D4GL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key

Similar documents
D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

D4NL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key \ Lead-free, Environment-friendly Design

D4NL. Guard Lock Safety-door Switch. Best-selling Guard Lock Safety-door Switch Available in Several Compact, Multi-contact Models

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

D4NL CSM_D4NL_DS_E_9_2

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

D4BL. Guard Lock Safety-door Switch

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

Safety-door Switch. Ordering Information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

Hinged Safety Door Switch

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock

D4GL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key \

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Manual Reset Limit Switch

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Safety Interlock Switches

D4JL. Guard Lock Safety-door Switch. World's Top * Holding Force of 3,000 N. Features

Safety Limit Switch

D4NS. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Safety-door Switch. Model Number Structure

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

D4BL. Guard Lock Safety-door Switch

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D4GS-N CSM_D4GS-N_DS_E_7_2

D4BS CSM_D4BS_DS_E_8_4

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D4NL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key \ Lead-free, Environment-friendly Design

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

2NC (slow-action) Direct. Model. opening

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

D4NL. Guard Lock Safety-door Switch. Best-selling Guard Lock Safety-door Switch Available in Several Compact, Multi-contact Models

CSM_D4N-_R_DS_E_6_1

D4NH CSM_D4NH_DS_E_7_1

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

D4SL-N /

2NC (slow-action) Direct. Model. opening

Machine & Process Safeguarding Solution Selection Guide

Safety Limit Switch

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Clicks for Three Easily Discernable Positions

Safety Guard Switching Unit G9SX-GS

Safety Switches & Operator Controls

Lock and release types. Solenoid: 24 VDC Mechanical lock 2NC/1NO+1NC/1NO M20 D4NL-4EDA-B4-NPT

F3S-TGR-KM15/-KM16/-KH16

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

SG-B1 SERIES / SG-A1 SERIES

D4SL-N /

Model Number Structure

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

A4EG CSM_A4EG_DS_E_6_1

F3S-TGR-KHL1/-KHL3/-KHL3R

HS5E Miniature Interlock Switches with Solenoid

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Small Limit Switch D4V

A22LK CSM_A22LK_DS_E_6_2

HS1L Interlock Switches with Solenoid

HS1C Interlock Switches with Solenoid

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

HS5D Miniature Interlock Switches

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

HS5D Miniature Interlock Switches

HS1E-K Interlock Switches with Solenoid (3-circuit)

Model Number Structure

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

A22NK. Key-type Selector Switches

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

Tactile Switch (Hinged Type)

HS1E Series Full Size Solenoid Locking Switches

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

Safety switches with solenoid and separate actuator

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

HS1E Series Full Size Interlock Switch with Locking Solenoid

Model Number Structure

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

Safety Interlock Switches

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Door Interlock Switches

Transcription:

Guard Lock Safety-door Switch D4GL Vertically Mounting Guard Lock Safety-door Switch Ideal for Limited Installation Space Selectable Operation Key insertion direction. Slim safety-door switch with an electromagnetic lock or unlock mechanism. Built-in switches with multiple-contact construction are available. A key holding force of 1,000 N minimum. Can be used for either standard loads or microloads. Lineup includes models with a conduit size of. Note: Be sure to read the Safety Precautions on page 361 and the Precautions for All Safety Door Switches on page 317. Model Number Structure Model Number Legend Switch D4GL-@@@@-@@ 1 2 3 4 5 6 1. Conduit Size 1: Pg13.5 2: G1/2 4: 2. Built-in Switch (with Door Open/Closed Detection Switch and Lock Monitor Switch Contacts) A: 1NC/1NO slow-action contacts plus 1NC/1NO slow-action contacts B: 1NC/1NO slow-action contacts plus 2NC slow-action contacts C: 2NC slow-action contacts plus 1NC/1NO slow-action contacts D: 2NC slow-action contacts plus 2NC slow-action contacts E: 2NC/1NO slow-action contacts plus 1NC/1NO slow-action contacts F: 2NC/1NO slow-action contacts plus 2NC slow-action contacts G: 3NC slow-action contacts plus 1NC/1NO slow-action contacts H: 3NC slow-action contacts plus 2NC slow-action contacts 3. Head Mounting Direction and Material F: Four mounting directions possible (Front-side mounting at time of delivery)/plastic 4. Door Lock and Release A: Mechanical lock/24-vdc solenoid release G: 24-VDC solenoid lock/mechanical release 5. Indicator B: 24 VDC (orange/green LED indicator) 6. Release Key Type Blank: Standard release key 4: Special release key Operation Key \ D4DS-K@ 1 1. Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (horizontal) 5: Adjustable mounting (horizontal/vertical) Guard Lock Safety-door Switch D4GL 349

Ordering Information List of Models Switches (Operation Keys are sold separately.) : Models with certified direct opening contacts. Head material Release key type Solenoid voltage/ indicator Plastic Standard Solenoid: 24 VDC Orange/green LED: 24 VDC Lock and release types Mechanical lock Solenoid release Solenoid lock Mechanical release Contact configuration (door open/closed detection switch and lock monitor switch contacts) (slow-action) Certified direct opening NC contact Conduit size Model 1NC/1NO+1NC/1NO Pg13.5 D4GL-1AFA-A G1/2 D4GL-2AFA-A D4GL-4AFA-A 1NC/1NO+2NC Pg13.5 D4GL-1BFA-A G1/2 D4GL-2BFA-A D4GL-4BFA-A 2NC+1NC/1NO Pg13.5 D4GL-1CFA-A G1/2 D4GL-2CFA-A D4GL-4CFA-A 2NC+2NC Pg13.5 D4GL-1DFA-A G1/2 D4GL-2DFA-A D4GL-4DFA-A 2NC/1NO+1NC/1NO Pg13.5 D4GL-1EFA-A G1/2 D4GL-2EFA-A D4GL-4EFA-A 2NC/1NO+2NC Pg13.5 D4GL-1FFA-A G1/2 D4GL-2FFA-A D4GL-4FFA-A 3NC+1NC/1NO Pg13.5 D4GL-1GFA-A G1/2 D4GL-2GFA-A D4GL-4GFA-A 3NC+2NC Pg13.5 D4GL-1HFA-A G1/2 D4GL-2HFA-A D4GL-4HFA-A 1NC/1NO+1NC/1NO Pg13.5 D4GL-1AFG-A G1/2 D4GL-2AFG-A D4GL-4AFG-A 1NC/1NO+2NC Pg13.5 D4GL-1BFG-A G1/2 D4GL-2BFG-A D4GL-4BFG-A 2NC+1NC/1NO Pg13.5 D4GL-1CFG-A G1/2 D4GL-2CFG-A D4GL-4CFG-A 2NC+2NC Pg13.5 D4GL-1DFG-A G1/2 D4GL-2DFG-A D4GL-4DFG-A 2NC/1NO+1NC/1NO Pg13.5 D4GL-1EFG-A G1/2 D4GL-2EFG-A D4GL-4EFG-A 2NC/1NO+2NC Pg13.5 D4GL-1FFG-A G1/2 D4GL-2FFG-A D4GL-4FFG-A 3NC+1NC/1NO Pg13.5 D4GL-1GFG-A G1/2 D4GL-2GFG-A D4GL-4GFG-A 3NC+2NC Pg13.5 D4GL-1HFG-A G1/2 D4GL-2HFG-A D4GL-4HFG-A 350 Guard Lock Safety-door Switch D4GL

Head material Plastic Release key type Special release key Solenoid voltage/ indicator Solenoid: 24 VDC Orange/green LED: 24 VDC Lock and release types Mechanical lock Solenoid release Solenoid lock Mechanical release Contact configuration (door open/closed detection switch and lock monitor switch contacts) (slow-action) Certified direct opening NC contact Conduit size Model 1NC/1NO+1NC/1NO Pg13.5 D4GL-1AFA-A4 G1/2 D4GL-2AFA-A4 D4GL-4AFA-A4 1NC/1NO+2NC Pg13.5 D4GL-1BFA-A4 G1/2 D4GL-2BFA-A4 D4GL-4BFA-A4 2NC+1NC/1NO Pg13.5 D4GL-1CFA-A4 G1/2 D4GL-2CFA-A4 D4GL-4CFA-A4 2NC+2NC Pg13.5 D4GL-1DFA-A4 G1/2 D4GL-2DFA-A4 D4GL-4DFA-A4 2NC/1NO+1NC/1NO Pg13.5 D4GL-1EFA-A4 G1/2 D4GL-2EFA-A4 D4GL-4EFA-A4 2NC/1NO+2NC Pg13.5 D4GL-1FFA-A4 G1/2 D4GL-2FFA-A4 D4GL-4FFA-A4 3NC+1NC/1NO Pg13.5 D4GL-1GFA-A4 G1/2 D4GL-2GFA-A4 D4GL-4GFA-A4 3NC+2NC Pg13.5 D4GL-1HFA-A4 G1/2 D4GL-2HFA-A4 D4GL-4HFA-A4 1NC/1NO+1NC/1NO Pg13.5 D4GL-1AFG-A4 G1/2 D4GL-2AFG-A4 D4GL-4AFG-A4 1NC/1NO+2NC Pg13.5 D4GL-1BFG-A4 G1/2 D4GL-2BFG-A4 D4GL-4BFG-A4 2NC+1NC/1NO Pg13.5 D4GL-1CFG-A4 G1/2 D4GL-2CFG-A4 D4GL-4CFG-A4 2NC+2NC Pg13.5 D4GL-1DFG-A4 G1/2 D4GL-2DFG-A4 D4GL-4DFG-A4 2NC/1NO+1NC/1NO Pg13.5 D4GL-1EFG-A4 G1/2 D4GL-2EFG-A4 D4GL-4EFG-A4 2NC/1NO+2NC Pg13.5 D4GL-1FFG-A4 G1/2 D4GL-2FFG-A4 D4GL-4FFG-A4 3NC+1NC/1NO Pg13.5 D4GL-1GFG-A4 G1/2 D4GL-2GFG-A4 D4GL-4GFG-A4 3NC+2NC Pg13.5 D4GL-1HFG-A4 G1/2 D4GL-2HFG-A4 D4GL-4HFG-A4 Guard Lock Safety-door Switch D4GL 351

Operation Keys (Order Separately) Horizontal mounting Type Model D4DS-K1 Vertical mounting D4DS-K2 Adjustable mounting (Horizontal) D4DS-K3 Adjustable mounting (Horizontal/Vertical) D4DS-K5 Specifications Standards and EC Directives Machinery Directive Low Voltage Directive EN1088 EN60204-1 GS-ET-19 Certified Standard Ratings TÜV (EN60947-5-1), CCC (GB14048.5) Utilization AC-15 DC-13 Item category Rated operating current (I e ) 0.75 A 0.27 A Rated operating voltage (U e ) 240 V 250 V Note: Use a 10-A fuse type gi or gg that conforms to IEC60269 as a short- protection device. UL/CSA (UL508, CSA C22.2 No. 14) C300 Rated Carry current Current Volt-amperes voltage Make Break Make Break 120 VAC 2.5 A 15 A 1.5 A 1,800 VA 180 VA 240 VAC 7.5 A 0.75 A Certified Standards Certification body Standard File No. TÜV Product Service Note: 1. Consult your OMR representative for details. 2. Certification for CSA C22.2 No. 14 is authorized by the UL mark. 3. Ask your OMR representative for information on certified models. Q300 EN60947-5-1 (certified direct opening) Solenoid Coil Characteristics Indicator Characteristics (See note 1.) UL (See note 2.) UL508, CSA C22.2 No.14 E76675 CQC (CCC) GB14048.5 2003010305064 264 Rated Carry current Current Volt-amperes voltage Make Break Make Break 125 VAC 2.5 A 0.55 A 0.55 A 69 VA 69 VA 250 VAC 0.27 A 0.27 A Item Rated operating voltage (100% ED) Current consumption Insulation Item Rated voltage Current leakage Color (LED) 24 VDC ±10% 24 VDC Approx. 200 ma Class F (130 C max.) 24 VDC Approx. 3 ma Orange/Green LED 352 Guard Lock Safety-door Switch D4GL

Characteristics Degree of protection (See note 3.) Durability (See note 4.) Mechanical Electrical IP67 (EN60947-5-1) (This applies for the Switch only. The degree of protection for the key hole is IP00.) 1,000,000 operations min. 500,000 operations min. for a resistive load of 4 ma at 24 VDC; 150,000 operations min. for a resistive load of 1 A at 125 VAC in 2 s and 4 ma at 24 VDC in 2 s (See note 5.) Operating speed 0.05 to 0.5 m/s Operating frequency 30 operations/minute max. Rated frequency 50/60 Hz Contact gap 2 x 2 mm min. Direct opening force (See note 6.) 60 N min. (EN60947-5-1) Direct opening travel (See note 6.) 10 mm min. (EN60947-5-1) Holding force (See note 7.) 1,000 N min. Insulation resistance 100 MΩ min. (at 500 VDC) Minimum applicable load (See note 8.) Resistive load of 4 ma at 24 VDC (N-level reference value) Rated insulation voltage (U i ) 300 V (EN60947-5-1) Conventional enclosed thermal current (I the ) 2.5 A (EN60947-5-1) Impulse withstand voltage (EN60947-5-1) Between terminals of the same polarity 2.5 kv Between terminals of different polarities 4 kv Between solenoid and uncharged metallic parts 0.8 kv Between other terminals and uncharged metallic parts and 4 kv between other terminals and ground Conditional short- current 100 A (EN60947-5-1) Pollution degree (operating environment) 3 (EN60947-5-1) Protection against electric shock Class II (double insulation) Closed- counterelectromotive force 1,500 V max. (EN60947-5-1) Contact resistance 100 mω max. (initial value) Vibration Malfunction 10 to 55 Hz, 0.75-mm single amplitude resistance Shock resistance Destruction 1,000 m/s 2 min. Malfunction 300 m/s 2 min. Ambient temperature Operating: 10 C to 55 C with no icing Ambient humidity Operating: 95% max. Weight Approx. 400 g (D4GL-1AFA-A) Note: 1. The above values are initial values. 2. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. 3. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4GL in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. 4. The durability is for an ambient temperature of 5 C to 35 C and an ambient humidity of 40% to 70%. For more details, consult your OMR representative. 5. If the ambient temperature is greater than 35 C, do not pass the 1-A, 125-VAC load through more than 2 s. 6. These figures are minimum requirements for safe operation. 7. This figure is based on the GS-ET-19 evaluation method. 8. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand. Guard Lock Safety-door Switch D4GL 353

Connections Contact Form Indicates conditions where the Key is inserted and the lock is applied. Terminals 12 and 41 are connected internally (as per BIA GS-ET-19). Model Contact Contact form (door open/closed detection switch and lock monitor switch contacts) D4GL-@AF@-@ D4GL-@BF@-@ D4GL-@CF@-@ D4GL-@DF@-@ D4GL-@EF@-@ D4GL-@FF@-@ D4GL-@GF@-@ D4GL-@HF@-@ 1NC/1NO + 1NC/1NO 1NC/1NO + 2NC 2NC + 1NC/1NO 2NC + 2NC 2NC/1NO + 1NC/1NO 2NC/1NO + 2NC 3NC + 1NC/1NO 3NC + 2NC Zb 33 34 Zb 12 41 42 53 54-42 33-34 53-54 Zb Zb -42 12 41 42 33-34 51-52 33 34 51 52 Stroke Operation Key insertion completion position Operating pattern Lock position Lock position Operation Key insertion completion position Zb Zb -42 12 41 42 21-22 53-54 21 22 53 54 Zb Zb -42 12 41 42 21-22 51-52 21 22 51 52 Stroke Lock position Stroke Operation Key insertion completion position Lock position Stroke Operation Key insertion completion position Lock position Zb Zb -42 21 12 22 41 53 42 54 21-22 33-34 53-54 33 34 Stroke Operation Key insertion completion position Lock position Zb Zb -42 21 12 22 41 51 42 52 21-22 33-34 51-52 33 34 Stroke Operation Key insertion completion position Lock position Zb Zb -42 21 12 22 41 53 42 54 21-22 31-32 53-54 31 32 Stroke Operation Key insertion completion position Lock position Zb Zb -42 21 12 22 41 51 42 52 21-22 31-32 51-52 31 32 Stroke Operation Key insertion completion position Extraction completion position Extraction completion position Extraction completion position Extraction completion position Extraction completion position Extraction completion position Extraction completion position Extraction completion position Remarks Only NC contact -12 has a certified direct opening mechanism. The terminals -42, 33-34, and 53-54 can be used as unlike poles. Only NC contact -12, has a certified direct opening mechanism. The terminals -42, 33-34, and 51-52 can be used as unlike poles. Only NC contacts -12 and 21-22 have a certified direct opening mechanism. The terminals -42, 21-22, and 53-54 can be used as unlike poles. Only NC contacts -12 and 21-22 have a certified direct opening mechanism. The terminals -42, 21-22, and 51-52 can be used as unlike poles. Only NC contacts -12 and 21-22 have a certified direct opening mechanism. The terminals -42, 21-22, 33-34, and 53-54 can be used as unlike poles. Only NC contacts -12 and 21-22 have a certified direct opening mechanism. The terminals -42, 21-22, 33-34, and 51-52 can be used as unlike poles. Only NC contacts -12, 21-22, and 31-32 have a certified direct opening mechanism. The terminals -42, 21-22, 31-32, and 53-54 can be used as unlike poles. Only NC contacts -12, 21-22, and 31-32 have a certified direct opening mechanism. The terminals -42, 21-22, 31-32, and 51-52 can be used as unlike poles. 354 Guard Lock Safety-door Switch D4GL

Indicator Internal Circuit Diagram LED LED (Green) (Orange) D D Green (+) Orange (+) CRD CRD ZD ZD 5 to 24V DC COM ( ) Circuit Connection Example Terminals 12 and 41 are connected internally and so connect terminals and 42 for safety- input. (BIA GS-ET-19) Connect terminals 21 and 22 and terminals 51 and 52 in series when using as safety- input (redundancy for terminals and 12 and terminals 41 and 42 above). Connect the terminals individually when using as auxiliary- input (e.g., terminals 21 and 22 for safety-door open/closed monitoring and terminals 51 and 52 for monitoring the lock status). In the following connection example, terminals 21 and 22 and terminals 51 and 52 are used as auxiliary- input. Connection Example for D4GL-1HFA-A 51 21 31 E1 O1 (Green) 12 41 LED (Green) O2 (Black) 42 52 22 32 E2 Safety Auxiliary Auxiliary Auxiliary O3 (Orange) LED (Orange) Direct opening contacts used as safety- input are indicated with the mark. Terminals and 12 and terminals 21 and 22 are direct opening contacts. Connect the indicators in parallel to the auxiliary s or terminals E1 and E2. Although the 3 lines are connected at the time of delivery, rewire them as necessary for the application. The following table shows the connection configuration required to make the green indicator light when the door is closed and the orange indicator light when the solenoid turns. Indicator Terminal number Lead wire color Green indicator O1 Green 31 Orange indicator O2 Orange E1 Common O3 Black E2 Connected terminal number If an indicator is connected in parallel to a direct opening contact, when the indicator breaks, a short- current will be generated, possibly resulting in an installation malfunction. Do not switch standard loads for more than 2 s at the same time. Otherwise, the level of insulation may decrease. The solenoid has polarity. Be sure to connect terminals with the correct polarity. Guard Lock Safety-door Switch D4GL 355

Operation Method Operation Principles Mechanical lock models Plunger return spring Lock spring LOCK UNLOCK Linking arm The lock plate and monitor switch are linked. Return spring OFF OFF Solenoid lock models Plunger return spring Lock return spring When the door is closed, it is locked by the lock spring. The door will stay locked even if there is a power interruption. UNLOCK The solenoid is released only when the lock is turned. LOCK Linking arm The lock plate and monitor switch are linked. Return spring OFF OFF If the solenoid is OFF, the door will not be locked when it is closed. This means that the door can be opened and closed easily when replacing workpieces or parts. The door is locked only when the solenoid is turned. This means that the door will be unlocked if there is a power interruption and so this model cannot be used in systems that would maintain a hazardous state (e.g., systems requiring toxic gases, high temperatures, or gears that would continue to turn due to inertia). Nomenclature Structure Operation key hole Indicator (green) Indicator (orange) Release key Terminal 42 Terminal Terminal 31/33 Terminal 32/34 Conduit opening Terminal E2 ( ) Terminal 21 Terminal 22 Terminal 51/53 Terminal 52/54 Conduit opening Terminal E1 (+) Cover Note: Terminal numbers vary with the model. Confirm terminal numbers by referring to the cover on the back of the Switch. 356 Guard Lock Safety-door Switch D4GL

Dimensions Note: All units are in millimeters unless otherwise indicated. Switches D4GL-@@@@-A D4GL-@@@@-A4 47 40 38 23.5 4.4 34.4 15.3 Four, 5.2-dia. holes 31.5 Four, 9.2-dia. spot facings (depth: 10) Four, LED indicators Release key 84±0.2 (127.5) 148 (187) Cover mounting screw Two, cap screws (3) (21.5) 23.5 (3) 30±0.2 (3) 43 Conduit cap (18.5) 15.3 Four, head mounting screws Head cap Pre-travel distance Operation Key 47.8 40 38 23.5 4.4 34.4 15.3 31.5 Four, 9.2-dia. spot facings (depth: 10) Four, LED indicators Release key 84±0.2 (127.5) 148 (187) Two, cap screws (3) (21.5) 23.5 (3) 30±0.2 (3) 43 Conduit cap (18.5) 15.3 Four, head mounting screws Head cap Pre-travel distance Operation Key Four, 5.2-dia. holes Cover mounting screw Operating characteristics Key insertion force Key extraction force Pre-travel distance Movement before being locked D4GL-@@@@-A 15 N max. 40 N max. 10 mm max. 4 mm min. Operating characteristics Key insertion force Key extraction force Pre-travel distance Movement before being locked D4GL-@@@@-A4 15 N max. 40 N max. 10 mm max. 4 mm min. Guard Lock Safety-door Switch D4GL 357

Operation Keys Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. D4DS-K1 17.5 28 13 7 4.3 D4DS-K3 14 4 28 15 30 15 7 Four, 2.15R 13 2 Black 13 20 9 dia. 30 40 56 D4DS-K2 10.5 6 9 28 7 30 13 15 D4DS-K5 6.3 20.9 28 4 4.5 dia. 8 dia. 24.6 22.5 Mounting Holes 17 15 4.5 7 2 4. 3 Four, 2.15R 15 41 30 43 55 8 13 41 43 Black 18 6.5 8 1 (7) With Operation Key Inserted D4GL + D4DS-K1 D4GL + D4DS-K2 (38) Horizontal insertion radius: R 200 (38) Horizontal insertion radius: R 200 51.5 min. 54 max. Key insertion position 47.5 min. 50 max. Key insertion position 51.9 (15) Center tolerance of key hole: ±1 47.9 (15) Center tolerance of key hole: ±1 Vertical insertion radius: R 200 Vertical insertion radius: R 200 (31.7) Center tolerance of key hole: ±1 (31.7) Center tolerance of key hole: ±1 D4GL + D4DS-K3 D4GL + D4DS-K5 (38) Horizontal insertion radius: R 50 (38) Horizontal insertion radius: R 50 52.5 min. 55 max. Key insertion position 59.5 min. 62 max. Key insertion position (40) Center tolerance of key hole: ±1 (43) Center tolerance of key hole: ±1 52.9 Normally P52.4 min. 54.9 max. Vertical insertion radius: R 200 59.8 Normally P59.3min. 61.8 max. Vertical insertion radius: R 50 (31.7) Center tolerance of key hole: ±1 (31.7) Center tolerance of key hole: ±1 358 Guard Lock Safety-door Switch D4GL

Application Examples G9SA-321-T + D4GL-@@@A-@ (Mechanical Lock Type) Circuit Diagram (Manual Reset) Lock release signal S4 KM1 KM2 S2 42 41 12 S1: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S2: Guard Lock Safety-door Switch S3: Reset switch S4: Lock release switch KM1 and KM2: Magnetic Contactor M: 3-phase motor Guard Feedback loop OPEN Stop signal TH SA OFF-delay timer Control Timing Chart Limit switch S1 Guard Lock Safety-door Switch S2 Lock release signal Lock release switch S4 Stop signal Reset switch S3 K1 and K2 (NC) K1 and K2 (NO) K3 and K4 (NC) K3 and K4 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO) Operation instruction Motor rotation OFF-delay time Guard opens Operation instruction Guard can be opened Motor controller Note: The above diagram is for Category 3. Guard Lock Safety-door Switch D4GL 359

G9SA-301 (24 VAC/VDC) + D4GL-@@@G-@ (Solenoid Lock Type) Circuit Diagram (Auto-reset) Lock signal S2 32 31 12 S1 Note: 1. This diagram is for Category 4. 2. The lock can be released at any time. Therefore, do not use a model with a solenoid lock in applications where the operator may be exposed to danger when the guard opens. Use a model with a mechanical lock. OPEN 12 Feedback loop KM1 Operation signal KM2 A1 A2 T T12 TH SA a K1 K2 K1 b K2 1 a b T31 T32 13 23 33 41 K1 K2 Control Circuit 3 4 2 5 JP 1 2 3 4 5 6 6 PE T21 T23 T22 A B 14 24 34 42 KM1 KM2 Operation instruction Motor controller Timing Chart Limit switch S1 Guard opens KM1 KM2 Guard Lock Safety-door Switch S2 Operation signal Lock signal K1 and K2 (NC) K1 and K2 (NO) KM1 and KM2 (NC) KM1 and KM2 (NO) M S1: Safety Limit Switch with direct opening mechanism (D4B-N, D4N, D4F) S2: Guard Lock Safety-door Switch KM1 and KM2: Magnetic Contactor M: 3-phase motor 360 Guard Lock Safety-door Switch D4GL

Safety Precautions Refer to the Precautions for All Safety Switches on page 240 and Precautions for All Safety Door Switches on page 317.!CAUTI Precautions for Safe Use Installation Environment Do not use the Switch in locations where explosive or flammable gases may be present. Do not use the Switch submersed in oil or water or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the Switch. (The IP67 degree of protection of the Switch specifies the amount of water penetration after the Switch is submerged in water for a certain period of time.) Although the Switch body is protected from the ingress of dust or water, avoid the ingress of foreign substance through the key hole on the head. Otherwise, accelerated wear or breaking may result. Wiring @ DANGER Always verify the operation of the safety functions before starting the system. Not doing so may result in the safety functions not performing as expected if the wiring or settings are incorrect or the Switches have failed. The system being controlled may continue to operate and possibly cause injury or death. Always ensure that the release key is set to the "LOCK" position before starting the system. If the release key remains set to "UNLOCK", the electromagnetic lock function will not operate and the system may continue to operate, possibly causing injury or death. Always monitor the solenoid NC contact (Terminal -42) in your safety. Do not connect indicator devices (like LED) to safety connected to terminal -42. Before changing the head direction always ensure that the release key is set to "UNLOCK", or that the Operation Key is inserted. Not doing so may damage the Switch and the system may continue to operate, possibly causing injury or death. Refer to Release Key on page 362. Do not apply force exceeding the specified maximum holding force. Doing so may damage the Switch lock mechanism and the system may continue to operate, possibly causing injury or death. Either install another locking component (e.g., a stopper) in addition to the Switch, or use a warning method or indicator to show that the controlled system is locked to avoid overloading the holding force in lock mode. Do not insert the Operation Key when the door is open. The machine may operate, possibly causing injury. Do not use metal conduits or wiring ducts. Electric shock may occasionally occur. Connect a fuse in series with the D4GL to protect it from short damage. The value of the breaking current of the fuse must be calculated by multiplying the rated current by 150% to 200%. When using the D4GL for an EN rating, use a 10-A fuse of type gi or gg that complies with IEC 60269. When switching general loads (125 VAC/1 A), do not operate two s or more at the same time. Otherwise, insulation performance may be degraded. Do not allow the load current to exceed the rated value. Always attach the cover after completing wiring and before using the Switch. Do not supply power when the cover is not attached. Electric shock may occur if the Switch is used without the cover attached. Installation Do not drop the Switch. Doing so may prevent the Switch from functioning to its full capability. Make sure the Switch is mounted securely to prevent it from falling off. Otherwise injury may result. Mount the Operation Key so that it will not come into contact with persons in the area when the door is opened and closed. Injury may result. Do not use a Switch as a stopper. Be sure to install a stopper as shown in the following illustration when mounting the Switch so that the base of the Operation Key does not strike the Head. Stopper Other Precautions Set zone (0.5 to 3 mm) Operation Key Do not attempt to disassemble or modify the Switch. Doing so may cause the Switch to malfunction. The durability of the Switch is greatly influenced by the switching conditions. Always test the switch under actual working conditions before application and use it in a switching for which there are no problems with performance. The user must not maintain or repair equipment incorporating the Switch. Contact the manufacturer of the equipment for any maintenance or repairs required. Guard Lock Safety-door Switch D4GL 361

Precautions for Correct Use The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. Operating Environment This Switch is designed for use indoors. Using the Switch outdoors may damage it. Do not use the Switch where corrosive gases (e.g., H 2 S, SO 2, NH 3, HNO 3, or CI 2 ) are present or in locations subject to high temperature and humidity. Doing so may result in damage to the Switch as a result of contact failure or corrosion. Do not use the Switch in any of the following locations. Locations subject to extreme temperature changes Locations subject to high humidity or condensation Locations subject to excessive vibration Locations where metal dust, processing waste, oil, or chemicals may enter through the protective door Locations subject to detergents, thinners, or other solvents Storage Do not store the Switch where corrosive gases (e.g., H 2 S, SO 2, NH 3, HNO 3, or Cl 2 ) or dust is present, or in locations subject to high temperature or high humidity. Release Key The release key is used to unlock the Switch in case of emergency or if the power supply to the Switch stops. If the release key setting is changed from LOCK to UNLOCK, the lock will be released and the safety door can be opened (mechanical lock models only). After setting the release key to UNLOCK to, for example, perform maintenance, be sure to return it to LOCK setting before resuming operation. Do not use the release key to start or stop machines. The auxiliary lock must be released only by authorized personnel. Do not impose a force exceeding 0.5 N m on the release key screws. The release key may be damaged and may not operate properly. The release key is set in the unlock position at the factory for the D4GL-@@@A and to the lock position for the D4GL-@@@G. To prevent easy release of the auxiliary lock by unauthorized personnel, set it to LOCK and seal it with sealing wax. Figure 1 D4GL-@@@A-@ D4GL-@@@A-@4 D4GL-@@@G-@ D4GL-@@@G-@4 Solenoid Lock Models The solenoid lock locks the door only when power is supplied to the solenoid. Therefore, the door will be unlocked if the power supply to the solenoid stops. Therefore, do not use solenoid lock models for machines that may be operating and dangerous even after the machine stops operating. Mounting Tightening Torque Be sure to tighten each screw of the Switch properly. Loose screws may result in malfunction. Type Terminal screw Cover mounting screw Head mounting screw Operation Key mounting screw Switch mounting screw Connector Switch and Operation Key Mounting Mount the Switch and Operation Key securely to the applicable tightening torque with M5 screws for the Switch and M4 screws for the Operation Key. Always use washers. Do not operate the Switch with anything other than the special OMR Operation Key. Otherwise, the Switch may be damaged and the safety of the system may not be maintained. ] Cap screw Four, M5 30 ±0.1 Ensure that the alignment offset between the Operation Key and the key hole does not exceed ±1 mm. If the Operation Key is offset or at an angle, premature wear or damage to the Switch may result. Observe the specified insertion radius for the Operation Key and insert it in a direction perpendicular to the key hole. Do not impose excessive force on the Key top while the Operation Key is inserted into the Switch body or drop the Switch with the Operation Key inserted. Doing either of these may deform the Key or break the Switch body. Head Direction 84.1±0.1 Tightening torque 0.4 to 0.5 N m 0.5 to 0.7 N m 0.5 to 0.6 N m 2.4 to 2.8 N m 1.3 to 1.5 N m 1.8 to 2.1 N m for other than 1/2-14NPT 1.4 to 1.8 N m for 1/2-14NPT 1.3 to 1.7 N m D4DS-K1/-K2 Two, M4 15 ±0.1 D4DS-K3 D4DS-K5 40 ±0.1 41±0.1 or 43±0.1 Two, M4 Two, M4 Remove the four screws of the head to enable changing the mounting direction of the head. The head can be mounted in four directions. Ensure that no foreign material enters the interior of the Switch. Also, insert the head until the insertion line engraved on the head is hidden by the reference line on the Switch, as shown in the following diagram. Insertion line Hinged Door Reference line If the Switch is mounted too close to the hinge, the force imposed on the lock will be much larger than for locations far from the hinge and the lock may be damaged. Mount the Switch close to the handle. 362 Guard Lock Safety-door Switch D4GL

Securing the Door When the door is closed (with the Operation Key inserted), it may be pulled beyond the set zone because of, for example, the door s weight, or the door cushion rubber. If it is forced open from this condition, the Switch s life may be reduced. If a load is applied to the Operation Key, the door may fail to unlock properly. Use hooks to ensure that the door stays within the set zone. Set zone (0.5 to 3 mm) Operation key Solenoid The solenoid will heat when it carries current. Do not touch it. The solenoid has polarity. Confirm terminal polarity before wiring it. Wiring Precautions Do not wire the Switch while power is being supplied. Doing so may result in electric shock. Do not let particles, such as small pieces of lead wire, enter the switch body when wiring. Applicable lead wire size: AWG24 to AWG22 (0.2 to 0.3 mm 2 ). Use lead wires of an appropriate length. Not doing so may result in excess length causing the cover to rise and not fit properly. Do not push crimp terminals into gaps in the case interior. Doing so may cause damage or deformation of the case. Use crimp terminals that will not interfere with other components inside the case. Recommended Crimp Terminals Manufacturer Model J.S.T. Mfg Co. FN0.5-3 (type F) No. 5-3 (straight) Wiring Circuit Connection Example for the D4GL-@H-@@-A As shown in the following diagram, models are available both with and without an internal connection between terminals 12 and 41. Direct opening contacts used as safety- inputs are indicated with the mark. Terminals and 42, and terminals 21 and 22 have direct opening contacts. Connect terminals 21 and 22 and terminals 51 and 52 in series when using as safety- inputs (redundancy for terminals and 12 and terminals 41 and 42 below). Connect the terminals individually when using as auxiliary- inputs (e.g., terminals 21 and 22 for safety-door open/closed monitoring and terminals 51 and 52 for monitoring the lock status). In the following connection example, terminals 21 and 22 and terminals 51 and 52 are used as auxiliary- inputs. Connect the indicators in parallel to the auxiliary s or terminals E1 and E2. Although the 3 lines are connected at the time of delivery, rewire them as necessary for the application. The following table shows the connection configuration required to make the green indicator light when the door is closed and the orange indicator light when the solenoid turns. Indicator Terminal number Lead wire color Green indicator O1 Green 31 Orange indicator O2 Orange E1 Common O3 Black E2 21 31 E1 O1 (Green) 51 12 41 Indicator (Green) O2 (Green) 42 52 22 32 E2 Safety Auxiliary Auxiliary Auxiliary Connected terminal number The terminal block screws and contact numbers correspond as shown in the following diagram. The numbers are provided on the terminal cover. Confirm terminal numbers against the terminal block terminal symbols when wiring. A B C D E F I G H J A E F I Processing the Conduit Opening Connect a recommended connector to the opening of the conduit and tighten the connector to the proper torque. The case may be damaged if excessive tightening torque is applied. When using a 1/2-14NPT conduit, wind sealing tape around the conduit end of the connector so that the enclosure will conform to IP67. Make sure that the outer diameter of the cable connected to the connector is correct. Attach a conduit cap to the unused conduit opening when wiring and tighten it to a suitable torque. The conduit cap is provided with the Switch. B C D G H J O3 (Orange) Indicator (Orange) O4 (Orange) Guard Lock Safety-door Switch D4GL 363

Recommended Connectors Use a connector with a screw section not exceeding 10 mm. Otherwise the screws will protrude into the case interior. The connectors given in the following table have connectors with screw sections not exceeding 10 mm. Use the following connectors to ensure conformance to IP67. Size Manufacturer Model Applicable cable diameter G 1 / 2 LAPP ST-PF1/2 6.0 to 12.0 mm 5380-1002 OHM ELECTRIC OA-W1609 7.0 to 9.0 mm CO. OA-W16 9.0 to.0 mm Pg13.5 LAPP S-13.5 6.0 to 12.0 mm 5301-5030 LAPP ST- 1.5 53-1020 7.0 to 13.0 mm 1/2-14NPT LAPP ST-NPT1/2 5301-6030 Use LAPP connectors together with Seal Packing (JPK-16, GP- 13.5, or GP), and tighten to the applicable torque. Seal Packing is sold separately. For a 1/2-14NPT conduit, use the above connector after attaching the provided Adaptor to the Switch and wrapping it with sealing tape. Other Precautions Perform maintenance inspections periodically. 6.0 to 12.0 mm ALL DIMENSIS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. C125-E1-05 In the interest of product improvement, specifications are subject to change without notice. 364 Guard Lock Safety-door Switch D4GL