CHAPTER II-1 D. Construction subdivision and stability, machinery and electrical installations

Similar documents
CHAPTER II-1 C. Construction subdivision and stability, machinery and electrical installations

PART 10 ELECTRICAL INSTALLATIONS

PART 8 ELECTRICAL INSTALLATIONS

HAZARDOUS AREA CLASSIFICATION (APPLICATION OF SOLAS REGULATION II-1/45.11)

ELECTRICAL INSTALLATIONS

RULES FOR THE CLASSIFICATION AND CONSTRUCTION OF SEA-GOING YACHTS ELECTRICAL INSTALLATIONS 2013 PART V GDAŃSK

E-12 Low-voltage Switchboard

ELECTRICAL INSTALLATIONS

Unified requirements for systems with voltages above 1 kv up to 15 kv

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

E-15 Uninterruptible Power Systems (UPS)

E-12 Low-voltage Switchboard

E-15 Uninterruptible Power Systems (UPS)

United Stales COMDPTPUB P Coast Guard NVIC Mar 191

Small craft Electric propulsion system

RULES FOR THE CLASSIFICATION AND CONSTRUCTION OF INLAND WATERWAYS VESSELS

Chapter 14:08 Factories and Works (Electrical) Regulations, Chapter 14:08 Factories and Works (Electrical) Regulations, 1976

Course Semester Subject Code Subject Name B.E EEE(M) V UAEE507 MARINE ELECTRICAL TECHNOLOGY UNIT-I

RULES FOR THE CLASSIFICATION OF SHIPS

Unarmoured Single-Core Cables to BS6883

MSC Guidelines for Steering-Gear Electrical Systems

RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF SHIPS IDENTIFIED BY THEIR MISSIONS CHAPTERS APPROACH

(Chapter II-1, Regulations 29.1, , 29.3, 29.4, , 29.14, 28.2 and 28.3 and 30.2)

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

PART 8 MACHINERY INSTALLATIONS

Hazardous areas, as found around a service station, are classified into three zones as follow: Table 1: Zone Classification for Vapours

CHAPTER 2: ELECTRICAL SAFETY

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy

ALTERNATE COMPLIANCE PROGRAM

Amendment of UN ECE R100 regarding in-use requirements for vehicles of category L Status:

(Chapter II-1, Regulations 29.1, , 29.3, 29.4, , 29.14, 28.3 and 30.2)

90.2 Scope. The installation of electrical conductors, equipment and raceways for:

casualty information Dear Captain General Requirements Encl.: 7 pages

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

ALPHA MARINE CONSULTING LTD. 26, SKOUZE STR PIRAEUS GREECE

DEPARTMENT OF MARINE SERVICES AND MERCHANT SHIPPING (ADOMS) REGULATORY AMENDMENTS ENTERING INTO FORCE DURING JANUARY 2017

MSC Guidelines for Electrical Plans Small Passenger Vessels

E/ECE/324/Rev.2/Add.104/Rev.2/Amend.3 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2/Amend.3

BSS Examination Record Form for Privately Owned and Managed Vessels

N-03 STEERING GEAR CONTROL SYSTEMS

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

Mechanical, hydraulic and electrical independency of steering gear control systems

IMO REQUIREMENTS JULY 2018 TO MAY 2021

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE SA MARITIME QUALIFICATIONS CODE. Deck: Ship s Power Plants

REDUNDANT PROPULSION SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 2

OPERATIONS SEAFARER CERTIFICATION GUIDANCE NOTE. Level 3 Assessment Chief and Second Engineer <3000kW

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

INTER PLANT STANDARD - STEEL INDUSTRY SPECIFICATION FOR AC CABIN FAN. Corresponding IS does not exist IPSS:

part three electrical installations

RSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2

Inspecting Airport Fueling Systems

(Chapter II-1, Regulations 29.1, , 29.3, 29.4, , 29.14, 28.2 and 28.3)

User Manual Rittal PMC UPS 6kVA

Maintenance Checklist

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

EARTHING YOUR QUESTIONS ANSWERED

Amendment of UN ECE R100 regarding in-use requirements for vehicles of category L Status: RESS-9-6 Rev.02

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES. Comments on document FP 46/5/8. Submitted by Japan

Australian/New Zealand Standard

Section 4 SURVEYS SPECIAL SHIP TYPES

Sector Baltimore Small Passenger Vessel Branch Initial Certificate of Inspection (ICOI) Work Instruction

(Chapter II-1, Regulations 29.1, , 29.3, 29.4, , 29.14, 28.2 and 28.3)

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

ELECTRICAL INSTALLATIONS

IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

PART II RULES FOR THE CONSTRUCTION AND CLASSIFICATION OF MOBILE OFFSHORE DRILLING UNITS MOBILE OFFSHORE DRILLING UNITS SECTION 7 ELECTRICITY CHAPTERS

Small craft Electrical systems Alternating current installations

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

ST. VINCENT AND THE GRENADINES

Wilkins Safety Group

EU RO Mutual Recognition Technical Requirements

E/ECE/324/Rev.2/Add.140 E/ECE/TRANS/505/Rev.2/Add.140

LED Emergency Luminaires

Task By Course 7.1D This task is covered for engineers in the Leadership and Managerial Skills course

Operating Instructions

Managing Electrical Safety on Boats

Diesel Engines for Fire Protection Applications

Investigation into UK socket-outlets incorporating USB charging points

Effective discrimination of protective devices

in-use requirements for vehicles of category L (Part 1) IMMA contribution to 10/RESS

The Impact of the 18 th edition (BS 7671:2018)

AIR LUBRICATION SYSTEM INSTALLATION

Electrical test equipment for use on low voltage electrical systems

INTERNATIONAL STANDARD

CHAPTER 10 ELECTRICAL. Notes:

ICOMIA Global Conformity Guideline for ISO and ABYC Standards. Guideline Number 8 Ventilation of fuel systems

Temporary Sales Trailer Application

PROTECTION OF THE BRANCH CIRCUIT

UNITED STATES OF AMERICA CIVIL AERONAUTICS BOARD WASHINGTON, D.C.

INTERNATIONAL STANDARD

Chapter 5. Imagine That Engineering Inc. Assured Equipment Grounding Conductor Program (AEGCP) Ground Fault Circuit Interrupter (GFCI)

GT/TDINT100 Issue: 1 Date: SEP 1993 Page 1 of 11

Contents. Chapter No. Title Page No. 1 Overview of a Ship s Electrical System 1. 2 Electrical Safety 41

E/ECE/324/Rev.2/Add.104/Rev.2 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

ELECTRICAL INSTALLATIONS

Part 4 Systems and components Chapter 1 Machinery systems, general

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Transcription:

Only the Danish version is authentic Notice D II-1 D 1 October 2002 Technical regulation on the construction and equipment, etc. of passenger ships on domestic voyages CHAPTER II-1 D Construction subdivision and stability, machinery and electrical installations Regulation 1 General (R 40)...2 Regulation 2 Main source of electrical power and lighting (R 41)..2 Regulation 3 Emergency source of electrical power (R 42)...3 Regulation 4 Supplementary emergency lighting for ro-ro ships (R 42-1)...5 Regulation 5 Precautions against shock, fire and other hazards of electrical origin (R 45)...5

CHAPTER II-1 D Construction subdivision and stability, machinery and electrical installations Part D Electrical installations Regulation 1 General (R 40).1 Electrical installations shall be such that:.1 all electrical auxiliary services necessary for maintaining the ship in normal operational and habitable conditions will be ensured without recourse to the emergency source of electrical power;.2 electrical services essential for safety will be ensured under various emergency conditions; and.3 the safety of passengers, crew and ship from electrical hazards will be ensured..2 The Administration of the flag State shall take appropriate steps to ensure uniformity of implementation and application of the provision of this part in respect of electrical installations. 1 Regulation 2 Main source of electrical power and lighting (R 41).1 New ships of class C and D in which the electrical power is the only power for maintaining the auxiliary services essential for the safety of the ship, and new and existing ships of class B in which the electrical power is the only power for maintaining the auxiliary services essential for the safety and the propulsion of the ship, shall be provided with two or more main generating sets of such power that the aforesaid services can be operated when any one sets is out of service. In new class C and D ships of less than 24 metres in length, one of the main generating sets may be main propulsion engine driven, provided it is of such power that the aforesaid services can be operated when any one other set is out of service..2.1 A main electric lighting system which shall provide illumination throughout those parts of the ship normally accessible to and used by passengers or crew shall be supplied from the main source of electrical power..2.2 The arrangement of the main electric lighting system shall be such that a fire or other casualty in spaces containing the main source of electrical power, associated transforming equipment, if any, the main switchboard and the main lighting 1 Reference is made to the recommendations published by the International Electrotechnical Commission and, in particular, Publication 92 Electrical Installations in Ships. 2

switchboard, will not render the emergency lighting system, required by regulation 3, inoperative..2.3 The arrangement of the emergency electric lighting system shall be such that a fire or other casualty in spaces containing the emergency source of electrical power, associated transforming equipment, if any, the emergency switchboard and the emergency lighting switchboard will not render the main electric lighting system required by this regulation inoperative..3 The main switchboard shall be so placed relative to one main generating station that, as far as is practicable, the integrity of the normal electrical supply may be affected only by a fire or other casualty in the space where the generating set and the switchboard are installed. Regulation 3 Emergency source of electrical power (R 42).1 Every ship shall be provided with a self-contained emergency source of electrical power with emergency switchboard located above the bulkhead deck, in a readily accessible space which shall not be contiguous to the boundaries of machinery spaces of category A or of those spaces containing the main source of electrical power or main switchboard..2 The emergency source of electric power may be either an accumulator battery capable of complying with the requirements of subparagraph.5, without being recharged or suffering an excessive voltage drop, or a generator, capable of complying with the requirements of paragraph.5, driven by internal combustion type of machinery with an independent supply of fuel having a flashpoint of not less than 43 C, with automatic starting arrangements for new ships and approved starting arrangements for existing ships, and provided with a transitional source of emergency electrical power according to paragraph.6, unless, in the case of new class C and D ships of less than 24 metres in length a suitably located independent battery arrangement is provided for that particular consumer for the period of time required for these regulations..3 The emergency source of electric power shall be so arranged that it will operate efficiently when the ship is listed to 22.5 and when the trim of the ship is 10 from an even keel. Emergency generator set(s) shall be capable of being readily started in any cold condition likely to be encountered and, in new ships, capable of being started automatically..4 The emergency switchboard shall be situated as near as practicable to the emergency source of power..5 The emergency source of power required by paragraph.1 shall:.1 be capable of operating in general for a period of: 12 hours for class B ships (new and existing) 6 hours for class C ships (new) 3 hours for class D ships (new);.2 in particular, be capable to operate simultaneously the consumers as identified within the following services as 3

required for the class of ships for the times indicated above: (a) the ship s emergency bilge pump and one of the fire pumps; (b) emergency lighting: 1. at every assembly or embarkation station and over the sides; 2. in all alleyways, stairways and exits giving access to the assembly or embarkation stations; 3. in the machinery spaces, and in the place where the emergency generator is situated; 4. in the control stations where radio and main navigating equipment are situated; 5. as required in regulations II-2/B/16.1.3.7 and II- 2/B/6.1.7; 6. at all stowage positions for firefighter s outfits; 7. at the emergency bilge pump and one of the fire pumps, referred to in subparagraph (a) and at the starting position of their motors; (c) the ship s navigation lights; (d) 1. all communication equipment, 2. the general alarm system, 3. the fire detecting system, and 4. all signals which may be required in an emergency, if they are electrically operated from the ship s main generating sets; (e) the ship s sprinkler pump, if any and if it is electrically operated; and (f) the ship s daylight signalling lamp, if it is operated by the ship s main source of electric power;.3 be capable to operate, for a period of half an hour, the power-operated watertight doors together with the associated control, indication and alarm circuits..6 The transitional source of emergency electrical power required by paragraph.2 shall consist of an accumulator battery suitably located for the use in an emergency which shall operate without recharging or suffering an excessive voltage drop for half an hour: (a) the lighting required by paragraph.5.2(b)1 of this regulation; (b) the watertight doors, as required by paragraphs.7.2 and.7.3 of regulation II-1/B/13, but not necessarily all of them simultaneously, unless an independent temporary source of stored energy is provided; and (c) the control, indication and alarm circuits as required by paragraph.7.2 of regulation II-1/B/13..7 CLASS B, C AND D SHIPS, CONSTRUCTED ON OR AFTER 1 JULY 2002: Where electrical power is necessary to restore propulsion, the capacity shall be sufficient to restore propulsion to the ship in 4

conjunction with other machinery, as appropriate, from a dead ship condition within 30 min. after blackout. Regulation 4 Supplementary emergency lighting for ro-ro ships (R 42-1) In addition to the emergency lighting required in regulation II- 1/D/3.5.2(b), on every ship with ro-ro cargo spaces or special category spaces:.1 all passenger public spaces and alleyways shall be provided with supplementary electric lighting that can operate for at least three hours when all other sources of electrical power have failed and under any condition of heel. The illumination provided shall be such that the approach to the means of escape can be readily seen. The source of power for the supplementary lighting shall consist of accumulator batteries located within the lighting units that are continuously charged, where practicable, from the emergency switchboard. Alternatively, any other means of lighting which is at least as effective may be accepted by the Administration of the flag State. The supplementary lighting shall be such that any failure of the lamp will be immediately apparent. Any accumulator battery provided shall be replaced at intervals having regards to the specific service life in the ambient conditions that they are subject to in service; and.2 a portable rechargeable battery operated lamp shall be provided in every crew space alleyway, recreational space and every working space which is normally occupied unless supplementary emergency lighting, as required by paragraph.1 is provided. Regulation 5 Precautions against shock, fire and other hazards of electrical origin (R 45).1 Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed unless the machines or equipment are:.1 supplied at a voltage not exceeding 50 V direct current or 50 V, root mean square, between conductors; autotransformers shall not be used for the purpose of achieving this voltage; or.2 supplied at a voltage not exceeding 250 V by safety isolating transformers supplying only one consuming device; or.3 constructed in accordance with the principle of double insulation..2 All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner..3 The sides and the rear and, where necessary, the front of switchboards shall be suitably guarded. Exposed live parts having voltages to earth exceeding the voltage specified under 1.1 shall not be installed on the front of such switchboards. 5

Where necessary, non-conducting mats or gratings shall be provided at the front and rear of the switchboard..4 In distribution systems with no connection to earth, a device capable of monitoring the insulation level to earth and giving an audible or visual indication of abnormally low insulation values shall be provided..5.1 All metal sheaths and armour of cables shall be electrically continuous and shall be earthed..5.2 All electrical cables and wiring external to equipment shall be at least of a flame-retarding type 2 and shall be so installed as not to impair their original flame-retarding properties. Where necessary for particular application the Administration of the flag State may permit the use of special type of cables such as radio frequency cables, which do not comply with the foregoing. NEW CLASS B, C AND D SHIPS:.5.3 3 Cables and wiring serving essential or emergency power, lighting, internal communications or signals shall so far as practicable be routed clear of galleys, laundries, machinery spaces of category A and their casings and other high fire risk areas. In new and existing ro-ro passenger ships, cabling for emergency alarms and public address systems installed on or after the date referred to in Article 14(1) of this Directive shall be approved by the Administration of the flag State having regard to the recommendations developed by the IMO. 4 Cables connecting fire pumps to the emergency switchboard shall be of a fire-resistant type 5 where they pass through high fire risk areas. Where practicable all such cables should be run in such a manner as to preclude their being rendered unserviceable by heating of the bulkheads that may be caused by a fire in an adjacent space..6 Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical flame-retarding and, where necessary, fire resisting..7.1 Each separate circuit shall be protected against short circuit and against overload, except as permitted in regulations II- 1/C/6 and II-1/C/7. NEW CLASS B, C AND D SHIPS:.7.2 Lighting fittings shall be so arranged as to prevent temperature rises which could damage the cables and wiring, and to prevent surrounding material from becoming excessively hot..8.1 Accumulator batteries shall be suitably housed, and compartments used primarily for their accommodation shall be properly constructed and efficiently ventilated. 2 3 4 5 Shall be made in accordance with IEC Standard no. 331 or 332. Shall be made in accordance with IEC Standard no. 331 or 332. Reference is made to MSC/Circ.808, Recommendations on cable-laying for emergency alarms and public address systems. Shall be made in accordance with IEC Standard no. 331 or 332. 6

.8.2 Electrical or other equipment which may constitute a source of ignition of flammable vapours shall not be permitted in these compartments..9 Distribution systems shall be so arranged that fire in any main vertical zone, as is defined in regulation II-2/A/2.9, will not interfere with services essential for safety in any other such zone. This requirement will be met if main and emergency feeders passing through any such zone are separated both vertically and horizontally as wide as is practicable. 7