D u m m y Specification sheet Client Project name Order# Type Qty Side view Bottom view Photometric Summary Description The Lumenalpha Soft Nano Tilt is a high-performance LED downlight for accenting and general lighting. Designed with a deep-set, soft reflector, the luminaire provides enhanced glare control and leading performance (up to 3000 lumens from a 2- inch optical aperture). The luminaire offers a choice of outputs, beam angles, colour temperatures, colour rendering options and accessories. Features Optics Output (nominal lumens) Colour and colour temperature 700 lm, 1000 lm, 1300 lm, 2000 lm, 3000 lm 2200K, 2700K, 3000K, 3500K, 4000K Optics (nominal distribution) Narrow spot 10, Narrow 20, Medium 40 Control Rating Installation type Accessories Warranty Performance Maximum delivered output Maximum delivered intensity Efficacy Colour consistency Remodel non-insulated ceiling, New construction non-insulated ceiling, New construction insulated ceiling, New construction insulated ceiling - Chicago plenum rated option (airtight) Softening glass lens, Honeycomb louvre, Clear glass lens, Linear spread glass lens 5-year limited warranty Up to 1,565 lm Up to 8,746 cd Up to 68 lm/w 2 SDCM Colour rendering CRI 80+/CRI 95+ Lumen maintenance L95 55,000 hrs (Ta 40 C), L70 225,000 hrs (Ta 40 C) 1 / 13
Physical Housing material TIR optics material Reflector material Trim shape Interior finish Trim finish Adjustability Aluminium Clear polycarbonate (narrow spot and narrow optics) Aluminium (medium and wide optics) Round, Square Silver, Black, Custom (please specify RAL colour) White, Black, Nickel satin Fixed tilt 30 (factory set) Electrical and control Voltage 120 volts, 277 volts Control On/off control, 0-10V (1% linear or logarithmic), Pro 0-10V (0.1% linear or logarithmic), DALI (0.1% linear or logarithmic), Lumentalk, Phase dimming (consult factory) Environmental Environment Damp location rating (interior applications only) Operating temperature -4 F to 104 F IP Rating IP44 (with NS/N optics), IP44 (with M optics, CL/SL/RS accessories), IP20 (with M optics without accessories) 2 / 13
Dimensions NS(10 ) N(20 ) M(40 ) 3 / 13
Photometric information Non-insulated ceiling installation types (RM and NC) Narrow Spot (nominal 10 ), 4000K, RD trim shape 1, 2 Narrow (nominal 20 ), 4000K, RD trim shape Medium (nominal 40 ), 4000K, RD trim shape 1Remove 2 watts per fixture when specifying new construction insulated ceiling installation types (IC and CP). 2Add 3 watts per fixture when specifying Lumentalk. Delivered wattage: +/- 10% tolerance. Preliminary, consult website for latest ies files. Delivered output: +/- 10% tolerance. *Photometric performance is measured in compliance with IESNA LM-79-08. 4 / 13
Photometric information Colour rendering options comparison, 3000K Control Ceiling Requirements Minimum Ceiling Height A- Round trim ceiling cutout: Ø 2 7/8 in B- Square trim ceiling cutout : 2 13/16 in x 2 13/16 in C-Maximum ceiling thickness: 1 1/2 in 5 / 13
Installation type Remodel non-insulated ceiling - on/off control Remodel non-insulated ceiling - dimming LASN-MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-NO-RM A - Available knockout holes. B - Internal wire gauge: 18 AWG LASN-MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-DIMMING-RM A - Available knockout holes. B - Internal wire gauge: 18 AWG New construction non-insulated ceiling - on/off control New construction non-insulated ceiling - dimming LASN-MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-NO-NC A - DRIVER BOX-NO B - Available knockout holes. C - Internal wire gauge: 18 AWG LASN-MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-DIMMING-NC A - DRIVER BOX-DIMMING B - Available knockout holes. C - Internal wire gauge: 18 AWG 6 / 13
New construction insulated ceiling, Chicago plenum rated option, airtight LASN-MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-CONTROL-IC/CP A - Available knockout holes. B - Internal wire gauge: 18 AWG C - Available for output and colour rendering combinations LASN-MTG-A-VOLTAGE-OUTPUT-COLOUR RENDERING-CONTROL-IC/CP A - Available knockout holes. B - Internal wire gauge: 18 AWG C -*Available for output and colour rendering combinations 7 / 13
Wiring Details RM: remodel non-insulated ceiling and NC: new construction non-insulated ceiling On/off Control A - Conduit (by others) B - Power Input C - Optional Output D - Conduit fitting (by others) E - Locknut (by others) F - Ground (green) G - Line (black) H - Neutral (white) I - Thermal protector J - Output to luminaire Control (DA1, DA2, PDA1, PDA2, DALI1, DALI2) A - Conduit fitting (by others) B - Conduit (by others) C - Power Input D - Data Input from Control System E - Locknut (by others) F - Neutral (white) G - Line (black) H - Ground (green) I - Data - (grey) J - Data + (purple) K - Thermal protector L- Output to luminaire Control (Daisy Chain Layout) (DA1, DA2, PDA1, PDA2, DALI1, DALI2) A - Conduit (by others) B - Power Output to next luminaire C - Power Input D - Data Output to next luminaire E - Data Input from Control System F - Locknut (by others) G - Duplex connector (by others) H - Neutral (white) I - Line (black) J - Ground (green) K - Data - (grey) L - Data + (purple) M - Thermal protector N - Output to luminaire 8 / 13
Wiring details RM: remodel non-insulated ceiling Lumentalk dimming Control (LT) A - Conduit fitting (by others) B - Conduit (by others) C - Power Input D - Locknut (by others) E - Ground (green) F - Neutral (white) G - Line (black) H - Thermal protector I - Output to luminaire Control (Daisy Chain Layout) (LT) A - Conduit fitting (by others) B - Conduit (by others) C - Power Input D - Power Output to next luminaire E - Locknut (by others) F - Ground (green) G - Neutral (white) H - Line (black) I - Thermal protector J - Output to luminaire 9/ 13
Wiring details IC/CP: new construction insulated ceiling On/off Control A - Locknut (by others) B - Conduit fitting (by others) C - Conduit (by others) D - Power Input E - Line (black) F - Output to luminaire G - Neutral (white) H - Ground (copper) I - Optional Output Control (DA1, DA2, PDA1, PDA2, DALI1, DALI2) A - Locknut (by others) B - Conduit fitting (by others) C - Conduit (by others) D - Power Input E - Line (black) F - Output to luminaire G - Neutral (white) H - Ground (copper) I - Data Input from Control System J - Data - (grey) K - Data + (purple) Control (Daisy Chain Layout) (DA1, DA2, PDA1, PDA2, DALI1, DALI2) A - Locknut (by others) B - Duplex connector (by others) C - Conduit (by others) D - Power Input E - Power Output (to next luminaire) F - Line (black) G - Output to luminaire H - Neutral (white) I - Ground (copper) J - Data Input from Control System K - Data Output (to next luminaire) L - Data - (grey) M - Data + (purple) 10/ 13
Accessories Softening glass lens Honeycomb louvre Clear glass lens Linear spread glass lens 11/ 13
How to order 1 2 3 4 5 6 7 8 9 10 11 12 13 1. Housing 2. Certification Lumenalpha Downlight Soft Nano Tilt A UL/cUL 3. Voltage (1) 4. Output (nominal lumens) 120 120 volts L07 700 lm 277 277 volts L10 1000 lm L13 1300 lm L20 2000 lm L30 3000 lm (2) 5. Colour and colour temperature 6. Colour rendering 22K 2200K (3) CR80 CRI 80+ 27K 2700K CR95 CRI 95+ (4) 30K 3000K RCR80 Radiant CRI 80+ (5) 35K 3500K RCR95 Radiant CRI 95+ (4) (5) 40K 4000K 7. Optics (nominal distribution) NS Narrow spot 10 N Narrow 20 M Medium 40 8. Trim shape 9. Interior finish RD Round ISI Silver SQ Square IBK Black CC Custom (please specify RAL colour) 10. Trim Finish 11. Control WH White NO On/off control BK Black DA1 0-10V dimming 1% linear NST Nickel satin DA2 0-10V dimming 1% logarithmic PDA1 Pro 0-10V dimming 0.1% linear PDA2 Pro 0-10 V dimming 0.1% logarithmic DALI1 DALI dimming 0.1% linear DALI2 DALI dimming 0.1% logarithmic LT Lumentalk (6) PH Phase dimming (consult factory) 12 / 13
12. Installation type 13. Accessories (8) (9) RM Remodel non-insulated ceiling NA No accessory NC New construction non-insulated ceiling SL Softening glass lens IC New construction insulated ceiling (7) HL Honeycomb louvre CP New construction insulated ceiling - Chicago CL Clear glass lens plenum rated option (airtight) (7) RS Linear spread glass lens Notes: Fixed tilt construction is factory set and cannot be adjusted in the field. (1) (2) (3) Consult factory for 347 volts. Available for M distribution only. Available for CR80 only. (4) CR95 and RCR95 available up to 1300 lumens for NS and N distributions, up to 2000 lumens for M distribution. (5) Radiant CRI options available for 3000K only. (6) 1% minimum dimming value. Lumentalk dimming available for RM installation type only. Lumentalk dimming available up to 1000 lumens (CR80, RCR80, CR95 or RCR95), 1300 lumens (CR80 or RCR80). (7) Insulated ceiling available up to 1000 lumens (CR80, RCR80, CR95 or RCR95), 1300 lumens (CR80 or RCR80). (8) Factory installed. (9) Maximum two accessories per fixture. 13/ 13