HS1E Interlock Swithes with Solenoid

Similar documents
HS1E-K Interlock Switches with Solenoid (3-circuit)

HS1L Interlock Switches with Solenoid

HS1C Interlock Switches with Solenoid

HS5E Miniature Interlock Switches with Solenoid

Door Interlock Switches

HS5D Miniature Interlock Switches

HS1E Series Full Size Solenoid Locking Switches

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

Door Interlock Switches

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1C-P Interlock Plug Unit with Door Lock

HS5E Series Miniature Solenoid Locking Switches

HS6B Series Subminiature Interlock Switch

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

HS5D Miniature Interlock Switches

Door Interlock Switches

HS6E - L 4 4 B 01 - G

HS5E Miniature Interlock Switches with Solenoid

HS6E Subminiture Interlock Switches with Solenoid

Door Interlock Switches

HS6E Subminiature Interlock Switches with Solenoid. Double Installation. Part Number. Cable Length (+) ( ) A2 A1

HS5E Miniature Interlock Switches with Solenoid

Solenoid Locking Safety Switches

HS6B HS6E. Angled connection. cable. Compact with three poles of contacts. (HS6B) Small interlock switch with five poles and solenoid.

SG-B1 SERIES / SG-A1 SERIES

Head Removal Detection Function for Safer Performance

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

Interlock Switches. Safety. Selection Guide HS6B Subminiature HS5D Miniature HS2B Full Size...

Solenoid Locking Safety Switches

Door Interlock Switches

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Section. Safety Products Selection Guide...B-2

Standard Interlock Safety Switches

Interlock Switches Interlock Plugs

Standard Interlock Safety Switches

ct O en n Tr ve Solenoid Indicator (1) TÜV rating AC V, 3A 3 Mounting Examples

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

Safety device new products line up. Introducing a safety door switch with solenoid interlock that is among the world s thinnest*

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

HS6B Subminiature Interlock Switches

ø8 A8 Series Miniature Control Units

ø10 A1 Series Miniature Control Units

2 Specifications and Ratings. Applicable Standards. Operating Condition. Thermal Current Ith 10A Contact Ratings. Operating Speed

ø12 A2 Series Miniature Control Units

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

RU Series Universal Relays

Safety Control HR1S-AC. Safety Relay HR1S-AC

HS7A-DMC Non-contact Interlock Switches

Hinged Safety Door Switch

UP Series Miniature Pilot Lights

XW Series Emergency Stop Switches

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Safety switches with separate actuator

Enabling Switches Grip Style Enabling Switches

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

XA Series Emergency Stop Switches (w/removable Contact Block)

Manual Reset Limit Switch

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

LK Position Switches TECHNICAL DATASHEET.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Safety Limit Switch

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

Oiltight Switches & Pilot Devices

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

22mm XW E-Stops. UL File #E68961 CCC No Specifications

D4BL. Guard Lock Safety-door Switch

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Limit Switches with Positive Opening Mechanism

XW Series E-Stops. Safety. Selection Guide ø22mm XW E-Stops

Safety switches with separate actuator

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility

Safety switches with solenoid and separate actuator

XW Series E-Stops. Safety. ø22mm XW E-Stops Phone: Fax: Web: -

Safety-door Switch. Ordering Information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

LR-LX-LK-LW Safety Switches with separate actuator

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Safety rope switches with reset for emergency stop

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

F3S-TGR-KHL1/-KHL3/-KHL3R

22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4BS CSM_D4BS_DS_E_8_4

Enabling Switches. Safety. Selection Guide

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

Bright illumination face and snap-action switching.

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D4GS-N CSM_D4GS-N_DS_E_7_2

Transcription:

HSE Interlock Swithes with Solenoid Lightweight interlock switch in plastic housing, providing high locking strength Basic unit and solenoid unit in one housing Lightweight plastic housing All terminal screws are M., allowing easy wiring. Spring lock and solenoid lock are available. Equipped with two actuator entry slots. Double insulation structure Retention Force 000N Ideal locking mechanism and robust actuators for large doors. Accommodation of actuator entry slots to rattling doors is enhanced. Spring Lock Automatically locks the actuator without power applied to the solenoid. After the machine stops, unlocking is completed by the solenoid, providing high safety features. Manual unlocking is possible in the event of power failure or maintenance. Solenoid Lock The actuator is locked when. The actuator is unlocked when de-. Retention force for horizontal direction (parallel to the mounting panel) Straight Angle Adjustable Right-angle BG Standard in Germany Direct Opening Action Double Insulation Parts and Functions Conduit Port Use IP conduit or gland. Contact Mechanism Locking Ring Indicator (green or red) Terminal Block (M.) Straight (SUS0) (green or red) (Zinc Diecast) Angle Adjustable (SUS0) (for hinged doors) Right-angle (SUS0) Terminal Block for Pilot Light (M.) Two Entry Slots

HSE HSE Interlock Swithes with Solenoid Ratings Contact Ratings Rated Insulation Voltage (Ui) 00V (between or solenoid and ground: 0V) Rated Thermal Current (Ith) Main circuit: 0A Auxiliary circuit: A Rated Voltage (Ue) 0V V 0V Rated Current (Ie) (Note) Main Monitor AC DC AC DC Resistive load (AC-) 0A 0A A Inductive Load (AC-) 0A A A Resistive load (DC-) A Inductive Load (DC-) A 0.9A Resistive load (AC-) A A Inductive Load (AC-) A Resistive load (DC-) A Inductive Load (DC-) 0.9A Minimum applicable load (reference value): V AC/DC, ma (Applicable range is subject to operating conditions and load) Note: Ratings approved by safety agencies: A00: AC- A/0V Solenoid Locking Mechanism Spring Lock Solenoid Lock Rated Voltage V DC (00% duty cycle) Rated Current 9 ma Coil Resistance Ω (at 0 C) Pickup Voltage Rated voltage % maximum (at 0 C) Dropout Voltage Rated voltage 0% minimum (at 0 C) Maximum Continuous Applicable Voltage Rated voltage 0% Maximum Continuous Applicable Duration Continuous Insulation Class Class F Indicator Rated Voltage Rated Current Light Source Light Color The lens cannot be replaced. V DC 0 ma G (green), R (red) Specifications UL0 (UL listed) CSA C., No. (c-ul listed) ISO 9 EN 0 (TÜV approval) Applicable Standards IEC 09-- EN 09-- (TÜV approval) GS-ET-9 (BG approval) GB0. (CCC approval) IEC 00-/EN 00- (applicable standards for use) Operating Temperature 0 to 0 C (no freezing) Relative Humidity to % (no condensation) Storage Temperature 0 to +0 C (no freezing) Pollution Degree Impulse Withstand Voltage kv (between, solenoid and grounding:. kv) Insulation Resistance (00V DC megger) Between live and dead metal parts: 00 MΩ minimum Between live metal part and ground: 00 MΩ minimum Between live metal parts: 00 MΩ minimum Between terminals of the same pole: 00 MΩ minimum Electric Shock Class II (IEC 0) Degree of IP (IEC 09) Shock Resistance Damage limits: 000 m/s Vibration Resistance Operating Speed Direct Opening Travel Direct Opening Force Retention Force Operating Frequency Mechanical Life Electrical Life Conditional Short-circuit Current Weight (approx.) Operating extremes: 0 to Hz, amplitude 0. mm Damage limits: 0 Hz, amplitude. mm 0.0 to.0 m/s mm minimum 0N minimum 000N minimum (HSE- MS: GS-ET-9) (00N for vertical direction to the mounting panel) 900 operations per hour,000,000 operations minimum (GS-ET-9) 00,000 operations minimum (AC-, 0V, A),000,000 operations minimum (V AC/DC, 00mA) (operating frequency 900 operations per hour) 00A (0V) (Use 0V/0A fast-blow fuse for short-circuit protection.) 00g Flush Silhouette Switches & Pilot Lights Lights Illumination Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Protectors Power Supplies PLCs & SmartRelay Part No. Development Contact Confi guration Main Monitor Blank: NC+NC NO/NO : NC+NC NO : NC+NC NC/NC : NC+NC NC Solenoid Voltage/Lock Mechanism : V DC/Spring Lock Y: V DC/Solenoid Lock H S E - K MS R P - R Indicator Color G: green R: red Conduit Port Blank: G/ P: PG. Housing Color R: red/black Retention Force MS: 000N Manual Unlock Key Blank: Without key K: With key Indicator Rated Voltage : V DC 0: Without indicator Retention force for horizontal direction (parallel to the mounting panel) Operator Interfaces Sensors Control Stations Explosion References / Key Wrench for TORX Screws Name Specifi cation Part No. Ordering No. Package Quantity Straight HS9Z-A HS9Z-A Right-angle HS9Z-A HS9Z-A Angle Adjustable (for hinged door) HS9Z-A HS9Z-A Straight HS9Z-AS HS9Z-AS Right-angle actuator HS9Z-AS HS9Z-AS Angle Adjustable (for hinged door) HS9Z-AS HS9Z-AS Key Wrench for TORX Screws HS9Z-T HS9Z-T Conduit Port Plug HS9Z-P HS9Z-P Locking Ring for Gland M0 thread HW9Z-NM0 HW9Z-NM0PN0

HSE Interlock Swithes with Solenoid Interlock Switch Lock Mechanism Contact Confi guration Conduit Port Size Indicator Style Manual Unlock Key Part No. Pilot Light Monitor Lock Monitor ( inserted) (Solenoid OFF) ( ) ( ) G/ HSE-0MSR With HSE-MSR-➁ With HSE-0KMSR Main : NC+NC, Monitor : NO Main : Monitor : PG. With With HSE-KMSR-➁ HSE-0MSRP With HSE-MSRP-➁ With HSE-0KMSRP Spring Lock Main : NC+NC, Monitor : NC With With HSE-KMSRP-➁ HSE-0MSR Main : Monitor : G/ With HSE-MSR-➁ With HSE-0KMSR With With HSE-KMSR-➁ HSE-0MSRP PG. With HSE-MSRP-➁ With HSE-0KMSRP With With HSE-KMSRP-➁ Pilot Light Monitor Lock Monitor ( Inserted) (Solenoid ON) G/ HSE-Y0MSR With HSE-YMSR-➁ With HSE-Y0KMSR Main : NC+NC, Monitor : NO Main : Monitor : PG. With With HSE-YKMSR-➁ HSE-Y0MSRP With HSE-YMSRP-➁ With HSE-Y0KMSRP Solenoid Lock Main : NC+NC, Monitor : NC With With HSE-YKMSRP-➁ HSE-Y0MSR Main : Monitor : G/ With HSE-YMSR-➁ With HSE-Y0KMSR With With HSE-YKMSR-➁ HSE-Y0MSRP PG. With HSE-YMSRP-➁ With HSE-Y0KMSRP With With HSE-YKMSRP-➁ Key wrench for TORX* screws (HS9Z-T) is supplied with the interlock switch. Specify an indicator color code in place of in the Part No. G: green, R: red is not supplied with the interlock switch, and must be ordered separately.

HSE HSE Interlock Swithes with Solenoid Dimensions HSE- MS Horizontal Mounting Straight HS9Z-AS 0 Vertical Mounting Right-angle HS9Z-AS Flush Silhouette Switches & Pilot Lights Lights 0 (.0).0 ±0.* 0. (RP) 9. (. ±0. *). (RP) -M Mounting Holes RP: Mounting Reference Position Slot Plug (supplied) (Note). 9. 0 0... 9. 9 Note: Plug the unused atuator entry slot using the slot plug supplied with the interlock switch. Use three mounting screws to mount the interlock switch according to the mounting hole layout. * center position Mounting Reference Position (RP) As shown in the figure below, the mounting reference position of the actuator when inserted in the interlock switch is: The actuator cover touches the interlock switch lightly. After mounting the actuator, remove the actuator cover from the actuator switch. Stop.. 9 Cover HS9Z-AS Cushion Sponge 9 -M Screw Mounting Hole Layout.. ±0. * ±0. *. (RP).. (RP) Cover HS9Z-AS Cushion Sponge Illumination Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Protectors Power Supplies Interlock Switch Interlock Switch PLCs & SmartRelay Cover Stop Cover Operator Interfaces Sensors Control Stations Explosion References

HSE Interlock Swithes with Solenoid Dimensions Straight (HS9Z-AS) -M Screws ø.0 9 9. 0. 9. 0. Mounting Holes When installed () ø. Cover (gray). Right-angle (HS9Z-AS) -M Screws ø (.) 0.... 0. When installed (). 0. Mounting Holes ø. Cover (gray) 90 Angle Adjustable (HS9Z-AS) (Note) Stop Film (attached). max. () 0 R. Angle Adjustment Screw (M hexagon socket head screw) 0 0 hinge -M Screws Mounting Holes Note: The actuator cover and actuator stop fi lms are supplied with the actuator and used when adjusting the actuator position. Remove the actuator cover and actuator stop fi lm after the actuator position is determined.

HSE HSE Interlock Swithes with Solenoid Diagrams and Operating Characteristics Flush Silhouette Spring Lock HSE- MSR- (Main : NC+NC, Monitor : NO) Status Status Machine ready to operate Solenoid de Interlock Switch Status Status Solenoid Status Solenoid Manual Unlock Solenoid de Solenoid de Switches & Pilot Lights Lights Illumination UNLOCK Safety Products Diagram Terminal Blocks Comm. Terminals Contact Configuration Monitor Lock Monitor ( inserted) (Solenoid OFF) Indicator Main : Monitor : Main -: Closed Monitor -: Open -: Open -: Closed -: Closed -: Open -: Power OFF -: Power ON -: Power ON -: Power OFF -: Power OFF Solenoid Power -: Open -: Open -: Open -: Open AS-Interface Relays & Timers Main circuit: Connected to the machine drive control circuit, sending interlock signals to the protective door. Monitor circuit: Sends ON/OFF signals of the main circuit and monitoring signals of open/closed status of the protective door. HSE- Sockets Protectors MSR- (Main : NC+NC, Monitor : NC) Status Status Machine ready to operate Solenoid de Interlock Switch Status Status Solenoid Status Solenoid Manual Unlock Solenoid de Solenoid de Power Supplies PLCs & SmartRelay Operator Interfaces UNLOCK Diagram Contact Configuration Monitor Lock Monitor ( inserted) (Solenoid OFF) Indicator Main : Monitor : Sensors Main -: Closed -: Open -: Open -: Open -: Open Monitor -: Closed -: Closed -: Open -: Open -: Closed -: Power OFF -: Power ON -: Power ON -: Power OFF -: Power OFF Solenoid Power Control Stations Explosion References Main circuit: Connected to the machine drive control circuit, sending interlock signals to the protective door. Monitor circuit: Sends ON/OFF signals of the main circuit and monitoring signals of open/closed status of the protective door. Operation Characteristics (reference) 0 ( insertion position). (Locked position) 0.0 (Approx. travel in mm).0 0.0 Main Monitor ( open, NO) Monitor ( closed,nc) Lock Monitor (Unlocked, NO) Lock Monitor (Locked, NC) Contacts ON (closed) The operation characteristics show the contact status when the actuator enters into the center of the entry slot. The circuit No. - and - are interconnected. Use circuits - and - for safety circuits. Contacts OFF (open)

HSE Interlock Swithes with Solenoid Solenoid Lock HSE-Y MSR- (Main : NC+NC, Monitor : NO) Status Status Status Status Manual Unlock be be Machine ready to be started started operate started Solenoid de Solenoid de Solenoid Solenoid Interlock Switch Status be started Solenoid de, then UNLOCK Contact Configuration Indicator Lock Monitor Monitor ( inserted) (Solenoid ON) Main : Monitor : Diagram Main -: Closed -: Open -: Open -: Open -: Open Monitor -: Open -: Open -: Closed -: Closed -: Open -: Power ON -: Power OFF -: Power OFF -: Power ON -: Power OFF ON Solenoid Power (Note ) (Note) (Note ) Main circuit: Connected to the machine drive control circuit, sending interlock signals to the protective door. Monitor circuit: Sends ON/OFF signals of the main circuit and monitoring signals of open/closed status of the protective door. Note : Do not attempt manual unlocking while the solenoid is. Note : Do not energize the solenoid for a long time while the door is open or while the door is unlocked manually. HSE-Y MSR- (Main : NC+NC, Monitor : NC) Status Status Status Manual Unlock Status be be Machine ready to be started started operate started Solenoid de Solenoid de Solenoid Solenoid Interlock Switch Status be started Solenoid de, then UNLOCK Diagram Contact Configuration Indicator Lock Monitor Monitor ( inserted) (Solenoid ON) Main : Monitor : Main -: Closed -: Open -: Open -: Open -: Open Monitor -: Closed -: Closed -: Open -: Open -: Closed -: Power ON -: Power OFF -: Power OFF Solenoid Power -: Power ON (Note ) -: Power OFF ON (Note) (Note ) Main circuit: Connected to the machine drive control circuit, sending interlock signals to the protective door. Monitor circuit: Sends ON/OFF signals of the main circuit and monitoring signals of open/closed status of the protective door. Note : Do not attempt manual unlocking while the solenoid is. Note : Do not energize the solenoid for a long time while the door is open or while the door is unlocked manually. Operation Characteristics (reference) 0 ( insertion position). (Locked position) 0.0 (Approx. travel in mm).0 0.0 Main Monitor ( open, NO) Monitor ( closed,nc) Lock Monitor (Unlocked, NO) Lock Monitor (Locked, NC) Contacts ON (closed) Contacts OFF (open) The operation characteristics show the contact status when the actuator enters into the center of the entry slot. The circuit No. - and - are interconnected. Use circuits - and - for safety circuits.

HSE HSE Interlock Swithes with Solenoid Safety Precautions In order to avoid electric shock or fi re, turn power off before installation, removal, wire connection, maintenance, or inspec tion of the interlock switch. If relays are used in the circuit between the interlock switch and the load, consider the danger and use safety relays, since welded or sticking contacts of standard relays may invalidate the functions of the interlock switch. Perform risk assessment and establish a safety circuit which satisfi es the requirement of the safety category. Do not place a PLC in the circuit between the interlock switch and the load. Safety security can be endangered in the event of a malfunction of the PLC. Instructions Regardless of door types, do not use the interlock switch as a door stop. Install a mechanical door stop at the end of the door to protect the interlock switch against excessive force. Do not apply excessive shock to the interlock switch when opening or closing the door. When wiring, unscrew the cover with part number label only. Unnecessary loosening of other screws may cause a malfunc tion of the interlock switch. A shock to the door exceeding,000 m/s (approx. 00G) may cause the contacts of the interlock switch to chatter, and a malfunction of the interlock switch may occur. Prevent foreign objects such as dust and liquids from entering the interlock switch while connecting a conduit or wiring. If the operating atmosphere is contaminated, use a protective cover to prevent the entry of foreign objects into the interlock switch through the actuator entry slots. Entry of a considerable amount of foreign objects into the interlock switch may affect the mechanism of the interlock switch and cause a malfunction. Plug the unused actuator entry slot using the slot plug supplied with the interlock switch. Do not store the interlock switch in a dusty, humid, or organicgas atmosphere. Use dedicated actuators only. When other actuators are used, the interlock switch may be damaged. Do not modify the actuator, otherwise it will damage the interlock switch. The cover uses special screws which cannot be removed or tightened by general screwdrivers. Use the special wrench supplied with the interlock switch. Regardless of door types, do not use the interlock switch as a door lock. Install a separate lock using a latch or other measures. While the solenoid is, the interlock switch temperature rises to approximately 00 C. Do not touch to prevent burns. If cables come into contact with the interlock switch, use heat-resistant cables. The solenoid has polarity. Make sure of the correct polarity when wiring. Do not apply overvoltage, otherwise the solenoid will be burnt. retention force is 000N (static load). When larger force is expected, add a system using interlock switch without lock (ex. HSD) and sensor in order to detect door opening and to stop the machine. Do not disassemble or modify the interlock switch, otherwise a malfunction or an accident may occur. Do not install the actuator in the location where the human body may come into contact. Otherwise injury may occur. Solenoid lock is locked when, and unlocked when de-. When energization is interrupted due to wire disconnection or other failures, the interlock switch may be unlocked, causing possible danger to the operators. Sole noid lock must not be used in applications where locking is strictly required for safety. Perform risk assessment and determine whether solenoid lock is appropriate. Minimum Radius of Hinged When using the interlock switch for a hinged door, refer to the minimum radius of doors shown below. For the doors with small minimum radius, use angle adjustable actuators (HS9Z- AS). Note: Because deviation or dislocation of hinged door may occur in actual applications, make sure of the correct operation before installation. HS9Z-AS When the door hinge is on the extension line of the interlock switch surface: 0 mm Hinge 0 mm Hinge When the door hinge is on the extension line of the actuator mounting surface: 0 mm Hinge 0 mm HS9Z-AS Hinge Flush Silhouette Switches & Pilot Lights Lights Illumination Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion References 9

HSE Interlock Swithes with Solenoid Instructions When using the HS9Z-AS Angle Adjustable (vertical) When the door hinge is on the extension line of the interlock switch surface: 0 mm When the door hinge is on the extension line of the actuator mounting surface: HS9Z-A/AS 0 mm Angle Adjustment Using the angle adjustment screw, the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: 0 to 0 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the interlock switch. Recommended tightening torque for angle adjustment: 0. N m After adjusting the actuator angle, apply Loctite to the adjustment screw so that the screw will not move. Mounting Examples Mount the interlock switch on a fi xed machine or guard, and mount the actuator on the hinged door. Do not mount both interlock switch and actuator on the hinged doors, otherwise malfunction will occur. Application on Sliding s HSE Interlock Switch HS9Z-AS Latch Stop Application on Hinged s Latch For Manual Unlocking Spring lock The HSE allows manual unlocking of the actuator to pre-check proper door operation before wiring or turning power on, as well as for emergency use such as a power failure. Solenoid lock The interlock switch can be unlocked manually in emergency, such as when the interlock switch cannot be unlocked after deenergizing the solenoid. With Manual Unlock Key When unlocking the interlock switch manually, turn the key fully using the special manual unlock key supplied with the interlock switch. Using the interlock switch with the key not fully turned (less than 90 ) may cause damage to the interlock switch or operation failures (when manually unlocked, the interlock switch will keep the main circuit disconnected and the door unlocked). Do not apply excessive force to the manual unlock part, other wise the manual unlock part will become damaged. Do not leave the manual unlock key attached to the interlock switch during operation. This is dangerous because the inter lock switch can always be unlocked while the machine is in operation. Without Manual Unlocking Key Remove the screw located on the side of the interlock switch using the propri etary wrench supplied with the interlock switch. Insert a small screwdriver into the interlock switch to push the lever inside of the interlock switch toward the indicator until the actuator is unlocked (see the fi gure on the right). Common Unlocking Operation Insert a small screwdriver into the oblong hole on the back of the interlock switch, then push the lever inside the interlock switch toward the indicator until the actuator is unlocked (see below). 9 Caution. Unlock M Normal Position Unlock Manual Unlocking Position Screwdriver Note: This unlocking method is intended for an escape from a machine when a person is locked in. For access to the unlocking entry, an access hole should be opened on the control panel. When opening the hole, apply proper protection against water or other foreign objects. For solenoid lock, do not attempt manual unlocking while the solenoid is. Also, make sure that the machine has come to a complete stop before unlocking the interlock switch manually. Manual unlocking during machine operation loses the function of solenoid lock interlock switch. HS9Z-AS HSE Interlock Switch HS9Z-AS 0

HSE HSE Interlock Swithes with Solenoid Instructions Applicable Crimping Terminal. min. ø. min..9 max.. max. Use an insulation tube on the crimping terminal. When using stranded wires, make sure that loose wires do not cause short circuit. Also, do not solder the terminal to prevent loose wires. Applicable Wire Size 0. to. mm Applicable Cable Glands Use IP cable gland. When using M0-size cable gland, use locking ring HW9Z-NM0. 9 mm max. Wire When Using Flexible Conduits (Example) Flexible conduit example: VF-0 Conduit Port Size Plastic Cable Gland Metal Cable Gland G/ PG. M0 (Note ) Approx. Insulation Tube G/, PG., M0 0 mm max. Applicable Crimping Terminal RLC-0 RBC-0PG. RLC-0EC0 Recommended Tightening Torque of Mounting Screws Interlock switch:. to. N m (three M screws) Lid mounting screw: 0.9 to. N m (M screw) Terminal screw: 0.9 to. N m (M. screw) Connector:. to. N m s HS9Z-A/A/A/AS:. to. N m (two M screws) HS9Z-AS/AS:. to. N m (two M screws) Mounting bolts must be provided by users. The above recommended tightening torques of the mounting screws are the values confi rmed with hex socket head bolts. When other screws are used and tightened to a smaller torque, make sure that the screws do not come loose after mounting. Mounting bolts must be provided by the users. To avoid unauthorized or unintended removal of the interlock switch and the actuator, it is recommended that the interlock switch and the actuator be installed in an unremovable manner, for example using special screws or welding the screws. Conduit Port Opening Make an opening for wire connection by breaking one of the conduit-port knockouts on the interlock switch housing using a screwdriver. When breaking the conduit port, take care not to damage the contact block or other parts inside the interlock switch. Cracks or burrs on the conduit entry may deteriorate the housing protection against water. When changing to another conduit port, close the unused opening with an optional plug (Part No.: HS9Z-P). Plug Part No. HS9Z-P Flush Silhouette Switches & Pilot Lights Lights Illumination Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Protectors Power Supplies PLCs & SmartRelay Operator Interfaces When Using Multi-core Cables (Example) Conduit Port Size Plastic Cable Gland Metal Cable Gland G/ PG. M0 (Note ) SCS-0 (Seiwa Electric) ST. (K-MECS) ST-M0X. (K-MECS) (Note ) ALS- ABS- PG. ALS- EC0 Different cable glands are used depending on the cable sheath outside diameter. When purchasing a cable gland, confi rm that the cable gland is applicable to the cable sheath outside diameter. Note : When using M0 cable gland, order HW9Z-NM0 locking ring and replace with the locking ring installed in the HSE interlock switch. Note : When using ST-M0X. cable gland, use together with a gasket (Part No.: GPM0, K-MECS). Sensors Control Stations Explosion References

HSE Interlock Switches with Solenoid (-circuit) Dual main circuit + lock monitor circuit provide more safety to your system Basic unit and solenoid unit in one housing Lightweight plastic housing All terminal screws are M., allowing easy wiring. Two main circuits NC+NC and a monitor circuit NC realizes duplicated main circuit and lock monitor. Hostage control can be achieved using the hostage key. Guard door can be locked automatically by installing the actuator on the guard and interlock switch on the machine. Spring lock and solenoid lock are available. Equipped with two actuator entry slots. Double insulation structure 0 different numbers are available for key, so that neighboring switches cannot be operated by the same key. Retention Force 000N Ideal locking mechanism and robust actuators for large doors. Accommodation of actuator entry slots to rattling doors is enhanced. Spring Lock Automatically locks the actuator without power applied to the solenoid. After the machine stops, unlocking is completed by the solenoid, providing high safety features. Manual unlocking is possible in the event of power failure or maintenance. Solenoid Lock The actuator is locked when. The actuator is unlocked when de-. * Retention force for horizontal direction (parallel to the mounting panel) Manual Unlock Key BG Standard in Germany Hostage Key s for 000N* Retention Force Direct Opening Action Double Insulation Parts and Functions Conduit Port Use IP conduit or gland. Contact Mechanism Locking Ring Terminal Block (M.) Indicator (green or red) Straight Acuator (SUS0) Locking Ring (PA) Two Entry Slots Right-angle (SUS0) Terminal Block for Indicator (M.) (Diecast Zinc) Angle Adjustable (SUS0) for Hinged s

HSE HSE Interlock Switches with Solenoid (-circuit) Interlock Switch Lock Mechanism Spring Lock Contact Confi guration Main circuit ➀: Main circuit ➁: Monitor circuit: Monitor Lock Monitor ( inserted) (Solenoid OFF) Main circuit ➀: NC+NC, Lock monitor circuit: NC Main circuit ➁: NC+NC Main circuit ➀: Main circuit ➁: Monitor circuit: Conduit Port Size G/ PG. Main circuit ➀: NC+NC, Lock monitor circuit: NC Main circuit ➁: NC+NC G/ PG. Indicator Style Manual Unlock Key Hostage Key Part No. HSE-0MSR With HSE-MSR-➁ With HSE-0KMSR With With HSE-KMSR-➁ HSE-0MSRP With HSE-MSRP-➁ With HSE-0KMSRP With With HSE-KMSRP-➁ With HSE-K0MSR- With With HSE-KMSR-➁- With HSE-K0MSRP- With With HSE-KMSRP-➁- Flush Silhouette Switches & Pilot Lights Lights Illumination Safety Products Terminal Blocks Comm. Terminals AS-Interface Specify a key number in place of in the Part No. (T00 to T00) Key wrench for TORX screws (HS9Z-T) is supplied with the interlock switch. Specify an indicator color code in place of ➁ in the Part No. G: green, R: red The contact confi guration shows when the actuator is inserted and locked. is not supplied with the interlock switch, and must be ordered separately. / Key Wrench for TORX Screws Name Specifi cation Part No. Ordering No. Package Quantity Straight HS9Z-AS HS9Z-AS Right-angle HS9Z-AS HS9Z-AS Angle Adjustable (for hinged door) HS9Z-AS HS9Z-AS Key Wrench for TORX Screws HS9Z-T HS9Z-T Conduit Port Plug HS9Z-P HS9Z-P Locking Ring for Gland M0 thread HW9Z-NM0 HW9Z-NM0PN0 When using M0 size gland, order locking ring HW9Z-NM0 separately. Part No. Development Contact Confi guration Main Monitor : NC+NC, NC+NC NC Solenoid Voltage : V DC Indicator Rated Voltage : V DC 0: Without indicator H S E - K MS R P - R Indicator Color G: green R: red Conduit Port Blank: G/ P: PG. Housing Color R: red/black Retention Force MS: 000N* Manual Unlock Key Blank: Without key K: With key H S E - K MS R P - R - T00 Contact Confi guration Main Monitor : NC+NC, NC+NC NC Solenoid Voltage : V DC Indicator Rated Voltage : V DC 0: Without indicator Retention Force MS: 000N* Hostage Key No. T00 to T00 (0 types) Indicator Color Blank: Without indicator G: green R red Conduit Port Blank: G/ P: PG. Housing Color R: red/black Relays & Timers Sockets Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion References * Retention force for horizontal direction (parallel to the mounting panel)

HSE Interlock Switches with Solenoid (-circuit) Ratings Contact Ratings Rated Insulation Voltage (Ui) 00V (between or solenoid and ground: 0V) Rated Thermal Current (Ith).A Rated Voltage (Ue) 0V V 0V Rated Current (Ie) (Note) Main AC DC Resistive load (AC-) A A Inductive Load (AC-) A 0.A Resistive load (DC-) A 0.A 0.A Inductive Load (DC-) A 0.A 0.A Minimum applicable load (reference value): V AC/DC, ma (Applicable range is subject to operating conditions and load.) Solenoid Model HSE HSE-K Rated Voltage V DC (00% duty cycle) Rated Current 9 ma 0 ma Coil Resistance Ω (at 0 C) Ω (at 0 C) Pickup Voltage Rated voltage % maximum (at 0 C) Dropout Voltage Rated voltage 0% minimum (at 0 C) Maximum Continuous Applicable Voltage Rated voltage 0% Maximum Continuous Applicable Time Continuous Insulation Class Class F Indicator Rated Voltage Rated Current Light Source Lens Color The lens cannot be replaced. V DC 0 ma G (green), R (red) Specifications UL0 (UL listed) CSA C., No. (c-ul listed) ISO 9 EN 0 (TÜV approval) Applicable Standards IEC 09-- EN 09-- (TÜV approval) GS-ET-9 (BG approval) GB0. (CCC approval) IEC 00-/EN 00- (applicable standards for use) Operating Temperature 0 to 0 C (no freezing) Relative Humidity to % (no condensation) Storage Temperature 0 to +0 C (no freezing) Pollution Degree Impulse Withstand Voltage kv (between or solenoid and grounding:. kv) Insulation Resistance (00V DC megger) Between live and dead metal parts: 00 MΩ minimum Between live metal part and ground: 00 MΩ minimum Between live metal parts: 00 MΩ minimum Between terminals of the same pole: 00 MΩ minimum Electric Shock Class II (IEC 0) Degree of IP (IEC 09) Shock Resistance Damage limits: 000 m/s Vibration Resistance Operating Speed Direct Opening Travel Direct Opening Force Retention Force Operating Frequency Mechanical Life Electrical Life Conditional Short-circuit Current Weight (approx.) Operating extremes: 0 to Hz, amplitude 0. mm Damage limits: 0 Hz, amplitude. mm 0.0 to.0 m/s mm minimum 0N minimum 000N minimum (GS-ET-9) (00N in the direction vertical to the mounting panel) 900 operations per hour,000,000 operations minimum (GS-ET-9) 0,000 operations minimum (key operation) 00,000 operations minimum (rated load),000,000 operations minimum (V AC/DC, 00mA, operating frequency 900 operations per hour) 0A (0V) (Use 0V/0A fast-blow fuse for short-circuit protection.) 00g Example of Safety + Monitoring using -circuit Interlock Switches (safety category ) Before operation of the following circuit, it is recommended for the entire safety-related system to undergo a third party evalu ation. L V DC F ESC: External Start Condition ESC K K S S: Start Switch (HW Series Momentary) A S S S9 S Safety Relay Module (HRS-AF) A S S S S S S S, S: Unlocking Switch (effective after the hazard source has stopped) + COM0 0 DC DC. IN PLC (FCA MicroSmart) Ry. OUT COM 0 PL PL Interlock Switch Monitor K K External Output K K HSE Series Solednoid Interlock Switches (-circuit) K, K: Relay/Contactor (forced guide contact) N

HSE HSE Interlock Switches with Solenoid (-circuit) Dimensions HSE Horizontal Mounting Straight (HS9Z-AS) 0 Horizontal Mounting Straight (HS9Z-AS) Flush Silhouette Switches & Pilot Lights Lights 0 RP: Mounting Reference Position (.0) (.0 ±0.*). 9. 0. [RP] 9. 0 (.±0.*). [RP] -M Mounting Holes Slot Plug (Note) HSE-K Horizontal Mounting Straight (HS9Z-AS) 0... 9. 9 0.. 9 Cover HS9Z-AS Cushion Sponge 9 -M Screws Mounting Hole Layout ±0.*.. ±0.* (. [RP]). (. [RP]) Cover HS9Z-AS Cushion Sponge Note: Plug the unused actuator entry slot using the slot plug supplied with the interlock switch. Use three mounting screws to mount the interlock switch according to the mounting hole layout. * center position Horizontal Mounting Straight (HS9Z-AS) Illumination Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers 0 (.0) (.0 ±0.*). 9. 0. [RP] 9. 0 (. ±0. *). [RP] -M Mounting Holes Slot Plug (Note) 0... 9. 9.. 9 Cover HS9Z-AS Cushion Sponge 9 -M Screws ±0.*.. ±0. (. [RP]). Mounting Hole Layout Mounting Reference Position As shown in the fi gure on the right, the mounting reference position of the actuator when inserted in the interlock switch is: The actuator cover lightly touches the interlock switch. After mounting the actuator, remove the actuator cover from the actuator. Dimensions -M Screws ø.0 9 9. 0. 9. -M Screws ø (.) 0.... 0. (. [RP]) Interlock Switch Cover Cover HS9Z-AS Cushion Sponge Note: Plug the unused actuator entry slot using the slot plug supplied with the interlock switch. Use three mounting screws to mount the interlock switch according to the mounting hole layout. * center position Straight (HS9Z-AS) Right-angle (HS9Z-AS) Angle Adjustable (HS9Z-AS) (Note) Stop Film (attached) Stop Stop Sockets Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion References 0. 0.. Mounting Holes When installed () ø. Cover (gray). Mounting Holes Note: The actuator cover and actuator stop fi lms are supplied with the actuator and used when adjusting the actuator position. Remove the actuator cover and actuator stop fi lm after the actuator position is determined. ø. When installed () 90 Cover (gray). max. () 0 hinge Angle Adjustment Screw (M hexagon socket head screw) 0 0 R. -M Screws Mounting Holes

HSE Interlock Switches with Solenoid (-circuit) Diagrams and Operating Characteristics Spring Lock HSE- MSR- (Main : NC+NC, NC+NC, Monitor : NC) Status Status Machine ready to operate Solenoid de Interlock Switch Status Status Solenoid Status Solenoid Manual Unlock Solenoid de Solenoid de UNLOCK Diagram Contact Configuration Monitor Lock Monitor ( inserted) (Solenoid OFF) Main : Main : Monitor : Main Monitor -: Closed Solenoid Power HSE-K -, -: Closed -, -: Open -, -: Open -, -: Open -, -: Open -: Open -: Open -: Open -: Open -: Power ON -: Power ON -: Power OFF -: Power OFF -: Power OFF MSR- (Main : NC+NC, NC+NC, Monitor : NC) Status Status Interlock Switch Status Status Status Status Status closed Key is Key is installed Key is removed Key is removed Key is removed removed Solenoid Solenoid Solenoid de Solenoid Solenoid de- de- Key is installed Solenoid de- Diagram Solenoid is. Switch is OFF. Removing the key maintains Removing the key maintains Removing the key maintains the switch in OFF status the switch in OFF status the switch in OFF status Removing the key maintains the switch in OFF status -, -: Open -, -: Open -, -: Open -, -: Open -, -: Open -: Open -: Open -: Open -: Open -: Open -: Power ON -: Power OFF -: Power OFF -: Power OFF Contact Configuration Monitor Lock Monitor ( inserted) (Solenoid OFF) -, -: Closed Main : Main : Monitor : Main Monitor -: Closed Solenoid Power -: Power OFF -: Power ON Remarks locked Key retained Machine ready to operate locked can be can be Key removable opened Machine Machine opened Machine Machine cannot operate cannot operate Machine cannot operate cannot operate cannot operate Main circuit: Connected to the machine drive control circuit, sending interlock signals to the protective door. Monitor circuit: Sends ON/OFF signals of the main circuit and monitoring signals of open/closed status of the protective door. Operation Characteristics (reference) 0 ( insertion position). (Locked position) 0.0 (Approx. travel in mm).0 0.0 Main Monitor ( open, NO) Monitor ( closed,nc) Lock Monitor (Unlocked, NO) Lock Monitor (Locked, NC) Contacts ON (closed) Contacts OFF (open) The operation characteristics show the contact status when the actuator enters into the center of the entry slot. The circuit No. - and - are interconnected. Use circuits - and - for safety circuits.

HSE HSE Interlock Switches with Solenoid (-circuit) Safety Precautions In order to avoid electric shock or fi re, turn power off before installation, removal, wire connection, maintenance, or inspec tion of the interlock switch. If relays are used in the circuit between the interlock switch and the load, consider the danger and use safety relays, since welded or sticking contacts of standard relays may invalidate the functions of the interlock switch. Perform risk assessment and establish a safety circuit which satisfi es the requirement of the safety category. Instructions Regardless of door types, do not use the interlock switch as a door stop. Install a mechanical door stop at the end of the door to protect the interlock switch against excessive force. For HSE-K, do not apply excessive force to the locked key. Applying force to the key may interfere with solenoid operation, resulting in a failure to unlock. Also, applying a torque larger than. N m to the key results in damage. Do not apply excessive shock to the interlock switch when opening or closing the door. A shock to the interlock switch exceeding,000 m/s may cause damage to the interlock switch. When wiring, unscrew the cover with part number label only. Unnecessary loosening of other screws may cause a malfunc tion of the interlock switch. Prevent foreign objects such as dust and liquids from entering the interlock switch while connecting a conduit or wiring. If the operating atmosphere is contaminated, use a protective cover to prevent the entry of foreign objects into the interlock switch through the actuator entry slots. Entry of a considerable amount of foreign objects into the interlock switch may affect the mechanism of the interlock switch and cause a malfunction. Plug the unused actuator entry slot using the slot plug supplied with the interlock switch. Do not store the interlock switch in a dusty, humid, or organicgas atmosphere. Use dedicated actuators only. When other actuators are used, the interlock switch may be damaged. Do not modify the actuator, otherwise it will damage the interlock switch. The cover uses special screws which cannot be removed or tightened by general drivers. Use the special wrench supplied with the interlock switch. Regardless of door types, do not use the interlock switch as a door lock. Install a separate lock using a latch or other measures. While the solenoid is, the interlock switch temperature rises to approximately 00 C (HSE-J: C). Do not touch to prevent burns. If cables come into contact with the interlock switch, use heat-resistant cables. The solenoid has polarity. Make sure of the correct polarity when wiring. Do not apply overvoltage, otherwise the solenoid will be burnt. retention force is 000N (static load). When larger force is expected, add a system using interlock switch without lock (ex. HSD) and sensor in order to detect door opening and to stop the machine. Minimum Radius of Hinged When using the interlock switch for a hinged door, refer to the minimum radius of doors shown on the right. For the doors with small minimum radius, use angle adjustable actuators (HS9Z-AS). Note: Because deviation or dislocation of hinged door may occur in actual applications, make sure of the correct operation before installation. Do not place a PLC in the circuit between the interlock switch and the load. Safety security can be endangered in the event of a malfunction of the PLC. Do not disassemble or modify the interlock switch, otherwise a malfunction or an accident may occur. Do not install the actuator in the location where the human body may come into contact. Otherwise injury may occur. HS9Z-AS (w/rubber cushions) When the door hinge is on the extension line of the interlock switch surface: 0 mm Hinge 0 mm Hinge When the door hinge is on the extension line of the actuator mounting surface: 0 mm Hinge HS9Z-AS 0 mm HS9Z-AS Hinge When the door hinge is on the extension line of the interlock switch surface: 0mm When the door hinge is on the extension line of the actuator mounting surface: 0mm 0 mm Angle Adjustment 0 mm HS9Z-AS Using the angle adjustment screw, the actuator angle can be adjusted (refer to the dimensional drawing). Adjustable angle: 0 to 0 The larger the adjusted angle of the actuator, the smaller the applicable radius of the door opening. After installing the actuator, open the door. Then adjust the actuator so that its edge can be inserted properly into the actuator entry slot of the interlock switch. Recommended tightening torque of angle adjustable screw: 0. N m After adjusting the actuator angle, apply Loctite to the adjustment screw so that the screw will not move. Flush Silhouette Switches & Pilot Lights Lights Illumination Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion References

HSE Interlock Switches with Solenoid (-circuit) Instructions Mounting Examples Mount the interlock switch on a fi xed machine or guard, and mount the actuator on the hinged door. Do not mount both interlock switch and actuator on the hinged doors, otherwise malfunction will occur. Application on Sliding s HSE Interlock Switch HS9Z-AS Latch Stop Application on Hinged s HS9Z-AS HSE Interlock Switch Manual Unlocking (HSE) Latch HS9Z-AS The HSE allows manual unlocking of the actuator to precheck proper entry of the actuator into the slot as well as for emergency use such as a power failure. With Manual Unlock Key When locking or unlocking the interlock switch manually, turn the key fully using the special manual unlock key supplied with the interlock switch. Using the interlock switch with the key not fully turned (less than 90 ) may cause damage to the interlock switch or operation failures (when manually unlocked, the interlock switch will keep the main circuit disconnected and the door unlocked). Do not apply excessive force to the manual unlock part, otherwise the manual unlock part will become damaged. Do not leave the manual unlock key attached to the interlock switch during operation. This is dangerous because the interlock switch can always be unlocked while the machine is in operation. Unlock Normal Position Unlock Manual Unlocking Position Note: The unlocking method is intended for an escape from a machine when an operator is locked in. For access to the unlocking entry, an access hole is needed in the mounting panel. When opening the hole, apply proper protection against water or other foreign objects. Caution For manual unlock type, make sure that the machine has come to a complete stop before unlocking the interlock switch manually. Manual unlocking during machine operation loses the function of solenoid lock interlock switch. Manual Unlocking by Hostage Key (HSE-K) The HSE-K has a hostage key for manual unlocking of the actuator to precheck proper entry of the actuator into the slot as well as for emergency use such as a power failure. Remove the screw located on the front Screwdriver of the interlock switch using the special wrench supplied with the interlock switch. Insert a small screwdriver into the hole to push the lever inside the ➀ interlock switch away from the hostage key until the key is unlocked. ➁ Turn the hostage key to UNLOCK side to unlock the actuator as shown on the right. Note: Before manually unlocking the interlock switch, make sure that the machine has come to a complete stop. Manual unlocking during operation may unlock the interlock switch before the machine stops, and the function of interlock switch is lost. After unlocking, install the screw. Opening/Closing the Cover (HSE-K) For safety, make sure that the power is turned off before opening or closing the cover. When opening the interlock switch cover, remove the screws of the cover only. Do not remove other screws, otherwise failure of inter lock switch will be caused. The cover uses special screws which cannot be removed or tightened by general drivers. Use the special wrench supplied with the interlock switch. When wiring, make sure that any liquid such as water and oil does not enter the interlock switch. Close the cover in the following method.. Turn the key to LOCK position.. Close the door (actuator is inserted).. Turn the white plastic part in the interlock switch clockwise until the plastic part comes to the position shown in the fi gure below.. Close the cover and tighten the screws to the appropriate torque. Without Manual Unlock Key Remove the screw located on the side of the interlock switch using the special wrench supplied with the interlock switch. Insert a small screwdriver into the interlock switch to push the lever inside of the inter lock switch toward the indicator until the actuator is unlocked (see the fi gure on the right). Common Unlocking Operation Screwdriver Cover Attached Accessories L-shaped Wrench Part No.: HS9Z-T ➀ ➂ Insert a small screwdriver into the elliptical hole on the back of the interlock switch, then push the lever inside the interlock switch toward the indicator until the actua tor is unlocked. White Plastic ➁ closed (actuator inserted)

HSE HSE Interlock Switches with Solenoid (-circuit) Instructions Applicable Crimping Terminal. min. ø. min. Use an insulation tube on the crimping terminal. When using stranded wires, make sure that loose wires do not cause short circuit. Also, do not solder the terminal to prevent loose wires. Applicable Wire Size 0. to. mm Applicable Cable Glands Use IP cable gland. When using M0-size cable gland, use locking ring HW9Z-NM0. When Using Flexible Conduits (Example) Flexible conduit example: VF-0 Conduit Port Size Plastic Cable Gland Metal Cable Gland G/ PG. M0 (Note ) When Using Multi-core Cables (Example) RLC-0 RBC-0PG. RLC-0EC0 Conduit Port Size Plastic Cable Gland Metal Cable Gland G/ PG. M0 (Note ).9 max.. max. 9 mm max. Wire Approx. Insulation Tube G/, PG., M0 SCS-0 (Seiwa Electric) ST. (K-MECS) ST-M0X. (K-MECS) (Note ) ALS- ABS- PG. ALS- EC0 Different cable glands are used depending on the cable sheath outside diameter. When purchasing a cable gland, confi rm that the cable gland is applicable to the cable sheath outside diameter. Note : When using M0 cable gland, order HW9Z-NM0 locking ring and replace with the locking ring installed in the HSE interlock switch. Note : When using ST-M0X. cable gland, use together with a gasket (Part No.: GPM0, K-MECS). 0 mm max. Applicable Crimping Terminal Recommended Tightening Torque of Mounting Screws Interlock switch:. to. N m (three M screws) Lid mounting screw: 0.9 to. N m (M screw) Terminal screw: 0.9 to. N m (M. screw) Connector:. to. N m s HS9Z-AS:. to. N m (two M screws) HS9Z-AS/AS:. to. N m (two M screws) Mounting bolts must be provided by users. The above recommended tightening torques of the mounting screws are the values confi rmed with hex socket head bolts. When other screws are used and tightened to a smaller torque, make sure that the screws do not come loose after mounting. Mounting bolts must be provided by the users. To avoid unauthorized or unintended removal of the interlock switch and the actuator, it is recommended that the interlock switch and the actuator be installed in an unremovable manner, for example using special screws or welding the screws. Conduit Port Opening Make an opening for wire connection by breaking one of the conduit-port knockouts on the interlock switch housing using a screwdriver. When breaking the conduit port, take care not to damage the contact block or other parts inside the interlock switch. Cracks or burrs on the conduit entry may deteriorate the housing protection against water. When changing to another conduit port, close the unused opening with an optional plug (Part No.: HS9Z-P). Plug Part No. HS9Z-P Flush Silhouette Switches & Pilot Lights Lights Illumination Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors Control Stations Explosion References 9