ELECTRICAL POWER, EXTERNAL - SERVICING

Similar documents
PARKING - MAINTENANCE PRACTICES

PARKING - MAINTENANCE PRACTICES

Bombardier Challenger Auxiliary Power Unit

Canadair Regional Jet 100/200 - Auxiliary Power Unit

TOWING - MAINTENANCE PRACTICES. Lockpins. Installation of the Air Driven Generator (ADG) Lockpin

Bombardier Challenger Hydraulic System

canaaair chaiiencjer

Canadair Regional Jet 100/200 - Fuel System

Dash8 - Q400 - Pneumatics

TOWING - MAINTENANCE PRACTICES

BD 700 AIRCRAFT MAINTENANCE MANUAL PART II GRAVITY REFUELING - SERVICING

CHAPTER 4 ---AUXILIARY POWER UNIT

Dornier 328Jet - Pneumatic

Falcon 50 AIRCRAFT MAINTENANCE MANUAL

canadair chzflleriqer OPERATING MANUAL PSP 601A-6 SECTION 5 AUXILIARY POWER UNIT (APU)

PRESSURE REFUELING - SERVICING

CHAPTER FUEL SYSTEM

CHAPTER 4 ---AUXILIARY POWER UNIT

TOWING MAINTENANCE PRACTICES. A. Towing Aircraft (Figure 201 and Figure 202) Cord, headset extension GSE Ref. No

SECTION 5 AUXILIARY POWER UNIT (APU) TABLE OF CONTENTS LIST OF ILLUSTRATIONS. Title

CHAPTER 6 ELECTRICAL SYSTEMS

This chapter contains information on DC Generation, External Power, and Electrical Load Distribution.

Bombardier Global Express - Hydraulics

E230 Aircraft Systems

Dash8-200/300 - Auxiliary Power Unit APU CONTROLS AND INDICATORS. Page 1

CHAPTER ELECTRICAL

FINAL EXAM. 3. Name the items on the control shift in the unmodified aircraft (non ASC-36).

GRAVITY REFUELING - SERVICING

B777. Electrical DO NOT USE FOR FLIGHT

AUXILIARY POWER UNIT. Table of Contents. May 06/2005 Flight Crew Operating Manual Volume 2 REV 2 CSP REV 2

24-00 ELECTRICAL POWER

PILATUS AIRCRAFT LTD. CH-6371 STANS, SWITZERLAND SERVICE BULLETIN SERVICE BULLETIN NO: REF NO: 184 MODIFICATION NO: ATA CHAPTER: 32

B737 NG APU REMOVAL / INSTALLATION

B757 AMM - DC GENERATION - ADJUSTMENT/TEST

CHAPTER HYDRAULIC POWER LIST OF ILLUSTRATIONS

canadair chaifenqer 14-CONTENTS Page 1 Feb 12/88 TABLE OF CONTENTS Subject Page GENERAL ICE DETECTION

CHAPTER 09 TOWING AND TAXIING LIST OF EFFECTIVE PAGES

FORM: 2391 DRAWING NO: ICA-560XL Cessna Aircraft Company P.O Box 7704 WICHITA, KS 67277

1. Aircraft General (0 Hours 39 minutes) 2. Doors (0 Hours 33 minutes) 3. EFIS (2 Hours 55 minutes) 4. Exterior Lighting (0 Hours 24 minutes)

B737 NG APU REMOVAL / INSTALLATION

FUEL SYSTEM REPLENISHING. NOTE: For calculation of fuel weights refer to Chapter 28. British Canadian American Specific Gravity

SECTION 2-05 ELECTRICAL

AFTER PF LANDING PARKING PNF SECURING THE A/C A320

David s Flight Simulator Operations Manual

CHAPTER ICE AND RAIN PROTECTION SYSTEM

canadair chsfflencjibr

Aircraft Handling Ground Connections

We have had a request for instructions on how to replace the 50 AMP CR relay in the A/C electrical box with the upgraded 70 AMP relay.

24 ELECTRICAL DC ELECTRICAL SYSTEM DESCRIPTION

CIRRUS AIRPLANE MAINTENANCE MANUAL

ATA 49 AUXILIARY POWER UNIT

UNITED STATES ARMY AVIATION CENTER FORT RUCKER, ALABAMA. May 2008

AIRCRAFT SYSTEMS FUEL

SECTION IV ELECTRICAL & LIGHTING

AUXILIARY POWER UNIT TABLE OF CONTENTS CHAPTER 5

Chapter 24. Electrical Power

General. APU Control System. APU Door System

FUEL MODEL 750 BAGGAGE COMPARTMENT SMOKE DETECTION

Chapter 1 Aircraft Electrical System

Chapter 24. Electrical Power

DASSAULT AVIATION Proprietary Data

UL Power UL350 Series Engine Installation. Section # 7. Battery & Air Oil Separator Installation

Cessna Citation XLS - Electrical

(PTP) GSS TEMPORARY INSTALLATION

Elegance Electrician s Installation Guide

ARIANA AFGHAN AIRLINES MPD Tally Sheet - Routine Jobs

Full Load Amps Model Number List 1.52/ / / / / /1.3 4/2 3.6/1.8 4/2 4.4/ / / /2.8 2.

DOORS Table of Contents REV 3, May 03/05 CHAPTER DOORS. INTRODUCTION Introduction System Circuit Breakers

Preservation. A.1. Preservation for a Period of up to 30 Days. Pág. 2. Memoria ** ON A/C , , TASK

GIV MEMORY FLASH CARDS OCT09

ROTORCRAFT FLIGHT MANUAL SUPPLEMENT for AS350 Series Helicopter. Registration Number: _. Serial Number: -----

PC-6 SERVICE BULLETIN NO: 180 REF NO: 180 MODIFICATION NO: N/A ATA CHAPTER: 27. All PC-6 aircraft. None.

SERVICE BULLETIN THIS BULLETIN IS FAA APPROVED FOR ENGINEERING DESIGN

AIRCRAFT SYSTEMS PNEUMATIC

Model No. SB1B-14 Linear Standby Regulator. B & C Specialty Products P.O. Box B Newton, KS (316)

POWER ON CHECK LIST COCKPIT PREPARATION

SD3-60 AIRCRAFT MAINTENANCE MANUAL SUPPLY ON GROUND DESCRIPTION & OPERATION

AVIATION UNIT AND AVIATION INTERMEDIATE TROUBLESHOOTING MANUAL CH-47D HELICOPTER

Since then, products have been introduced and expanded to include:

INSTALLATION INSTRUCTIONS

ATA 24 ELECTRICAL POWER

DASSAULT FALCON 900EX EASY SYSTEMS SUMMARY

Freedom egen System End-of- Line Functional Checklist

AG-MI C-EN Fuel Pump Relay

(PTP) ECU TEMPORARY INSTALLATION

A AMM - KRUEGER FLAP ACTUATOR - REMOVAL/INSTALLATION

Bucket Harness. Installation Instructions. for Electric Club Car Precedent

AIRCRAFT SYSTEMS HYDRAULIC

WARNING OPERATION OF AN ENGINE WITH A RESTRICTED OIL PASSAGE CAN CAUSE LOSS OF LUBRICATION AND SUBSEQUENT ENGINE FAILURE.

Lab # 6 Work Orders, Vehicle Identification, Fuses, and Volt Drop

CHAPTER 22 AUTOPILOT

AG-SB B-EN Clamp water hose kit

Electrical System B-17 Technical Session for Flight Engineers

COMPACT BUSWAY 40 & 60 AMP HOUSING

THS ACTUATOR VALVE BLOCKS - ADJUSMENT/TEST

NATEF Hands-On Competency Checklist A5 Auto Brakes

Service Bulletin No: Ref No: 170 Modification No: EC ATA Chapter: 53

1. INTRODUCTION AND SYSTEM DESCRIPTION BLOCK DIAGRAM GENERAL INFORMATION GLOSSARY... 7

Rotary Speed Brake Actuation System ICA Supplement

Service Bulletin No: Ref No: 105 Modification No: INSPECTION ATA Chapter: 32

Transcription:

ELECTRICAL POWER, EXTERNAL - SERVICING TASK 861 801 1. Connect and Energize External AC Power A. Reference Information TASK 10 10 01 867 801 TASK 861 802 TASK 24 00 00 861 801 Grounding of the Aircraft Remove External AC Power Connect Electrical Power to the Aircraft B. Tools and Equipment GSE 24 40 01 Unit, Ground Power AC (480V/60HZ) Refer to the Illustrated Tool and Equipment Manual to make sure that you use the correct equipment configuration. C. Job Set Up WARNING: GROUND THE AIRCRAFT BEFORE YOU CONNECT THE EXTERNAL ELECTRICAL POWER. YOU CAN CAUSE INJURIES TO PERSONS AND DAMAGE TO THE EQUIPMENT. (1) Ground the aircraft (TASK 10 10 01 867 801). (2) Open the access door that follows: ACCESS 122BR Door, AC Ground Power Connection D. Procedure Refer to Figure 301. (1) Connect the ground power unit to the ac receptacle. (2) Set the ground power unit to 115 volts at 400 hertz. (3) Start the ground power unit. Page 301 Mar 13/2009

Make sure you use the correct electrical power source necessary for the specified maintenance task (TASK 24 00 00 861 801). (4) Put the BATT MASTER switch to the ON position. (5) On the ELECTRICAL POWER control panel, make sure that the AVAIL part of the EXT POWER AC switch/light comes on (green). (6) Push the EXT POWER AC switch/light. (7) Make sure that the IN USE part of the EXT POWER AC switch/light comes on (white). (8) Make sure that the AVAIL part of the EXT POWER AC switch/light goes off. E. Close Out (1) Remove all tools, equipment, and unwanted materials from the work area. (2) Remove the external ac power (TASK 861 802). Page 302 Mar 13/2009

LMM1200073_001 Connection of External AC Power Servicing Figure 301 Page 303

TASK 861 802 2. Remove External AC Power A. Reference Information CL 604 AIRCRAFT MAINTENANCE MANUAL PART II TASK 861 801 TASK 24 00 00 861 802 Connect and Energize External AC Power Remove Electrical Power from the Aircraft B. Tools and Equipment GSE 24 40 01 Unit, Ground Power AC (480V/60HZ) Refer to the Illustrated Tool and Equipment Manual to make sure that you use the correct equipment configuration. C. Job Set Up (1) Make sure that the aircraft is in the same configuration as for connection of external ac power. Make sure you use the correct electrical power source necessary for the specified maintenance task (TASK 24 00 00 861 802). D. Procedure Refer to Figure 301. (1) On the ELECTRICAL POWER control panel installed in the flight compartment, put the BATT MASTER switch to the OFF position. (2) Push the EXT POWER AC switch/light. (3) Make sure that the IN USE part of the EXT POWER AC switch/light goes off. (4) Make sure that the AVAIL part of the EXT POWER AC switch/light comes on (green). (5) Stop the ground power unit. Make sure you use the correct electrical power source necessary for the specified maintenance task (TASK 24 00 00 861 802) (6) Disconnect the ground power unit from the ac receptacle. Page 304 Mar 13/2009

E. Close Out (1) Remove all tools, equipment, and unwanted materials from the work area. (2) Close the access door that follows: ACCESS 122BR Door, AC Ground Power Connection Page 305 Mar 13/2009

TASK 861 803 3. Connect and Energize External DC Power A. Reference Information CL 604 AIRCRAFT MAINTENANCE MANUAL PART II TASK 10 10 01 867 801 TASK 861 804 TASK 24 00 00 861 801 TASK 24 00 00 910 801 Grounding of the Aircraft Remove External DC Power Connect Electrical Power to the Aircraft Electrical/Electronic Safety Precautions B. Tools and Equipment GSE 24 40 02 Unit, Ground Power DC Refer to the Illustrated Tool and Equipment Manual to make sure that you use the correct equipment configuration. C. Job Set Up WARNING: GROUND THE AIRCRAFT BEFORE YOU CONNECT THE EXTERNAL ELECTRICAL POWER. YOU CAN CAUSE INJURIES TO PERSONS AND DAMAGE TO THE EQUIPMENT. (1) Ground the aircraft (TASK 10 10 01 867 801). WARNING: OBEY ALL THE SAFETY PRECAUTIONS WHEN YOU DO MAINTENANCE ON OR NEAR ELECTRICAL/ELECTRONIC EQUIPMENT. IF YOU DO NOT OBEY THE SAFETY PRECAUTIONS, YOU CAN CAUSE INJURY TO PERSONS AND DAMAGE TO THE EQUIPMENT. (2) Obey all the electrical/electronic safety precautions (TASK 24 00 00 910 801). (3) Open the access door that follows: ACCESS 312AR Door, External DC Ground Power Connection Page 306

D. Procedure Refer to Figure 302. (1) Connect the ground power unit to the dc receptacle. (2) Set the ground power unit to 28 volts. (3) Start the ground power unit. (4) On the ELECTRICAL POWER control panel, make sure that the EXT POWER DC IN USE light comes on (white). Make sure you use the correct electrical power source necessary for the specified maintenance task (TASK 24 00 00 861 801) (5) Set the BATT MASTER switch to ON. (6) On the EICAS DC ELECTRICAL synoptic page, make sure that the APU BATT DIR BUS is powered by the EXT DC box. E. Close Out (1) Remove all tools, equipment, and unwanted materials from the work area. (2) When necessary, remove the external dc power (TASK 861 804). Page 307

LMM1200073_002 Connection of External DC Power Servicing Figure 302 Page 308

TASK 861 804 4. Remove External DC Power A. Reference Information CL 604 AIRCRAFT MAINTENANCE MANUAL PART II TASK 24 00 00 861 802 TASK 24 00 00 910 801 Remove Electrical Power from the Aircraft Electrical/Electronic Safety Precautions B. Tools and Equipment GSE 24 40 02 Unit, Ground Power DC Refer to the Illustrated Tool and Equipment Manual to make sure that you use the correct equipment configuration. C. Job Set Up (1) Make sure that the aircraft is in the same configuration as for connection of external dc power. WARNING: OBEY ALL THE SAFETY PRECAUTIONS WHEN YOU DO MAINTENANCE ON OR NEAR ELECTRICAL/ELECTRONIC EQUIPMENT. IF YOU DO NOT OBEY THE SAFETY PRECAUTIONS, YOU CAN CAUSE INJURY TO PERSONS AND DAMAGE TO THE EQUIPMENT. (2) Obey all the electrical/electronic safety precautions (TASK 24 00 00 910 801). D. Procedure Refer to Figure 302. (1) Set the BATT MASTER switch to OFF. (2) Stop the ground power unit. (3) Disconnect the ground power unit from the dc receptacle. E. Close Out (1) Remove all tools, equipment, and unwanted materials from the work area. Page 309

(2) Close the access door that follows: ACCESS 312AR Door, External DC Ground Power Connection Page 310