Catalogue Index. Pressure gauges Model Data Sheet Page. High Purity cleaned Gauges stainless Steel Wetted Parts APM 130.

Similar documents
Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Ultra High Purity Transducer, Ex na nl Models WU-20, WU-25 and WU-26

Ultra High Purity Transducer, Ex na n Models WUC-10, WUC-15 and WUC-16

Ultra High Purity Transducer, Ex na ic Models WUC-10, WUC-15 and WUC-16

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Pressure transmitter for general applications Model S-10, standard version Model S-11, flush diaphragm

Differential pressure gauge Model , copper alloy Model , stainless steel version

OEM Pressure Transmitters

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Bourdon Tube Pressure Gauges with Switch Contacts Models /160, Stainless Steel Version Models /160, Stainless Steel Safety Version

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Bourdon tube pressure gauges with switch contacts Models PGS23.1x0, stainless steel version

Industrial Pressure Transmitters

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Type A-10 General Purpose Pressure Transmitters

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

OEM Pressure Transmitters

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

Pressure Transmitters for Sanitary Applications Model SA-11

Mechatronic pressure measurement. Applications. Special features. Description

Bourdon tube pressure gauge with switch contacts Models PGS21.1x0, industrial series

Diaphragm monitoring system with clamp connection For sanitary applications Model DMS-FP

Pressure gauge in stainless steel version. Suitable for aggressive media and environments. Aluminium, white with black lettering

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Type A-10 General Purpose Pressure Transmitter

Pressure Gauge. Bourdon Tube Pressure Gauges with Switch Contacts Models MBSA, Stainless Steel Version. Applications. Special Features.

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Product Catalog. Our Products. DCI Dynamic Instruments Website: dcidynamic.com

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Gas-actuated thermometer with switch contacts For sanitary applications, stainless steel version Model 74

Bourdon tube pressure gauge with switch contacts Stainless steel case Model PGS21, NS 100 and 160

Compact differential pressure switch Models DC, DCC

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

Pressure gauge per EN with mounted diaphragm seal With threaded connection, threaded design Model DSS10M

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Pressure gauge in hygienic design with mounted diaphragm seal With clamp connection Model DSS22P

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

SITRANS P measuring instruments for pressure

Portable pressure calibrator, Wally Box III Model CPH7600

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Compact pressure switch Model PCS

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

Gas-actuated thermometer with switch contacts Model 73, stainless steel version

Flap-Type Flow Meter Prall

Bourdon tube pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21PB, NS 60, 80 and 100

Special Purpose Transmitters

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

Process Industry. Diaphragm Seal Solutions

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Bourdon tube pressure gauge, copper alloy Panel mounting series Models and

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

U.S. GAUGE PMT PRODUCTS 820 PENNSYLVANIA BLVD., FEASTERVILLE, PENNSYLVANIA U.S.A. TEL: (215) FAX: (215)

Duplex pressure gauge per DIN Panel mounting series for rail-vehicle braking systems Model PG21DPB, NS 60, 80, 100 and 130

ALL STAINLESS STEEL PRESSURE GAUGE

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

ALL SS ELECTRIC CONTACT PRESSURE GAUGE

Mechanical pressure gauges

Model Pressure range ON/OFF output Linear output

Pressure Transmitter JUMO dtrans p30 Type

Pressure transmitter COMPACT ECOnomic

SANITARY PRESSURE GAUGES

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Pressure gauge per EN with mounted diaphragm seal With clamp connection Model DSS22F

Gas-actuated thermometer Model 73, stainless steel version

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Bimetal thermometer Model 52, industrial series

All Stainless Steel / SS Case Pressure Gauge

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

Ar-Mite TM Low Flow Armored Flowmeter

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Pressure transducer DMU 01K Compact version

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

ALL SS ELECTRIC CONTACT PRESSURE GAUGE

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

SBM TECHNOLOGY PET Blow Valve Block

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

PFT - the Flexible Pressure Transmitter

Pressure transmitter PASCAL CV4

Bimetal Thermometers Model 54, Heavy Duty Series

Transcription:

Catalogue Index Pressure gauges Model Data Sheet Page High Purity cleaned Gauges stainless Steel Wetted Parts 130.15 APM 130.15 1-2 Process industry gauge 40 and 50 mm 131.12 PM 01.06 3-4 with Twist Lock Window - 2'' 131.15 PM 01.07 5-6 Bourdon Tube 230.25 APM23025 7-10 Ultra High Purity Process with inductive switch Stainless Steel Case 316L VIM/VAR Wetted Material 230.25+8301E APM01.25.3 11-14 for Clean Dry Air Applications, Safety Pressure Gauges with Solid Baffle Wall acc. to EN 837-1 232.35 PM 02.11 15-16 UHP Flow-Through-Gauge, Nominal Size 1 1/8'' 432.25 PM 04.10 17-18 UHP Flow-Through-Gauge, Nominal Size 1 1/2'' 432.25 PM 04.11 19-20 UHP Flow-Through-Gauge, Nominal Size 2'' 432.25 PM 04.12 21-22 Transducer / Attachable Indicator / indicator Model Data Sheet Page Ultra High Purity Transducer, "Non-Incendive", Single End NWU-10 PE 87.10 23-26 Ultra High Purity Pressure Transducer WU-10 / WU-15 / WU-16 PE 87.05 27-32 Ultra High Purity Attachable indicator with LED WUR-1 PE 87.20 33-36 Ultra High Purity Attachable indicator with LED, "Non-Incendive" NWUR-1 PE 87.21 37-40 Digital indicator DI30 AC 80.05 41-44 HYDRA-Line pressure masurement for UHP chemicals Model Data Sheet Page with mechanical indication HG SP 99.20 45-48 with electrical output HS SP 99.21 49-52 with electrical output, no transmitting fluid inside HD SP 99.22 53-56 LED-indicator for type HD HI SP 99.23 57-60 Diaphragm Seal 990.80 SP 99.25 61-62 Accessories Model Data Sheet Page Gas cylinder scale AC 09.13 63-64 Low and differential pressure transmitter for cleanroom and filter monitoring DP-10 PE 81.06 65-68

Pressure Systems Bourdon Tube Pressure Gauges High Purity Cleaned Gauges Stainless Steel Wetted Parts Type 130.15 Application Fluid mediums for semiconductor, Clean Dry Air (CDA), and other high purity applications that require both high purity cleaning and a high degree of accuracy. Fluid medium which does not corrode 316 stainless steel. Any medium which oxidizes with oil based materials. Sizes 2" (50 mm) Accuracy + 2/1/2% of span (ASME B40.1 Grade A) Ranges (All ranges not stocked) Vacuum / Compound to 30"HG / 0 / 300 PSI Pressure from 15 PSI to 10,000 PSI or other equivalent units of pressure or vacuum Working Range Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating Temperature Ambient: -40 F to 140 F (-40 C to 60 C) Media: max. 140 F (+60 C) Temperature Error Additional error when temperature changes from reference temperature of 68 F (20 C) +0.4% for every 18 F (10 C) rising or falling. Percentage of span. Standard Features Connection Material: 316 stainless steel Lower mount (LM) Center back mount (CBM) 1/8" or 1/4" NPT limited to wrench flat area Bourdon Tube Material: 316 stainless steel 15 PSI to 1,000 PSI C-type 1,500 PSI to 10,000 PSI helical type Helium leak tested 2 x 10-9 (Inboard) Movement Stainless steel Dial White aluminum with stop pin and black lettering Pointer Black aluminum Case Electropolished stainless steel Window Twist-lock polycarbonate -1- Cleanliness ASME B40.1 Level IV (for oxygen service) Cleaned and packaged in a Class 100 cleanroom Packaged in single nylon bag Purged with Nitrogen Protective cap over thread connection Order Options (min. order may apply) Alarm contact (830.1E) Monel wetted parts Hastelloy wetted parts Packaged in two nylon bags Other special connections limited to wrench flat area Custom dial layout Stainless steel restrictor Particle test with certificate Dual scales APM 130.15 (APM 01.05.2)

TYPE WEIGHT KEY A B C D E I L M 130.15 2" mm 57.8 29 11 50.7 49.3 14 --- 18.5 0.25 lbs. LM in 2.28 1.14 0.43 2.0 1.94 0.55 1/4" NPT 0.73 130.15 2" mm 57.8 29 11 50.7 55.1 14 --- --- 0.31 lbs. CBM in 2.28 1.14 0.43 2.0 2.17 0.55 1/4" NPT --- THE MEASURE OF Total Performance TM Ordering Information: State computer part number (if available) / type number / size / range / connection size and location / options required. Specifications given in this price list represent the state of engineering at the time of printing. Modifications may take place and the specified materials may change without prior notice. 11/2003-2-

PM 01.06 Pressure Gauges Bourdon Tube Pressure Gauges for Clean Dry Air Applications Stainless Steel Series Nominal Size 40, 50, 63 mm Model 131.12 Service intended Suitable for gaseous, liquid and corrosive media, also in a corrosive environment, for demanding high purity applications. Suitable for CDA (Clean Dry Air) applications. Fields of application are especially the semiconductor and electronic industry, medical industry, gene technology, biotechnology and pharmaceutical industry. Design Safety pattern gauge to EN 562 / ISO 5171, leak proof, leak rate 10-8 mbar l/s pressure connection NPT thread (standard) resp. original VCR Fitting with front sealing pressure connection Nominal size 40, 50, 63 mm Accuracy 2/1/2% of span (ASME B 40.1 Grade A) in compliance with accuracy class 1.6 per EN 837-1 /6 Scale ranges (EN 837-1 /5) 0... 1 to 0... 400 bar (0... 15 to 0... 6000 psi) or other equivalent units of pressure or vacuum Model 131.12! VCR - male nut Working pressure Steady: : x of full scale value Fluctuating: b x of full scale value Short time: full scale value Operating temperature Ambient: -40... +60 C Medium: +100 C maximum Temperature effect When temperature of the pressure element deviates from reference temperature (+20 C): max. ±0.4 %/10 K of true scale value Pressure connection Material: stainless steel 316 L (1.4404), lower mount (LM) or centre back mount (CBM), surface finish Ra 0,6 µ m! ¼ NPT - male thread (standard)! VCR compatible face seal fittings: with union nut (female) with male nut! Fixed body 9/16-18 UNF Pressure element Material: stainless steel 316 L (1.4404), < 100 bar: C-type 100 bar: helical type Movement Stainless steel Dial White aluminium, with pointer stop pin With black/red lettering, dual pressure scale (psi/bar), inscription "use no oil" or equivalent to prohibition symbol Pointer Black aluminium pointer Case Stainless steel Window Polycarbonate, snap-fit window Cleaning Cleaned for oxygen service to ASME B 40.1 (Level I) Optional extras - Better finish for wetted parts (pressure connection) Ra 0.3 µ m - Case stainless steel, electropolished - Alarm contacts (50 mm) Sliding contact (Model 811) Inductive contact (Model 831) -3-

Dimensions [mm] Radial bottom pressure entry (LM) ¼ " NPT male VCR union nut (female) SS-4-VCR-1 VCR male nut SS-4-VCR-4 Fixed body 9/16-18 UNF union nut (female) male nut 2411 258.01 Nominal size Dimensions [mm] D H1 H2 H3 H4 50 49 43 54 64 47 63 62 54 57 67 58 Centre back pressure entry (CBM) ¼ " NPT male VCR union nut (female) SS-4-VCR-1 VCR male nut SS-4-VCR-4 only for NS 50 and NS 63 union nut (female) male nut 2411 266.01 Fixed body 9/16-18 UNF Nominal size Dimensions [mm] D H1 H2 H3 H4 L 40 39 46 57 67 50 27 50 49 49 57 67 53 28 63 62 49 57 67 53 28 Ordering information State: Pressure gauge model / Nominal size / Scale range / Size and location of connection / Optional extras required Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. 9029923 05/2004 GB -4-

PM 01.07 Bourdon Tube Pressure Gauges for Clean Dry Air Applications Pressure Gauges with Twist Lock Window Model 131.15 Service intended Suitable for gaseous, liquid and corrosive media, also in a corrosive environment, for demanding high purity applications. Suitable for all CDA (Clean Dry Air) applications. Fields of application are especially the semiconductor and electronic industry, medical industry, gene technology, biotechnology and pharmaceutical industry. Design Leak proof, leak rate 10-8 mbar l/s pressure connection NPT thread (standard) resp. original VCR Fitting with front sealing pressure connection Nominal size 2 " Accuracy 2/1/2% of span (ASME B 40.1 Grade A) in compliance with accuracy class 1.6 per EN 837-1 /6 Scale ranges 0... 1 to 0... 400 bar (EN 837-1 /5) 0... 15 to 0... 6000 psi (ASME B 40.1) or other equivalent units of pressure or vacuum Working pressure Steady: : x of full scale value Fluctuating: b x of full scale value Short time: full scale value Operating temperature Ambient: -40... +60 C Medium: +100 C maximum Temperature effect When temperature of the pressure element deviates from reference temperature (+20 C): max. ±0.4 %/10 K of true scale value Pressure connection Material: stainless steel 316 L (1.4404), lower mount (LM) or centre back mount (CBM), surface finish Ra 0,6 µ m! ¼ NPT - male thread (standard)! VCR compatible face seal fittings: with union nut (female) with male nut! Fixed body 9/16-18 UNF! Welding connection Pressure element Material: stainless steel 316 L (1.4404), < 100 bar: C-type 100 bar: helical type Movement Stainless steel Model 131.15! VCR - male nut Dial White aluminium, with pointer stop pin With black/red lettering, dual pressure scale (psi/bar), red inscription "use no oil" Pointer Black aluminium pointer Case Stainless steel, with pressure relief Window and bezel One-piece polycarbonate, screw on (Twist Lock) Cleaning Cleaned for oxygen service to ASME B 40.1 (Level I) Optional extras - Better finish for wetted parts (pressure connection) Ra 0.3 µ m - Case stainless steel, electropolished - 3-hole panel mounting flange, stainless steel, electro polished, with clamp (back entry only) - Panel mounting clamp, stainless steel, (back entry only) - Alarm contacts Electronic contact with NPN output (Model 830.1E) -5-

Dimensions [mm] Radial bottom pressure entry (LM) ¼ " NPT male VCR union nut (female) SS-4-VCR-1 VCR male nut SS-4-VCR-4 union nut (female) male nut Fixed body 9/16-18 UNF Welding connection 2099 226.02 Centre back pressure entry (CBM) ¼ " NPT male VCR union nut (female) SS-4-VCR-1 VCR male nut SS-4-VCR-4 male nut union nut (female) Fixed body 9/16-18 UNF Welding connection 2099 218.02 Ordering information State: Pressure gauge model / Nominal size / Scale range / Size and location of connection / Optional extras required Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. 9029729 05/2004 GB -6-

Pressure Gauges Bourdon Tube Pressure Gauges Ultra High Purity Stainless Steel Case 316L VIM/VAR Wetted Material Type 230.25 Application Fluid mediums for semiconductor and other high purity applications that require both a high degree of accuracy and ultra clean wetted surfaces. Sizes 2" (50 mm) 1½" (40mm) Accuracy ± 2/1/2% of span (ASME B40.1 Grade A) (2") ± 3/2/3% of span (ASME B40.1 Grade B) (1½") Ranges Vacuum / Compound to 30"Hg / 0 / 200 PSI Pressure from 15 PSI to 5,000 PSI or other equivalent units of pressure or vacuum Working Range Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating Temperature Ambient: -40 F to 140 F (-40 C to 60 C) Media: max. 212 F (+100 C) Temperature Error Additional error when temperature changes from reference temperature of 68 F (20 C) ±0.4% for every 18 F (10 C) rising or falling. Percentage of span. Standard Features Connection Material: 316L VIM/VAR, electropolished, 7 ra Avg. Lower mount (LM) Center back mount (CBM) VCR compatible face seal fittings Fixed male, male and female swivel, and NPT Bourdon Tube Material: 316L stainless steel 30"Hg (vac) to 1000 PSI "C" type 1500 PSI to 5,000 PSI helical type Helium leak tested 2 x 10-9 (Inboard) Movement 300 series stainless steel Dial White aluminum with stop pin and black lettering Pointer Black aluminum Case 304 stainless steel Weather Protection Weather resistant (IP 54) Window Twist-lock polycarbonate (2") Snap in acrylic (1½") ORDER OPTIONS (min. order may apply) Custom dials Weld-tee connector Modular surface mount (C, Mini C, W Seals available) Particle test with certificate Dual scales VCR is a registered trademark of Swagelok Companies Teflon is a registered trademark of DuPont Company APM 230.25-7-

Dimensions 230.25 2" LM FIXED MALE 230.25 2" LM MALE NPT 230.25 2" LM SWIVEL MALE 230.25 2" LM SWIVEL FEMALE TYPE/SIZE WEIGHT KEY A B C D E F G H I K L M 230.25 2" LM Fixed Male 230.25 2" LM NPT 230.25 2" LM Male Swivel 230.25 2" LM Female Swivel 0.25 lbs. 0.25 lbs. 0.25 lbs. 0.25 lbs. mm 57.8 25 11 50.7 47.8 -- -- -- 14 -- 9/16-18 UNF 18.5 in 2.275 1.425 0.43 2.0 1.88 -- -- -- 0.55 -- 0.73 mm 57.8 25 11 50.7 49.3 -- -- -- 14 -- 18.5 1/4" NPT in 2.275 1.425 0.43 2.0 1.94 -- -- -- 0.55 -- 0.73 mm 57.8 25 11 50.7 57.4 28.7 3 8.8 14 15.8 9/16-18 UNF 18.5 in 2.275 1.425 0.43 2.0 2.26.96 0.12 0.35 0.55 5/8" 0.73 mm 57.8 25 11 50.7 54.1 25.4 3 8.8 14 19 9/16-18 UNF 18.5 in 2.275 1.425 0.43 2.0 2.13 1.0 0.12 0.35 0.55 3/4" 0.73-8-

Dimensions 230.25 2" CBM FIXED MALE 230.25 2" CBM MALE NPT 230.25 2" CBM SWIVEL MALE 230.25 2" CBM SWIVEL FEMALE TYPE/SIZE WEIGHT KEY A B C D E F G H I K L 230.25 2" CBM Fixed Male 0.31 lbs. mm 57.8 29 11 50.7 56.6 - - - 14 - in 2.275 1.14 0.43 2.0 2.23 - - - 0.55-9/16-18 UNF 230.25 2" CBM NPT 0.31 lbs. mm 57.8 29 11 50.7 55.1 - - - 14 - in 2.275 1.14 0.43 2.0 2.17 - - - 0.55-1/4" NPT 230.25 2" CBM Male Swivel 0.31 lbs. mm 57.8 29 11 50.7 65.8 30.2 6.6 9.53 14 15.9 in 2.275 1.14 0.43 2.0 2.59 1.19 0.26 0.375 0.55 5/8" 9/16-18 UNF 230.25 2" CBM Female Swivel 0.31 lbs. mm 57.8 29 11 50.7 65.8 30.2 6.6 9.53 14 19 in 2.275 1.14 0.43 2.0 2.59 1.19 0.26 0.375 0.55 3/4" 9/16-18 UNF -9-

Dimensions 230.25 2" CBM U-CLAMP OPTION 230.25 2" CBM FRONT FLANGE OPTION TYPE/SIZE WEIGHT KEY A B C D J M N P R S T 230.25 2" CBM / UC 230.25 2" CBM / FF 0.44 lbs. 0.38 lbs. mm 57.8 30.3 12.6 53.4 -- 66.4 71 16 9.80 2.5 63 in 2.28 1.19 0.50 2.10 -- 2.61 2.80 0.63 0.39 0.10 2.48 mm 57.8 30.2 12.6 53.4 3.6 76.2 65 -- -- -- -- in 2.28 1.19 0.50 2.10 0.14 3.0 2.56 -- -- -- -- Recommended panel cutout = 55 mm (2.17 in.) 230.25 1.5" MODULAR SURFACE MOUNT 230.25 1.5" CBM SWIVEL FEMALE 230.25 1.5" CBM WELD-TEE TYPE/SIZE WEIGHT KEY A B C D E F G H I K L 230.25 1.5" MSM 0.22 lbs. mm 39 27.1 -- -- 73.2 22.4 6.35 9.53 14 in 1.54 1.07 -- -- 2.88 1.19 0.25 0.375 0.55-1.5" 230.25 1.5" CBM Swivel Female 0.22 lbs. mm 39 27.1 -- -- 65.3 22.4 6.35 9.53 14 in 1.54 1.07 -- -- 2.57 1.19 0.25 0.375 0.55 3/4" 1/4" 230.25 1.5" CBM Weld-Tee 0.22 lbs. mm 39 27.1 22.3 9.53 59.7 -- -- 9.53 14 in 1.54 1.07 0.88.375 2.35 -- -- 0.375 0.55 -- -- Ordering Information: State computer part number (if available) / type number / size / range / connection size and location / options required. WIKA reserves the right to make design changes without prior notice. 12/2004-10-

Pressure Gauges Bourdon Tube Pressure Gauges Ultra High Purity Process with inductive switch Stainless Steel Case 316L VIM/VAR Wetted Material Type 230.25 with 830.1E switch Application Fluid mediums for semiconductor and other high purity applications that require both a high degree of switching accuracy with ultra clean wetted surfaces. Sizes 2" (50 mm) Accuracy ± 2/1/2% of span (ASME B40.1 Grade A) Ranges Vacuum / Compound to 30"Hg / 0 / 200 PSI Pressure from 15 PSI to 5,000 PSI or other equivalent units of pressure or vacuum Working Range Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating Temperature Ambient: -40 F to 140 F (-40 C to 60 C) Media: max. 212 F (+100 C) Temperature Error Additional error when temperature changes from reference temperature of 68 F (20 C) ±0.3% for every 18 F (10 C) rising or falling. Percentage of span. Standard Features Connection Material: 316L VIM/VAR Lower mount (LM) Center back mount (CBM) VCR compatible face seal fittings Fixed male, male and female swivel, and NPT Bourdon Tube Material: 316L stainless steel 30"Hg (vac) to 1000 PSI "C" type 1500 PSI to 5,000 PSI helical type Helium leak tested to 2 x 10-9 (Inboard) Movement 300 series stainless steel Dial White aluminum with stop pin and black lettering Pointer Black aluminum Case 304 stainless steel Weather Protection Weather resistant (IP 45) Window Twist-lock polycarbonate Switch Data Operating voltage Switching current Voltage drop when I max Function of switching element Switching frequency Switching hysteresis Output signal Ambient temperature Other ambient conditions Contact assembly Cable length ORDER OPTIONS (min. order may apply) Hastelloy C-22 socket and Bourdon tube Custom dials Particle test with certificate Dual scale DC 8...30 V with 10% residual ripple < 100 ma and < 100 µa residual <0,7 V closing (open circuit causes alarm) 1000 Hz 0,10...0,20 mm NPN-transistor amplified signal -25...+70ºC according to the data sheet of basis model PMG-10 factory-mounted 1 meter Standard APM 01.25.3-11-

Dimensions 230.25 2" LM FIXED MALE 230.25 2" LM MALE NPT 230.25 with 830.1E switch 2" LM SWIVEL MALE 230.25 2" LM SWIVEL FEMALE TYPE/SIZE WEIGHT KEY A B C D E F G H I K L M 230.25 2" LM Fixed Male 230.25 2" LM NPT 230.25 2" LM Male Swivel 0.25 lbs. 0.25 lbs. 0.25 lbs. 230.25 2" LM 0.25 lbs. Female Swivel mm 57.8 29 11 50.7 47.8 -- -- -- 14 -- 9/16-18 UNF 18.5 in 2.275 1.14 0.43 2.0 1.88 -- -- -- 0.55 -- 0.73 mm 57.8 29 11 50.7 49.3 -- -- -- 14 -- 18.5 1/4" NPT in 2.275 1.14 0.43 2.0 1.94 -- -- -- 0.55 -- 0.73 mm 57.8 29 11 50.7 58.9 28.7 3 9.53 14 15.9 9/16-18 UNF 18.5 in 2.275 1.14 0.43 2.0 2.32 1.19 0.12 0.375 0.55 5/8" 0.73 mm 57.8 29 11 50.7 58.9 28.7 3 9.53 14 19 9/16-18 UNF 18.5 in 2.275 1.14 0.43 2.0 2.32 1.19 0.12 0.375 0.55 3/4" 0.73-12-

Dimensions 230.25 2" CBM U-CLAMP OPTION 230.25 2" CBM FRONT FLANGE OPTION TYPE/SIZE WEIGHT KEY A B C D J M N P R S T 230.25 2" CBM / UC 230.25 2" CBM / FF 0.44 lbs. 0.38 lbs. Recommended panel cutout = 55 mm (2.17 in.) mm 57.8 30.3 12.6 53.4 -- 66.4 71 16 9.80 2.5 63 in 2.28 1.19 0.50 2.10 -- 2.61 2.80 0.63 0.39 0.10 2.48 mm 57.8 30.2 12.6 53.4 3.6 76.2 65 -- -- -- -- in 2.28 1.19 0.50 2.10 0.14 3.0 2.56 -- -- -- -- -13-

Installation Instructions: 1. Remove standard twist-lock window from pressure gauge by turning counterclockwise. 2. Remove standard pointer from pressure gauge using a pointer puller tool (contact factory for more information on this special tool available from WIKA). 3. Calibrate the gauge by pressurizing gauge to a known value. WIKA suggests pressurizing to one of the printed numbers on the dial around the 12 o'clock position. Press the special flag-pointer (P/N 2140349) onto pointer hub tightly with the tip of the flag-pointer on the tick mark of the current pressure. For instance, on a 100 PSI gauge, WIKA suggests pressurizing to 50 PSI which is one of the printed numbers on the dial and is near 12 o'clock. In this case, the flag-pointer should be put on to the hub so that the tip is right at 50 PSI. 4. Attach the window assembly loosely onto the case with about a 1/4 turn. Make sure the yellow inductive sensor and the flag on the flag-pointer are separated. 5. Turn the center portion of the window so that the inductive sensor moves towards the flag of the flagpointer. Make sure that the flag runs through the middle of the inductive sensor. If there is any blockage, bend the flag by hand to a position that allows it to travel through the inductive sensor without touching the sensor. 6. Turn the center portion of the window so that the green setpoint line on the window corresponds to the pressure at which the alarm should activate. 7. Pressing the center portion of the window down to hold it in place, fully tighten the window (about another 1/2 turn). 8. It is possibe that the flag-pointer could be bent during shipping and handling causing the alarm to activate at the wrong pressure. The activation setpoint can be "tweaked" be either changing the position of the flag or changing the position of the inductive sensor. 9. For further technical assistance, contact WIKA Customer Service at 1-888-WIKA-USA. Dimensions Type 830.1E Pressure Switch Assembly Attached to 2" Pressure Gauge TYPE/SIZE WEIGHT KEY A B C Type 830.1E Pressure Switch Assembly (attached to 2" pressure gauge) 0.05 lbs. (Switch Only) mm 57.8 7.5 10 in 2.28 0.30 0.39 Output 3 (BK) makes connection to minus 2 (BU). The load (R L ) between 3 (BK) and 1 (BN) has to be large enough so that the max. switch-current 100 MA will not be exceeded. Do not make a direct connection between 1 (BN) and 3 (BK)! 03/01 Ordering Information: State computer part number (if available) / type number / size / range / connection size and location / options required. WIKA reserves the right to make design changes without prior notice. -14-

PM 02.11 Pressure Gauges Bourdon Tube Pressure Gauges for Clean Dry Air Applications Safety Pressure Gauges with Solid Baffle Wall acc. to EN 837-1 Model 232.35 S Service intended Suitable for gaseous, liquid and corrosive media, also in a corrosive environment, for demanding high purity applications. Suitable for all known CDA (Clean Dry Air) applications. Fields of application are especially the semiconductor and electronic industry, medical industry, gene technology, biotechnology and pharmaceutical industry. Design Safety pattern gauge with solid baffle wall in accordance with requirements and test conditions of EN 837-1 /9.7.2 leak proof, leak rate 10-8 mbar l/s pressure connection NPT thread (standard) resp. original VCR Fitting with front sealing pressure connection Nominal size 63 mm Accuracy 2/1/2% of span (ASME B 40.1 Grade A) in compliance with accuracy class 1.6 per EN 837-1 /6 Scale ranges 0... 1 to 0... 400 bar (EN 837-1 /5) 0... 15 to 0... 6000 psi (ASME B 40.1) or other equivalent units of pressure or vacuum Working pressure Steady: ¾ x of full scale value Fluctuating: B x of full scale value Short time: full scale value Operating temperature Ambient: -40... +60 C Medium: +100 C maximum Temperature effect When temperature of the pressure element deviates from reference temperature (+20 C): max. ±0.4 %/10 K of true scale value Ingress protection IP 54 to EN 60 529 / lec 529 Pressure connection Material: stainless steel 316 L (1.4404), lower mount (LM) or lower back mount (LBM), surface finish Ra 0,6 µ m! ¼ NPT - male thread (standard)! VCR compatible face seal fittings: with union nut (female) with male nut! Fixed body 9/16-18 UNF! Welding connection Pressure element Material: stainless steel 316 L (1.4404), < 100 bar: C-type 100 bar: helical type Movement Stainless steel Model 232.35! VCR - union nut (female) Dial White aluminium, with pointer stop pin With black/red lettering, dual pressure scale (psi/bar), red inscription "use no oil" Pointer Black aluminium pointer Case Stainless steel, with solid baffle wall (solid front) and blow-out back Window Laminated safety glass Bezel ring Cam ring (bayonet type), stainless steel Cleaning Cleaned for oxygen service to ASME B 40.1 (Level I) Optional extras - Better finish for wetted parts (pressure connection) Ra 0,3 µ m - Higher accuracy class 1.0 - Case and cam ring (bayonet type) electropolished - 3-hole panel mounting flange, stainless steel, electropolished, (back entry only) - Alarm contacts Magnetic snap-action contact (Model 821) Inductive contact (Model 831) Electronic contact (Model 830 E) Reed contact (Model 851) -15-

Dimensions [mm] Radial bottom pressure entry (LM) ¼ " NPT male VCR union nut (female) SS 4 VCR-1 VCR male nut SS 4 VCR-4 union nut (female) male nut Fixed body 9/16-18 UNF Welding connection 2121 271.01 Lower back pressure entry (LBM) ¼ " NPT male VCR union nut (female) SS 4 VCR-1 VCR male nut SS 4 VCR-4 union nut (female) male nut Fixed body 9/16-18 UNF Welding connection 2121 379.01 Ordering information State: Pressure gauge model / Nominal size / Scale range / Size and location of connection / Optional extras required Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. 9099310 05/2004 GB -16-

Mechanical Pressure Measurement UHP Flow-Through-Gauge Diaphragm Pressure Gauge, Nominal Size 1 1/8" Model 432.25 WIKA Data Sheet PM 04.10 Applications T Suitable for gaseous, liquid and corrosive media, also in a corrosive environment, for demanding high purity applications. T Semiconductor and flat panel industry T Gas distribution systems T Medical gases T Hook-up-application Special Features UHP Flow-Through-Gauge, Model 432.25.1 1/8" T No dead volume in the pressure gauge T Low internal volume for reducing particle generation and entrapment T Compact design T Helium leak tested, leak rate 10-9 mbar l/s T Electropolished internals and case, internal surface finish Ra 0,25 µm Description Nominal size 1 1/8" Accuracy class Grade C according to ASME B40.1 Scale ranges - 30 inhg 60 psi - 30 inhg 130 psi Operating temperature Ambient: -10 + 60 C Medium: +60 C maximum Pressure connection Modular Surface Mount (MSM), C-seal Pressure element Inconel Dial White aluminium, with black lettering Pointer Black aluminium Case Material: stainless steel 316L, electropolished Window One piece polycarbonate WIKA Data Sheet PM 04.10 09/2006 Page 1 of 2 UHP Flow-Through-Gauge model 432.25.1 1/2" see data sheet PM 04.11 UHP Flow-Through-Gauge model 432.25.2" see data sheet PM 04.12-17-

Dimensions in mm Modular Surface Mount with C-seal Ordering information Pressure gauge model / Nominal size / Scale range Modifications may take place and materials specified may be replaced by others without prior notice. Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Page 2 of 2 WIKA Data Sheet PM 04.10 09/2006 09/2006 GB -18-

Mechanical Pressure Measurement UHP Flow-Through-Gauge Diaphragm Pressure Gauge, Nominal Size 1 1/2" Model 432.25 WIKA Data Sheet PM 04.11 Applications T Suitable for gaseous, liquid and corrosive media, also in a corrosive environment, for demanding high purity applications. T Semiconductor and flat panel industry T Gas distribution systems T Medical gases T Hook-up-application Special Features UHP Flow-Through-Gauge, Model 432.25.1 1/2" T No dead volume in the pressure gauge T Low internal volume for reducing particle generation and entrapment T Compact design T Helium leak tested, leak rate 10-9 mbar l/s T Electropolished internals and case, internal surface finish Ra 0,25 µm Description Nominal size 1 1/2" Accuracy class Grade C according to ASME B40.1 Scale ranges - 30 inhg 60 psi - 30 inhg 130 psi Operating temperature Ambient: -10 + 60 C Medium: +60 C maximum Pressure connection Fixed male 9/16-18 UNF Pressure element Inconel Dial White aluminium, with black lettering Pointer Black aluminium Case Material: stainless steel 316L, electropolished Window One piece polycarbonate WIKA Data Sheet PM 04.11 09/2006 Page 1 of 2 UHP Flow-Through-Gauge model 432.25.1 1/8" see data sheet PM 04.10 UHP Flow-Through-Gauge model 432.25.2" see data sheet PM 04.12-19-

Mounting position Horizontal mounting Vertical mounting Dimensions in mm Fixed male 9/16-18 UNF Ordering information Pressure gauge model / Nominal size / Scale range / Pressure connection / Mounting position Modifications may take place and materials specified may be replaced by others without prior notice. Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Page 2 of 2 WIKA Data Sheet PM 04.11 09/2006 09/2006 GB -20-

Mechanical Pressure Measurement UHP Flow-Through-Gauge Diaphragm Pressure Gauge, Nominal Size 2" Model 432.25 (FTG) WIKA Data Sheet PM 04.12 Applications T Suitable for gaseous, liquid and corrosive media, also in a corrosive environment, for demanding high purity applications. T Semiconductor and flat panel industry T Gas distribution systems T Medical gases T Hook-up-application Special Features UHP Flow-Through-Gauge, Model 432.25.2" (FTG) T No dead volume in the pressure gauge T Low internal volume for reducing particle generation and entrapment T Helium leak tested, leak rate 10-9 mbar l/s T Electropolished internals and case, internal surface finish Ra 0,25 µm T All high purity connections available Description Nominal size 2" Accuracy class Grade B according to ASME B40.1 accuracy higher on request Scale ranges -1 4 bar / -30 inhg... 60 psi -1 9 bar / -30 inhg... 130 psi Operating temperature Ambient: -10 + 60 C Medium: +60 C maximum Pressure connection All UHP connections available Pressure element Inconel Dial White aluminium, with black/red lettering, dual pressure scale (bar/psi) Pointer Black aluminium Case Material: stainless steel 316L, electropolished Window One piece polycarbonate screw-on WIKA Data Sheet PM 04.12 09/2006 Page 1 of 2 UHP Flow-Through-Gauge model 432.25.1 1/8" see data sheet PM 04.10 UHP Flow-Through-Gauge model 432.25.1 1/2" see data sheet PM 04.11-21-

Electronic Pressure Measurement Ultra High Purity Transducer, Non-Incendive Model NWU-10, Single End WIKA Data Sheet PE 87.10 Applications n Semiconductor and flat panel industry n Microelectronics engineering n Gas distribution systems (Gas sticks, gas panels, bulk-gas supply) n Ultra high purity water supply Special eatures n Classification II 3G EEx n A IIC T4 / T5 / T6 X n Thin-film sensor n Excellent long-term stability n No span adjustment required n Ingress protection IP 65 Description Explosion protection Generally Ex pressure transmitters are designed for applications which place high demands on pressure measuring instruments. These transmitters are an ideal solution for nearly all pressure measuring tasks in hazardous areas. Since the NWU-10 transmitters are classified as "non-incendive equipment" (zone 2, category 3G), there is no connection via IS line transformers or Zener barriers required. Universal As a result of its broad pressure range spectrum (vacuum up to 400 bar or 5000 psi respectively), its compact design and its excellent performance, model NWU-10 offers a perfect combination of an appealing design and proven measuring technology. Reliable Thin-film sensors produced by WIKA have ensured high accuracy, long-term stability in industrial ig. Transducer NWU-10 pressure measurement instrumentation for decades. Special thin-film sensors made of Elgiloy have been developed in order to meet the particular requirements of the ultra pure media industry. By hermetically welding the thin-film sensor, a total seperation of medium has been reached, as well as a longterm high impermeability which is required by the user. Versatile The modular design makes it possible to configure a high number of variants in order to comply with the manifold requirements of UHP applications. All wetted parts are electropolished using state-of-the art equipment prior to the final assembly. The high ingress protection (NEMA-4) allows operation even under the most difficult conditions. WIKA Data Sheet PE 87.10 10/2005 Page 1 of 4 Single End Model WU-10 see data sheet PE 87.01 low Through Transducer Model WU-15 see data sheet PE 87.02 MSM Transducer Model WU-16 see data sheet PE 87.03 Attachable indicator Model WUR-1 see data sheet PE 87.20-23-

Specifications Model NWU-10 Pressure ranges bar 4 7 10 16 25 40 60 100 160 250 400 psi 60 100 160 250 300 500 1000 1500 2000 3000 5000 Over pressure safety 1) bar 8 14 20 32 50 80 120 200 320 500 500 Burst pressure 1) bar 40 70 100 160 250 400 550 720 720 720 720 Measuring principle Materials n Wetted parts n Case 1) 1 bar = 14.50 psi Other pressure ranges and pressure units (e.g. MPa, kg/cm 2 ) on request Thin-film sensor 2.4711Elgiloy (Sensor); 316L VIM/VAR (Pressure connection) Stainless steel Surface finish Electropolished, typical Ra < 0.18 µm (RA 7); max. < Ra 0.25 µm (RA 10) Dead volume mm 3 < 1500 Permissible Medium Liquid / Gas / Vapour Power supply U B V DC 10 < U B < 24 Max. current output ma < 30 Response tine (10... 90 %) ms < 2 Dielectric strength DC V 500 Accuracy % of span < 0.25 for pressure ranges > 4 bar (BFSL) % of span < 0.5 for pressure ranges < 4 bar (BFSL) < 0.5 2) for pressure ranges > 4 bar < 1.0 2) for pressure ranges < 4 bar 2) Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). Adjusted in vertical mounting position with lower pressure connection. Non-linearity % of span < 0.15 for pressure ranges > 4 bar (BFSL) according to IEC 61298-2 % of span < 0.3 for pressure ranges < 4 bar (BFSL) according to IEC 61298-2 1-year stability % of span < 0.2 (at reference conditions) Adjustability zero % of span + 5 Permissible temperature range of n Medium -40... +100 C -40... +212 F n Ambience -20... +85 C -4... +185 F n Storage -40... +100 C -40... +212 F Compensated temperature range -20... +80 C -4... +176 F Temperature coefficients within compensated temperature range: n Mean TC of zero % of span < 0.3 / 10 K n Mean TC of range % of span < 0.15 / 10 K d-protection Signal Output Category 3G 4... 20 ma, 2-wire Ignition protection type EEx na IIC T4 X EEx na IIC T5 X EEx na IIC T6 X Conformity specifications n Power supply DC V 24 24 24 n Short circuit rating ma 30 30 30 n Power limitation W 1 1 1 n Medium temperature -20...+80 C -4...+176 F -20...+50 C -4...+122 F -20...+40 C -4...+104 F n Ambient temperature -20...+80 C -4...+176 F -20...+50 C -4...+122 F -20...40 C -4...+104 F n Storage temperature -40...+100 C -40...+212 F -40...+100 C -40...+212 F -40...100 C -40...+212 F n Internal capacity Ci nf 10 n Internal inductivity Li µh 10 For further safety information please see the operating instructions a -conformity 89/336/EWG interference emission and immunity see EN 61 326 Interference emission limit class A and B 97/23/EG Pressure equipment directive Shock resistance g 500 according to IEC 60068-2-27 (mechanical shock) Vibration resistance g 10 according to IEC 60068-2-6 (vibration under resonance) Wiring protection Mass kg Approx. 0.1 Protected against reverse polarity on the instrument side Page 2 of 4-24- WIKA Data Sheet PE 87.10 10/2005

Order-Code for Model NWU-10 Field No. Code Features Signal output 1 A 4... 20 ma, 2-wire Pressure range BCH -1 bar... 3 bar 1) BCT -1 bar... 6 bar BCL -1 bar... 9 bar BCP -1 bar... 15 bar BCQ -1 bar... 25 bar BCX -1 bar... 40 bar BCY -1 bar... 60 bar BC1-1 bar... 100 bar BC2-1 bar... 160 bar BC3-1 bar... 250 bar BBG 0 bar... 4 bar 1) BEF 0 bar... 7 bar BBI 0 bar... 10 bar BBK 0 bar... 16 bar BBL 0 bar... 25 bar BBM 0 bar... 40 bar BBN 0 bar... 60 bar BBO 0 bar... 100 bar BBP 0 bar... 160 bar BBQ 0 bar... 250 bar BBS 0 bar... 400 bar PCE -30 inhg... 45 psi 1) PCF -30 inhg... 60 psi 1) PCH -30 inhg... 100 psi PCK -30 inhg... 160 psi PCI -30 inhg... 250 psi PCM -30 inhg... 300 psi PCX -30 inhg... 500 psi PBE 0 psi... 60 psi 1) PBF 0 psi... 100 psi PBG 0 psi... 160 psi PDG 0 psi... 250 psi PBI 0 psi... 300 psi PDI 0 psi... 500 psi PBN 0 psi... 1000 psi PBO 0 psi... 1500 psi PBP 0 psi... 2000 psi PBQ 0 psi... 3000 psi PBS 0 psi... 5000 psi 2??? other Process connection VN 1/4" Weld Stub WH 1/4" Swivel Male Face Seal WI 1/4" Swivel Female Face Seal 71 Original VCR Swivel Male 72 Original VCR Swivel Female WT T-connector 3?? other Electrical connection M4 4-pin circular connector M12 x 1 O4 4-pin bayonet connector 4?? other Other UHP-Transducer Series NWU-1X ig. left: Transducer NWU-15 ig. right: Transducer NWU-16 urther information You can obtain further information (data sheets, instructions, etc.) via our internet address www.wika.de. 1) Accuracy 1.0 % of span Order code: 1 2 3 4 NWU-10 - - - - 7 B G Z Z Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. Page 4 of 4 WIKA Data Ssheet PE 87.10 10/2005 9077065 10/2005 GB -26-

Specifications Models WU-10, WU-15 and WU-16 Output signal and allowed load WU-16 WU-10 / WU-15 Pressure ranges bar 4 7 10 16 25 40 60 100 160 250 400 psi 60 100 160 250 300 500 1000 1500 2000 3000 5000 Over pressure safety 1) bar 8 14 20 32 50 80 120 200 320 500 500 Burst pressure 1) bar 40 70 100 160 250 400 550 720 720 720 720 Measuring principle Materials n Wetted parts n Case 1) 1 bar = 14.50 psi Other pressure ranges and pressure units (e.g. MPa, kg/cm 2 ) on request Metal thin film sensor 2.4711 (Elgiloy ) sensor; 316L VIM/VAR (Process connection) Stainless steel Surface finish Electropolished, typical Ra < 0.18 µm (RA 7); max. < Ra 0.25 µm (RA 10) Dead volume mm 3 WU-10 < 1500, WU-15 < 1000, WU-16 < 1000 Permissible Medium Liquid / Gas / Vapour Power supply U B DC V 10 < U B < 30 (14... 30 V with output signal 0.1... 10.1 V) Capacitive load µf Max. 0.1 (Voltage output) Max. current consumption ma < 1 Voltage output signal; Source ma < 30 Current output signal Adjustability zero % of span + 5 via potentiometer in the instrument Response time (10 90 %) ms < 2 Dielectric strength DC V 500 Accuracy % of span < 0.25 for pressure ranges > 4 bar (BFSL) % of span < 0.5 for pressure ranges < 4 bar (BFSL) % of span < 0.5 2) for pressure ranges > 4 bar % of span < 1.0 2) for pressure ranges < 4 bar 2) Including non-linearity, hysteresis, non-repeatability, zero point and full scale error (corresponds to error of measurement per IEC 61298-2). In vertical mounting position with lower pressure connection. Non-linearity % of span < 0.15 for pressure ranges > 4 bar (BFSL) according to IEC 61298-2 % of span < 0.3 for pressure ranges < 4 bar (BFSL) according to IEC 61298-2 1-year stability % of span < 0.2 (at reference conditions) Permissible temperature of n Medium -40... +100 C -40... +212 F n Ambience -20... +85 C -4... +185 F n Storage -40... +100 C -40... +212 F Compensated temp. range -20... +80 C -4... +176 F Temperature coefficients in compensated temperature range: n mean TC of zero % of span < 0.3 / 10 K n mean TC of range % of span < 0.15 / 10 K a -conformity 89/336/EWG Interference emission and immunity see EN 61 326, Interference emission limit class A and B, 97/23/EG Pressure equipment directive (Module H) Shock resistance g 500 according to IEC 60068-2-27 (mechanical shock) Vibration resistance g 10 according to IEC 60068-2-6 (vibration under resonance) Wiring protection Mass kg Approx. 0.1 4... 20 ma, 2-wire Protected against reverse polarity and short circuiting on the instrument side permitted range Output current (2-wire) 4... 20 ma: R A < (U B 10 V) / 0.02 A Output voltage (3-wire) 0.1... 5.1 V: R A > 5 kohm 0.1... 10.1 V: R A > 10 kohm with R A in Ohm and U B in DC V Page 2 of 6-28- WIKA Data Sheet PE 87.05 10/2005

Electronic Pressure Measurement Ultra High Purity Attachable indicator with LED Model WUR-1 WIKA Data sheet PE 87.20 Applications T Semiconductor and flat panel industry T Microelectronic Technology T Gas distribution systems (Gas sticks, gas panels, bulk-gas supply) Special features T Top View or Front View T Up to 2 Switch points freely programmable T Ingress Protection IP 65 T 5 different units manually adjustable Fig. left WUR-1, Top View Fig. right WUR-1, Front View Description Dynamic An unique solution for a local display of the process pressure offers the attachable indicator model WUR-1. With this especially for the UHP-Market designed indicator a signal and freely adjustable switch points can be transmitted simultaneously. Due to its universal programmability and simple mounting the attachable indicator can also be easily installed on pressure transmitters which are already in use. Its scale can be fully adjusted directly on site without master instrument. Comfortable Power is directly supplied by the 4... 20 ma-loop, i.e. no extra power supply is required. Practical The seven millimetre high, red LED display is easy to read. In order to be able to adapt the indicator to the application, it is available in two different versions; Front View (connection to the transmitter at the bottom) or Top View (connection to the transmitter at the back). Unit (psi, bar, kpa, MPa and kg/cm²), decimal point, display range, zero point and switch points can be adjusted via the control keys. WIKA Data sheet PE 87.20 09/2002 Page 1 of 4 UHP-Transducer, Single End Model WUS-10 see data sheet PE 87.01 UHP-Transducer, Flow Through Model WUS-15 see data sheet PE 87.02 UHP-Transducer, Modular Surface Mount Model WUS-16 see data sheet PE 87.03-33-

Specifications Model WUR-1 Display T Design 7-Segment-red LED, height 7 mm, 4-digit T Range -999... 6000 T Accuracy % of span < +0.5 +1 digit Scaling adjustment Menu-driven programming via external control keys Adjustable measuring range Adjustable decimal point Programmable pressure units: bar, psi, kg/cm², MPa, kpa Zero point freely adjustable within a range of +10 % of the span Signal input ma 4... 20, 2-wire (supplied by the current loop, 6 V voltage load) V 0.1... 5.1, 3-wire / 0.1... 10.1, 3-wire Signal output Analogue signal is directly looped through (4... 20 ma or 0.1... 10.1 V or 0.1... 5.1 V) Max. permissible input ma / VDC +40 (short-time) a -conformity Interference emission and Interference compatibility see EN 61 326 For cable lengths of > 30 m (current) resp. >3 m (voltage) shielded cables must be used Switch points Individually adjustable via external control keys T Number 2 x NPN Open-Collector (potential-free) {MIL-connector: 1 x NPN Open-Collector} galvanically isolated switch points at 4... 20 ma T Function Normally open / Normally closed T Adjustment Freely adjustable within a range of 1... 99 % of the span T Temperature error < 0.1% / 10 K T Accuracy % of span < +0.5 +1 digit T Max.switching current ma 300 (None-inductive) T Display of switch status LED T Response time (10... 90 %) ms < 15 T Hysteresis % 0.5 (fixed) Power supply VDC 16... 30 at 4... 20 ma; 15... 30 at 0.1... 10.1 V 10... 30 at 0.1... 5.1 V Influence of power supply < 0.1% / 10 V Permissible temperature range T Ambient C - 30... +85-22... +185 F T Storage C - 30... +85-22... +185 F T Compensated C - 20... +80-4... +176 F Temperature error % of span < 0.1/10K Vibration resistance g 5 at 10... 2000 Hz Shock resistance g 100 Electrical connection T Input Circular connector (female) M 12x1, 4-pin {MIL connector (female), 4-pin} T Output Circular connector M 12x1, 5 pin {MIL connector, 4-pin or flying lead} Ingress protection per IEC 60529 / EN 60529 IP 65 Wiring protection Protected against polarity crossing +U B/0V Materials case T Case ABS Position of the electrical connection Front View (connection to the transmitter at the bottom) or Top View (connection to the transmitter at the back) Weight g 50 { } Items in curved brackets are optional extras for additional price. Page 2 of 4-34- WIKA Data sheet PE 87.20 09/2002

Dimensions in inch [mm] ront View (connection to the transducer at the bottom) Circular connector M 12x1, 5-pin lying leads MIL-connecetor, 4-pin Circular connector (female) M 12x1, 4-pin MIL-connector (female), 4-pin Top View (connection of the transducer at the back) Circular connector M 12x1, 5-pin Circular connector (female) M 12x1, 4-pin lying leads MIL-connector, 4-pin MIL-connector (female), 4-pin WIKA Data sheet PE 87.20 09/2002-35- Page 3 of 4

Wiring details Connector- Pin 2-wire Execution current 3-wire Execution voltage Circular connector M 12x1, 5-pin 1 Power supply +UB, S+ Power supply +UB Flying leads MIL-connector, 4-pin 2 Switch out1 Switch out1 3 Power supply 0V, S- Power supply 0V, Switch ground, S- 4 Switch ground (potential-free) Signal S+ 5 Switch out2 Switch out2 red Power supply +UB, S+ Power supply +UB black Power supply 0V, S- Power supply 0V, Switch ground, S- yellow Switch ground (potential-free) Signal S+ brown Switch out1 Switch out1 orange Switch out2 Switch out2 A Power supply +UB, S+ Power supply +UB B Switch ground (potential-free) Signal S+ C Switch out1 Switch out1 D Power supply 0V, S- Power supply 0V, Switch ground, S- Output Input Fig. : WUR-1 Front View Fig. : WUR-1 Top View Connector- Pin 2-wire Execution current Circular connector (female) M 12x1, 4-pin MIL-connector (female), 4-pin 3-wire Execution voltage 1 Power supply +UB, S+ Power supply +UB 2 -- -- 3 Power supply 0V, S- Power supply 0V, S- 4 -- Signal S+ A Power supply +UB, S+ Power supply +UB B -- Signal S+ C -- -- D Power supply 0V, S- Power supply 0V, S- Modifications may take place and materials specified may be replaced by others without prior notice. Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Page 4 of 4 WIKA Data sheet PE 87.20 09/2002 XXXXXXX 09/2002 GB -36-

Electronic Pressure Measurement Ultra High Purity Attachable indicator with LED, Non-Incendive Model NWUR-1 WIKA Data Sheet PE 87.21 Applications n Semiconductor and flat panel industry n Microelectronic Technology n Gas distribution systems (Gas sticks, gas panels, bulk-gas supply) Special features n Classification II 3G EEx n A IIC T6 X n Top View or ront View n Up to 2 Switch points freely programmable n Ingress Protection IP 65 n 5 different units manually adjustable ig. left NWUR-1, Top View ig. right NWUR-1, ront View Description Explosion protection The attachable indicator NWUR-1 is among increased safety requirements, an unique solution for a local display of the process pressure. Dynamic With this indicator a signal and freely adjustable switch points can be transmitted simultaneously. Due to its universal programmability and simple mounting the attachable indicator can also be easily installed on pressure transmitters which are already in use. Its scale can be fully adjusted directly on site without master instrument. Comfortable The power is directly supplied, i.e. no extra power supply is required. Practical The seven millimetre high, red LED display is easy to read. In order to be able to adapt the indicator to the application, it is available in two different versions; ront View (connection to the transmitter at the bottom) or Top View (connection to the transmitter at the back). Unit (psi, bar, kpa, MPa and kg/cm²), decimal point, display range, zero point and switch points can be adjusted via the control keys. WIKA Data Sheet PE 87.21 11/2003 Page 1 of 4 UHP-Transducer, Non-Incendive Model NWU-10 see data sheet PE 87.10-37-

Specifications Model NWUR-1 Display n Design 7-Segment-red LED, height 7 mm, 4-digit n Range -999... 6000 n Accuracy % of span < 0.5 +1 digit Scaling adjustment Menu-driven programming via external control keys Material Case ABS Adjustable measuring range Adjustable decimal point Power supply DC V 16 < U B < 30 V Influence of power supply % < 0.1 / 10 V Programmable pressure units: bar, psi, kg/cm², MPa, kpa Zero point freely adjustable within a range of +10 % of the span Signal input ma 4... 20, 2-wire (supplied by the current loop, 6 V voltage load) Signal output Analogue signal is directly looped through Max. permissible input ma +40 (short-time) Switch points Individually adjustable via external control keys n Number 2 x NPN Open-Collector (potential-free) {MIL-connector: 1 x NPN Open-Collector} galvanically isolated switch points n Function Normally open / Normally closed n Adjustment Freely adjustable within a range of 1... 99 % of the span n Temperature error % < 0.1 / 10 K n Accuracy % of span < 0.5 +1 digit n Max. switching current ma 300 (non-inductive) n Display of switch status LED n Response time (10... 90 %) ms < 15 n Hysteresis % of span 0.5 (fixed) Permissible temperature range n Ambient 1) - 30... +85 C -22... +185 F n Storage 1) - 30... +85 C -22... +185 F Temperature error % of span < 0.1 / 10 K a -conformity Interference emission and immunity see EN 61 326 For cable lengths of > 30 m shielded cables must be used Shock resistance g 100 according to IEC 60068-2-27 (mechanical shock) Vibration resistance g 5 at 10... 2000 Hz according to IEC 60068-2-6 (vibration under resonance) Wiring protection Protected against reverse polarity +U B /0V Ingress protection per IP 65 (per IEC 60529 / EN 60529) d-protection Category 3G Ignition protection type EEx na IIC T6 X Conformity specifications n Power supply DC V 30 n Short circuit rating ma 40 n Power limitation W 0,4 n Ambient temperature C -20... +60 n Storage temperature C -30... +80 n Internal capacity Ci nf 22 n Internal inductivity Li µh 0 For further safety information please see the operating instructions Position of the electrical connection Front View (connection to the transmitter at the bottom) or Weight g 50 Top View (connection to the transmitter at the back) 1) Limitations regarding d-protection, please refer to Conformity specifications. Page 2 of 4-38- WIKA Data sheet PE 87.21 11/2003

Accessories Digital Indicator for Panel Mounting Dimensions 96 x 96 x 71 mm Model DI30 WIKA Data Sheet AC 80.05 Applications Plant construction Machine tools Test benches Level measurement General industrial applications Special Features Input free selectable 4... 20 ma, 0... 20 ma, 0... 5 V, 0... 10 V Integradet power supply DC 24 V for the transmitter Min. / max. value storage 2 fully programmable alarm outputs Linearisation with up to 10 points possible Digital Indicator Model DI30 Description The digital indicator DI30 has been specially designed to display values measured by electronic transmitters, such as pressure transmitters or temperature transmitters. Different input configurations for standard signals 0/4... 20 ma, 0... 5 V and 0... 10 V, are available, which can be selected via the terminal configuration and by the selection of the input signal in the instrument configuration. Thereby alternatively transmitters with current or voltage signals can be connected to the same unit. By means of the transmitter supply current loop transmitters (2-wire) as well as 3-wire and 4-wire transmitters can be operated. The transmitter supply is galvanically isolated from the measuring input. There are two alarm outputs available. In addition the indicator offers the possibility of sensor calibration and linearisation with up to 10 points, thus enabling a further adaptation to many different sensor signals and specific application requirements. The standard features are completed by the adjustable sampling rate and display time as well as the input offset for the correction of zero offsets or sensor drifts. Unauthorised changes of the set instrument parameters can be prevented by a user-definable code on different user levels. All the configuring and programming can be done using the front control keys. WIKA Data Sheet AC 80.05 10/2005 Page 1 of 4-41-

Specification Model DI30 Display - Principle 7-segment LED - Display 4-digit, red - Height of digits 20 mm - Indication range -999... 9999 - Indication time 0.1... 10.0 s Scaling adjustment by single program numbers initial value and final value free adjustable between -1999 and +1999 adjustable decimal point Input - Number and type 1 input for standard signal - Input signal 4... 20 ma, input resistance 100 Ω or 0... 20 ma, input resistance 100 Ω or 0... 5 V, input resistance 150 kω or 0... 10 V, input resistance 150 kω - Input configuration selectable via terminal configuration and programming - Accuracy ± 0.1 % of span ± 1 digit - Measuring time 0.1... 10.0 s Alarm outputs - Number and type 2 switching contacts (relay), fully programmable - Relay contact load: AC 230 V, 5 A (resistive load), DC 30 V, 2 A (inductive load cos ϕ = 1) Memory parameter memory EEPROM - Data preservation > 20 Years Transmitter supply DC 24 V, max. 50 ma, galvanically isolated Power supply AC 230 V, 50/60 Hz, ±10 % - Power consumption max. 8 VA Electrical connection detachable screw terminal - Wire cross section 2.5 mm 2 Permissible ambient temperature - Working temperature 0... 60 C - Storage temperature -20... +80 C - Humidity relative humidity 75 %, non-condensing CE-conformity conformity in accordance with 89/336/EWG interference emission and interference compatibility see EN 61 326 Safety regulations DIN 61 010 Case - Material aluminium - Colour black - Ingress protection front: IP 54; back: IP 00 (per IEC 60 529 / EN 60 529) - Mass approx. 530 g - Mounting grid horizontal 120 mm / vertical 120 mm (recommended) - Mounting suspensible mounting element, fixed over screws for a wall thickness from 1 mm up to 10 mm Page 2 or 4-42- WIKA Data Sheet AC 80.05 10/2005

Indication and operating elements 1 Program key [ P ] 2 Down key [ ] 3 Up key [ ] 4 Alarm indication (alarm 1 and alarm 2) 5 7-segment display 1 2 3 4 5 Terminal arrangement 9-pole terminal block Screw terminal for power supply and alarm contacts 1 2 alarm contact 2 3 4 AC 230 V 50/60 Hz (connection L) 5 ground wire (connection PE) 6 AC 230 V 50/60 Hz (connection N) 5-pole terminal block Screw terminal for input signal and transmitter supply 10 + I-in, measuring signal current 11 + U-in, measuring signal voltage 12 - I-in, measuring signal current - U-in, measuring signal voltage 13 - GND, ground for transmitter supply 14 +24 V, transmitter supply 7 8 alarm contact 1 9 WIKA Data Sheet AC 80.05 10/2005-43- Page 3 of 4

Dimensions HYDRA - line, Model HG, in-line flare process connection 2442 405.01 HYDRA - line, Model HG, in-line flare process connection 2442 413.01 Process connection Dimensions [mm] H L L1 F B1 B2 Ød2 in-line 3/8" flare 156 118 127 16 40 62 5.5 in-line 1/2" flare 156 122 133 16 40 62 5.5 in-line 3/4" flare 162 122 133 19 40 62 5.5 in-line 1" flare 186.5 165 179 25 56 78 6.5 in-line 1 1/4 " flare 186.5 224 238 25 56 78 6.5 Considerations for use: This gauge can be rotated a full 360 by hand. No tools required. The gauge can not be removed or the central PVDF nut loosened from the housing as this may cause the fill fluid to leak destroying the measuring unit. 2-46-

SP 99.21 HYDRA - line Pressure Systems Ultra High Purity Pressure Transducer Perfluoroalkoxy (PFA) Wetted Parts Stainless Steel Pressure Measurement Devices Hydra Sensor Model HS Application Liquid media for ultra high purity liquid distribution systems that require high degrees of accuracy, ultra clean wetted surfaces, and a high degree of chemical resistance. Process connection In-Line 3/8, 1/2, 3/4, 1 and 1 1/4 flare dead-end 1/4, 3/8 and 1/2 flare, panel mount, dead-end 1/4 NPT female Pressure measurement device Transmitter 4... 20 ma, 2-wire system (with attachable indicator as an option) according to data sheets PE 81.01 and PE 82.11 Transmitter has 360 orientation even after installation. Pressure ranges 0... 2.5 bar 0... 4 bar 0... 6 bar or other equivalent units Overpressure limit Maximum process pressure is limited by pressure-temperature rating of the process connection (see diagram page 3) Operating temperature Ambient: +5... +60 C Media: +5... +60 C Storage: -20... +60 C HYDRA - line, Model HS Transmitter 4... 20 ma, 2-wire system and in-line 1/2 flare process connection Accuracy ± 0.5 % of span Temperature offset Additional error when temperature changes from reference temperature of 20 C ±0.25 % of span for every 10 C rising or falling Electrical connection 4-pin L-plug per DIN 43 650 (IP 65) Material Wetted parts: PFA or TFM (modified PTFE) Other non-wetted parts: PVDF, EPDM, Viton Transmitter: Stainless steel Diaphragm Vented three Layer Diaphragm Assembly Filling liquid (Precision filled and not field refillable) 50/50 Mix Semiconductor Grade IPA (Isopropyl Alcohol) / DI Water (KN 75) Cleaning and packaging Production of all wetted parts, cleaning, assembly, calibration and packaging are done in a class 100 cleanroom. The offer for sale of this product does not infer or imply chemical compatibility with specific applications. Supplementary data sheets n Hydra Gauge (see data sheet SP 99.20) n Hydra Dry (see data sheet SP 99.22) HYDRA - line, Model HS Transmitter 4... 20 ma, 2-wire system, process connection dead-end 1/2 flare Model HG Model HD -49-

Dimensions HYDRA - line, Model HS, in-line flare process connection 2332 340.02 Process connection Dimensions [mm] H 1 L L 1 F 1 B1 B2 Ød2 in-line 3/8" flare 167 118 127 16 40 62 5.5 in-line 1/2" flare 167 122 133 16 40 62 5.5 in-line 3/4" flare 172 122 133 19 40 62 5.5 in-line 1" flare 197 165 179 25 56 78 6.5 in-line 1 1/4" flare 197 224 238 25 56 78 6.5 HYDRA - line, Model HS, dead-end process connection 2436 439.01 2436 502.01 Process connection Dimensions [mm] H1 SW1 SW2 ØD2 dead-end 1/4" flare 205 ± 2 27 11/16 " 64 dead-end 3/8" flare 205 ± 2 27 15/16 " 64 dead-end 1/2" flare 208 ± 2 27 17/16 " 64 dead-end 1/4 NPT female 161 ± 2 27-64 2-50-

Ordering information for pressure system HYDRA - line, Model HS Field No. Code Features Unit B bar P psi A kpa 1? other Please state as additional text Range 1) BF 0 bar... 2.5 bar 0 psi... 30 psi 0 kpa... 250 kpa BG 0 bar... 4 bar 0 psi... 60 psi 0 kpa... 400 kpa BH 0 bar... 6 bar 0 psi... 100 psi 0 kpa... 600 kpa 2?? other Electrical connection 3 A 4-pin L-plug DIN 43 650, IP 65 Didital display Z without 4 L LCD, 4-digit, see data sheet PE 82.11 Only available with electrical connection L-plug Process connection 06 In-line 3/8 " flare 08 In-line 1/2 " flare 12 In-line 3/4 " flare 16 In-line 1 " flare 20 In-line 1 1/4 " flare 38 dead-end 1/4 " flare 40 dead-end 3/8 " flare 42 dead-end 1/2 " flare 5 50 dead-end 1/4 NPT female Flare nut 77 PFA Only for flare connections, not for NPT 75 PVDF Only for flare connections, not for NPT 6 ZZ without Only with NPT connections Fill fluid 7 L1 KN 75 iso-propyl-alcohol (IPA) / DI-water 50:50 Additional order info YES NO 8 1 Z additional text Please state in clearly understandable text! Order code for Model HS 1 2 3 4 5 6 7 8 HS - A L1 Additional text: Optional designs on request Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. 9017046 07/2004 GB -52-

SP 99.22 HYDRA - line Pressure Systems Ultra High Purity Pressure Transducer Perfluoroalkoxy (PFA) Wetted Parts Dry Ceramic Sensor Hydra Dry Model HD Application Pressure measurement of liquid fluid media for ultra high purity liquid distribution systems. High accuracy and reliability, ultra clean wetted parts and surfaces in contact with media and good chemical resistance are required for optimum performance. Process connection In-Line 3/8, 1/2, 3/4, 1 and 1 1/4 flare dead-end 1/4, 3/8 and 1/2 flare, panel mount, dead-end 1/4 NPT female Signal output 4... 20 ma, 2-wire system Power supply DC 24 V (DC 12... 30 V supply voltage) Accuracy ± 0.5% of span for precise and reliable process control (includes combined effects of hysteresis and linearity) Pressure ranges 0... 2.5 bar (0... 30 psi) 0... 4 bar (0... 60 psi) 0... 6 bar (0... 100 psi) or other equivalent units Overpressure limit Maximum process pressure is limited by pressure-temperature rating of the process connection (see diagram page 3) Operating temperature Ambient: +5... +60 C Media: +5... +80 C Storage: -20... +60 C Electrical connection 5 m flying lead (IP 67) Material Wetted parts: PFA or TFM (modified PTFE) Other non-wetted parts: PVDF, EPDM, FPM/FKM Cable: FEP jacketed Sensing element Non-metallic ultra-pure-ceramic sensor isolated from process media by vented three layer PFA diaphragm assembly (approved and patented Hydra-technology) thus providing improved protection from diffusion. Fill fluid No fill fluid which avoids possible process contamination Cleaning and packaging Production of all wetted parts, cleaning, assembly, calibration and packaging are done in a class 100 cleanroom. The offer for sale of this product does not infer or imply chemical compatibility with specific applications. HYDRA - line, Model HD In-line 1/2 flare process connection 5 m flying lead Supplementary data sheets n Hydra Gauge (see data sheet SP 99.20) n Hydra Sensor (see data sheet SP 99.21) n Hydra Indicator (see data sheet SP 99.23) HYDRA - line, Model HD dead-end 1/2 flare process connection 5 m flying lead Model HG Model HS Model HI -53-

Ordering information for pressure system HYDRA - line, Model HD Field No. Code Features Unit B bar P psi A kpa 1? other Please state as additional text Range 1) BF 0 bar... 2.5 bar 0 psi... 30 psi 0 kpa... 250 kpa BG 0 bar... 4 bar 0 psi... 60 psi 0 kpa... 400 kpa BH 0 bar... 6 bar 0 psi... 100 psi 0 kpa... 600 kpa 2?? other Please state as additional text Electrical connection 3 H 5 m flying leads with free ends (IP 67, FEP jacketed) Digital indicator Z without 2 integrated 4 digit LED, model HI, see data sheet SP 99.23 4 3 separate for panel mount, 4 digit LED, model HI, see data sheet SP 99.23 Process connection 06 In-line 3/8 " flare 08 In-line 1/2 " flare 12 In-line 3/4 " flare 16 In-line 1 " flare 20 In-line 1 1/4 " flare 38 dead-end 1/4 " flare 40 dead-end 3/8 " flare 42 dead-end 1/2 " flare 5 50 dead-end 1/4 NPT female Flare nut 77 PFA Only for flare connections, not for NPT 75 PVDF Only for flare connections, not for NPT 6 ZZ without Only with NPT connections Additional order info YES NO 7 1 Z additional text Please state in clearly understandable text! Order code for Model HD 1 2 3 4 5 6 7 HD - H Additional text: Optional designs on request Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. 12/2006 GB -56-

Technical data Model HI, HYDRA-Indicator Display T Design T Range -999... 6000 T Accuracy % of span < 0.5 ±1 digit Scaling adjustment 7-Segment-red LED, height 7 mm, 4-digit Menu-driven programming via external control keys Adjustable measuring range einstellbar Adjustable decimal point Programmable pressure units: bar, psi, kg/cm², MPa, kpa Zero point freely adjustable witin a range of ±10 % of the span Signal input ma 4... 20, 2-wire (supplied by the current loop, 6 V voltage load) Signal output Analogue signal is directly looped through Max. permissible input ma / VDC ±40 (short duration only) CE-conformity 89/336/EWG interference emission and Interference compatibility see EN 61 326 Switch points T Number T Function T Adjustment T Temperature error T Accuracy % of span < 0.5 ±1 digit T Max. switching current ma 300 T Display of switch status Individually adjustable via external control keys 2 x NPN Open-Collector galvanically isolated Make contact, break contact Freely adjustable within a range of 1... 99 % of the span < 0.1% / 10 K LED T Response time ms < 15 T Hysteresis % 0.5 (fixed) Power supply U B VDC 16... 30 Influence of power supply Permissible temperature range < 0.1% / 10 V T Ambient C - 30... +85 T Storage C - 30... +85 T Compensated C - 20... +80 Temperature error % of span < 0.1/10K Vibration resistance g 5 at 10... 2000 Hz Shock resistance g 100 Electrical connection Ingress protection per IEC 60 529 / EN 60 529 IP 67 Wiring protection Materials T Case T Cable Installation Flying lead with 5 m cable Protected against polarity crossing +U B/0V PP and PFA Coated with PTFE Panel mount Ø 69.5 mm or mounted on pressure transducer HYDRA-Dry { } Items in curved brackets { } are optional extras for additional price. Page 2 of 4-58- WIKA Data Sheet SP 99.23 09/2005

Dimensions in mm Integrated HYDRA-Indicator HYDRA-Indicator panel-mount 2479113.01 2480187.01 WIKA Data Sheet SP 99.23 09/2005-59- Page 3 of 4

Electrical connection Flying leads red Power supply +UB, S+ black Power supply 0V, S- blue Not wired white Switch ground (potential-free) brown Switch out1 yellow Switch out2 Example for connection programmable logic controller (PLC) HYDRA-Dry red black HYDRA-Indicator red brouwn yellow white black Modifications may take place and materials specified may be replaced by others without prior notice. Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Page 4 of 4 WIKA Data Sheet SP 99.23 09/2005 9067159 01/2003 GB -60-

SP 99.25 Pressure Systems Pressure Gauge with mounted Diaphragm Seal for Ultra High Purity Industry Model 232.35 with Model 990.80 Application Pressure measurement in liquid fluid media for semiconductor and other ultra high purity applications that require isolation of the pressure indication device from the media flow. Isolation may be required due to abrasive or pure media that requires electropolished surfaces. Typical applications are solvent delivery and recovery systems and chemical mechanical polishing applications. Design Pressure gauge mounted directly to diaphragm seal. Diaphragm seal upper housing welded with lower housing. Pressure rating 70 bar resp. 1000 psi Operating temperature 4 C... 60 C (40 F to 140 F) Process connection (diaphragm seal) ¼" FFFS (fixed female face seal) wetted parts material: stainless steel 316 L, electropolished Filling liquid 50/50 Mix Semiconductor Grade IPA (Isopropyl Alcohol) / DI Water (KN 75) Standard features (pressure gauge) Recomended bourdon tube pressuer gauge Model 232.35 Nominal size 63 mm (2½") Accuracy 2/1/2% of span (ASME B 40.1 Grade A) in compliance with accuracy class 1.6 per EN 837-1 /6 Scale ranges 0... 1 to 0... 70 bar (EN 837-1 /5) 0... 15 to 0... 1000 psi (ASME B 40.1) or other equivalent units of pressure or vacuum Movement Stainless steel Dial White aluminium, with pointer stop pin, with black lettering Pressure gauge Model 232.35 with mounted diaphragm seal Model 990.80 Optional extras - Process connection ¼ NPT female - Special material Hastelloy C 276 - Alarm contacts for gauge Inductive contact (Model 831) - Dial for gauge dual pressure scale (psi/bar) with black/red lettering Pointer Black aluminium pointer Case Stainless steel, with solid baffle wall (solid front) and blow-out back Window Laminated safety glass Bezel ring Cam ring (bayonet type), stainless steel To determine the effects of temperature and response time in a specific application, contact the factory for an Application Questionnaire. The information provided will allow WIKA Technical Supportto accurately model your application parameters using state-of-the-art computer simulation techniques. -61-

Dimensions Standard version Process connection Dimensions [mm] Weight [kg] G D 1 D 2 h 1 h 2 SW ¼" FFFS 63 40 55 129 36 approx. 0.7 ¼" NPT female 63 40 51 125 36 approx. 0.6 Ordering information State: Pressure gauge model / Nominal size / Scale range / Diaphragm seal model / Process connection / Filling liquid / Optional extras required Specifications and dimensions given in this leaflet represent the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. 09.03-62-

Accessories Gas Cylinder Scale WIKA Data Sheet AC 09.13 Applications n Weighing gas cylinders in gas cabinets and gas distribution systems n Chemical delivery systems n acility maintenance Special eatures n High overload protection up to 400 % n 0.1 % S Accuracy n Excellent EMI and R I immunity n Scale ranges 0... 60 lbs to 0... 300 lbs n High ingress protection NEMA 4 (IP 65) for processing with high condensation and outdoor use. ig. Gas Cylinder Scale Description Digital indicators The WIKA Gas Cylinder Scale is designed for liquid gas weighing applications by in and outdoor use in gascabinetts or gascontainers with corrosive environments. Condensate on the gascylinders will not be a problem anymore because of the high ingress protection. A carefully designed robust construction, accurate and reliable measurement of the weight maintain the high standards of the Semiconductor gas distribution processes. ig. digital indicator panel mounting Model DI30 see Data Sheet AC 80.05 EMI and R I protection meets highest standards to guarantee a error free accure operation. The high overload protection and heavy gauge stainless steel component parts secure the maintenance-free performance in industry-grade applications. ig. digital indicator wall mounting Model DI30 see Data Sheet AC 80.05 WIKA Data Sheet AC 09.13 01/2007 Page 1 of 2-63-