Model H100 - H400 EXPLODED VIEW TECHNICAL DATA SHEET ALUMUNIUM DOME. GLASS REINFORCED NYLON 6 BEARING HOLDER & HOLDER ARMS (MODEL H300 & H400 only)

Similar documents
Model S S2 400

Trade Brochure & Price List 2015/16

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

NEW GENERATION SERIES

650mA Phase Dimmable LED Driver

1000mA - 650mA Phase Dimmable LED Driver

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.


SKYLIGHTS VENTILATION VELUX ROOF WINDOWS LOFT LADDERS ROOF HATCHES. invite nature inside!

(click on page links below) XAL-2C Technical Data 1. XAL-4C Technical Data 3

JD3 rated for greater connection strength. makes it easy to spot in the warehouse or on site

Louvre systems. Series WLD Weather louvre doors. Incorporating. Fully active louvre panel integrated into a door

Conergy PH 185M 200M. Special Edition Australia. Specifications Photovoltaic modules

DALI 650mA LED Driver

Compact Design BB101 & 93

A B C D E F 113' - 2" 22' - 6" 22' - 6" 22' - 6" 22' - 6" 23' - 2" A A A3.11 A3.

WALL VENTILATION GRILLES CBP

Ventilation grilles for installation into walls, sills or rectangular

Strutting Beams Supporting Underpurlins Only

Ceiling swirl diffusers with perforated face plate

Novenco axial flow fans. ZerAx - Standard January 2010

FULLY CERTIFIED ON-TIME DELIVERY ATEC GRP ENCLOSURES

Louvred Grilles can be used internally and externally are available with or without a flyscreen and provide excellent airflow performance.

Handrail Handrail I ; (/'' -*, 0+. '/'' )/, /*. nnn%cfzb\i%zfd%xl nnn%cfzb\ieq%zf%eq

Air Handling Piping Systems

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Product Availability Guide. Pipe and tube structural products

Outside Louvers. Series OHCL, OHL, OHL-CD, OHL-D, OHL-KD, OHL-LAOGS, OHL-LOUVER DOOR, OHL-ST2/ST4, OVL & PHL

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

ALD. Sound attenuating exterior wall grille QUICK FACTS. Excellent noise attenuation A robust grille that withstands severe climatic conditions

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Product Nomenclature G-X-AB-Z 0 = Zero Degree, 1 = 15 Degree, 2 = 15 Degree (2-way)

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Fans & extraction cooker hoods must have the correct size ducting. Please refer to the manufacturers recommended specification.

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

DSA HIGH EFFICIENCY DROPLET SEPARATOR DROPLET SEPARATOR DSA. With heated vanes

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide.

INDEX. Chapter3. air master. Linear Bar Grilles

9120 EBCU Battery Charger MODELS: 9120EBCU96V 9120EBCU240V

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

Incorporating V2.1. Product spec >>> > Series WL - Standard weather louvres

Splash-proof Terminal HEPA Filter

Stainless Steel Chimneys Ducts and Fittings for Air Conditioning & Ventilation

AB INDUSTRIES. Flues and Fittings

PATIO AWNINGS HAROL VZ520 TECHNICAL INFORMATION

EYELASH DIFFUSERS E SERIES. Quality and efficiency without compromise

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

Water Supply and Sewerage Approved Products Manual - February 2006

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

Light + Air Republic of Ireland & UK. Eura Ventilator Data Sheet

McKenzie Martin Louvres & Ventilation Systems Louvres Maximair Louvre Systems Turret Louvres

Roof Hatches Smoke Vents /BAB BuyLine 0898

AB INDUSTRIES WOOD FIRE. Flues and Fittings

WGA Long throw nozzle grille

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Light + Air UK & Republic of Ireland. Multilateral Louvred Ventilator Data Sheet

Ceiling swirl diffusers

Dual wall sub-base diesel fuel tanks -

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

Type VSD35. Nominal length up to 1500 mm: one spigot

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Easy to Work With. Repair or replacement applications. Covers load tested to Australian Standards

Saxton. Steel Sectional Doors

DALI Emergency LED Driver - 350/700/1000mA Constant Current

HIGH-POWERED VENTILATORS

Installation Guide. Installation Requirements for Rainwater Tanks

ABN Quality Endorsed Company ISO9001 Lic No EDITION 2

Tank Installation Instructions

PRODUCT GUIDE AS/NZS ISO 9001:2000 A DIVISION OF ALLIANCE CASTING & ENGINEERING SOLUTIONS PTY LTD

SENSOR COMPETENCE AN OVERVIEW

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Ceiling and Inline Fans

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular

TJMMIT002

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

SECTION HVAC POWER VENTILATORS

Centrifugal Upblast Power Roof Ventilators

Ventilation grilles for installation into walls, sills or rectangular

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

Mounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217

Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts

DS Series Solar System

Automatic Roof Door Vents

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables

Free-Form Optics. Heavy Duty Bulb. Heavy Duty Mounts

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

FILTERED SUPPLY CENTRIFUGAL Belt Drive

250 Watt. Features. Positive tolerance Positive tolerance of up to 5% delivers higher outputs reliablity

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Technical standard for AC, DC and street light systems

Transcription:

. ISO 9001 EXPLODED VIEW H100 - H400 ALUMUNIUM DOME GLASS REINFORCED NYLON 6 BEARING HOLDER & HOLDER ARMS (MODEL H300 & H400 only) BEARING ALUMINIUM TURBINE/IMPELLER ALUMINIUM SHAFT ALUMINIUM THROAT & BRACKETS ALUMINIUM VARIPITCH ALUMINIUM FLASHING 6

. ISO 9001 H100 - H400 PRODUCT DIMENSION & WEIGHT H100 - H400 Turbine, Varipitch and Flashing 1 A (OD) E D B (ID) C A : Overall turbine diameter B : Internal diameter of flashing opening C: Flashing Overall D : Clearance flashing to turbine E : Overall Height In Metric Units In Imperal Units Dimensions*(mm) Dimensions # (inches) Roof Slope Range Roof Slop Range A B C D E kg A B C D E lb H100 290 98.6 430 x 430 139 313 1.80 0-45 H100 11.4 3.88 16.9 x 16.9 5.5 12.3 3.97 0-45 H150 332 145.6 430 x 430 164 363 2.40 0-45 H150 13.1 5.73 16.9 x 16.9 6.5 14.3 5.29 0-45 H300 477 298 600 x 500 225 480 4.90 0-45 H300 18.8 11.73 23.6 x 19.7 8.9 18.9 10.80 0-45 H400 561 401 750 x 700 274 564 6.30 0-45 H400 22.1 15.78 29.5 x 27.6 10.8 22.2 13.89 0-45 * Tolerance is within +/- 5mm and +/- 0.5kgs # Tolerance is within +/- 0.2 inches and +/- 1.1lbs 1 The Hurricane throat overlaps the Varipitch. The height listed above is with the maximum overlap (lowest overall height). Revolving the Varipitch to suit a roof slope also reduces the complete ventilator s overall height. 7

. ISO 9001 PRODUCT DIMENSION & WEIGHT H100 - H400 Turbine A (OD) G F (ID) A : Overall turbine diameter F : Effective inner throat opening area G: Overall turbine only height In Metric Units In Imperal Units Dimensions* (mm) Dimensions # (inches) A F G kg A F G lb H100 290 107 253 1.30 H100 11.4 4.2 10.0 2.87 H150 332 155 283 1.90 H150 13.1 6.1 11.1 4.19 H300 477 308 364 3.70 H300 18.8 12.1 14.3 8.16 H400 561 410 389 4.50 H400 22.1 16.1 15.3 9.92 * Tolerance is within +/- 5mm and +/- 0.5kgs # Tolerance is within +/- 0.2 inches and +/- 1.1lbs 8

H100 - H400 PRODUCT CLASSIFICATION AND PERFORMANCE H100 - H400 PRODUCT INFORMATION SUMMARY Ventilator Range Hurricane Ventilator H100 H150 H300 H400 Ventilator Type (AS/NZS 4740:2000 cl 1.5) Type 4 - Rotating wind-driven roof ventilator Ventilator Performance Class (AS/NZS 4740:2000 Table 1.2) Rain Resistance 50 m/s No Water - Class A 50 m/s No Water - Class A 50 m/s No Water - Class A 50 m/s No Water - Class A Effective Aerodynamic Area, EAA 0.004 m 2 0.011 m 2 0.044 m 2 0.078 m 2 Effective Aerodynamic Area, C d 0.6 - Class 2 0.67 - Class 2 0.71 - Class 1 0.7 - Class 1 Flow Coefficient, C f 0.26 - Class 4 0.28 - Class 4 0.31 - Class 3 0.24 - Class 4 Wind Loading 57m/s - Level 1 57m/s - Level 1 57m/s - Level 1 57m/s - Level 1 Nominal Performance* (m 3 /hr) 0 m/s 31 m 3 /hr 97 m 3 /hr 376 m 3 /hr 669 m 3 /hr 3 m/s 32 m 3 /hr 103 m 3 /hr 404 m 3 /hr 699 m 3 /hr 6 m/s 37 m 3 /hr 119 m 3 /hr 478 m 3 /hr 783 m 3 /hr *In accordance to AS/NZS 4740:2000 nominal performance parameters, as per cl3.5 at h = 6m, T = 14oC, T = 20o PERFORMANCE Natural wind ventilators must be manufactured in Australia and in an ISO 9001 certified factory. They must: Be tested in accordance to the Australian and New Zealand standard AS/NZS 4740:2000 Performance of Natural Ventilation. Have the tested capability of withstanding wind speed of 205.2km/hr. FINISHES Available in a mill or a range of powder coat colours upon request ACCESSORIES When specified, accessories such as manual damper, electric damper, EC damper grilles, and special bases (spigot, square to round and EX Base) are available upon request. WARRANTIES CSR Building Products Limited ABN 55 008 631 356 T/A Edmonds ( Edmonds ) warrants from the date of install, for a period of FIFTEEN (15) YEARS that the Edmonds Hurricane Natural Ventilator turbine and body will retain its performance characteristics and be free from faulty materials and workmanship on the condition that the vent is installed in accordance to the installation instructions. Please refer to Warranty Document on edmonds.com.au for full details. 9

. ISO 9001 EXPLODED VIEW H450 - H600 ALUMUNIUM DOME GLASS REINFORCED NYLON 6 BEARING HOLDER & HOLDER ARMS BEARING ALUMINIUM TURBINE/IMPELLER ALUMINIUM SHAFT ALUMINIUM THROAT & BRACKETS ALUMINIUM VARIPITCH ALUMINIUM FLASHING 10

. ISO 9001 PRODUCT DIMENSION & WEIGHT H450 - H600 Turbine, Varipitch and Flashing 1 H450 - H600 A (OD) E D B (ID) C A : Overall turbine diameter B : Internal diameter of flashing opening C: Flashing Overall D : Clearance flashing to turbine E : Overall Height In Metric Units In Imperal Units Dimensions*(mm) Dimensions # (inches) Roof Slope Range Roof Slop Range A B C D E kg A B C D E lb H450 648 452 750 x 700 319 634 8.10 0-45 H450 25.5 17.80 29.5 x 27.7 12.6 25.0 17.86 0-45 H500 702 502 750 x 700 345 700 9.20 0-45 H500 27.6 19.77 29.5 x 27.8 13.6 27.6 20.28 0-45 H600 766 592 1000 x 1000 359 724 11.80 0-45 H600 30.2 23.30 39.4 x 39.4 14.1 28.5 26.01 0-45 * Tolerance is within +/- 5mm and +/- 0.5kgs # Tolerance is within +/- 0.2 inches and +/- 1.1lbs 1 The Hurricane throat overlaps the Varipitch. The height listed above is with the maximum overlap (lowest overall height). Revolving the Varipitch to suit a roof slope also reduces the complete ventilator s overall height. 11

. ISO 9001 PRODUCT DIMENSION & WEIGHT H450 - H600 Turbine A (OD) G F (ID) F A : Overall turbine diameter F : Effective inner throat opening area G: Overall turbine only height In Metric Units In Imperal Units Dimensions* (mm) Dimensions # (inches) A F G kg A F G lb H450 648 462 443 6.20 H450 25.5 18.2 17.4 13.67 H500 702 511 459 6.90 H500 27.6 20.1 18.1 15.21 H600 766 602 484 8.10 H600 30.2 23.7 19.1 17.86 * Tolerance is within +/- 5mm and +/- 0.5kgs # Tolerance is within +/- 0.2 inches and +/- 1.1lbs 12

PRODUCT CLASSIFICATION AND PERFORMANCE H450 - H600 H450 - H600 PRODUCT INFORMATION SUMMARY Ventilator Range Hurricane Ventilator H450 H500 H600 Ventilator Type Type 4 - Rotating wind-driven roof ventilator Ventilator Performance Class (AS/NZS 4740:2000 Table 1.2) Rain Resistance 50 m/s No Water - Class A 50 m/s No Water - Class A 50 m/s No Water - Class A Effective Aerodynamic Area, EAA 0.109 m 2 0.128 m 2 0.139 m 2 Effective Aerodynamic Area, C d 0.77 - Class 1 0.73 - Class 1 0.54 - Class 2 Flow Coefficient, C f 0.22 - Class 4 0.22 - Class 4 0.18 - Class 4 Wind Loading 57m/s - Level 1 57m/s - Level 1 57m/s - Level 1 Nominal Performance* (m 3 /hr) 0 m/s 933 m 3 /hr 1090 m 3 /hr 1189 m 3 /hr 3 m/s 969 m 3 /hr 1132 m 3 /hr 1220 m 3 /hr 6 m/s 1068 m 3 /hr 1248 m 3 /hr 1307 m 3 /hr *In accordance to AS/NZS 4740:2000 nominal performance parameters, as per cl3.5 at h = 6m, T = 14oC, T = 20o PERFORMANCE Natural wind ventilators must be manufactured in Australia and in an ISO 9001 certified factory. They must: Be tested in accordance to the Australian and New Zealand standard AS/NZS 4740:2000 Performance of Natural Ventilation. Have the tested capability of withstanding wind speed of 205.2km/hr. FINISHES Available in a mill or a range of powder coat colours upon request ACCESSORIES When specified, accessories such as manual damper, electric damper, EC damper grilles, and special bases (spigot, square to round and EX Base) are available upon request. WARRANTIES CSR Building Products Limited ABN 55 008 631 356 T/A Edmonds ( Edmonds ) warrants from the date of install, for a period of FIFTEEN (15) YEARS that the Edmonds Hurricane Natural Ventilator turbine and body will retain its performance characteristics and be free from faulty materials and workmanship on the condition that the vent is installed in accordance to the installation instructions. Please refer to Warranty Document on edmonds.com.au for full details. 13

. ISO 9001 EXPLODED VIEW H700 - H800 ALUMUNIUM DOME GLASS REINFORCED NYLON 6 BEARING HOLDER & HOLDER ARMS UPPER BEARING ALUMINIUM TURBINE/IMPELLER ALUMINIUM SHAFT SPIDER BRACKET LOWER BEARING ALUMINIUM THROAT & BRACKETS ALUMINIUM VARIPITCH ALUMINIUM FLASHING 14

. ISO 9001 PRODUCT DIMENSION & WEIGHT H700 - H800 Turbine, Varipitch and Flashing 1 A (OD) H700 - H800 E D B (ID) C A : Overall turbine diameter B : Internal diameter of flashing opening C: Flashing Overall D : Clearance flashing to turbine E : Overall Height In Metric Units In Imperal Units Dimensions*(mm) Dimensions # (inches) Roof Slope Range Roof Slop Range A B C D E kg A B C D E lb H700 876 695 1000 x 1000 371 796 15.80 0-22.5 H700 34.5 27.36 39.4 x 39.5 14.6 31.3 34.83 0-22.5 H800 1003 792 1200 x 1200 393 848 20.60 0-22.5 H800 39.5 31.18 47.2 x 47.2 15.5 33.4 45.42 0-22.5 * Tolerance is within +/- 5mm and +/- 0.5kgs # Tolerance is within +/- 0.2 inches and +/- 1.1lbs 1 The Hurricane throat overlaps the Varipitch. The height listed above is with the maximum overlap (lowest overall height). Revolving the Varipitch to suit a roof slope also reduces the complete ventilator s overall height. 15

. ISO 9001 PRODUCT DIMENSION & WEIGHT H700 - H800 Turbine A (OD) G F F (ID) A : Overall turbine diameter F : Effective inner throat opening area G: Overall turbine only height In Metric Units In Imperal Units Dimensions* (mm) Dimensions # (inches) A F G kg A F G lb H700 876 705 556 11.60 H700 34.5 27.8 21.9 25.57 H800 1003 799 590 14.90 H800 39.5 31.5 23.2 32.85 * Tolerance is within +/- 5mm and +/- 0.5kgs # Tolerance is within +/- 0.2 inches and +/- 1.1lbs 16

PRODUCT CLASSIFICATION AND PERFORMANCE H700 - H800 PRODUCT INFORMATION SUMMARY Ventilator Range Hurricane Ventilator H700 H800 H700 - H800 Ventilator Type Type 4 - Rotating wind-driven roof ventilator Ventilator Performance Class (AS/NZS 4740:2000 Table 1.2) Rain Resistance 50 m/s No Water - Class A 50 m/s No Water - Class A Effective Aerodynamic Area, EAA 0.193 m 2 0.298 m 2 Effective Aerodynamic Area, C d 0.54 - Class 2 0.64 - Class 2 Flow Coefficient, C f 0.12 - Class 4 0.16 - Class 4 Wind Loading 57m/s - Level 1 57m/s - Level 1 Nominal Performance* (m 3 /hr) 0 m/s 1650 m 3 /hr 2546 m 3 /hr 3 m/s 1669 m 3 /hr 2597 m 3 /hr 6 m/s 1068 m 3 /hr 2746 m 3 /hr *In accordance to AS/NZS 4740:2000 nominal performance parameters, as per cl3.5 at h = 6m, T = 14oC, T = 20o PERFORMANCE Natural wind ventilators must be manufactured in Australia and in an ISO 9001 certified factory. They must: Be tested in accordance to the Australian and New Zealand standard AS/NZS 4740:2000 Performance of Natural Ventilation. Have the tested capability of withstanding wind speed of 205.2km/hr. FINISHES Available in a mill or a range of powder coat colours upon request ACCESSORIES When specified, accessories such as manual damper, electric damper, EC damper grilles, and special bases (spigot, square to round and EX Base) are available upon request. WARRANTIES CSR Building Products Limited ABN 55 008 631 356 T/A Edmonds ( Edmonds ) warrants from the date of install, for a period of FIFTEEN (15) YEARS that the Edmonds Hurricane Natural Ventilator turbine and body will retain its performance characteristics and be free from faulty materials and workmanship on the condition that the vent is installed in accordance to the installation instructions. Please refer to Warranty Document on edmonds.com.au for full details. 17

. ISO 9001 EXPLODED VIEW H900 ALUMUNIUM DOME GLASS REINFORCED NYLON 6 BEARING HOLDER & HOLDER ARMS UPPER BEARING ALUMINIUM TURBINE/IMPELLER STAINLESS STEEL SHAFT SPIDER BRACKET LOWER BEARING ALUMINIUM THROAT & BRACKETS ALUMINIUM VARIPITCH ALUMINIUM FLASHING 18

. ISO 9001 PRODUCT DIMENSION & WEIGHT H900 Turbine, Varipitch and Flashing 1 A (OD) H900 E D B (ID) C A : Overall turbine diameter B : Internal diameter of flashing opening C: Flashing Overall D : Clearance flashing to turbine E : Overall Height In Metric Units In Imperal Units Dimensions*(mm) Dimensions # (inches) Roof Slope Range Roof Slop Range A B C D E kg A B C D E lb H900 1096 891 1200 x 1200 421 936 24.10 0-22.5 H900 43.1 35.08 47.2 x 47.2 16.6 36.9 53.13 0-22.5 * Tolerance is within +/- 5mm and +/- 0.5kgs # Tolerance is within +/- 0.2 inches and +/- 1.1lbs 1 The Hurricane throat overlaps the Varipitch. The height listed above is with the maximum overlap (lowest overall height). Revolving the Varipitch to suit a roof slope also reduces the complete ventilator s overall height. 19

. ISO 9001 PRODUCT DIMENSION & WEIGHT H900 Turbine A (OD) G F (ID) F A : Overall turbine diameter F : Effective inner throat opening area G: Overall turbine only height In Metric Units In Imperal Units Dimensions* (mm) Dimensions # (inches) A F G kg A F G lb H900 1096 897 643 18.10 H900 43.1 35.3 25.3 39.90 * Tolerance is within +/- 5mm and +/- 0.5kgs # Tolerance is within +/- 0.2 inches and +/- 1.1lbs 20

PRODUCT CLASSIFICATION AND PERFORMANCE H900 PRODUCT INFORMATION SUMMARY Ventilator Range Hurricane Ventilator Ventilator Type H900 Type 4 - Rotating wind-driven roof ventilator Ventilator Performance Class (AS/NZS 4740:2000 Table 1.2) Rain Resistance 50 m/s No Water - Class A H900 Effective Aerodynamic Area, EAA 0.374 m 2 Effective Aerodynamic Area, C d 0.63 - Class 2 Flow Coefficient, C f 0.17 - Class 4 Wind Loading 57m/s - Level 1 Nominal Performance* (m 3 /hr) 0 m/s 3194 m 3 /hr 3 m/s 3267 m 3 /hr 6 m/s 3477 m 3 /hr *In accordance to AS/NZS 4740:2000 nominal performance parameters, as per cl3.5 at h = 6m, T = 14oC, T = 20o PERFORMANCE Natural wind ventilators must be manufactured in Australia and in an ISO 9001 certified factory. They must: Be tested in accordance to the Australian and New Zealand standard AS/NZS 4740:2000 Performance of Natural Ventilation. Have the tested capability of withstanding wind speed of 205.2km/hr. FINISHES Available in a mill or a range of powder coat colours upon request ACCESSORIES When specified, accessories such as manual damper, electric damper, EC damper grilles, and special bases (spigot, square to round and EX Base) are available upon request. WARRANTIES CSR Building Products Limited ABN 55 008 631 356 T/A Edmonds ( Edmonds ) warrants from the date of install, for a period of FIFTEEN (15) YEARS that the Edmonds Hurricane Natural Ventilator turbine and body will retain its performance characteristics and be free from faulty materials and workmanship on the condition that the vent is installed in accordance to the installation instructions. Please refer to Warranty Document on edmonds.com.au for full details. 21