Analysis of Grid Connected Solar Farm in ETAP Software

Similar documents
Anupam *1, Prof. S.U Kulkarni 2 1 ABSTRACT I. INTRODUCTION II. MODELLING OF WIND SPEED

HOMER OPTIMIZATION BASED SOLAR WIND HYBRID SYSTEM 1 Supriya A. Barge, 2 Prof. D.B. Pawar,

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

Design and Simulation of Grid Connected PV System

Design and Control of Hybrid Power System for Stand-Alone Applications

Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition

Behaviour of battery energy storage system with PV

Statcom Operation for Wind Power Generator with Improved Transient Stability

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

IJRASET 2013: All Rights are Reserved

Implementation SVC and TCSC to Improvement the Efficacy of Diyala Electric Network (132 kv).

Grid Stability Analysis for High Penetration Solar Photovoltaics

TRANSMISSION LOSS MINIMIZATION USING ADVANCED UNIFIED POWER FLOW CONTROLLER (UPFC)

Power Flow Simulation of a 6-Bus Wind Connected System and Voltage Stability Analysis by Using STATCOM

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

BIDIRECTIONAL DC-DC CONVERTER FOR INTEGRATION OF BATTERY ENERGY STORAGE SYSTEM WITH DC GRID

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

By: Ibrahim Anwar Ibrahim Ihsan Abd Alfattah Omareya. The supervisor: Dr. Maher Khammash

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

A Review on Grid Connected 100 kw Roof Top Solar Plant

Design of Active and Reactive Power Control of Grid Tied Photovoltaics

Hardware Implementation of Power Generation using Attic Type Internally Braced Air Exhauster for Industrial Application

Power Management with Solar PV in Grid-connected and Stand-alone Modes

Targeted Application of STATCOM Technology in the Distribution Zone

Electric Power System Under-Voltage Load Shedding Protection Can Become a Trap

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

GRID CONNECTED SOLAR WIND HYBRID POWER BASED ON IOT

International Journal of Advance Research in Engineering, Science & Technology

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

Design of Net Meter for Off Grid Microgrid

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

Modelling of PV Array with MPP Tracking & Boost DC-DC Converter

Figure 1 I-V characteristics of PV cells. Meenakshi Dixit, Dr. A. A. Shinde IJSRE Volume 3 Issue 12 December 2015 Page 4687

Performance Analysis of Transient Stability on a Power System Network

Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid

Hybrid Three-Port DC DC Converter for PV-FC Systems

Review on Grid-Connected Hybrid DFIG Based Wind and PV System

DESIGN AND IMPLEMENTATION OF SMART NANOGRID

Battery Energy Storage System addressing the Power Quality Issue in Grid Connected Wind Energy Conversion System 9/15/2017 1

Implementation of FC-TCR for Reactive Power Control

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

Glossary. * Credit for glossary starter: Florida Solar Energy Center. August 2015 PV Installer's Course: Glossary 1

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Modelling and Analysis of Thyristor Controlled Series Capacitor using Matlab/Simulink

Simulation and design of wind-pv hybrid power generation systems

The Effect Of Distributed Generation On Voltage Profile and Electrical Power Losses Muhammad Waqas 1, Zmarrak Wali Khan 2

Stabilization of Solar-Wind Hybrid Power System by Using SMES

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

PLUGGING BRAKING FOR ELECTRIC VEHICLES POWERED BY DC MOTOR

Modeling and Analysis of Vehicle with Wind-solar Photovoltaic Hybrid Generating System Zhi-jun Guo 1, a, Xiang-yu Kang 1, b

A STUDY ON ENERGY MANAGEMENT SYSTEM FOR STABLE OPERATION OF ISOLATED MICROGRID

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Electric Vehicles Coordinated vs Uncoordinated Charging Impacts on Distribution Systems Performance

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

Single Stage Grid Interactive Photovoltaic System

DYNAMIC BRAKES FOR DC MOTOR FED ELECTRIC VEHICLES

Design and Implementation of Non-Isolated Three- Port DC/DC Converter for Stand-Alone Renewable Power System Applications

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

Simulation of real and reactive power flow Assessment with UPFC connected to a Single/double transmission line

Modeling and Comparison of Dynamics of AC and DC Coupled Remote Hybrid Power Systems

A Study of Suitable Bi-Directional DC-DC Converter Topology Essential For Battery Charge Regulation In Photovoltaic Applications

Performance Analysis of Transmission Line system under Unsymmetrical Faults with UPFC

Design Modeling and Simulation of Supervisor Control for Hybrid Power System

DESIGN AND ANALYSIS OF CONVERTER FED BRUSHLESS DC (BLDC) MOTOR

Optimal Sizing, Modeling, and Design of a Supervisory Controller of a Stand-Alone Hybrid Energy System

Co-Ordination Control and Analysis of Wind/Fuel Cell based Hybrid Micro-Grid using MATLAB/Simulink in Grid Connected Mode

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Modelling and Simulation of DFIG based wind energy system

INTELLIGENT DC MICROGRID WITH SMART GRID COMMUNICATIONS: CONTROL STRATEGY CONSIDERATION AND DESIGN

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

A Novel GUI Modeled Fuzzy Logic Controller for a Solar Powered Energy Utilization Scheme

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Modeling and Simulation of Multi-input Bi-directional Boost Converter for Renewable Energy Applications using MatLab/Simulink

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

A SIMPLE CONTROL TECHNIQUE FOR UNIFIED POWER FLOW CONTROLLER (UPFC)

Simulation Analysis of Closed Loop Dual Inductor Current-Fed Push-Pull Converter by using Soft Switching

Performance Analysis of 40 KW Solar Photovoltaic System at DTU

Hybrid Energy Powered Water Pumping System

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

Field Verification and Data Analysis of High PV Penetration Impacts on Distribution Systems

Design of Three Input Buck-Boost DC-DC Converter with Constant input voltage and Variable duty ratio using MATLAB/Simulink

Battery-Ultracapacitor based Hybrid Energy System for Standalone power supply and Hybrid Electric Vehicles - Part I: Simulation and Economic Analysis

Design and Development of Bidirectional DC-DC Converter using coupled inductor with a battery SOC indication

Enhancement of Power System Stability Using Thyristor Controlled Series Compensator (TCSC)

PLC Based ON-Grid System for Home Appliances

Available online at ScienceDirect. Energy Procedia 36 (2013 )

Hybrid Solar Panel Fuel Cell Power Plant

Impact of Reflectors on Solar Energy Systems

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Stability Study of Grid Connected to Multiple Speed Wind Farms with and without FACTS Integration

Control Scheme for Grid Connected WECS Using SEIG

Design of an off Grid Photovoltaic system for New Office Buildings

Control and Implementation of Solar Photovoltaic-Fuel Cell with Dual Ultra Capacitor Hybrid System

Multi-Port DC-DC Converter for Grid Integration of Photo Voltaic Systems through Storage Systems with High Step-Up Ratio

A.Arun 1, M.Porkodi 2 1 PG student, 2 Associate Professor. Department of Electrical Engineering, Sona College of Technology, Salem, India

Development of a Stand-alone Solar

FAULT ANALYSIS FOR VOLTAGE SOURCE INVERTER DRIVEN INDUCTION MOTOR DRIVE

Grid code Compliance and Renewable Energy Projects. Mick Barlow, Business Development Director, S&C Electric, United Kingdom

A Novel Hybrid PV/Wind/Battery based Generation System for Grid Integration

Transcription:

ABSTRACT 2017 IJSRSET Volume 3 Issue 3 Print ISSN: 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Analysis of Grid Connected Solar Farm in ETAP Software Komal B. Patil, Prof. R. S. Ambekar * 1 Electrical Department, Bharati Vidyapeeth Deemed University, College of Engineering, Pune, Maharashtra, India Komalp.27@gmail.com 1 2 Electrical Department, Bharati Vidyapeeth Deemed University, College of Engineering, Pune, Maharashtra, India rsambekar@bvucoep.edu.in 2 In today s day to day life the energy requirement growth will increasing rapidly. The use of renewable energy is important to provide rapid increased energy demand. Solar energy provides free energy from sun which is pollution free, clean and maintenance free energy. This paper aims to analyse the performance analysis of grid connected solar farm. This analysis consists of load flow analysis, active power flow at different irradiance, reactive power analysis and short circuit analysis on impact of 1-ϕ and 3-ϕ. To accomplish this proposed system modelling is done in ETAP (Electrical Transient Analyzer Program) software. Keywords:ETAP (Electrical Transient Analyzer Program), load flow analysis, solar farm, short circuit analysis. I. INTRODUCTION Over the past few years, the requirement for renewable energy resources has increased rapidly due to the decreasing fossil fuels and its adverse impacts on environment. From different types of renewable energy resources the solar energy gives more cleanly and pollution free energy [1]. India is most promising country for the development of solar power systems. It is because most part of the country includes high number of sunny days and daily irradiance. Also it provides high efficiency, better reliability and low cost for generating electrical energy [1]-[2]. The main objective of this paper was to analyze the performance of the grid connected solar farm. The analysis includes load flow analysis, active power flow at different irradiance and cable lengths, reactive power analysis at grid side of the solar farm and short circuit analysis. There are different types of the analyzer program which are helps in analysis of solar farm including solar panels, for providing better performance of the system. The performance analysis of solar farm model was simulated in ETAP (Electrical Transient Analyzer Program) software for appropriate operation. The overview of solar farm was simulated in ETAP as a single line diagram. The solar farm included 20 solar panels each of 315 W per panel connected 30*40 in series and parallel respectively constituting total capacity of each solar panel was 378 KW. The overall capacity of solar farm was 7560 KW; the system was internally connected through cables. The solar farm was monitored for analysis on 132 KV voltage level at bus 1. Adaptive Newton Raphson method was implemented for load flow analysis at different irradiance. II. AN OVERVIEW OF THE SOLAR FARM FOR ANALYSIS Solar farm was designed included 4 networks with total capacity of 7560 KW. All networks comprise 1630 KW and each solar panels capacity is 378 KW. Grid (U1) operates at 132 KV bus voltage connected in series with transformer (T1) with capacity of 50 MVA. Further the networks 1, 2, 3 and 4 are connected in parallel through step-up transformer T2, T3, T4 and T5 respectively with capacity of 2.5 MVA at 33 KV. The solar panels are connected to these step-up transformers at 1/33 KV. IJSRSET1733169 20 June 2017 Accepted :30 June 2017 May-June-2017[(2)3: 633-637] 633

Figure 3. Equivalent circuit of solar array Figure 1. Single Line Diagram of the Solar Farm III. SOLAR SYSTEM Solar farms are designed using photovoltaic technology for conversion of electricity directly from sunlight by using solar cells. The number of solar cells electrically connected in series and parallel to form a solar module and number of solar modules connected together to form an array. This structure is useful for increasing production of electric energy [3]. The photovoltaic systems are of two type s namely stand-alone system and grid connected system [2]. This paper is focuses on the grid connected solar system and the solar cell was made by polycrystalline silicon. Grid connected systems are directly connected to the utility grid and there is no need to use of battery storage. In this system the generated electric energy is directly convert to the alternating current by use of inverter and supplied to utility grid [5]. Utility grid supplies reactive power to the system, so the compensation of the reactive power is necessary to prevent voltage profile. Figure 4. Grid Connected Solar System IV. RESULTS AND DISCUSSION Figure 2. Equivalent circuit of solar cell The equivalent circuit of solar cell is shown in fig. 2. Where Iph is current source, Rsh is shunt resistance and Rs is series resistance. The Rsh value is very large and Rs value is small, so for simplification these values are neglected. K presents Boltzmann constant, N is represents diode ideality factor and T represents the cell temperature. The equivalent circuit of solar array is shown in fig. 3. The load current equation is shown below [4]. [ ] (1) a) Load flow analysis In ETAP, load flow analysis was performed power flow analysis for individual networks and voltage drop calculations with accurate and reliable results. In this paper adaptive Newton-Raphson method was executed for the load flow analysis. Active power flow at grid was around 6448 KW and for individual network active power flow was 1623 KW. Table I Active power flow Network Actual (KW) Simulation (KW) Total (At Grid) 7560 6448 Network 1 1890 1623 634

Network 2 1890 1623 Network 3 1890 1623 Network 4 1890 1623 Figure 6.Active power curve at different irradiations The active power curve shown in Fig.6 clearly shows the power output of the solar farm is directly proportional to the incident irradiance of the sun. c) Reactive power analysis Figure 5.Active power flow b) Active power flow at different irradiance The output of the solar module is directly proportional to the incident irradiance. The irradiations are varies depending on the position of the sun and weather throughout the day. The power output changes at different irradiations as per the position of sun in the sky. The results are shown in table 2 below. The reactive power is very important factor in performance of the system. In the grid connected system the reactive power must be balanced to prevent voltage problems. The load flow analysis shows the absorption of reactive power from the grid as shown in above Fig. 7. The total reactive power at the grid is 1.2 Mvar, and each network consume 0.2 Mvar. The negative sign shows that the grid supplies the power towards opposite direction. Table II Active power at different irradiance Irradiation Active power output (W/m2) (KW) 147 881 237 1435 660 3957 854 5054 892 5265 912 5375 937 5513 950 5584 The simulated analysis shows that the active power output of the solar plant varies with changes in incident irradiance. The analysis shows that higher incident irradiance gives higher active power as shown in table 2. Figure 7.Reactive power drawn from the grid For balancing the output and to improve efficiency of the solar farm, the compensation of reactive power is very much important. To overcome this capacitor bank was implemented in the system. Capacitor bank was designed with appropriate parameters to improve 635

stability with reducing the reactive power drawn from the grid. Figure 9.Voltage at Bus 1 during 3- ϕ short circuit fault Firstly start with 3- ϕ fault, after the occurrence of the 3- ϕ fault the voltage was dropped to almost 0 kv and after clearing the fault the system will return back to the100% normal operating voltage with the clearing time 0.5 sec. Second the 1- ϕ line-ground fault, after occurrence of this fault the system voltage recovered quickly under this analysis. Figure 8.Reactive power compensation using capacitor bank As shown in Fig. 8 the compensation of reactive power is successfully done using capacitor bank at Bus 1 with 132 kv voltage level. After using the capacitor bank the total reactive power drawn from the grid was 0.08 Mvar. Using the proper sizing of the capacitor bank the stability and efficiency of overall system will be improved. d) Short circuit analysis The ETAP software was considered for short circuit analysis in solar farm. The main factor of the short circuit analysis is to determine the ability of system to return back to the normal state after recovery of fault. In the solar farm the analysis was done for the short circuit faults which are single line-ground fault and three phase short circuit fault. This analysis was performed at the main Bus 1 near to the grid. In the analysis the total simulation time was consider 10 sec for study the impact of both faults and clearing time of the faults. The fault occurred at 2 sec and cleared at 2.5 sec. Figure 10.Voltage at Bus 1 during 1- ϕ line-ground fault V. CONCLUSION In this paper analysis were carried out includes load flow analysis, reactive power analysis and short circuit analysis. The active power flow at different irradiance was analyzed. The reactive power analysis result shows that high amount of reactive power absorption from the grid. Hence compensation devices are required for reactive power compensation like capacitor bank, SVC s and STATCOM. In this analysis capacitor bank was implemented to compensate reactive power which is cheaper than other devices. The short circuit analysis was used to determine system ability to recover from the fault. The 3- ϕ fault has more severe impact than 1- ϕ line-ground fault on the system. 636

VI. REFERENCES [1] Nisha Sharma, Deepak Dalal, Efficiency and Result Analysis of 50Kw Grid Connected PV System Using MATLAB/SIMULINK, IJAREEIE, Vol. 4, Issue 10, October 2015. [2] D. B. Raut& A. Bhattrai, Performance Analysis of Grid Connected Solar PV System Using Matlab/Simulink, Rentech Symposium Compendium, Volume 3, September 2013. [3] Ram Krishan, Yog Raj Sood and B.Uday Kumar, The Simulation and Design for Analysis of Photovoltaic System Based on MATLAB, Electrical Engineering Department National Institute of Technology Hamirpur (H.P.) India, IEEE Dec. 2013. [4] Md. Aminul Islam, Adel Merabet, RachidBeguenane and Hussein Ibrahim, Modeling Solar Photovoltaic Cell and Simulated Performance Analysis of a 250W PV Module, 2013 IEEE Electrical Power & Energy Conferenc (EPEC), 2013. [5] S.M.A.Faisal, Model of Grid Connected Photovoltaic System Using MATLAB/SIMULINK, Department of Electrical & Electronics Engineering Ahsanullah University of Science and Technology Dhaka, Bangladesh. 637