Wind Speed Meter TUMI 30 DAE

Similar documents
Wind Anemometer WS-S-CL Marine Model

METEOROLOGICAL INSTRUMENTS

MODEL 27106DT GILL PROPELLER ANEMOMETER JANUARY 2003 MANUAL PN 27106DT-90 R. M. YOUNG COMPANY

METEOROLOGICAL INSTRUMENTS

DPT TARGET TYPE FLOWMETERS

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS

GE Sensing & Inspection Technologies

METEOROLOGICAL INSTRUMENTS

canfield connector 8510 Foxwood Court Youngstown, Ohio (330) Fax: (330)

Operating Instructions Type MPT 53

mass flowmeter for compressed air

Low Pressure Sensor. Overview. Specifications. Installation and Operation

ANEMOMETER Vaisala WAA252

METEOROLOGICAL INSTRUMENTS

Micro Response Anemometer Model User s Manual National Drive Sacramento, CA

SENSORS CLIMATRONICS CORPORATION (631) MANUAL - F460 WIND DIRECTION SENSOR P/N M Rev C. Figure 1. Figure 2

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

METEOROLOGICAL INSTRUMENTS

MARCH 2002 MANUAL PN 05103L-90

TURBINE METERS - WP Series

ECONOMISER SERIES E2T USER MANUAL

MODEL 05305L WIND MONITOR-AQ WITH

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

Wind Direction Vane. Z345. Installation Guide.

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Operating instructions Electronic level sensor LK7 / LK /07 04/2006

METEOROLOGICAL INSTRUMENTS

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

MODEL 422 Submersible Pump Controller

MODEL PC-252 Transformer Temperature Indicator Oil & Winding Temperature Indicator (with Micro Switches)

Electric Actuator Installation, Operation & Maintenance Manual

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

A1P OPERATING MANUAL

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

METEOROLOGICAL INSTRUMENTS

SIGNET Temperature Transmitter

LAYCOCK SYSTEMS, INC N. 43 rd Street Tampa, FL

Operating Instructions Pedestrian Turnstile Type MPT 33

MODEL 12002/12005 GILL MICROVANE & 3-CUP ANEMOMETER MODEL GILL 3-CUP ANEMOMETER MODEL 12302/12305 GILL MICROVANE APRIL 1994

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

PLC Controlled High Performance Automatic Grease Lubricator

METEOROLOGICAL INSTRUMENTS

Appendix. Clearance. Skewed profiles. Application Schematics

VTC610 Series Voltage Converter. Installation & Operation Manual

METEOROLOGICAL INSTRUMENTS

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

TELEMOTIVE APPENDIX F 10K Stepless Electronic Transfer Switch

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

CABINET REEL OPERATING INSTRUCTIONS

Product Information Page

TABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure

MODEL 27106T GILL PROPELLER ANEMOMETER

METEOROLOGICAL INSTRUMENTS

Quarter Master Series 94 Actuator

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Switch select of sender types:

5001TCP SPEED CONTROLLER

Quarter Master Chief Series 92 Actuator

TECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale

Stack Light- Light Only. Stack Light with Sound

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Signet 2551 Magmeter Flow Sensor

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

TS93 EMF T/PT/TDE. Surface applied door closer

Single or Double 240VAC motor control for domestic and industrial gates and doors.

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Product Application Guide- 30mm Stacklights. 30 mm Stacklight- Light Only

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

Pneumatic Positioner PNY Series USER'S MANUAL. Max-Air Technology. Version 1.0

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

Signet Temperature Transmitter

METEOROLOGICAL INSTRUMENTS

Carbon Monoxide Transmitter

CP-1TT Remote System

METEOROLOGICAL INSTRUMENTS

Damper Actuator Installation

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

PILATUS AIRCRAFT LTD. CH-6371 STANS, SWITZERLAND SERVICE BULLETIN SERVICE BULLETIN NO: REF NO: 184 MODIFICATION NO: ATA CHAPTER: 32

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

VTC1000 Series Voltage Converter. Installation & Operation Manual

Surepowr Series 100 Installation Manual

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

B100S - Super Swing. Instruction Manual. Document number: B100S-C Release: V4.0 Date: May 08,2009

Removal and Installation Guidelines

ASYN205B Central Synchronizing Controller

Transcription:

OPERATION MANUAL Wind Speed Meter TUMI 30 DAE TGA-6 TUMI-30-DAE - meteorologic station, ships, tug boats, - tanks, towers, power stations, - oil rafts, seaports, airports, cranes etc. with 1 to 4 adjustable relay alarms

OPERATION MANUAL Wind Speed Meter TUMI 30 DAE Contents: Technical data Installation Wiring TGA-6 Spare parts Calibration table Order instructios TGA-6 TUMI-30-DAE TECHNICAL DATA: TRANSMITTER: Type: : TGA-6 Measurement range : 0 to 60 m/s Starting speed : 0.7 m/s Accuracy FS : +-0.2 m/s or + - 2 % Operating temp. : -40...+50 C Ball bearing : stainless St, Dimensions : o170 * 300 mm. OPTIONS: Transmitter heating : TGA-6-L ( 3 W max.) DISPLAY UNIT: Type : TUMI 30 DAE Range : 0...30 m/s Accuracy : +-0.2 m/s or + - 2 % Operating temp. : 0...+50 C Voltage : 24 VDC, 5 W Dimensions : 175*125*75 mm3. OPTIONS: Voice alarm, pot.adjust.: -A internal buzzer, Relay alarm, pot.adjust. 1 : -R 1 pcs. relay Relay alarm, pot.adjust. 2 : -2R 2 pcs. relay Relay alarm, pot.adjust. 3 : -3R 3 pcs. relay Relay alarm, pot.adjust. 4 : -4R 4 pcs. relay Delay for one alarm : 2 to 12 sec. Power options : 230 VAC, or 120 VAC, Different scales : km/t, MPH, KNOT, GUARANTEE: REHN Ky issues a guarantee for the material and workmanship of this product for twelve (12) months from the date of delivery. Damage due to exceptional operation conditions, careless handling or misapplication will void the guarantee. Serial No. Date of delivery: QC:

TUMI 30 DAE, TGA-6: INSTALLATION TRANSMITTER TGA-6: 170 mm The transmitter is fastened to the pedestal with two M6 hexagonal screws. In vibrating conditions the hexagonal screws can be replaced by rubber schock absorbers, which are delivered as an additional equippment. The transmitter cable is attached with a spacing small enough by means of clamps or bands. The lid of the case is opened and the wires are connected to the srews of the terminal. 330 mm The lid is closed carefully to ensure the rubberbascet to tighten the case waterproof. 60 mm TGA-6 CENTRAL UNIT TUMI: The central unit is installed on the wall using four screws. 107 mm The supply wire is of 3*0,75 mm2 size. Terminal block number 1. = *), L / + Terminal block number 2. = *), N / - Terminal block number 3. = Protective ground. Transmitter cable is of 2 or 3 * 0,75 mm2 size. 157 mm 175 mm *) 24 VDC 115 VAC, 60 Hz, 230 VAC, 50 Hz The alarm is preset at delivery to specifications of the customer. Adjust the potentiometers for a wished alarm value. 125 mm Pg 11

TUMI 30 DAE, TGA-6: INSTALLATION TGA-6 Transmitter TUMI-30-DAE Central Unit

TUMI 30 DAE: WIRING, Meter TUMI POWER ALARMS TRANSMITTER Wind Meter TUMI-XXX-DAE-XX-XXX Alarms [m/s]: R1 + Buzzer = R2 = R3 = R4 =

TUMI 30 DAE: WIRING, Transmitter TGA-6

TUMI 30 DAE, TGA-6: SERVICE INSTRUCTION 1 TRANSMITTER TGA-6: The bearing of the transmitter is normally looked over once a year. In a dusty environment inspect more frecuently. The inspection is performed by rotating the grid of the cups and by listening to the sounding of the bearing. A clean bearing rotates smoothly and noiseless, but a dirty bearing stops in a jerking motion and gives a snapping sound. 3 kpl M3 * 8-10 mm SSt M4 * 5 mm SSt SSt 626-2Z-J-P5-LU TGA-6 Anemometer If the bearing is dirty, the prosedure is as follows: 1. The tree lockscrews of the rotating cup unit are opened with an allen key (M3) and the unit is removed. 2. The lockscrew of the bearing is removed and the bearing is taken out. 3. The bearing is a continuous lubrication and fitted with a coverplate. If the bearing is dirty, replace with new one. The bearing can also be opened cleaned and lubricated. The type of the bearing: GMN SSt 626-2Z-J-P5-LU The lubricant: AERO SHELL FLUID 12 / MIL-L-6085A (or equivalent) The working temperature range of the oil is -40...+55 C. The bearing can also equipped with heating, the heating is switching on when the temperature goes below + 4 C. 4. A new or cleaned bearing is installed. 5. The grid of the cup is installed and locking screws are fastened. NOTE: The locking screws of the grid are only turned to the bottom and not tightened to tense (deformation of the bearing) The locking srews should be lock itselfs by using adhessive lock material (silicon, srew lock, or similar) which is unlocked later. The main point is confirm that screws not open in shaking conditions. The locking of the unit is checked by lifting upwards the grid. 6. Rotate the grid. The grid of the cups has stop smoothly. If the grid stops at once and jerking, the locking screws are fight and they must loosened a little.

TUMI 30 DAE, TGA-6: TO REPLACE A BROKEN TRANSMITTER CUP: 1. Remove the grid of the cups as per instructions page 4. 2. The shaft of the broken cup is cut off at the root and with a o 6.0 mm drill in the previous location of the shaft a 6.0 deep hole is drilled perpendicular to the center. 3. To increase adhesion rough on the surface of the hole and the shaft of the new cup. 4. Use ARALDIT RAPID or eqivalent (epoxy) glue to bond the cup, remove extra glue from the joint. 5. Check that the cup is correctly and perpendicular to the rotating axle. Check the rotating radius to be according to the drawing. This measurements affects the balance and speed of the rotation. 6. Let the bonded joint dry up correctly. ( See the instructions of glue). 7. Install the grid of the cups according to instructions page 4.

HUOLTO Varaosat TGA-6 Anturi SERVICE SPARE PARTS TGA-6 Transmitter

TUMI 30 DAE TGA-6 SERVICE Calibration Wind Speed / Frequency Calibration is checked by wind tunnel of Tampere University of Technology. Wind speed m/s versus anemometer frequency (small AC 0 to abt. 2-3 Volt pp) : RT1 RT2 MP1 Rcal1 Rcal2 Transmitter A=GND, C=signal, (B=+24VDC heating option) The calibration check: 1. Get Frequency Generator / Frequency Counter and Voltage Meter. 2. Connect VM to MP1 and GND, FG and FC to transmitter input A and C, set FG sine 2-3 volts AC, set FG to speed / frequency f.e. 15 m/s, 94,5 1/s 3. Set first trimmer Rcal1 so that VM is 2,5 V (15 m/s) and Rcal2 so that Speed Meter meter display correct speed (15 m/s) Wind Speed m/s frequency 1/s 1 6,3 2 12,6 3 18,9 4 25,2 5 31,5 6 37,8 7 44,1 8 50,4 9 56,7 10 63,0 11 69,3 12 75,6 13 81,9 14 88,2 15 94,5 16 100,8 17 107,1 18 113,4 19 119,7 20 126,0 21 132,3 22 138,6 23 144,9 24 151,2 25 157,5 26 163,8 27 170,1 28 176,4 29 182,7 30 189,0 X 35 220,5 X 40 252,0 X 45 283,5 X 50 315,0 4. Set first alarm potentiometer (front plate 15 m/s) and adjust trimmer RT1 so that alarm connect when Speed Meter meter display same speed. 5. Repeat with needed speed/fequency pair. Connect transmitter cable.

TUMI Wind Meter Order instructios TUMI can be equipped with several options and measurement scales: Transmitter TGA-6 (anemometer) TGA-6 Wind Transmitter, 6 pulse / rev. TGA-6-L Wind Transmitter, 6 pulse / rev. with heating (24 VDC, 3 W) TUMI Wind Meter Scale -30 0 to 30 m/s ( meter size: 65 * 85 mm2. ) Scale options: -15 0 to 15 m/s ( meter size: 65 * 85 mm2. ) -40 0 to 40 m/s / 80 knots ( meter size: 144 * 144 mm2. ) -160 KMPH 0 to 160 km/h / 100 mph. ( meter size: 144 * 144 mm2. ) -XX YYY 0 to max.value of speed quality Type DAE D For digital pulse transmitter TGA-6 ( 6 pulses/rev. ) A Analog current output, normally 0-1 ma ( calibrated for specified scales ) E Case, 125 * 175 * 75 mm3. polycarbonate DAE DAE1 equipped with with standard analog meter in case no analog meter in case. Power supply: -24 24 VDC -115 115 VAC, 50-60 Hz -230 230 VAC, 50 Hz dafault Alarm options: -AR1 -AR2 -AR3 -AR4 One adjustable alarm, A=buzzer, R= relay Two adjustable alarm, A=buzzer, R= relay ( Buzzer is parallel with first relay) Tree ajustable alarm, A=buzzer, R= relay ( Buzzer is parallel with first relay) Four adjustable alarm, A=buzzer, R= relay ( Buzzer is parallel with first relay) Other options: -D Delay, internally adjustable 1-12 sec. for relay 1. -R Reset circuit and button for the alarm when set up alarm permanent Special outputs: ( calibrated for specified scales ) -CL Current loop output for meter or logic, standard 0/4 to 20 ma, not isolated -020 Current loop output for meter or logic, standard 0 to 20 ma, fully isolated -420 Current loop output for meter or logic, standard 4 to 20 ma, fully isolated For example: TUMI-160KMPH-DAE1-24-AR2-D-020 Wind meter TUMI -160KMPH calibrated for 160 km/h, -DAE1 without display meter, -24 24 VDC power supply, -A2R buzzert and two adjustable relay alarms -D with delay -020 Current loop output for meter or logic, standard 0 to 20 ma, fully isolated