For motors controlled

Similar documents
Common Bus and Line Regeneration

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Technical Explanation for Inverters

Drive Fundamentals. Motor Control Bootcamp May 15-18, Copyright 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC CO900H

Variable Speed Drives in Electrical Energy Management. Course Content

V1000, A1000, E7, F7, G7,

MX1S Matrix Converter

SDC,Inc. SCR-Regenerative Ac Drive

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

VFD E Series. Features

EE6351 ELECTRIC DRIVES AND CONTROL UNIT-1 INTRODUTION

U1000 INDUSTRIAL MATRIX DRIVE

Application Note CTAN #127

AC DRIVES. AC Drives. The word "drive" is used loosely in the industry. It seems that people involved

Product Application. Application: Delta C2000 Series AC Motor Drive and AFE2000 Active Front-End Unit for Bridge Crane (Overhead Travelling Crane)

STEP Motor Control Centers

The MICROMASTER has four modes of operation:

ASHRAE - Variable Speed Drives. By Dan Watkins, LEED BD+C Bornquist, Inc.

by William Gilbert, Industry Business Development Manager, Converting and Cranes, Motion Control Solutions

Fundamentals of Motors

Application Note: SyMAX Permanent Magnet Motor Simple Startup Procedure

ADJUSTABLE FREQUENCY CRANE CONTROLS

SHENZHEN KEWO ELECTRIC TECHNOLOGY CO., LTD

Modern Motor Control Applications and Trends Tomas Krecek, Ondrej Picha, Steffen Moehrer. Public Information

General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor

Industrial Motors. But first..servos!

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

1.1 Block Diagram of Drive Components of Electric Drive & their functions. Power Processor / Modulator. Control. Unit

VFD Best Practices: Getting the Most from Your VFD Investment

Expanding Application of FRENIC-Lift Series for Elevators

Open Drive Excellence in the control

Standard VVMC-1000 or VFMC-1000 controls, dispatched by an M3 Group System, allow group configurations with 64 landings and as many as 12 cars.

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

QUESTION BANK SPECIAL ELECTRICAL MACHINES

Neuro-Fuzzy Controller of a Sensorless PM Motor Drive for Washing Machines

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

Pump ED 101. Variable, Fixed Speed Control - - Float Switch Activation. Introduction

Inverter control of low speed Linear Induction Motors

Note 8. Electric Actuators

Up gradation of Overhead Crane using VFD

Whitepaper Dunkermotoren GmbH

10. Starting Method for Induction Motors

ALTERNATING CURRENT - PART 1

AC Motors vs DC Motors. DC Motors. DC Motor Classification ... Prof. Dr. M. Zahurul Haq

High starting performance synchronous motor

CT430 - Soft Starters on Motor Applications

5 amp 48 volt sensorless motor drivers

Fincor Series 2230 MKII/2240

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

When to use a Soft Starter or an AC Variable Frequency Drive

Step Motor. Mechatronics Device Report Yisheng Zhang 04/02/03. What Is A Step Motor?

Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please

INTRODUCTION. I.1 - Historical review.

YASKAWA AC Drive High Performance Vector Control A1000

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

YASKAWA AC Drive High Performance Vector Control A1000

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc.

Shaft Grounding Rings. Protecting VFD Driven Motors from Bearing Currents

Product Manual. 42BYGH40(M)-160-4A NEMA 17 Bipolar 5.18:1. Planetary Gearbox Stepper

International Journal of Advance Research in Engineering, Science & Technology

Introduction. Upon completion of Basics of AC Drives you should be able to: Explain the concept of force, inertia, speed, and torque

UPS Ratings-Not so Apparent

ECE1750, Spring Motor Drives and Other

Welcome to the Applications training module for the ACS800 Single drives. If you need help navigating this module, please click the Help button in

Synchronous Motor Drives

FRENIC-Mega Series of High-performance Multi-function Inverters

CHAPTER 2 MODELLING OF SWITCHED RELUCTANCE MOTORS

2. Draw the speed-torque characteristics of dc shunt motor and series motor. (May2013) (May 2014)

Standard Drives A & D SD Application Note

Medium voltage drive for single or multimotor applications, 3 27 MW

The seal of the century web tension control

Is Your Factory Power Source Corrupting Your Product Testing? September 2015 Author: Steve Boegle Engineering Group Leader, Behlman Electronics

YASKAWA AC Drive High Performance Vector Control A1000

Welcome to the SEI presentation on the basics of electricity

YASKAWA AC Drive High Performance Vector Control A1000

Primer. Stepper Motors

Five Reasons for VFDs in HVAC Applications

Battery powered ignition

YASKAWA AC DRIVES. Yaskawa AC Drives The Global Leader in Quality and Reliability. Certified for ISO9001 and ISO14001

VARIABLE FREQUENCY DRIVE AND ITS INDUSTRIAL APPLICATIONS

SHENZHEN KEWO ELECTRIC TECHNOLOGY CO., LTD

NEW! Complete IMPULSE Control Panels Available

HIGH PERFORMANCE VECTOR CONTROL DRIVE

Inverter Speed Ratio Information

Baldor Motor Basics Part 11

Power Factor Correction

Center Winder Specification

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Variable Speed Pumping

Special-Purpose Electric Machines

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

DC-DC CONVERTER. 5.1 Advantages & Disadvantages of DC-DC Converters

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

Introduction: Electromagnetism:

Electromotive Systems IMPULSE G+ Mini Adjustable Frequency Crane Controls

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Transmission & Distribution Glossary of Electrical Terms

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES

Design, Engineering, and Manufacturing of Motors for Electric Vehicle Applications

Transcription:

STEVE PETERSON Technical Training Engineer Yaskawa America Inc., Waukegan, IL Electronically reprinted from November 20, 2014 Choosing the right CONTROL METHOD for VFDs For motors controlled by a variable frequency drive (VFD), the control method used in large part determines a motor s efficiency and performance in an application. Once engineers and designers understand the advantages, disadvantages, and particular specifications for each control method, choosing the right one for any application becomes simple. CONTROL METHODS Many people in the industry think control methods are the sequencing methods that control VFDs, as in 2- and 3-wire setups. Such 2- and 3-wire setups determine whether a VFD s input-control terminals interface with maintained contacts or momentary push but- Motors account for at least half of the energy consumed in the U.S. Selecting the right control method for an application lets the motor run most efficiently while maximizing torque and overall performance. Efficiently run motors also use less energy and have less downtime for greater overall savings. Variable frequency drives come in all sizes, as demonstrated by these two VFDs from Yaskawa America Inc. Both are in the company s A1000 Series of drives and are powered by three-phase 380 to 480 V. The 0004FAA (above right) model s normal duty current load is 4.1 A, it handles up to 2 hp motors, and weighs 9 lb. The 0208AAA model, on the other hand, uses up to 208 A during normal duty cycles, handles 150 hp, and weighs 218 lb.

Voltage Carrier frequency Time AC motors are commonly controlled using pulse-width modulation. In that process, the carrier frequency (shown in red) is the rate at which the VFD s output transistors are gated or tuned on. The carrier frequency can usually be from 2 to 15 khz. The frequency reference (in blue) is the speed signal being sent to the motor, usually from 0 to 60 Hz. When overlaying the two waveforms, engineers can use the intersection points between Frequency reference these two curves to modulate the output DC pulses (in black) DC bus output to provide the desired speed control. V/F CONTROL Volts-per-hertz, commonly called V/f, is the simplest motor control method. It is often used due to its plug-and-play simplicity and how little motor data the drive needs. It does not require an encoder and tuning the VFD to the motor is not required (but recommended). This means lower costs and less wiring. V/f control is often used when there is a demand for operations which could exceed 1000 Hz, so it is often employed in machine tool and spindle applications. V/f is the only control method that lets several motors run from a single VFD. In such cases, all motors start and stop at the same time, and follow the same speed reference. V/f has some limitations. For example, with V/f, there is no guarantee the motor-shaft is rotating. Additionally, the motor s starting torque is limited to 150% of its output at 3 Hz. The limited starting torque is more than enough for most variable torque applications. In fact, just about every variable torque fan and pump app in the field uses V/f control. The V/f method s relative simplicity is partly due to its looser specifications. Speed regutons to start and stop the drive. The control methods focused on in this article are perhaps more accurately called motor-control methods. They determine how VFDs control motors. There are four primary types of motor control methods for induction motors connected to VFDs: volts-per-hertz (V/f), V/f with encoder, open-loop vector, and closed-loop vector. These methods all use pulse-width modulation (PWM), a technique that varies the width of a fixed signal by modulating pulse durations to create a variable analog signal. PWM is applied to VFDs by using the fixed DC voltage from the VFD s DC bus capacitors. A set of insulated gate bipolar transistors (IGBTs) on the output side rapidly open and close to generate pulses. Varying the output pulses width in the output-voltage waveform can build a simulated AC sine wave. Even though the drive s output-voltage waveform consists of square waves due to DC pulsing, the current waveform will be sinusoidal because the motor is inductive. All motor-control methods rely on a PWM voltage waveform to control the motor. The difference between control methods lies in how they calculate the motor s voltage needs at any given moment.

V/F WITH ENCODER If an application needs more precise speed regulation, along with the ability to run at a higher reference frequency, an encoder can be added to V/f control. The encoder feedback tightens speed regulation down to 0.03% of the maximum frequency. Output voltage is still determined by the selected V/f patlation is typically 2% to 3 % of maximum frequency. Speed response is rated at 3 Hz. Speed response is defined as how well the VFD responds to a change in reference frequency. An increase in speed response results in quicker motor responses when the reference frequency changes. Voltage (V) V/f patterns Constant-torque V/f pattern 230 230 17.3 10.4 0 1.5 30 50 60 Frequency (Hz) Control methods also have speed-control ranges (expressed as ratios). V/f s speed control range is 1:40. Multiplying this ratio by the maximum frequency determines the VFD s minimum running speed at which it can control the motor. For example, with a 60-Hz maximum frequency and 1:40 speed control range, a drive using V/f control can control a motor down to 1.5 Hz. A V/f pattern defines a ratio of voltage-tofrequency for the motor to follow, and a VFD can have only one V/f pattern programmed at a time. The V/f pattern, or curve, will ultimately determine what voltage is output to the motor based on a given speed reference (frequency). Operators or technicians can select preset V/f patterns in the VFD s programming with a single parameter. Preset patterns are optimized for specific applications. Users can go one step further, programming a custom V/f pattern or profile to tune the VFD to a specific application and motor being used. Applications such as fans and pumps are variable torque loads. A variable-torque V/f pattern prevents faults and increases perfor- Voltage (V) 40.3 9.2 0 Variable-torque V/f pattern 1.5 30 60 Frequency (Hz) Different V/f patterns let VFDs control several different applications while maintaining optimal performance for each. The constant torque pattern is a straight line, which results in a constant V/f ratio that provides constant motor torque throughout the speed range. The variable-torque pattern has lower voltages at lower speeds to prevent motor saturation. mance and efficiency. It reduces the magnetized current at low frequencies by lowering the motor voltage at lower frequencies. Similarly, constant-torque applications, such as conveyors, should use constant-torque V/f patterns. These apps need full magnetizing current at all speeds. So a straight slope is constructed and followed throughout the entire speed range. In general, the VFD will output a voltage based on whatever speed the motor is set to while referencing the V/f pattern.

tern programmed into the VFD by a technician. This allows for high-speed control without high dynamic responses because voltage and frequency are predetermined. This control method is not common because it entails the costs of an encoder and feedback card, and its advantages over standard V/f control Motor rotation Torque Reverse motor rotation are minimal. Starting torque, speed response, and speed control range are all identical to the V/f control. In addition, higher operating frequencies are limited by how many pulseper-revolutions are generated by the encoder. OPEN-LOOP VECTOR CONTROL Open-loop vector (OLV) control is used for greater and more dynamic motor control. It independently controls motor speed and torque, much like the way DC motors are controlled. When running OLV, motors can produce 200% of their rated torque at 0.3 Hz. The higher starting torque at lower speeds opens the door for a variety of applications. This control method also allows for four-quadrant torque limits. Torque limits primarily restrict motor torque to prevent damage to equipment, machinery, or products. They are broken into four different quadrants, depending on motor direction (forward or reverse), and whether the motor is motoring or regenerating. The limits can be set independently for each quadrant, or users can program an overall torque limit into the VFD. A motoring condition is when the motor s Four quadrants of torque limits 2 3 Positive torque 1 4 Negative torque Forward motor rotation Torque limits are broken down into four quadrants depending on motor direction (forward or reverse) and whether the motor is motoring or regenerating. For example, a bottle capper would require torque limits set up for 1. Alternatively, an unwinding application would need forward motor rotation to feed the line, but a negative torque limit due to regeneration caused by the line being pulled to create tension. So the torque limit would be set in 4. speed and torque are both in the same direction. For example, forward speed and forward torque would motor a conveyor in the forward direction. Regeneration is when the motor is being overhauled by the load. On an AC motor, when the rotor rotates faster than the magnetic field in the stator, it acts as a generator. This causes regenerated energy to flow back into the VFD. For example, a bottle capper could use a torque limit in 1 (forward rotation and positive torque) to prevent over-torquing the bottle caps. It moves forward and uses positive torque to put the cap on the bottles. An application involving an elevator with a counterweight heavier than the empty car would have limits in 2 (reverse motor rotation and positive torque). If an empty car is called to a higher floor, the torque opposes the direction of the speed to maintain control over the counterweight and the elevator s speed and position as it moves against gravity. A machine drill backing a screw out of a block of wood (reverse motor direction and negative torque) could use limits in 3. And an unwinding application could

use 4 limits (forward motor rotation and negative torque). The motor would spin forward to feed the line, but would also need a negative torque limit due to regeneration caused by pulling the line, creating tension. The current feedback loop in these VFDs lets users set torque limits and run in all four quadrants. As motor current increases, so does motor torque. Output voltage going to the motor can be increased if the application needs more torque or decreased when reaching a torque limit. This makes open-loop control dynamic, unlike V/f control. In addition to torque limits, open-loop control has a quicker speed response of 10 Hz, letting it handle more dynamic responses to impact loads. For example, a rock crusher s load constantly changes, depending on the size and quantity of rock being processed. Instead of a fixed V/f pattern, OLV control uses a vector algorithm to find the best output voltage to run the motor. Vector control accomplishes this by using current feedback from the motor. Current feedback is measured via current transformers inside of the VFD. Constant current readings and rapid calculations performed in the VFD V/F CONTROL CHECKLIST Auto tuning not required (but recommended) High Frequency Reference possible (>400 Hz) Several motors controlled from one VFD Simple closed-loop performance possible No encoder required Good for motors with unknown data No guarantee motor shaft is responding due to lack of feedback Starting torque is 150% at 3Hz Speed regulation: ± 2 to 3% of max. frequency Speed response: 3 Hz Speed control range: 1:40 Output voltage determined by: V/f pattern V/F WITH ENCODER CONTROL CHECKLIST Auto tuning not required (but recommended) High Frequency Reference possible (>400 Hz) but limited by encoder PPR Better speed control than V/f control Encoder and feedback card required Starting torque is 150% at 3Hz Speed regulation: ± 0.03% of max. frequency Speed response: 3 Hz Speed control range: 1:40 Output voltage determined by: V/f pattern determine present torque demand and flux. Basic vector math breaks down the motor s magnetizing current and torque-producing current into vectors. OLV control depends heavily on the motor dynamics, so some type of motor auto-tuning must be performed to ensure the VFD has as much motor data as possible. With the help of reliable motor data/parameters, the VFD can calculate the magnetizing current (I d ) and the torque-producing current (I q ) as vectors. For maximum efficiency and torque, the VFD must keep these two vectors separated by 90. That 90 is particularly significant because sin (90) = 1, and the value 1 represents maximum motor torque. Overall OLV control results in tighter control. Speed regulation is ±0.2% of maximum frequency, and the speedcontrol range jumps to 1:200, allowing for low-speed operation without sacrificing torque. CLOSED-LOOP VECTOR CONTROL Closed-loop vector control uses a vector algorithm to

determine output voltage, much like the open-loop control. The key difference is that closed-loop vector uses an encoder. Encoder feedback, paired Iq with the vector control, means 200% of the motor s rated torque is available at 0 rpm. This is a selling point for Θ apps required to hold a load without moving, such as elevators, cranes, and hoists. Encoder feedback allows for speed responses over 50 Hz and speed control ranges of 1:1500, the highest of all the control methods. Closed-loop control is also able to run a motor in torque-control mode. Torque control enables the VFD to control motor Vector control I d I 1 Vector control maximizes torque-per-amp by keeping torque-producing current (I q ) and magnetizing current (I d ) at 90. I 1 represents total motor current (I q + I d ). If Ө > 90, then sin Ө > 1; if Ө < 90, then sin Ө > 1; but if Ө = 90, then sin Ө = 1 and torque is at its maximum. VFDs try to keep Ө at 90 to mimic a DC motor. In a DC motor, the brushes are mechanically positioned 90 from the commutator to constantly produce maximum torque. torque rather than motor speed. This functionality is required in any application where torque is a more important factor than speed. Winders, rewinders, capping, and web applications are several good examples of where torque control is employed. OPEN-LOOP VECTOR CONTROL CHECKLIST No encoder required Good starting torque: 200% of rated toque at 0.3 Hz Four-quadrant torque limits possible Good for impact loads Speed regulation: ± 0.2% of max. frequency Speed response: 10 Hz Speed control range: 1:200 Output voltage determined by: vector algorithm Auto-tuning required for best performance No guarantee motor shaft is responding due to lack of feedback CLOSED-LOOP VECTOR CONTROL CHECKLIST Can operate in torque-control mode Excellent starting torque: 200% of rated torque at 0 rpm For-quadrant torque limits possible Best for impact loads Zero-speed operation possible Speed regulation: ± 0.02% of max. frequency Speed response: >50 Hz Speed control range: 1:1,500 Output voltage determined by: vector algorithm Auto-tuning required for best performance Encoder and feedback card required Posted with permission from November 20, 2014. Machine Design, Penton Media, Inc. Copyright 2015. All rights reserved. For more information on the use of this content, contact Wright s Media at 877-652-5295 PR.MachineDesign.02 114935