmeter

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

1KV DIGITAL MULTIFUNCTION INSULATION RESISTANCE AND CONTINUITY-VOLTAGE TESTER WITH MOV & GAS ARRESTER TESTING. Model 1154TMF

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Tachometer. English. Users Manual

VELOCICALC Air Velocity Meter

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Solar Power Light Meter

Thermo-Anenometer Model Owner s Manual

EM20 Digital Anemometer User Manual

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

SOIL RESISTIVITY TESTER

NOTES TABLE OF CONTENTS

OWNER S MANUAL CAMBRO CAMDUCTION COMPLETE HEAT CHARGER.

User Manual. CFM/CMM Vane Thermoanemometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

DP-CALC TM Micromanometer

DIGITAL EARTH RESISTANCE Model KM 2030

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

Defender 3000 Series Base Instruction Manual

HIGH VOLTAGE PROVING UNIT

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.


PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Model P772 Conductivity Meter. User Manual

KIT CONSISTS OF: FEATURES. S-Digit mini

Coating Thickness Gauges

Transcription:

TMA5 Mini Vane Anemometer Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com

TMA5 Mini Vane Anemometer Users Manual English October 2009, Rev.2 2009 Amprobe Test Tools. All rights reserved. Printed in China

Limited Warranty and Limitation of Liability Your Amprobe product will be free from defects in material and workmanship for 1 year from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Amprobe s behalf. To obtain service during the warranty period, return the product with proof of purchase to an authorized Amprobe Test Tools Service Center or to an Amprobe dealer or distributor. See Repair Section for details. THIS WARRANTY IS YOUR ONLY REMEDY. ALL OTHER WARRANTIES - WHETHER EXPRESS, IMPLIED OR STAUTORY - INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, ARE HEREBY DISCLAIMED. MANUFACTURER SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Repair All test tools returned for warranty or non-warranty repair or for calibration should be accompanied by the following: your name, company s name, address, telephone number, and proof of purchase. Additionally, please include a brief description of the problem or the service requested and include the test leads with the meter. Non-warranty repair or replacement charges should be remitted in the form of a check, a money order, credit card with expiration date, or a purchase order made payable to Amprobe Test Tools. In-Warranty Repairs and Replacement All Countries Please read the warranty statement and check your battery before requesting repair. During the warranty period any defective test tool can be returned to your Amprobe Test Tools distributor for an exchange for the same or like product.

Non-Warranty Repairs and Replacement US and Canada Non-warranty repairs in the United States and Canada should be sent to a Amprobe Test Tools Service Center. Call Amprobe Test Tools or inquire at your point of purchase for current repair and replacement rates.

TMA5 Mini Vane Anemometer 1 2 3 BFT/M/HKMHM/SKNT H MAXWBTDP % WCIEXT RH 4 5 8 6 9 7 1) Vane impeller 2) Precision thermister temp. sensor & capacitive humidity sensor 3) LCD display 4) POWER and HOLD key 5) UNIT and MODE key 6) Battery compartment (on rear side) 7) Wrist strap holder 8) TPK60 probe socket 9) TPK60 probe

5 6 4 BFT/M/HKMHM/SKNT H MAX WBTDP % WCIEXT RH 1 3 2 7 1) Air velocity unit 2) Primary LCD display: Air velocity, Air temperature, relative humidity, Windchill (WCI), Dew point temp.(dp), Wet bulb temp. (WBT), probe temp.(ext) in turns. 3) Unit of temperature. oc or of selectable 4) Max. velocity indicator 5) To freeze the latest display. 6) Low battery indicator 7) Humidity indicator and unit POWER / HOLD KEY: To turn on the meter Press more than 3 seconds to turn off the meter.e electricity waste and cost In normal mode, press to freeze the readings In power off mode, press more than 3 seconds to disable the auto sleep mode. + UNIT / MODE KEY: In normal mode, press to display different modes in turns: Velocity/Max. Velocity/Air Temp./Relative Humidity/Windchill/Dew Point Temp./Wet Bulb Temp./External Probe Temperature. In air velocity mode, press these two keys to change the air velocity unit. In any temperature mode, press these two keys to change the temperature unit.

TMA5 Mini Vane Anemometer CONTENTS SYMBOLS... 2 UNPACKING AND INSPECTION... 2 INTRODUCTION... 3 Features... 3 OPERATION... 3 Auto Power Off... 4 SPECIFICATION... 4 MAINTENANCE AND REPAIR... 6 Battery Replacement... 7 TROUBLE SHOOTING... 7 1

SYMBOLS W Caution! Refer to the explanation in this Manual ; Conforms to relevant Australian standards P = Complies with European Directives Do not dispose of this product as unsorted municipal waste. WWARNING and PRECAUTIONS The meter is accurate at low and mid-range air speeds. Consistent use at very high speed; i.e.: From the window of a fast-moving car will damage the impeller s bearing and cause inaccuracy. When you program the meter and then restart the meter, it will default to the last mode and unit used. You can remove the transparent protection film of the LCD if you feel the display is blurred. Unpacking and Inspection Your shipping carton should include: 1 TMA5 meter 1 TPK60 probe 1 CR2032 battery 1 Manual 1 Soft pouch 1 Wrist strap If any of the items are damaged or missing, return the complete package to the place of purchase for an exchange. 2

INTRODUCTION Congratulations on your purchase of TMA5 mini anemometer. A convenient instrument to measure air flow, temperature and humidity. Features Compact size design with a wrist strap Precision thermistor sensor & capacitive humidity sensor Easy two buttons operation Big display with 7 selectable units Data hold to freeze display External temperature probe included Auto power off Operation 1. Hold the meter and target the air source from the rear of the unit. When holding the meter, hold it at arm s length and away from your body. 2. Plug in the TPK60 probe if want to measure external temperature. 3. Press POWER/HOLD button to turn on the meter. 4. The top LCD indicates the unit of wind speed and the primary display indicates the value (Fig.1) 5. Press POWER/HOLD button to freeze the current reading. The H icon appear on LCD. Press again to release. (Fig.2) 6. Press UNIT/MODE button to switch the display from wind speed to max wind speed, air temperature, relative humidity, wind chill (WCI), Dew point temp. (DP), Wet bulb temp.(wbt) and probe temp.(ext) 3

7. To change velocity unit, press POWER/HOLD and UNIT/MODE simultaneously while in velocity mode. 8. To change temperature unit,press POWER/HOLD and UNIT/MODE simultaneously while in any temperature mode. 9. Turn off the meter by pressing POWER/HOLD button more than 3 seconds. 10. Unplug the probe and put back the anemometer into soft pouch to protect the vane impeller. Auto Power Off This instrument will shut off automatically in approx. 5 minutes of inactivity. For operating over longer period of time, disable the sleep mode by pressing POWER/HOLD more than 3 seconds before power on until a n appears in the middle of the screen (Fig.3) and then release key to return to the normal measurement mode. SPECIFICATIONS Velocity Range : 0.5~44.7M/H, 60~3937FT/M, 0.4~38.8KNT, 1.1~20.0M/S, 0.8~72.0KMH, 1~8BF Resolution :0.1M/H,2FT/M,0.1KNT,0.1M/S,0.1KMH,1BF Accuracy : +/-5% of reading or +/-last significant digit (whichever is greater) Air Temp. Range :0~50 C (32 F~122 F) Resolution : 0.1 C Accuracy : +/-1 C Humidity Range : 5~95%RH Resolution :0.1%RH 4

Accuracy : +3.5% RH (at 25 C,10~90%RH).others +5% Ext. Probe Range : -20~70 C (-4 F~162 F) Resolution : 0.1 C Accuracy : +/-1 C Dew Point Range : -20~59.9 C (-4 F~140 F) Wet Bulb Range : -5~59.9 C (23 F~140 F) Operation temp : 0~50 C Operation RH% : 0~80%RH Power Requirements : 1pcs 3V (Type: CR2032) Windspeed unit : M/S: meter per second, KMH: Kilometer per hour FT/M: Feet per minute KNT: Knot M/H: Mile per hour BF: Beaufort P - EMC: Conforms to EN61326-1. This product complies with requirements of the following European Community Directives: 89/ 336/ EEC (Electromagnetic Compatibility) and 73/ 23/ EEC (Low Voltage) as amended by 93/ 68/ EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading results when making measurements in the presence of electronic interference. 5

MAINTENACE AND REPAIR If there appears to be a malfunction during the operation of the meter, the following steps should be performed in order to isolate the cause of the problem. 1. Check the battery. Replace the battery immediately when the symbol appears on the LCD. 2. Review the operating instructions for possible mistakes in operating Except for the replacement of the battery, repair of the meter should be performed only by a factory Authorized Service Center or by other qualified instrument service personnel. The front panel and case can be cleaned with a mild solution of detergent and water. Apply sparingly with a soft cloth and allow to dry completely before using. do not use aromatic hydrocarbons or chlorinated solvents for cleaning. The meter is accurate at low and mid-range air speeds. Consistent use at very high speeds., ie, From the window of a fast-moving car will damage the impeller s bearing and cause in-accuracy. Battery Replacement Replace your batteries when low battery icon appear on LCD. To replace the battery: 1. Turn the battery compartment cover in a COUNTERCLOCKWISE direction to remove it. (Fig.4) 2. Put the new battery between two contact pins and battery anode side faces up. 3. Affix the battery compartment cover by turning it in a CLOCKWISE direction. 6

TROUBLE SHOOTING 1. Power on but no display a) Make sure the time of pressing power key is > 0.2 second. b) Check the batteries are in place with good contact and correct polarity. c) Replace battery or move away the battery for one minute and re-install. 2. Display disappear a) Replace a new battery. b) Disable the auto power off function before power on for long time using. 3. Error code E02: The value is under range E03: The value is over range E04: The original data error results in this error (RH, WCI, DP, WBT) E31: Circuit or sensor damaged 4. Wind speed reading is always zero The wind speed components or circuit is damaged. Sent back for repair 7

BF Fig.1 FT/M H Fig.2 Fig.3 Fig.4 8