epilog fume extraction solutions

Similar documents
EQUIPMENT. Loctite Bench Top Air Filtration System Plenum Style Part Number Air Filtration System With Arm Part Number

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Users Guide for Ac-sync

Scania Used Vehicle Extended Driveline Warranty

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

User s Manual for Tennessee Chill Box System P/N CB8000

SERIES L1B & L1D LADDERS

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Smart By Design Flexible By Nature

Broadband PowerShield. CP27U Models. User Manual

Videojet Fume Extractor Preventive Maintenance Guide

"Buyer" or "you" means the person, firm or corporation to whom the order is addressed.

Installation Power Management Unit Battery Cables and Battery Harness

Ring Mount Floodgates

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

FREQUENTLY ASKED QUESTION SERIES. BANJO BOLTS WHY THE BAD RAP? 6.0L Powerstroke Diesel. Last Updated: 7/2/2018 Page 1 of 3 S Diesel, LLC

Slimline Duals Installation Instructions Harley-Davidson Touring Models 2009-Current

Euro Lightweight Wheeled Walker

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

2015 & 2018 Fender Brace Installation Instructions

PVI 60KW, PVI 82KW, PVI 95KW

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD

II DISTRIBUTION & SUBSTATION TYPE C

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

AD-7 THERMAL INDICATING AMMETER

Soldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing

Issue 3. Description: ROBINHOOD TAP PULL-OUT SERIES Model Numbers: TPO1200. Model may vary slightly from image pictured

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

EQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number

DALI 650mA LED Driver

1000mA - 650mA Phase Dimmable LED Driver

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

All Terrain Wheeled Walker

650mA Phase Dimmable LED Driver

SPORT COIL SPRINGS Scion xa & xb Part #19412 INSTALLATION OF HOTCHKIS FRONT COIL SPRINGS

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS AND PARTS LIST

ARM-EVAC 50. Benchtop Plenum/Arm Extractor MANUAL NO REV. B

HIGH VOLTAGE DIGITAL AMMETER

Sport Sway Bar Kit UP SCION xb

DESKTOP CONTAINMENT SYSTEM

User Manual SH Slag Removal Tool for use on laser cutting machines with minimum 1.25 between slats

Please read the following key points before installing this kit.

K131. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 4 x 4 x 2. x 2 x 4. Revision No: 2C 1

Loctite Air Filtration System Part Number EQUIPMENT. Operation Manual

Sport Sway Bar Kit Chevy Camaro

30100 Module Installation Guide L

HR-20P Pneumatically Controlled Pressure Regulator

K877. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 1 x 1 x 1. x 2 x 2 x 1 x 1. x 1 x 1. Revision No: 3C 1

Fume Extraction. 22 o C DIGITAL RANGE. 250 m 3 / hr BROCHURE

ROOF BOX INSTRUCTIONS Fitting instructions for Roof Box (EXP1/EXP2)

K440. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 4. x 1 x 1 x 4 x 1. Revision No: 10J 1

PIVOT BUSHING KIT GM F-BODY

P/N# Performance Lowering Springs Installation Instructions

TERMS AND CONDITIONS OF SUPPLY

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

EZ Carrier 3. Owner s Manual. Keep instructions for future reference

SGS Galson Laboratories, Inc. Equipment Rental, FreePumpLoan & FreeSamplingBadges (3-in-1) Agreement

Loctite Control Timer Part Number EQUIPMENT Operation Manual. Control Timer SEC. Technologies

16385 Steering Tie Rods Chrysler A-Body

K327. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 4. Revision No: 5E 1

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Rig Master Power by Mobile Thermo Systems Inc.

AN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References

Camaro / Firebird. Please read the following key points before installing this kit.

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

SERIES DA PORTABLE HOIST

20250 Module Installation Guide

15100 Module Installation Guide Mercedes EPA07 w/dpf

MV Series Motors Operation & Parts Manual

HBC-20 - LED HIGH BAY

Q21 TRACK SYSTEM FOR NISSAN NP300 NAVARA DUAL CAB 2015+

AIR CHAMP PRODUCTS. User Manual. DAP-625S and DAP-875S FORM NO. L D-0914

we make clean air Air Filtration Solutions Industrial Commercial Residential quatroair.com AIR TECHNOLOGIES INC.

PARTS WARRANTY - TERMS AND CONDITIONS

Harley Davidson FL Touring Current Xtreme

User s Manual. Item no. 2561

K708. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 4 x 4. x 4. Revision No: 1A 1

K381W. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 2 x 2. x 4. Revision No: 4C 1

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

MODEL 950C-NP-UV Installation and Owners Manual

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

P/N# Performance Lowering Springs Installation Instructions

Straight-Bore Clutch LSCC-32, 44, 54

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

Further information: Berriman Associates Model 850P.2 Owners Manual

Installation Guide. Marine Filter SURT023M SURT024M

Customer Support

Car Vacuum Cleaner #CarVac

14366, Adjustable Strut Rods Chrysler A-Body Chrysler B-Body Chrysler E-Body

2SHE Series Direct-Drive Shutter Fans

CU6703 Module Installation Guide

Female Plug. connecting to Fuel Quantity

Installation & Service Manual for Portable Fume Collector. Model PFC-800

Do not install and/or operate this safety product unless you have read and understand the safety information contained

K683. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 8 x 2. x 2 x 4 x 4 x 4. x 4. Revision No: 3C 1

Transcription:

epilog fume extraction solutions

epilog fume extraction solutions Our systems ensure hazardous particles and fumes are captured and filtered out before the cleaned air is recirculated back into the production environment. Our cost effective products meet and exceed global health and safety legislation, encouraging green initiatives and environmental good practices.

laser fume extraction By maintaining a dust-free operating area, our systems help to protect valuable equipment, maintain a higher quality mark and reduce the number of rejects and contaminants. iq Operating System Interface Branding Colour matched to laser Advanced Carbon filter HEPA filter technology Connection kit DeepPleat DUO pre filter OUR TECHNOLOGY iq Intelligent (iq) Operating System DeepPleat DeepPleat pre filter DeepPleat DUO DeepPleat DUO pre filter HEPA HEPA filter AFC Automatic flow control technology RFA Reverse flow air technology ACF Advanced carbon filter technology MVS Multi voltage sensing unit PATENTED Patented technology PROTECT ProTECT service plan SureCHECK SureCHECK quality standard

extractor laser zing 18 zing 24 The entry-level laser machines in the Zing series produce anything but entry-level engraving and cutting results. These low-cost desktop units are the perfect choice for someone starting a business or looking to add on a second laser. uml 340 Suitable for a range of lasers, the UML 340 plays on the success of the best in class AD Oracle with its DeepPleat DUO and autovoltage blower in a compact base system. The easi-seal filter location makes filter change easy, quick and safe. This unit has the option of an onboard compressor for a compact installation. 715 x 760 x 600mm 28.1 x 29.9 x 23.6 380m³/hr / 96mbar 223cfm / 96mbar epiloglaser.co.uk/uml-340

mini 18 mini 24 Up your production capabilities with a Legend laser series system. Featuring up to 1200 dpi engraving and servo motors for up to 30% more speed, the Legend laser series includes three popular models: the Epilog Mini 18, Mini 24, and Helix laser systems. uml 340 Suitable for a range of lasers, the UML 340 plays on the success of the best in class AD Oracle with its DeepPleat DUO and autovoltage blower in a compact base system. The easi-seal filter location makes filter change easy, quick and safe. This unit has the option of an onboard compressor for a compact installation. extractor laser 715 x 760 x 600mm 28.1 x 29.9 x 23.6 380m³/hr / 96mbar 223cfm / 96mbar epiloglaser.co.uk/uml-340

extractor laser helix Up your production capabilities with a Legend laser series system. Featuring up to 1200 dpi engraving and servo motors for up to 30% more speed, the Legend laser series includes three popular models: the Epilog Mini 18, Mini 24, and Helix laser systems. ad oracle iq The AD Oracle iq is our most technically advanced laser fume extractor, combining a powerful range of unique features into one compact unit. This versatile unit can be used across a range of laser applications and the revolutionary auto-voltage sensing blower automatically self adjusts to run on any voltage worldwide. Our inline AD Cyclone has been designed to separate lower particle sizes during laser marking process. Also fits the FireBox inline filter. 980 x 430 x 430mm 38.5 x 17 x 17 380m³/hr / 96mbar 223cfm / 96mbar epiloglaser.co.uk/ad-oracle-iq

fusion 32 The Fusion M2 laser series is the newest addition to Epilog Laser s flatbed system line, and features larger work areas and higher-wattage laser tube options for more throughput and thicker cutting capabilities. Engrave, cut and mark all types of materials with a Fusion M2 laser system that features the highest quality cutting available. ad 1000 iq High performance laser fume extraction system for applications in laser marking, coding and engraving. The AD 1000 iq high end laser extraction system combines extremely large filter capacity with high airflow and pressure rates, making it the ideal choice for heavy duty applications that generate large amounts of particulate and gaseous organic compounds. extractor laser 1197 x 600 x 790mm 47.1 x 23.6 x 31.1 850m³/hr / 100mbar 500cfm / 100mbar epiloglaser.co.uk/ad-1000-iq

extractor laser fusion 40 The Fusion M2 laser series is the newest addition to Epilog Laser s flatbed system line, and features larger work areas and higher-wattage laser tube options for more throughput and thicker cutting capabilities. Engrave, cut and mark all types of materials with a Fusion M2 laser system that features the highest quality cutting available. ad 1500 iq High performance laser fume extraction system for applications in laser marking, coding and engraving. The AD 1000 iq high end laser extraction system combines extremely large filter capacity with high airflow and pressure rates, making it the ideal choice for heavy duty applications that generate large amounts of particulate and gaseous organic compounds. 1197 x 600 x 790mm 47.1 x 23.6 x 31.1 1250m³/hr / 100mbar 735cfm / 100mbar epiloglaser.co.uk/ad-1500-iq

fusion fibre mark Up your production capabilities with a Legend laser series system. Featuring up to 1200 dpi engraving and servo motors for up to 30% more speed, the Legend laser series includes three popular models: the Epilog Mini 18, Mini 24, and Helix laser systems. ad 1000 iq High performance laser fume extraction system for applications in laser marking, coding and engraving. The AD 1000 iq high end laser extraction system combines extremely large filter capacity with high airflow and pressure rates, making it the ideal choice for heavy duty applications that generate large amounts of particulate and gaseous organic compounds. 1197 x 600 x 790mm 47.1 x 23.6 x 31.1 850m³/hr / 100mbar 500cfm / 100mbar extractor laser epiloglaser.co.uk/ad-1000-iq

extractor laser g2 galvo laser The newest addition to the Epilog Laser family is the G2 Galvo fiber laser. With unique dynamic-focus lens technology, it s the first galvo unit with a fixed-position 24 x 24 (609 x 609 mm) engraving area. ad 1000 iq High performance laser fume extraction system for applications in laser marking, coding and engraving. The AD 1000 iq high end laser extraction system combines extremely large filter capacity with high airflow and pressure rates, making it the ideal choice for heavy duty applications that generate large amounts of particulate and gaseous organic compounds. 1197 x 600 x 790mm 47.1 x 23.6 x 31.1 850m³/hr / 100mbar 500cfm / 100mbar epiloglaser.co.uk/ad-1000-iq

product selector BOFA Extraction System Epilog Laser Zing 16 Zing 24 Mini 18 Mini 24 Helix Fusion 32 Fusion 40 Fusion Fiber Mark G2 Galvo laser UML 340 AD Oracle iq AD 500 iq AD 1000 iq AD 1500 iq

warranty certificate WARRANTIES & LIABILITY 7.1 BOFA warrants that at the date the Goods are delivered the Goods will correspond with its sales literature in force at the time being and any other specifications that may have been agreed in writing by BOFA and You, and will be free from defects in materials and workmanship for a period of 12 months from the date of the invoice relating to such Goods provided that the this warranty does not cover normal wear and tear and in addition such warranties shall be null and void if the Goods are modified, improperly installed or used, damaged wilfully, by accident or by neglect or by failure to follow the specified maintenance schedule provided in the user manual or in the event of any parts being improperly installed or replaced (other than by an authorised representative of BOFA). 7.2 All terms, conditions or warranties implied by statutory or common law relating to the Conditions (as defined below) are excluded from this Contract to the fullest extent permitted by law; 7.3 The Conditions shall mean: 7.3.1 the correspondence of the goods with any description; and/or 7.3.2 the quality of the goods; and/or 7.3.3 the fitness of the goods for any purpose(s) whatsoever (whether made known to BOFA or not). 7.4 You acknowledge and agree that where a sample of the Goods have been shown and/or inspected by You, the sole purpose of so doing was to enable You to judge the quality of the bulk; and it does not constitute a sale by sample. 7.5 You shall notify BOFA in writing as soon as reasonably possible after discovery of any defect that would not have been discoverable at the time of delivery or failure of the Goods ( Defect notification ). 7.6 BOFA shall not be under liable, if at the time of Defect notification the title in the Goods in question has not passed to You in accordance with clause 4.1 above. 7.7 If liable, BOFA will, at its option, either make good by repair or the supply of a replacement, defects which, under proper use, appear in the Goods within a reasonable time on receipt of the Goods returned (at Your cost) and claimed to be defective, provided that: 7.7.1 BOFA is satisfied that the defects arise solely from faulty design (other than a design made, furnished or specified You for which BOFA has disclaimed responsibility in writing), materials or workmanship; and 7.7.2 the repaired or replacement Goods will be delivered to You to the original place of delivery, but otherwise subject to the provisions of this Contract. 7.8 As an alternative to Clause 7.7, BOFA shall be, in its absolute discretion, entitled to refund the price of the Goods to You 7.9 The remedies provided in Clause 7.7 and 7.8 are without prejudice to the other provisions of these Terms. 7.10 In no circumstances whatsoever (subject to clause 7.11 below) whether as a result of breach of contract, warranty or tort (including negligence) shall BOFA be liable for any consequential or indirect damages or losses (including but not limited to loss of profit or revenue), damage to associated equipment, cost of capital, cost of such substitute products, loss of facilities or loss for claims of purchases, customs or other such damages. 7.11 Nothing in these Terms shall seek to exclude BOFA s liability for any death or personal injury to the extent that it results from negligence. 7.12 BOFA s liability to You shall be limited: 7.12.1 In relation to any direct physical damage to Your property to the extent that it results from BOFA s actions or omissions up to a maximum of 250,000 in respect of any one event or series of related events, or up to a maximum of 500,000 in respect of any series of unrelated events which take place within a single calendar year; 7.12.2 In relation to any other costs, losses and/or liabilities incurred by You as a consequent of our breach of this Agreement shall be limited to a total sum equivalent to the total price of the Goods and/ or Services. 7.13 Subject to clause 7.11 above, no action regardless of form arising out of a transaction under this Agreement may be brought by You more than two years after the course of action has arisen.

epilog fume extraction solutions epiloglaser.co.uk/products/extractors

ad 500 iq High performance laser fume extraction system for applications in laser marking, coding and engraving. AD 500 iq The AD 500 iq mid to high end laser fume extraction system combines extremely large filter capacity with high airflow and pressure rates, making it the ideal choice for heavy duty applications that generate large amounts of particulate and gaseous organic compounds. Performance has been further enhanced with the inclusion of several features including BOFA s acclaimed patented iq Operating System, making the AD 500 iq one of the most advanced systems available. 1197 x 600 x 790mm 47.1 x 23.6 x 31.1 550m³/hr / 100mbar 324cfm / 100mbar INDEPENDENT FILTER MONITORING bofa.co.uk/ad-500-iq Real time pre filter condition Real time main filter condition Internal unit temperature Run time Target airflow set point Actual airflow in CFM or M 3 /hr

UNIT PART NUMBERS OPTIONS Model Voltage Part No. 24V Stop / Start AD 500 iq 230V L0672 Stainless Steel 115V L0671 AD 500 iq 230V L0662 Powder Coated 115V L0661 Filter change / System failure signal VOC Monitoring On-board Compressor A2001 A2002 A2003 A2007 OPTION Larger exhaust silencing boxes A1060094 REPLACEMENT FILTER PART NUMBERS Model DeepPleat DUO Pre Filter Combined HEPA/Gas Filter AD 500 iq A1030222 A1030297 TECHNICAL DATA EU US (HxWxD) 1197 x 600 x 790mm 47.1 x 23.6 x 31.1 Cabinet Construction Brushed stainless steel / Powder coated mild steel Airflow / Pressure 550m³/hr / 100mbar 324cfm / 100mbar Electrical Data Noise Level 230v 1ph 50/60Hz Full load current: 9.5 amps / 1.1kw < 60dBA At typical operating speed. Weight 135kgs 298lbs Approvals CE 115v 60/50Hz Full load current: 14.8 amps / 1.1kw DEEPPLEAT DUO PRE FILTER SPECIFICATIONS Surface Media Area Filter Media Filter Media Construction Filter Housing Filter Efficiency 30m² approx Glass Fibre Maxi Pleat Construction with Webbing Spacers Zintec mild steel F8 (95% @ 0.9 microns) COMBINED HEPA/GAS FILTER SPECIFICATIONS Surface Media Area HEPA Filter Media HEPA Media Construction Filter Housing Treated Activated Carbon Filter Efficiency 7.5m² approx Glass Fibre Maxi Pleat Construction with Webbing Spacers Zintec Mild Steel 34kgs 99.997% @ 0.3 microns AIRFLOW THROUGH FILTERS Chemical Filter HEPA Filter Pre Filter Clean Air Contaminated Air Particulate Fumes are held in the chemical gas filter Small particulate is held in the HEPA filter Medium sized particulate held in the filter media Velocity drops through expansion Large particulate settles to the bottom of the Deep- Pleat DUO filter box

ad 1000 iq High performance laser fume extraction system for applications in laser marking, coding and engraving. AD 1000 iq High performance laser fume extraction system for applications in laser marking, coding and engraving. BOFA s AD 1000 iq high end laser extraction system combines extremely large filter capacity with high airflow and pressure rates, making it the ideal choice for heavy duty applications that generate large amounts of particulate and gaseous organic compounds. 1197 x 600 x 790mm 47.1 x 23.6 x 31.1 850m³/hr / 100mbar 500cfm / 100mbar bofa.co.uk/ad-1000-iq INDEPENDENT FILTER MONITORING Real time pre filter condition Real time main filter condition Internal unit temperature Run time Target airflow set point Actual airflow in CFM or M 3 /hr

UNIT PART NUMBERS OPTIONS Model Voltage Part No. 24V Stop / Start AD 1000 iq 230V L0772 Stainless Steel 115V L0771 AD 1000 iq 230V L0762 Powder Coated 115V L0761 Filter change / System failure signal VOC Monitoring On-board Compressor A2001 A2002 A2003 A2007 OPTION Larger exhaust silencing boxes A1060094 REPLACEMENT FILTER PART NUMBERS Model DeepPleat DUO Pre Filter Combined HEPA/Gas Filter AD 1000 iq A1030222 A1030297 TECHNICAL DATA EU (HxWxD) 1197 x 600 x 790mm 47.1 x 23.6 x 31.1 Cabinet Construction US Brushed stainless steel / Powder coated mild steel Airflow / Pressure 850m³/hr / 100mbar 500cfm / 100mbar Electrical Data 230v 1ph 50/60Hz Full load current: 12.8 amps / 2.2kw 115v 60/50Hz Full load current: 19.5 amps / 2.2kw Noise Level < 63dBA (at typical operating speed) < 58dBA - with rear silencing boxes fitted Weight 140kgs 309lbs Approvals CE DEEPPLEAT DUO PRE FILTER SPECIFICATIONS Surface Media Area Filter Media Filter Media Construction Filter Housing Filter Efficiency 30m² approx Glass Fibre Maxi Pleat Construction with Webbing Spacers Zintec mild steel F8 (95% @ 0.9 microns) COMBINED HEPA/GAS FILTER SPECIFICATIONS Surface Media Area HEPA Filter Media HEPA Media Construction Filter Housing Treated Activated Carbon Filter Efficiency 7.5m² approx Glass Fibre Maxi Pleat Construction with Webbing Spacers Zintec Mild Steel 34kgs 99.997% @ 0.3 microns AIRFLOW THROUGH FILTERS Chemical Filter HEPA Filter Pre Filter Clean Air Contaminated Air Particulate Fumes are held in the chemical gas filter Small particulate is held in the HEPA filter Medium sized particulate held in the filter media Velocity drops through expansion Large particulate settles to the bottom of the Deep- Pleat DUO filter box

ad 1500 iq High performance laser fume extraction system for applications in laser marking, coding and engraving. AD 1500 iq The AD 1500 iq high end laser extraction system combines extremely large filter capacity with high airflow and pressure rates, making it the ideal choice for heavy duty applications that generate large amounts of particulate and gaseous organic compounds. Performance has been further enhanced with the inclusion of several features including BOFA s acclaimed patented iq system, making the AD 1500 iq one of the most advanced systems available. 1197 x 600 x 790mm 47.1 x 23.6 x 31.1 1250m³/hr / 100mbar 735cfm / 100mbar INDEPENDENT FILTER MONITORING bofa.co.uk/ad-1500-iq Real time pre filter condition Real time main filter condition Internal unit temperature Run time Target airflow set point Actual airflow in CFM or M 3 /hr

UNIT PART NUMBERS OPTIONS Model Voltage Part No. 24V Stop / Start AD 1500 iq 230V L0862 Powder Coated 3Ph L0863 Filter change / System failure signal VOC Monitoring On-board Compressor A2001 A2002 A2003 A2007 OPTION Larger exhaust silencing boxes A1060094 REPLACEMENT FILTER PART NUMBERS Model DeepPleat DUO Pre Filter Combined HEPA/Gas Filter AD 1500 iq A1030222 A1030297 TECHNICAL DATA (HxWxD) Cabinet Construction Airflow / Pressure Electrical Data Noise Level Weight Approvals EU 1197 x 600 x 790mm Powder coated mild steel 1350m³/hr (795cfm) / 100mbar 230v 1ph 50/60Hz Full load current: 24 amps / 3.3kw 3Ph 7 amps per phase / 12 amps nautral < 63dBA At typical operating speed. 145kgs (320lbs) CE DEEPPLEAT DUO PRE FILTER SPECIFICATIONS Surface Media Area Filter Media Filter Media Construction Filter Housing Filter Efficiency 30m² approx Glass Fibre Maxi Pleat Construction with Webbing Spacers Zintec mild steel F8 (95% @ 0.9 microns) COMBINED HEPA/GAS FILTER SPECIFICATIONS Surface Media Area HEPA Filter Media HEPA Media Construction Filter Housing Treated Activated Carbon Filter Efficiency 7.5m² approx Glass Fibre Maxi Pleat Construction with Webbing Spacers Zintec Mild Steel 34kgs 99.997% @ 0.3 microns AIRFLOW THROUGH FILTERS Chemical Filter HEPA Filter Pre Filter Clean Air Contaminated Air Particulate Fumes are held in the chemical gas filter Small particulate is held in the HEPA filter Medium sized particulate held in the filter media Velocity drops through expansion Large particulate settles to the bottom of the Deep- Pleat DUO filter box

ad oracle iq The premier choice and best in class solution for fume extraction in laser marking, coding and engraving applications. AD Oracle iq The AD Oracle iq is our most technically advanced laser fume extractor, combining a powerful range of unique features into one compact unit. This versatile unit can be used across a range of laser applications and the revolutionary auto-voltage sensing blower automatically self adjusts to run on any voltage worldwide. 980 x 430 x 430mm 38.5 x 17 x 17 380m³/hr / 96mbar 223cfm / 96mbar bofa.co.uk/ad-oracle-iq INDEPENDENT FILTER MONITORING Real time pre filter condition Real time main filter condition Internal unit temperature Run time Target airflow set point Actual airflow in CFM or M 3 /hr

UNIT PART NUMBERS OPTIONS Model Voltage Part No. 24V Stop / Start Filter change / VOC Monitoring System failure signal UML 340 Powder Coated 90-257v V1543-8200 A2001 A2002 A2003 REPLACEMENT FILTER PART NUMBERS Model DeepPleat DUO Pre Filter Combined HEPA/Gas Filter UML 340 A1030156 A1030155 TECHNICAL DATA EU US (HxWxD) 715 x 760 x 600mm 28.1 x 29.9 x 23.6 Cabinet Construction Powder coated mild steel Airflow / Pressure 380m³/hr / 96mbar 223cfm / 96mbar Electrical Data 90-257v 1ph 50/60Hz Full load current: 12.5 amps / 1.1kw Noise Level < 56 dba (at typical operating speed) Weight 82kg 143lbs Approvals CE DEEPPLEAT DUO PRE FILTER SPECIFICATIONS Surface Media Area Filter Media Filter Media Construction Filter Housing Filter Efficiency 30m² approx Glass Fibre Maxi Pleat Construction with Webbing Spacers Zintec mild steel F8 (95% @ 0.9 microns) COMBINED HEPA/GAS FILTER SPECIFICATIONS Surface Media Area HEPA Filter Media HEPA Media Construction Filter Housing Treated Activated Carbon Filter Efficiency 7.5m² approx Glass Fibre Maxi Pleat Construction with Webbing Spacers Zintec Mild Steel 34kgs 99.997% @ 0.3 microns AIRFLOW THROUGH FILTERS Chemical Filter HEPA Filter Pre Filter Clean Air Contaminated Air Particulate Fumes are held in the chemical gas filter Small particulate is held in the HEPA filter Medium sized particulate held in the filter media Velocity drops through expansion Large particulate settles to the bottom of the DeepPleat DUO filter box

uml 340 Base system designed laser engraving applications where a laser engraver can sit on top of the extractor,effectively doubling it up as a work station. UML 340 The UML 340 plays on the success of the best in class AD Oracle with its DeepPleat DUO and auto-voltage blower in a compact base system. BOFA s easi-seal filter location makes filter change easy, quick and safe. 715 x 760 x 600mm 28.1 x 29.9 x 23.6 380m³/hr / 96mbar 223cfm / 96mbar bofa.co.uk/uml-340

UNIT PART NUMBERS OPTIONS Model Voltage Part No. 24V Stop / Start UML 340 Powder Coated Filter change / System failure signal VOC Monitoring 90-257v L1543-8200 A2001 A2002 A2003 REPLACEMENT FILTER PART NUMBERS Model DeepPleat DUO Pre Filter Combined HEPA/Gas Filter UML 340 A1030156 A1030155 TECHNICAL DATA EU US (HxWxD) 715 x 760 x 600mm 28.1 x 29.9 x 23.6 Cabinet Construction Powder coated mild steel Airflow / Pressure 380m³/hr / 96mbar 223cfm / 96mbar Electrical Data 90-257v 1ph 50/60Hz Full load current: 12.5 amps / 1.1kw Noise Level < 56 dba (at typical operating speed) Weight 82kg 143lbs Approvals CE DEEPPLEAT DUO PRE FILTER SPECIFICATIONS Surface Media Area Filter Media Filter Media Construction Filter Housing 12m² approx Glass Fibre Maxi Pleat with webbing spacer Zintec mild steel COMBINED FILTER SPECIFICATIONS HEPA Filter Media HEPA Media Construction Glass Fibre Maxi Pleat Construction with Webbing Spacers Filter Efficiency 99.997% @ 0.3 microns Filter Efficiency F8 (95% @ 0.9 microns) Treated Activated Carbon 15kgs Filter Housing Zintec Mild Steel AIRFLOW THROUGH FILTERS Chemical Filter HEPA Filter Pre Filter Clean Air Contaminated Air Fumes are held in the chemical gas filter Small particulate is held in the HEPA filter Medium sized particulate held in the filter media Velocity drops through expansion Particulate Large particulate settles to the bottom of the Deep- Pleat DUO filter box