INSTRUCTION AND USE MANUAL

Similar documents
UNIT FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET

CONTROL AND PROTECTION PANEL FOR TRACTOR-PUMP CTR-087/0N THE TRACTOR/PUMP IS STOPPED WHEN THERE ARE ANOMALIES (VIA ELECTROMAGNET) CONCERNING:

PANEL FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET

PANEL FOR CONTROL AND PROTECTION OF IRRIGATION MOTOR PUMPSET

CONTROL UNITS FOR IRRIGATION MOTOR PUMPS AND PUMP WATER PRESSURE CONTROL

Fire Fighting Diesel Pump Control Panel in Compliance with EN Standard User Manual

Type CIM-131. ELCOS SRL - Parma - GB - CIM-131 1

FIREPAK-E21 & FIREPAK-ED21

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

DKG-114 MANUAL AND REMOTE START UNIT

Language specific user manuals are available on

Multi-Mover Charger for model L25

Mod: KLD6-12/35XLAS-N

Flight Systems. Replacement for KASSEC DESCRIPTION

ENGINE PROTECTION BOARD PDM1

DIESEL-EN - User Manual

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

SPEEDRIVE INSTRUCTIONS MANUAL

Instruction Manual. Q Series 2 Motor Control Modules - OEM

STANDARD OWNER S MANUAL

USER INSTRUCTIONS FOR SLIDING DOORS

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

PowerView PV380-R2 Mechanical Configuration

User Manual. Charger for LTO Batteries. User Manual. Language specific user manuals are available on

Model H30 Operation Manual

PRODUCT SPECIFICATION. Stack Lights. Series.

PSM72H Push-Button Start Module

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

IGLOO IGLOO EASY INSTRUCTION MANUAL

EC225 Power Control System

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

Actuators. Building Technologies Division

EC400 Power Control System

SIZING OF SOLAR GENERATOR

DIESEL Engine Fire Pump Controllers Features

GeniSys 24V. Model Advanced 24 Vdc Burner Control. Description / Applications

AUE-AUD-AU2E AU2D-AUED

TECHNICAL SPECIFICATIONS

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

Two Channel Remote Shutdown Device

SDM72 Start on Demand Modules

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual

Tina 4A Connection block

ECONOMISER SERIES E2T USER MANUAL

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

400W Solar Charger Maximum Power Point Tracker

DEEP SEA ELECTRONICS PLC

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

FMC-1/2 Tina Muting unit

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

with lcd display 12-42v

EC200 ELECTRONIC CONTROL SYSTEM

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

CONTROL, PROTECTION AND VISUALIZATION ELECTRONIC MANUAL CEN- TRALITE FOR GENERATING SETS CMD2.0

REC-11+ REMOTE RECEIVER UNIT

INTELLITROL. scully. Scully s Intellitrol System. Intellitrol is a state of the art microprocessor based system that provides:

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

For air dampers and control valves of oil or gas burners

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

Section 3 Technical Information

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

Tina 11A Connection block

User Manual. 1. Introduction

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

Language specific user manuals are available on

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

.3 Section Concrete Forms and Accessories: Installation of Anchor Devices, Setting Templates

USE AND INSTALLATION HANDBOOK

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

MCD Pump Application Module

DEEP SEA ELECTRONICS PLC

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

FIRE CONTROL

INSTALL GUIDE AKX-IDS(RS)-BZ1B-[ADS-BZ1]-EN

General Description. Product Specification. Document Digital Temperature Interlock

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

EC400 / EC450 series Power Control System

E Series CE Approved Intermittent Pilot Ignition Control

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES

Service Manual for Battery Control Center

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

GENSET CONTROL MODULE A121A / A241A

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

User Manual. Solar Charge Controller 3KW

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

Compact System NRGS 11-2 NRGS Original Installation Instructions English

CX-SERIES ADVANCED BATTERY CHARGER

R & D SPECIALTIES ROTROL I USER'S MANUAL

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

Transcription:

CONTROL UNITS FOR ENGINE CONTROL AND PROTECTION TYPE CEP-090 INSTRUCTION AND USE MANUAL It is equipped with display to show the INSTRUMENTS: - hour-meter - fuel level indicator - tachometer - battery voltmeter } Automatic supervision of faults with messages on the display Texts in 6 languages: Italian, English, French, German, Spanish and Portuguese Preheating glow plugs management To be requested from the manufacturer 100 62 182 Ø6,5 210 172 DIMENSIONS Fixing system With two or On request three with vibration clamps dampers fitted on the top part of the control unit 85,50 33 135,50 96 ELCOS SRL - Parma - GB - CEP-090 1

Display Hold down to verify the led test. The engine protection devices are active. Stopping due to insufficient engine oil pressure Stopping due to lack of battery Charging (belt breakage). Stopping due to high engine temperature. BRIEF INSTRUCTIONS IGNITION KEY - REST - MANUAL STOP - RESET AUT. - CONTROL PANEL SUPPLY - GLOW PLUGS Press to select the displayed function, each time it is pressed, the instrument indicated by the display changes. Utilize in programming. FUEL INDICATOR stops with NO FUEL. Possibility of disabling the stop with rheostat float. Flashing light FUEL RESERVE (10% not adjustable) indicator always on NO FUEL (1% not adjustable). With rheostat float NO FUEL the intervention occurs when the float contact closes to earth. - STARTING THE ENGINE INSTRUMENTS TACHOMETER Displays the number of engine revs up to 8500 rpm. TOTAL HOUR-METER Displays five digits and a maximum reading of 59999 (hours and minutes). FUEL LEVEL GAUGE Displays the percentage of fuel present in the tank 1BATTERY VOLTMETER For voltages ranging between 9 and 38 Volt. 2 START Battery voltage supply Voltage supply Circuit loading with key at zero Maximum Consumption Tachometer Instruments precision: battery voltmeter, fuel level Max. load of the output: stopping (yellow) general alarm (red/green) preheating (blue/orange) starting (black) Degree of protection: Box front Rear Connector TECHNICAL DATA 12 Vdc 24 Vdc 8 32V 2,5mA a 12V 2mA a 24V 230 ma a 12V 180 ma a 24V Max 4000 RPM precision ± 10 RPM 1% 3A 3A 3A 40A IP54 IP23 IP20 Temperature range -20 +60 C Weight 950 g ELCOS SRL - Parma - GB - CEP-090

OPERATION TWIN FUNCTION INDICATORS OIL AND BATTERY INDICATORS ON when key is turned to AUT, OFF when the engine is running with correct oil pressure and battery charging. ANOMALY INDICATORS Enabled after the lighting up of the PROTECTIONS ACTIVES, visual indicator, they light up when an anomaly is detected. ENGINE PROTECTIONS The engine protections are enabled after the lighting up with steady light, of the ENGINE PROTECTIONS ACTIVE visual indicator (60 seconds after turning the key to AUT or, in any case, 20 seconds after the start impulse). The protections probe (mounted on the engine) interventions, shown by the relevant visual indicators, stop the engine. They can be divided into two groups: Immediately for: 5 second delay for: -OIL PRESSURE SWITCH - BATTERY CHARGE ALTERNATOR (Broken alternator belt) - OVER-HEATING - FUEL FLOAT THERMOSTAT - NO FUEL (possibility of disabling the stop) RESET Is obtained by turning the start key onto ZERO. STOP The control unit shuts down the engine in two ways: - turning the start key to zero. - protection intervention. The unit adapts to two different stop system: - by working the electromagnet for 20 seconds which pulls the stop lever. - by cutting off power to the solenoid valve shutting off the flow of fuel. EMERGENCY STOP FUNctions on request It can be obtained in all functioning conditions, mounting one or more release-type buttons, is indicated on the display. To connect THE EMERGENCY STOP the connector changes the type of control unit. GENERAL ALARM This can be obtained by externally installing an optical indicator and/or buzzer to be connected to the relevant output. Activated continuously if the protection devices or the fuel reserve alarm intervene. SILENCING THE AUDIBLE ALARM Hold down button. GLOW PLUGS PREHEATING FACTORY-EXCLUDED Activated with key in AUT the display shows the phrase GLOW PLUGS. The duration of the preheating action can be set. PREHEATING Is indicated on the display when the action has ceased START THE. ENGINE ELCOS SRL - Parma - GB - CEP-090 3

ACCESS TO PROGRAMMING MODE. USER PROGRAMMING EXIT FROM PROGRAMMING MODE. Turn the key to Re-position the key to to select USER PROGRAMMING PRESS (5 ) USER PROGRAMMING PRESS TO DISPLAY THE REQUIRED PROGRAMMING LANGUAGE CHOICE LANGUAGE CHOICE. The language set up in the factory is ITALIAN; the languages that can be selected are: ENGLISH - FRENCH - GERMAN - SPANISH and PORTUGUESE. ITALIANO ENGLISH Press to select language Press and wait for PROGRAMMED to be written TACHOMETER ADJUSTMENT Bring the engine to idle at constant known speed for example via a portable tachometer. example 1500 RPM 1500 RPM Press and wait for OK to be written. Press until you get the right indication on the display 4 ELCOS SRL - Parma - GB - CEP-090

FROM 15/54 OF START KEY, USABLE FOR AUXILIARIES WIRING DIAGRAM 3A MAX CONNECTOR 157 WARNING FOR LOADS WITH CUR- RENT ABOVE 3A, A RELAY MUST BE USED FUSE REPLACEMENT THE FUSES ARE INSIDE THE JUNCTION BOX. TO HAVE ACCESS TO THE INSIDE, REMOVE THE SCREWS THAT SECURE THE FRONT AND REPLACE WITH FUSE OF THE SAME VALUE. PRE-EXCITATION GREY IMPORTANT WHEN USING A PREEXCITATION ALTERNATOR OF BATTERY CHARGING HOOK THE DIVERTER TO THE POSITION THAT CORRESPONDS TO THE NOMINAL VOLTAGE OF THE BATTERY (12-24V). DO NOT HOOK WITH OTHER TYPES OF ALTERNATOR OF BATTERY CHARGER. 26/28 CHARGE BATTERY ALTERNATOR: PERMANENTS MAGNETS YELLOW RED YELLOW GREEN 9 11 10 8 7 6 5 4 3 WHITE/RED 3 WHITE/RED GREEN BROWN BROWN ONLY PERMANENT MAGN. + BATTERY WHITE/RED + BATTERY GREEN BROWN 2 WHITE YELLOW 1 2/7 4 LIGHT BLUE BLACK 40A MAX RED BATTERY 3A MAX 41 BLUE/ORANGE RED/GREEN MAX. LOAD 3W INSULATE POSSIBLE CABLES NOT CONNECTED 3A MAX 106 30 50 ORANGE T W ACCESSORIES AVAILABLE ON REQUEST (2/7) ELECTROMAGNET OR SOLENOID VALVE (3) OIL PRESSURE SWITCH (4) THERMOSTAT (16) FUEL FLOAT MOUNTED ON ENGINE (26/28) PERMANENT MAGNETS CHARGE ALTERNATOR OR PRE-EXCITATION (27) BATTERY CHARGE ALTERNATOR REGULATOR (40) STARTING MOTOR (41) BATTERY (106) GLOW PLUGS PREHEATING (157) GENERAL ALARM LIGHT 16 40 ELECTROMAGNET (EXCITED IN STOP MODE): to activate the engine stop lever. SOLENOID (EXCITED IN DRIVE): to close the fuel. STOP SYSTEM SET UP The unit has been designed to control stopping with an solenoid valve. ELCOS SRL - Parma - GB - CEP-090 5

NOTES 6 ELCOS SRL - Parma - GB - CEP-090

NOTICES Only for starting and surveillance of the diesel engine and stops it if there are anomalies in the parts controlled by probes. It has been designed to be installed also on the machine. Warning: adhere closely to the following advice - Always follow the Wiring Diagram on pages 5 when making connections. - All technical interventions must be performed with the engine stationary and terminal 50 of the starter motor disconnected. - Check that the line loading and the consumption of the connected equipment are compatible with the described technical characteristics. - Install in such a way that there is always adequate heat disposal. - Always install under other equipment which produces or spreads heat. - Never disconnect the battery terminals with the engine running. - Never use a battery charger for the emergency start-up; the control unit could be damaged. - In order to safeguard people and equipment, before connecting an external battery charger, disconnect the electrical system terminals from the battery poles. THIS CONTROL UNIT IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING CONDITIONS: - Where the environmental temperature is outside the limits indicated in the Technical Data. - Where the air pressure and temperature variations are so rapid as to produce exceptional condensation. - Where there are high levels of pollution caused by dust, smoke, vapour, salts and corrosive or radioactive particles. - Where there are high levels or heat from radiation caused by the sun, ovens or the like. - Where attacks from mould or small animals are possible. - Where there is the risk of fire or explosions. - Where the control unit can receive strong vibrations or knocks. ELECTROMAGNETIC COMPATIBILITY This control unit functions correctly only if inserted in plants which conform with the CE marking standards; it meets the exemption requirements of the standard EN61326-1 but it cannot be excluded that malfunctions could occur in extreme cases due to particular situations. The installer has the task of checking that the disturbance levels are within the requirements of the standards. CONDUCTION AND MAINTENANCE The following maintenance operations should be performed every week: - check that the indicators function; - check the batteries; - check that the conductors are tight, check the condition of the terminals. UNLESS WE MAKE A WRITTEN DECLARATION STATING THE CONTRARY, THIS CONTROL UNIT IS NOT SUITABLE FOR USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS RESPONSIBLE FOR KEEPING PERSONS OR OTHER LIVING BEINGS ALIVE. YOUR ELECTRICAL TECHNICIAN CAN ASK US ANYTHING ABOUT THIS CONTROL UNIT BY TELEPHONING ONE OF OUR TECHNICIANS ELCOS SRL - Parma - GB - CEP-090 7

ORDERING DATA Type CEP-090 cod. 00210721 ACCESSORIES KIT Pre- wired female type CEP-090 cod. 70804336 kit rods CEP-CEM cod. 40804362 CONFORMITY DECLARATION The company Elcos s.r.l. assumes full responsibility for declaring that control unit: type CEP-090 installed and used in the ways and for the purposes described in the user instruction manual complies with the essential requirements and other relevant provisions laid down by the following directives: - 2004/108/CE related to the electromagnetic compatibility and that repeals the directive 89/336/CEE, - 2011/65/UE on the restriction of the use of certain hazardous substances in electrical and electronic equipment, because it is built and functions in accordance with the harmonized Standards: EN61326-1, EN61326/A1, EN61000-4-2, EN61000-4-4, EN61000-4-6, EN60529. 8 ELCOS SRL - Parma - GB - CEP-090