Type EV224B. Servo-operated 2/2-way solenoid valves for high pressure air. Data sheet

Servo-operated 2/2-way solenoid valves Type EV220A

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Servo piston operated 2/2-way solenoid valves for steam Type EV245B

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

Servo-operated 2/2-way solenoid valves for steam Type EV225B

Solenoid valve Types EV220B 15 - EV220B 50

MAKING MODERN LIVING POSSIBLE. Solenoid valves, 2/2-way assisted lift operated type EV251B Technical brochure

Solenoid valves 2/2-way servo operated type EV220B 15 50

Solenoid valve Types EV220B 15 - EV220B 50

Assisted lift operated 2/2-way solenoid valves Type EV250B

2/2-way assisted lift operated solenoid valve type EV250B

Indirect servo-operated 2/2-way solenoid valves Type EV220W 10 - EV220W 50, NBR and EPDM versions

Assisted lift operated 2/2-way solenoid valves Type EV251B

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

Solenoid valves for drinking water Types EV220BW and EV228BW

Solenoid valves 2/2-way servo-operated Type EV220B 15-50

Solenoid valves for water supply and steam inlet Types EV220T, EV220W, EV220B, EV225B, and AV210

Solenoid valves 2/2-way direct-operated Type EV210B

Servooperated. 2/2-way solenoid valves EV220A. The Home of Control & Automation in Ireland

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Solenoid valves 3/2-way direct-operated Type EV310A

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210A DKACV.PD.100.A B1023. August 2001

Solenoid coil Types BB, BE, BF, BG, and BN

2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO)

Externally operated valves Type AV210

Easy. Core Industrial Products for Distributors and Wholesalers. selection of future proof products. iasupport.danfoss.com

Solenoid valve VDHT Standard BSP (British Standard Pipe)

Solenoid valve 2/2 way N.C. With pilot control

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

High Pressure Valves

Solenoid valve VDHT standard BSP (British Standard Pipe)

Technical Data Sheet

2/2-way Solenoid Valve for liquids and gases

Solenoid valve for R410A and R744 Types EVR 2 - EVR 6 and EVRH 10 - EVRH 40

Solenoid valves Type EVU for fluorinated refrigerants

Series PD directly operated solenoid valves

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

2/2-way Solenoid Valve with servo diaphragm

Condensed Catalog 2006 North America

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE

how to use solenoid valves INDUSTRIAL CONTROLS DKACV.PS.600.A3.02 / 520B1389

Series PD directly operated solenoid valves

Solenoid valves Type EVU

Core Industrial Products for Distributors and Wholesalers in North America

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

2/2 Pressure operated valves

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

Solenoid coils. Data sheet

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

Solenoid valves VZWM-L, NPT

Miniature coil (3W) encapsulated in synthetic material. Connection with 3-pin DIN type B plug. Degree of protection IP 65.

Motorised Valve Range

2-way pilot operated solenoid valves for water, hot water and steam. Catalogue 8658/GB December 1999

Diaphragm : Plastic Metal Globe : Plastic Metal Manifold Pinch Valve

Angle Seat Valve 7010

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

PILOT OPERATED, 2/2 WAY, NORMALLY CLOSED, G 3/4 - G1. Pressure. Pressure Maximum For DC Voltage. Flow Coeffient. Maximum. For AC Voltage. L/m.

2/2 way Directional Control Valves, type VDH For inline mounting and Cetop 3 flange mounting (ISO 4401)

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT

Series RE-10. Valve terminals > Technical details. Order code RE-10/**-***-*** Temperature range Medium +5 C C

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Pilot Operated Pressure Relief Valve Series R5V (Denison)

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Series P directly operated solenoid valves

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

Examples 3/2-way valve A T NO: Symbol

Straight Bodied Flanged Valve 7030 DN 15 up to DN 150 PN 16

Solenoid System FLANGE MOUNTING VERSION

Solenoid valve Types EVR 2 EVR 40 NC/NO

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Valve Islands Series F

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Pneumatic Valve 4V100 Series

3/2-way Solenoid Valve for pneumatics

OPD min max a c max d c. code [ISO 228 G] [mm] [l/min] [barg] [barg] [barg] code [Volts/Hz]

Solenoid coils. Data sheet

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

82170/ /2-way diaphgram valves

MINIATURE SOLENOID VALVES diaphragm mechanism, fl uid isolation threaded connections M5-1/8

2/2 ) % ) % ) Assemblies. Solenoid and Piloted Piston Valve Series Condensate Drain Valve Assemblies. Brass or Stainless Steel Bodies 1/4" to 1" NPT

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

EVI 5 S13 Solenoid System

Type Modular Water Valve System servo-assisted; variable and extendable. 2/2 way; DN mm; 1 up to 7 bar Advantages / Benefits

Solenoid valves VZWP, servo-controlled

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

short name: 3WL.IG* technical product sheet created :57 1/6 3-way ball valve F/F PN 63 with pneumatic actuator hard anodized aluminum

Technical Principles of Valves

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Pilot valves for servo operated main valves

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Transcription:

Data sheet Servo-operated 2/2-way solenoid valves for high Type EV224B EV224B for compressed air, is a high indirect servo-operated 2/2-way solenoid valve with working up to 40 bar, medium temperature up to 60 C and available in NC and NO versions. Built-in pilot filter as standard, replaceable equalizing orifice, enclosures up to IP67 (depending on coil) ensure a reliable and satisfactory function. Features For compressed air and compressed air with mineral oil Differential : Up to 40 bar Ambient temperature: Up to 60 C Media temperature from -10 60 C Coil enclosure: Up to IP67 Thread connection: From G ½ G 1 Built in filter for protection of pilot system NC and NO versions DCS (rja) 2016.11 IC.PD.200.N8.02 1

Brass valve body, NC Connection ISO 228/1 Seal material Orifice size K v - value [m³/h] Differential, min. to max. BE / BB BE / BB BG 18 [W DC] 10 [W AC] 12 [W AC], 20 [W DC] Max. operating Max. test Min. burst acc. EN 12516 Media temperature min. to max. [ C] Code number G ½ NBR 15 4 0.3 40 0.3 40 0.3 40 40 60 159-10 60 032U8360 G ¾ NBR 20 8 0.3 35 0.3 35 0.3 35 35 53 142-10 60 032U8362 G 1 NBR 25 11 0.3 33 0.3 33 0.3 33 33 50 134-10 60 032U8364 Used with synthetic oils, and with media temperature between 40 60 C, life time can be reduced Brass valve body, NO Connection ISO 228/1 Seal material Orifice size K v - value [m³/h] Differential, min. to max. BE / BB BE / BB BG 18 [W DC] 10 [W AC] 12 [W AC], 20 [W DC] Max. operating Max. test Min. burst acc. EN 12516 Media temperature min. to max. [ C] Code number G ½ NBR 15 4 0.3 40 0.3 40 0.3 40 40 60 159-10 60 032U8361 G ¾ NBR 20 8 0.3 35 0.3 35 0.3 35 35 53 142-10 60 032U8363 G 1 NBR 25 11 0.3 33 0.3 33 0.3 33 33 50 134-10 60 032U8365 Used with synthetic oils, and with media temperature between 40 60 C, life time can be reduced Technical data Type EV224B Installation Max. test Ambient temperature Viscosity Vertical solenoid system is recommended. 64 bar Coil type: BB 10 W AC / 18 W DC Up to 60 C Coil type: BE 10 W AC / 18 W DC Up to 60 C Coil type: BG 12 W AC / 20 W DC Up to 60 C Max. 50 cst Materials Valve body: Brass W.no. 2.0402 Armature: Stainless steel W.no. 1.4105 / AISI 430FR Armature tube: Stainless steel W.no. 1.4306 / AISI 304L Armature stop: Stainless steel W.no. 1.4105 / AISI 430FR Diaphragm valve cone: Stainless steel W.no. 1.4404 / AISI 316L Springs: Stainless steel W.no. 1.4310 / AISI 301 O-rings: NBR Valve plate: NC: NBR / NO: PTFE Diaphragm: NBR DCS (rja) 2016.11 IC.PD.200.N8.02 2

Dimensions and weight, NC and NO Type L B B 1 Coil type BB / BE BG H H 1 Weight without coil [kg] EV224B 15 80 52 46 68 99 15 0.8 EV224B 20 90 58 46 68 103 18 1.0 EV224B 25 109 70 46 68 113 22 1.4 Dimensions Mounting angle 32U1788.10 32U1787.10 DCS (rja) 2016.11 IC.PD.200.N8.02 3

Below coils can be used with EV224B Coil Type Power consumption Enclosure Features BB, clip on AC: 11 16 W DC: 13 16 W IP00 with spade connector IP20 with protective cap, IP65 with cable plug BE, clip on AC: 11 17 W DC: 13 15 W IP67 With terminal box BG, clip-on AC: 11 16 W DC: 16 20 W IP67 With terminal box Accessories: Cable plug Application Code number GDM 2011 (grey) cable plug according to DIN 43650-A PG11 042N0156 DCS (rja) 2016.11 IC.PD.200.N8.02 4

Spare parts kit, NC 32U11789.10 Type Seal material Code number EV224B 15 NBR 032U6156 EV224B 20 NBR 032U6158 EV224B 25 NBR 032U6160 The kit contains: O-ring for coil Armature tube assembly Armature with valve plate and spring O-ring for the armature tube 2 O-rings for the equalizing orifice Closing spring Diaphragm 2 O-rings for the pilot system Spare parts kit, NO 32U1790.10 Type Seal material Code number EV224B 15 NBR 032U6157 EV224B 20 NBR 032U6159 EV224B 25 NBR 032U6161 The kit contains: O-ring for coil Armature unit assembly O-ring for the armature unit 2 O-rings for the equalizing orifice Closing spring Diaphragm 2 O-rings for the pilot system Spare parts kit for synthetic oil, NC/NO Type Seal material Code number EV224B 15 FKM 032U8118 EV224B 20 FKM 032U8119 The kit contains: Closing spring Diaphragm 2 O-rings for the pilot system DCS (rja) 2016.11 IC.PD.200.N8.02 5

Function, NC 1. Coil 2. Armature spring 3. Valve plate 4. Pilot orifice 5. Diaphragm 6. Main orifice 7. Equalizing orifice 32U846.10 Coil voltage disconnected (closed): When the voltage is disconnected, the valve plate (3) is pressed down against the pilot orifice (4) by the armature spring (2). The across the diaphragm (5) is built up via the equalizing orifice (7). The diaphragm closes the main orifice (6) as soon as the across the diaphragm is equivalent to the inlet. The valve will be closed for as long as the voltage to the coil is disconnected. Coil voltage connected (open): When voltage is applied to the coil (1), the pilot orifice (4) is opened. As the pilot orifice is larger than the equalizing orifice (7), the across the diaphragm (5) drops and therefore it is lifted clear of the main orifice (6). The valve is now open for unimpeded flow and will be open for as long as the minimum differential across the valve is maintained, and for as long as there is voltage to the coil. Function, NO 1. Coil 2. Armature spring 3. Valve plate 4. Pilot orifice 5. Diaphragm 6. Main orifice 7. Equalizing orifice 32U970.10 Coil voltage disconnected (open): When the voltage to the coil (2) is disconnected, the pilot orifice (4) is open. As the pilot orifice is larger than the equalizing orifice (7), the across the diaphragm (5) drops and therefore it is lifted clear of the main orifice (6). The valve will be open for as long as the minimum differential across the valve is maintained, and for as long as the voltage to the coil is disconnected. Coil voltage connected (closed): When voltage is applied to the coil, the valve plate (3) is pressed down against the pilot orifice (4). The across the diaphragm (5) is built up via the equalizing orifice (7). The diaphragm closes the main orifice (6) as soon as the across the diaphragm is equivalent to the inlet. The valve will be closed for as long as there is voltage to the coil. DCS (rja) 2016.11 IC.PD.200.N8.02 6