MOD6 RCBOs New and retrofit solutions providing reliable personnel protection POWER DISTRIBUTION AND PROTECTION NHP Electrical Engineering Products Pty Ltd AUS NZ 1300 NHP NHP 0800 NHP NHP nhp.com.au nhp-nz.com
Compact 1 Pole RCBS Features Ideal for both loadcentres and panelboards Genuine 6kA short circuit protection 6-32A overload protection 30mA earth leakage protection (10mA option) Switched neutral version Same size as a standard MCB Easy to retrofit an MCB with RCBO Load screw terminals Line active screw terminals Line neutral flying lead Utilises standard pin buscomb (links direct MCB and main switch) Dual DIN clip (top and bottom) M6 RCBS Module Width Unswitched Neutral Switched Neutral RCBO 6kA 1P 06A 30mA MOD6 1 M6 RCBS 0630C M6 RCBS 0630CAN RCBO 6kA 1P 10A 30mA MOD6 1 M6 RCBS 1030C M6 RCBS 1030CAN RCBO 6kA 1P 16A 30mA MOD6 1 M6 RCBS 1630C M6 RCBS 1630CAN RCBO 6kA 1P 20A 30mA MOD6 1 M6 RCBS 2030C M6 RCBS 2030CAN RCBO 6kA 1P 25A 30mA MOD6 1 M6 RCBS 2530C M6 RCBS 2530CAN RCBO 6kA 1P 32A 30mA MOD6 1 M6 RCBS 3230C M6 RCBS 3230CAN Accessories Special buscomb for quick installation 12 way single phase pin busbar comb 1BC112P 15 way single phase pin busbar comb 1BC115P 18 way single phase pin busbar comb 1BC118P Lock dog DTLD Dimensions (mm) M6PB36M160 2
Compact 1 Pole RCBD Features Suits loadcentres Easy to retrofit an MCB with RCBO Genuine 6kA short circuit protection Line/ load - screw terminals 6-32A Overload protection No flying leads 1 ) 30mA Earth leakage protection (10mA option) Special buscomb to allow quick installation Switched neutral version Dual DIN clip (top and bottom) Same size as a standard MCB M6 RCBD Module Width Unswitched Neutral Switched Neutral RCBO 6kA 1P 06A 30mA MOD6 1 M6 RCBD 0630C M6 RCBD 0630CAN RCBO 6kA 1P 10A 30mA MOD6 1 M6 RCBD 1030C M6 RCBD 1030CAN RCBO 6kA 1P 16A 30mA MOD6 1 M6 RCBD 1630C M6 RCBD 1630CAN RCBO 6kA 1P 20A 30mA MOD6 1 M6 RCBD 2030C M6 RCBD 2030CAN RCBO 6kA 1P 25A 30mA MOD6 1 M6 RCBD 2530C M6 RCBD 2530CAN RCBO 6kA 1P 32A 30mA MOD6 1 M6 RCBD 3230C M6 RCBD 3230CAN Accessories 13 pole 2P buscomb (active, neutral) IBD213P 18 pole 2P buscomb (active, neutral) 2 ) IBD218P 55 pole 2P buscomb (active, neutral) 2 ) IBD255P Encap suit IBD218P IBDEC2 Pin terminal 25mm DTTLT25PN2 Lock dog DTLD Dimensions (mm) Special buscomb for quick installation 1 ) Switched neutral version 2 ) Can be cut to size 3
1 Pole RCBO Features Suits panelboard busbar chassis Genuine 6kA short circuit protection 10-32A Overload protection 30mA Earth leakage protection Type A 1P 18mm width Load - screw terminals Line - active large screw terminal, neutral flying lead Utilises standard buscomb and chassis DIN clip bottom MOD6 RCBO 1 Module Width RCBO 6 ka 1 P 10 A 30 ma MOD6 1 MOD6 RCBO 1 1030AL RCBO 6 ka 1 P 16 A 30 ma MOD6 1 MOD6 RCBO 1 1630AL RCBO 6 ka 1 P 20 A 30 ma MOD6 1 MOD6 RCBO 1 2030AL RCBO 6 ka 1 P 25 A 30 ma MOD6 1 MOD6 RCBO 1 2530AL RCBO 6 ka 1 P 32 A 30 ma MOD6 1 MOD6 RCBO 1 3230AL Accessories 12 way single phase pin busbar comb 1BC112P 15 way single phase pin busbar comb 1BC115P 18 way single phase pin busbar comb 1BC118P Lock dog DTLD M6PB36M160 Dimensions (mm) 4
2 Pole RCBO Features Suits both loadcentres and Panelboards Genuine 6kA short circuit protection 6-40A Overload protection 30mA Earth leakage protection (10mA option) Switched neutral 2P 36mm width Load - large screw terminals Line - large screw terminals 1P+N buscomb or 4P chassis DIN clip bottom MOD6 RCBO 2 Module Width RCBO 6 ka 2 P 10 A 30 ma MOD6 2 MOD6 RCBO 2 1030 RCBO 6 ka 2 P 16 A 30 ma MOD6 2 MOD6 RCBO 2 1630 RCBO 6 ka 2 P 20 A 30 ma MOD6 2 MOD6 RCBO 2 2030 RCBO 6 ka 2 P 25 A 30 ma MOD6 2 MOD6 RCBO 2 2530 RCBO 6 ka 2 P 32 A 30 ma MOD6 2 MOD6 RCBO 2 3230 Accessories 6 way 1P+N pin busbar comb 1CL62 10 way 1P+N pin busbar comb 1CL102 Axil spade terminal 25mm DTTAX25SP Axil pin terminal 25mm DTTAX25PN Axil pin terminal 50mm DTTAX50PN Lock dog DTLD Dimensions (mm) 5
Specification 1P Compact Unswitched Neutral M6RCBS 1P compact Switched Neutral Approval no. NSW 24576 NSW 24576 Standards AS/NZS 61009 AS/NZS 61009 Magnetic tripping characteristics C C Residual tripping characteristics AC A Rated current 6-32A 6-32A Rated residual current 30mA 30mA, 10mA Calibration temperature 30 C 30 C Rated voltage 240V 240V Frequency 50 / 60 50 / 60 Maximum service voltage 255 265 Minimum service voltage 85 85 Minimum voltage for leakage protection 85 85 Power supply Bottom Bottom Selectivity class 3 3 Residual making and breaking capacity 3kA 4.5kA Short circuit capacity 6kA 6kA Isolation application (IEC 60947-2) Yes Yes Insulation resistance (Mohm) 1,000 1,000 Insulation voltage (V) 500 440 Dielectric rigidity (V) 2,500 2,500 Vibration resistance 1.5g 1.5g Endurance (operations) Electrical/Mechanical 10,000/20,000 10,000/20,000 Protection degree (outside/inside enclosure) IP20/IP40 IP20/IP40 Self extinguishing degree (UL 94) V 2 V 2 Tropicalisation (IEC 60068-2) +55 C / 95% RH +55 C / 95% RH Operating temperature -5 / +55 C -5 / +60 C Storage temperature -25 / +70 C -25 / +70 C Terminal capacity (top) min/max 1/25mm 1/25 Terminal capacity (bottom) min/max 1/25 1/25 Terminal torque (top / bottom) (Nm) 3 3 Busbar systems (bottom) Yes (std Pin) Yes (std Pin) Dimensions (mm) 76 (H) 86 (L) 18 (W) 76 (H) 86 (L) 18 (W) Weight (g) 215 215 6
1P Compact Unswitched Neutral M6RCBD MOD6RCBO1 MOD6RCBO2 1P compact Switched Neutral 1P Long body RCBO 2P RCBO NSW 24576 NSW 24576 N17482 N17482 AS/NZS 61009 AS/NZS 61009 AS/NZS 61009 AS/NZS 61009 C C C C AC A A A, AC 6-32A 6-32A 10-32A 6-40A 30mA 30mA, 10mA 30mA 30mA, 10mA 30 C 30 C 30 C 30 C 240V 240V 240V 240V 50 / 60 50 / 60 50 / 60 50 / 60 255 265 255 255 85 85 195 117 85 85 100 Voltage independent Bottom Bottom Bottom Top/Bottom 3 3 3 3 3kA 4.5kA 6kA 6kA 6kA 6kA 6kA 6kA Yes Yes Yes Yes 1,000 1,000 1,000 1,000 500 400 500 500 2,500 2,500 2,500 2,500 1.5g 1.5g 2.0g 1.5g 10,000/20,000 10,000/20,000 10,000/20,000 10,000/20,000 IP20/IP40 IP20/IP40 IP20/IP40 IP20/IP40 V 2 V 2 V 2 V 2 +55 C / 95% RH +55 C / 95% RH +55 C / 95% RH +55 C / 95% RH -5 / +55 C -5 / +60 C -5 / +60 C -25 / +60 C -25 / +70 C -25 / +70 C -25 / +70 C -25 / +70 C 1/25 1/25 1/25 1/25 1/25 1/25 1/35 1/35 3 3 3/4.5 3/4 Yes (spec pin) Yes (spec pin) Yes (std pin or fork) Yes (std pin or fork) 76 (H) 86 (L) 18 (W) 76 (H) 86 (L) 18 (W) 76 (H) 125 (L) 18 (W) 76 (H) 86 (L) 36 (W) 125 125 350 250 General application requirements 1 ) Australia New Zealand Residential - General light and power Non-switched Neutral Switched Neutral Commercial - General light and power Non-switched Neutral Non-switched Neutral Industrial - General light and power Non-switched Neutral Non-switched Neutral Schools, Kindergartens Non-switched Neutral Switched Neutral Medical (GP, centres, hospitals etc.) Switched Neutral Switched Neutral Caravans / RV (mobile homes) Switched Neutral Switched Neutral Service stations Switched Neutral Switched Neutral Construction sites Switched Neutral Switched Neutral High risk applications Switched Neutral Switched Neutral 1 ) Always refer to your local standards/regulation specific requirements which may differ from these recommendations 7
For more information, scan to download the NHP ecatalogues App offering exclusive video content, catalogues and literature! AUSTRALIA nhp.com.au SALES 1300 NHP NHP sales@nhp.com.au VICTORIA Melbourne 43-67 River Street Richmond VIC 3121 Tel +61 3 9429 2999 Laverton 104-106 William Angliss Drive Laverton North VIC 3026 Tel +61 3 9368 2901 Dandenong Unit 1/80 Monash Drive Dandenong South VIC 3175 Tel +61 3 8773 6400 Fax 1300 647 329 TASMANIA Hobart 29B Lampton Ave Derwent Park TAS 7009 Tel +61 3 6228 9575 Fax +61 3 6228 9757 Launceston Unit 3 13-17 Merino Street Kings Meadows TAS 7249 Tel +61 3 6345 2600 Fax +61 3 6344 6324 SOUTH AUSTRALIA Adelaide 36-38 Croydon Road Keswick SA 5035 Tel +61 8 8297 9055 NEW SOUTH WALES Sydney 30-34 Day Street North Silverwater NSW 2128 Tel +61 2 9748 3444 Newcastle 575 Maitland Road Mayfield West NSW 2304 Tel +61 2 4960 2220 Fax +61 2 4960 2203 Wollongong Unit 3 1 Resolution Drive Unanderra NSW 2526 Tel 1300 647 647 Fax 1300 647 329 Albury / Wodonga 847 Ramsden Drive Albury NSW 2640 Tel +61 2 6049 0600 Fax +61 3 6025 0592 ACT Canberra Unit 1 187 Gladstone Street Fyshwick ACT 2609 Tel +61 2 6280 9888 Fax +61 2 6280 9588 WESTERN AUSTRALIA Perth 38 Belmont Ave Rivervale WA 6103 Tel +61 8 9277 1777 NORTHERN TERRITORY Darwin 3 Steele Street Winnellie NT 0820 Tel +61 8 8947 2666 Fax +61 8 8947 2049 QUEENSLAND Brisbane 16 Riverview Place Murarrie QLD 4172 Tel +61 7 3909 4999 Townsville 5 Leyland Street Garbutt QLD 4814 Tel +61 7 4779 0700 Fax +61 7 4775 1457 Rockhampton 1 Lawson Street Parkhurst QLD 4702 Tel +61 7 4927 2277 Fax +61 7 4922 2947 Toowoomba Cnr Carroll Street and Struan Court QLD 4350 Tel +61 7 4634 4799 Fax +61 7 4633 1796 Cairns Unit 2 1 Bramp Close Portsmith QLD 4870 Tel +61 7 4035 6888 Fax +61 7 4035 6999 NEW ZEALAND nhp-nz.com SALES 0800 NHP NHP sales@nhp-nz.com PO Box 62-009 Sylvia Park Auckland 1644 New Zealand Auckland 118a Carbine Road Mt Wellington 1060 Hamilton 78 Rostrevor Street Hamilton 3204 Palmerston North C/O The Factory, 21 Dairy Farm Road, Palmerston North, 4472 Wellington Unit B4, 59 Marsden Street Melling Lower Hutt 5010 Christchurch 27 Iversen Terrace Waltham 8011 Dunedin 30 Fox Street South Dunedin 9012 NHP Electrical Engineering Products Pty Ltd A.B.N. 84 004 304 812 NHPMOD6RCBORANGEC 05/16 Copyright NHP 2016