T F

Similar documents
Industrial Gas Springs

Looking for a gas spring replacement...

Series 16 Gas Springs. Lift, support, damping and adjustment devices

CATALOGUE GAS SPRINGS

Stainless Steel Traction Gas Springs (Pull Type)

Stainless Steel Industrial Gas Springs (Push Type)

Traction Gas Springs GZ-15 to GZ-40 (Pull Type)

Industrial Gas Springs Pull Type

Push Type Gas Springs

Air-Oil Systems, Inc. Gas Springs AGS 15 - AGS 28

Gas Springs AGS 15 - AGS 28

Safety Shock Absorbers SCS33 to SCS64

Installation and Operating Instructions Magnetic Vibrator MR 1

L A N G E L I F T P R O D U C T M A N U A L PRODUCTS THAT LIFT THE WORLD! USAGE & MAINTENANCE GUIDE. a Division of Hevi-Haul International, Ltd.

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

ATV TRACK KIT. Operator s Manual Installation Instructions Service Instructions Replacement Parts List. Effective Date: October, 2012

The filling pressure of SUSPA gas springs depends on the extension force and the geometry and is between 10 and 230 bar.

Stainless steel gas springs with stainless steel hand operated blocking valve. Allows the Gas spring to be stopped in any position by turning wheel.

Installation manual. Toyota Tundra 4WD & 2WD. 2.5 Suspension kit. Part # Part # Important customer information:

HYDRAULIC SPRING COMPRESSOR SET

Installation instructions

Installation Instructions Complete set active Sound incl. Soundbooster Mercedes A-Klasse W176

SW14.5TI INTEGRAL HYDRAULIC FLANGE SPREADING WEDGE. Repair Manual INNOVATION IN ITS MOST FUNCTIONAL FORM

Installation Instructions Complete set Active Sound incl. Soundbooster Audi A3 8P

7783-A B C4

Installation manual. 2 Suspension System. Ford F150 4WD and 2WD. Part # Part # Ford F150 4WD and 2WD

Installation manual Toyota Tundra 4WD & 2WD - 2 front leveling kit Toyota Sequoia 4WD & 2WD - 2 front leveling kit Part # 52070

UNLEASH THE POWER REAL-WORLD SOLUTIONS

EQUALIZER International Limited 10T(I) Integral Hydraulic Spreading Wedge Repair Instruction Manual

Oil Dampers with Fixings on Both Ends

DICTATOR Final Dampers

Installation Instructions Convertible Top Interface Porsche. 997 Cabrio. Article-ID Version

Operation and Maintenance Manual for Joyce Dayton. Integrated Actuator- Acme Screw. Maximum capacity: 2000-pounds

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Every movement under control: individually adapted gas struts

Safety Shock Absorbers SDH38 to SDH63

Installation instructions

Rhino VE Follower Modules

4-Ton Electric Log Splitter

ADJUSTABLE SUSPENSION SYSTEM

ACTUATOR LA31 PRODUCT DATA SHEET

TOYOTA L/C TRANSFER CASE TWIN STICK

EPIC. Express Line Proudly Manufactured in the USA by Check-All Valve. Rev. E

JARVIS. Model Hydraulic Cutter EQUIPMENT... TABLE OF

Installation instructions

FPC815 Pneumatic Rivet Tool

700 bar Hand Pump BT-715

Pallet Stoppers WPS 500. Deceleration Technology. ONLINE 2D / 3D CAD Download

USE AND MAINTENANCE MANUAL

Operation & Service Manual

Further information: Berriman Associates Model 850P.2 Owners Manual

(42001) Neck Massager / Masseur de cou User Manual / Manuel de l utilisateur

ILED Aquarius Illuminated Windsock. User Manual

OPERATION AND PARTS MANUAL

Installation manual. 1.5 front leveling kit. Nissan Titan. Part # Part # Important customer information: Nissan Titan

DeZURIK KUL KNIFE GATE VALVES

(800) MON-FRI 7AM-5PM PST OR WEBSITE: ReadyLIFT.COM **Please retain this document in your vehicle at all times**

Installation and Operation Manual for VMAC Accessory A / A Air Receiver Tanks

Operation & Service Manual

Miniature Shock Absorbers SC²25 to SC²650 Self-Compensating

Installation manual Complete set active Sound incl. Soundbooster Skoda Octavia 5E

Owners manual. Öhlins Superbike front fork FG 170

Contents. 1.2 Cartridge maintenance Replacement of the cartridge gasket Piston segment replacement Piston replacement 20

Neptune X6 12/24V SAE 316L Stainless Steel Low Profile Through-Hull Mounted Underwater LED Light Manual

product data sheet Usage: Duty cycle: Max 10% or 2 minutes continuous use followed by 18 minutes not in use Ambient temperature: +5 to + 40 C

Workshop manual 5018 PDS Product Exploded View Disassembly & Assembling. Shock absorber 5018 PDS OEM Shock absorber 5018 PDS /2002

ACTUATOR LA31 PRODUCT DATA SHEET

Propane torch. Model Assembly And Operation Instructions

(877) MON-FRI 7AM-5PM PST OR WEBSITE: ReadyLIFT.COM **Please retain this document in your vehicle at all times**

FOX Racing Shox Bypass Technical Manual.

Miniature Shock Absorbers SC190 to SC925 Soft-Contact and Self-Compensating

Futura/Symphony, Legacy, Melody/Soprano, Maxi +, Alpha, Jazz

(800) MON-FRI 7AM-5PM PST OR WEBSITE: ReadyLIFT.COM **Please retain this document in your vehicle at all times**

Pull Type Gas Springs

MANUAL - PNEUMATIC ACTUATORS, SERIES DA & SR - 1 -

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

OPERATION AND PARTS MANUAL

Installation Manual. Uniball Upper Control Arm Kit Toyota Tacoma 4x Toyota 4Runner 4x Toyota Tundra 4x4 Part # 50965

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

Printed: Doc-Nr: PUB / / 000 / 00

Installation instructions

Work shop manual. Öhlins Steering damper Road & Track

Workshop manual 3612 / 4681 BAVP. Product Exploded View Disassembly & Assembling. Shock absorber

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

Ford Meter Box Test Bench Installation Instructions

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL

6200 Series. Specifications. Fluid End Power End Models 6211, 6212, 6221, & 6222 Models 6241 & 6242 Part Material Part Material Part Material

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

IN & TM Series User Manual

Miniature Shock Absorbers MC150 to MC600 Self-Compensating

1. General Description

INSTRUCTION. Internal pump elements APP6.5 - special 180B R R9134

TT-12 OWNERS MANUAL/PARTS LIST

Changing the Struts on a WK Jeep CRD

ELECTRICAL HAZARD EXAMPLES

Installation instructions

Installation instructions

Installation instructions

EPIC. express line. Proudly Manufactured in the USA by Check-All Valve Rev. D

Transcription:

T 0134 151 F 0134 445 www.kentgassprings.com

A FLEIBLE APPROACH TO GAS SPRINGS STANDARD GAS SPRINGS BESPOKE GAS SPRINGS STEEL or STAINLESS STEEL SHORT PRODUCTION TIMES SMALL or LARGE QUANTITIES GAS SPRING CALCULATION SERVICE With over 20 years of experience within the gas spring industry, we have collated a vast portfolio of knowledge of differing gas spring applications. Kent Gas Springs provide high quality bespoke, standard or stainless steel gas springs and support our customers with our industry leading technical backup service. This gives our customers full confidence that the best results are being achieved from their applications. Our bespoke and standard gas strut production lead times are consistently between 5-7 working days for small quantities and 3-5 weeks for larger quantities. All Kent Gas Springs are produced under an ISO001:2000 certified quality production system. WE WILL BE PLEASED TO SHOW YOU THE DIFFERENCE Kelvin & Jonathan Leason KENT GAS SPRINGS, a division of Gate Control Gear Limited T: +44 (0)134 151 F: +44 (0)134 445 E: solutions@kentgassprings.com www.kentgassprings.com

GAS SPRING IDENTIFICATION QUESTIONNAIRE Please tick appropriate box: PUSH TYPE PULL TYPE LOCKING TYPE CYLINDER END C = Extended Length PISTON ROD END B = Compressed Length A = Stroke EYELET EYELET E = Cylinder Diameter D = Rod Diameter BALL JOINT BALL JOINT CLEVIS FORK NOTE: Please ensure that the dimension of the end fittings that you require are filled in below: CLEVIS FORK M THREAD (MALE) THREAD (MALE) M GAS SPRING INFORMATION A = mm B = mm C = mm D = mm E = mm END FITTING INFORMATION & DIMENSIONS Cylinder End Piston Rod End Tick one box Tick one box Eyelet = mm Eyelet =...mm Ball Joint =..mm Ball Joint =..mm Clevis Fork =..mm Clevis Fork =..mm Thread =..mm Thread =..mm FORCE =. (Newtons) M =..mm M =..mm KENT GAS SPRINGS, a division of Gate Control Gear Limited. T: +44 (0)134 151 F: +44 (0)134 445 E: solutions@kentgassprings.com www.kentgassprings.com

Gas spring 4-12 Gasdruckfeder 4-12 Standard dimensions in mm S 4 4 Eyelet S L1(Stroke) 4 12 12 L 2 +/-2 mm (extended) 12 M4 Standard Specifications Thread L1 (STROKE) L2 (ETENDED LENGTH) FORCE F1(N) 7 MIN. MA. 20 0 MIN. 0 MA. 270 20-0 7 Plastic Ball Socket P5 M4 Technical Data KENT Gas springs are self contained and maintenance free. P5 Mounting Position : Can be mounted in any position, but we B M4 recommend mounting with Position downwards so that the damping is effective at the end of extension stroke. End position damping length : approximately (15mm) Temperature range : -30 to +0 C Ball Joint B.3 M4 Medium : Nitrogen gas and oil (for end position damping) Material : Black Nitriding piston rod, Body : Epoxy coated or powder coated. 4 M4 End fitting : Zinc plated, Plastic, Steel, Stainless steel and aluminum. C5 4 C5 1 1 K1 M4 K1 Please mention "00" in the part number if you do not require the end fittings. Ordering Example G 12 S 30 0 B1 S S2 350N V Some end fittings are interchangeable and must be positively secured by the customer to prevent unscrewing (i.e. loctite). Valve (optional) F1 : Force ( Newton) Tube End Connector (optional) Rod End Connector L2 : Extended Length L1 : Stroke Stainless Steel (optional) Series(Tube Dia) (optional) Type(Compression Gas spring) 7 V Add 7mm in L2 (Extended Length) if Adjustment Valve needed ADJUSTMENT VALVE : This bleed valve is optional and is used in the gas spring to lower the F1(N) force inside the cylinder. It is typically used where the force required is unknown. If you have variety of applications, one type of gas spring can be used by simple adjustment. The gas springs with the bleed valve come with the maximum force F1(N) and it must be bleeded until the satisfactory results of your application have been achieved. We reserve the right to make modifications Gas Springs G 04 1/03/20 c 20 Kent GaS Springs If you have any questions about specifying your requirement please e-mail us at solutions@kentgassprings.com or call us on + 44 (0)134 151 Log on to our website www.kentgassprings.com

Gas spring -15 Gasdruckfeder -15 Standard dimensions in mm S2 EyeLet S2 L1(Stroke) 15 1 L 2 +/-2 mm (extended) 1 Standard Specifications Thread L1 (STROKE) L2 (ETENDED LENGTH) FORCE F1(N) MIN. MA. 20 200 MIN. 120 MA. 450 50-400 Plastic Ball Socket P7 Technical Data KENT Gas springs are self contained and maintenance free. P7 Mounting Position : Can be mounted in any position, but we B1 recommend mounting with Position downwards so that the damping is effective at the end of extension stroke. End position damping length : approximately (30mm) Temperature range : -30 to +0 C Ball Joint B1 Medium : Nitrogen gas and oil (for end position damping) Material : Black Nitriding piston rod, Body : Epoxy coated or powder coated. End fitting : Zinc plated, Plastic, Steel, Stainless steel and aluminum. C1 C1 24 24 A1 A1 Please mention "00" in the part number if you do not require the end fittings. Ordering Example G 15 S 30 0 B1 S S2 350N V Some end fittings are interchangeable and must be positively secured by the customer to prevent unscrewing (i.e. loctite). Valve (optional) F1 : Force ( Newton) Tube End Connector (optional) Rod End Connector L2 : Extended Length L1 : Stroke Stainless Steel (optional) Series(Tube Dia) (optional) Type(Compression Gas spring) V Add 7mm in L2 (Extended Length) if Adjustment Valve needed ADJUSTMENT VALVE : This bleed valve is optional and is used in the gas spring to lower the F1(N) force inside the cylinder. It is typically used where the force required is unknown. If you have variety of applications, one type of gas spring can be used by simple adjustment. The gas springs with the bleed valve come with the maximum force F1(N) and it must be bleeded until the satisfactory results of your application have been achieved. We reserve the right to make modifications Gas Springs G 0 1/03/20 c 20 Kent GaS Springs If you have any questions about specifying your requirement please e-mail us at solutions@kentgassprings.com or call us on +44 134 151 or log on to our website www.kentgassprings.com

Gas spring - Gasdruckfeder - Standard dimensions in mm S4 1 EyeLet S4 L1(Stroke) L 2 +/-2 mm (extended) Standard Specifications Thread L1 (STROKE) L2 (ETENDED LENGTH) FORCE F1(N) MIN. MA. 25 400 MIN. 120 MA. 50 0-700 Plastic Ball Socket P7 Technical Data KENT Gas springs are self contained and maintenance free. P7 Mounting Position : Can be mounted in any position, but we B2 recommend mounting with Position downwards so that the damping is effective at the end of extension stroke. End position damping length : approximately (40mm) Temperature range : -30 to +0 C Ball Joint B2 Medium : Nitrogen gas and oil (for end position damping) Material : Black Nitriding piston rod, Body : Epoxy coated or powder coated. End fitting : Zinc plated, Plastic, Steel, Stainless steel and aluminum. C4 C4 24 24 A1 A1 Please mention "00" in the part number if you do not require the end fittings. Ordering Example G S 30 0 B1 S S2 350N V Some end fittings are interchangeable and must be positively secured by the customer to prevent unscrewing (i.e. loctite). Valve (optional) F1 : Force ( Newton) Tube End Connector (optional) Rod End Connector L2 : Extended Length L1 : Stroke Stainless Steel (optional) Series(Tube Dia) (optional) Type(Compression Gas spring) V Add 7mm in L2 (Extended Length) if Adjustment Valve needed ADJUSTMENT VALVE : This bleed valve is optional and is used in the gas spring to lower the F1(N) force inside the cylinder. It is typically used where the force required is unknown. If you have variety of applications, one type of gas spring can be used by simple adjustment. The gas springs with the bleed valve come with the maximum force F1(N) and it must be bleeded until the satisfactory results of your application have been achieved. We reserve the right to make modifications Gas Springs G 0 1/03/20 c 20 Kent GaS Springs If you have any questions about specifying your requirement please e-mail us at solutions@kentgassprings.com Call us on +44 (0)134 151 or log on to our website www.kentgassprings.com

Gas spring - Gasdruckfeder - Standard dimensions in mm S5 1 EyeLet S5 L1(Stroke) L 2 +/-2 mm (extended) M Standard Specifications Thread L1 (STROKE) L2 (ETENDED LENGTH) FORCE F1(N) MIN. MA. 50 500 MIN. 200 MA. 10 150-10 Plastic Ball Socket P20 M Technical Data KENT Gas springs are self contained and maintenance free. P20 Mounting Position : Can be mounted in any position, but we B4 M recommend mounting with Position downwards so that the damping is effective at the end of extension stroke. End position damping length : approximately (45mm) Temperature range : -30 to +0 C Ball Joint B4 13 30 M Medium : Nitrogen gas and oil (for end position damping) Material : Black Nitriding piston rod, 30 Body : Epoxy coated or powder coated. M End fitting : Zinc plated, Plastic, Steel, Stainless steel and aluminum. C4 C4 32 32 M C24 C24 Please mention "00" in the part number if you do not require the end fittings. Ordering Example G S 30 0 B1 S S2 350N V Some end fittings are interchangeable and must be positively secured by the customer to prevent unscrewing (i.e. loctite). Valve (optional) F1 : Force ( Newton) Tube End Connector (optional) Rod End Connector L2 : Extended Length L1 : Stroke Stainless Steel (optional) Series(Tube Dia) (optional) Type(Compression Gas spring) V Add 7mm in L2 (Extended Length) if Adjustment Valve needed ADJUSTMENT VALVE : This bleed valve is optional and is used in the gas spring to lower the F1(N) force inside the cylinder. It is typically used where the force required is unknown. If you have variety of applications, one type of gas spring can be used by simple adjustment. The gas springs with the bleed valve come with the maximum force F1(N) and it must be bleeded until the satisfactory results of your application have been achieved. We reserve the right to make modifications Gas Springs G 1/03/20 c 20 Kent GaS Springs If you have any questions about specifying your requirement please e-mail us at solutions@kentgassprings.com Call us on + 44 (0)134 151 Log on to our website www.kentgassprings.com

Gas spring -2 Gasdruckfeder -2 Standard dimensions in mm S7 1 EyeLet S7 L1(Stroke) 2 30 L 2 +/-2 mm (extended) 30 M Standard Specifications Thread L1 (STROKE) L2 (ETENDED LENGTH) FORCE F1(N) 12 MIN. MA. 0 700 MIN. 10 MA. 100 200-2500 12 M Technical Data Ball Joint B KENT Gas springs are self contained and maintenance free. Mounting Position : Can be mounted in any position, but we B 20 35 M recommend mounting with Position downwards so that the damping is effective at the end of extension stroke. 35 End position damping length : approximately (0mm) Temperature range : -30 to +0 C M Medium : Nitrogen gas and oil (for end position damping) C3 Material : Black Nitriding piston rod, Body : Epoxy coated or powder coated. C3 40 End fitting : Zinc plated, Plastic, Steel, Stainless steel and aluminum. 40 B7 M B7 1 35 35 12 V Please mention "00" in the part number if you do not require the end fittings. Ordering Example G 2 S 30 0 B1 S S2 350N V Some end fittings are interchangeable and must be positively secured by the customer to prevent unscrewing (i.e. loctite). Valve (optional) F1 : Force ( Newton) Tube End Connector (optional) Rod End Connector L2 : Extended Length L1 : Stroke Stainless Steel (optional) Series(Tube Dia) (optional) Type(Compression Gas spring) Add mm in L2 (Extended Length) if Adjustment Valve needed ADJUSTMENT VALVE : This bleed valve is optional and is used in the gas spring to lower the F1(N) force inside the cylinder. It is typically used where the force required is unknown. If you have variety of applications, one type of gas spring can be used by simple adjustment. The gas springs with the bleed valve come with the maximum force F1(N) and it must be bleeded until the satisfactory results of your application have been achieved. We reserve the right to make modifications Gas Springs G 1/03/20 c 20 Kent GaS Springs If you have any questions about specifying your requirement please e-mail us at solutions@kentgassprings.com Call us on +44 (0)134 151 Log on to our website www.kentgassprings.com

Gas spring 20-40 Gasdruckfeder 20-40 Standard dimensions in mm S 25 EyeLet S L1(Stroke) 20 40 45 L 2 +/-2 mm (extended) 45 M Standard Specifications Thread L1 (STROKE) L2 (ETENDED LENGTH) FORCE F1(N) 15 MIN. MA. 0 00 MIN. 35 MA. 00 500-3500 15 M Technical Data Ball Joint B KENT Gas springs are self contained and maintenance free. Mounting Position : Can be mounted in any position, but we B 2 45 M recommend mounting with Position downwards so that the damping is effective at the end of extension stroke. 45 End position damping length : approximately (0mm) Temperature range : -30 to +0 C M Medium : Nitrogen gas and oil (for end position damping) C4 Material : Black Nitriding piston rod, Body : Epoxy coated or powder coated. C4 5 End fitting : Zinc plated, Plastic, Steel, Stainless steel and aluminum. 5 M B B 1 45 45 15 V Please mention "00" in the part number if you do not require the end fittings. Ordering Example G 40 S 30 0 B1 S S2 350N V Some end fittings are interchangeable and must be positively secured by the customer to prevent unscrewing (i.e. loctite). Valve (optional) F1 : Force ( Newton) Tube End Connector (optional) Rod End Connector L2 : Extended Length L1 : Stroke Stainless Steel (optional) Series(Tube Dia) (optional) Type(Compression Gas spring) Add mm in L2 (Extended Length) if Adjustment Valve needed ADJUSTMENT VALVE : This bleed valve is optional and is used in the gas spring to lower the F1(N) force inside the cylinder. It is typically used where the force required is unknown. If you have variety of applications, one type of gas spring can be used by simple adjustment. The gas springs with the bleed valve comes with the maximum force F1(N) and it must be bleeded until the satisfactory results of your application have been achieved. We reserve the right to make modifications Gas Springs G 20 1/03/20 c 20 Kent GaS Springs If you have any questions about specifying your requirement please e-mail us at solutions@kentgassprings.com Call us on +44 (0)134 151 Log on to our website www.kentgassprings.com

Gas Spring Brackets (Standard) Bracket 001 Bracket 002 Bracket 003 Bracket 004 Bracket 011 KENT GAS SPRINGS, a division of Gate Control Gear Limited T: +44 (0)134 151 F: +44 (0134 445 E: solutions@kentgassprings.com www.kentgassprings.com

Important Installation & Warranty Advice 1. Kent gas springs will operate in surrounding temperatures from 30 C to +0 C. We can supply our gas springs with special seals to withstand temperatures as low as 55 C or as high as +200 C. Gas Springs should not be over heated or placed in open fire! Other environmental conditions can also influence the considerable life time of gas springs. Please take appropriate preventative measures into consideration. 2. Gas Springs are filled with pure nitrogen. Nitrogen is an inert gas, which does not burn, will not explode and is not poisonous. But: Gas springs have very high internal pressure (up to approximately 300 bar). Do not open without instruction! 3. Disposal/Recycling: Gas springs consist mostly of metal and can be recycled, but first the gas spring must be de-pressurized. 4. All gas springs are labelled with the warning. DO NOT OPEN, HIGH PRESSURE, the part number and the production date. If these dates are unreadable (removed, painted over or any other influences) we refuse the liability for damages which result of this fact. Warranties are then not applicable anymore. 5. Gas springs should be installed with the piston rod downwards. This position ensures the best damping effect.. Gas Springs should not be exposed to any tilting or side (lateral) forces during operation. If this is unavoidable, please check the installation and use suitable connecting parts. 7. Gas springs are maintenance free. Do not grease or oil the piston rod.. The piston rod must not be painted and should be protected against shocks, impact, scratches & dirt. The cylinder should not be deformed. Such damage will destroy the sealing system.. Kent gas springs can be stored short term in any position. Pressure loss through long term storage may be possible in certain conditions. There are no negative values known, but there may be a sticking effect when you compress a gas spring, which may require a higher expenditure of force the first few times (initial break away force).. We cannot assume any liability for the function and the lifetime of the final product that you fit the gas springs upon. 11. Warranty claims expire one year from the date of supply. Manufacturing mistakes and/or quality defects are immediately noticeable. If you are unhappy for any reason with the delivered quality, we ask you to return the gas springs immediately. Testing methods adopted by customers must be the same as in production in order to achieve the same conditional matching results. 12. If gas springs are sent to us for a detailed examination, the agreement for the destruction of this part is given and the property rights expire. A return delivery of single components is not possible. 13. Kent gas springs which mostly consist of parts held in stock are produced according to customers orders. A cancellation, modification afterwards, change or refusal is therefore not possible.. Without detailed specifications supplied to us at enquiry stage and our specific written agreement, our gas springs will not be guaranteed for special applications involving vibration, magnetic fields, stray currents or intense accidental loads etc.. KENT GAS SPRINGS, a division of Gate Control Gear Limited T: +44 (0)134 151 F: +44 (0)134 445 E: solutions@kentgassprings.com www.kentgassprings.com

A division of GATE CONTROL GEAR LIMITED 17 Rochester Trade Park Maidstone Road Rochester Kent ME1 3QY UNITED KINGDOM T 0134 151 F 0134 445 E solutions@kentgassprings.com www.kentgassprings.com