Commutation Assembly and Adjustment Details Make the Difference Gary Lozowski Morgan Advanced Materials June 13, MEMSA Technical Symposium

Similar documents
Carbon Brush Performance on Slip Rings

The Effect of DC Machine Adjustment on Loop Unbalance

ECEg439:-Electrical Machine II

Technical Developments in the Measurement of Commutator Profiles. Carbone of America. WMEA Tucson AZ. Roy Douglas Technical Manager

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective

INTRODUCTION Principle

Historical Development

Carbon Brushes A Comprehensive Guide, for Industrial and Railway Technology

TOOLS & DEVICES FOR MAINTENANCE OF ELECTRICAL MACHINES

DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO SRM 294

Application Information

STARTER - HITACHI Isuzu Trooper II DESCRIPTION TESTING STARTER PERFORMANCE TESTS Starters HITACHI. Isuzu

TRADE ENGINEERING. Solutions for Success. Products for the Mining Industry. Slip Ring Units

STARTING SYSTEM LOCATION INDEX [LF]


STARTER Mitsubishi Montero DESCRIPTION BENCH TESTING STARTER NO-LOAD TEST ELECTRICAL Mitsubishi Starters. Montero

Basic Motor Theory. Introduction

1991 Mazda MX-5 Miata. STARTER - DIRECT DRIVE ELECTRICAL Mazda Starters - Direct Drive ELECTRICAL Mazda Starters - Direct Drive

DESCRIPTION & OPERATION

Renown Electric s Guide to Carbon Brushes for Motors & Generators

INFORMATION. covering use of Ammeter and Voltmeter ON and 1915 Model Six-54 Electrical System

STARTING/CHARGING SYSTEMS Brought to you by Eris Studios NOT FOR RESALE

Seals Stretch Running Friction Friction Break-Out Friction. Build With The Best!

SERVICING SPECIFICATIONS (1) ENGINE BODY

Carbon Brush & Holder Technical Handbook

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS

1997 Mazda MX-5 Miata. STARTER - DIRECT DRIVE 1997 STARTING & CHARGING SYSTEMS Mazda - Starters - Direct Drive

Therefore, it is the general practice to test the tooth contact and backlash with a tester. Figure 19-5 shows the ideal contact for a worm gear mesh.

Figure 1: Forces Are Equal When Both Their Magnitudes and Directions Are the Same

1994 Mazda MX-5 Miata. STARTER - DIRECT DRIVE 1994 ELECTRICAL Mazda Starter - Direct Drive

SECTION 9 CRANKING SYSTEM CONTENTS

SERVICING SPECIFICATIONS (1) ENGINE BODY

DC Series Motors by Thomas E. Kissell Industrial Electronics, Second Edition, Prentice Hall PTR

Institute of Technology, Nirma University B. Tech. Sem. V: Electrical Engineering 2EE305: ELECTRICAL MACHINES II. Handout: AC Commutator Motors

INTRODUCTION GENERAL GUIDELINES ATTACHING THE DRIVE PARTS

AGN Unbalanced Loads

Introduction: Electromagnetism:

DC Motor Instruction Manual

1994 Mazda MX-5 Miata. STARTER - REDUCTION GEAR 1994 ELECTRICAL Mazda Starter - Reduction Gear

Just what is an alternator?

GEN 5.0 Generator Service Manual

FIBER BRUSHES: The Maintenance-Free Wind Turbine Slip Ring Contact Material

ECEg439:-Electrical Machine II

1950 Pacemaker. Specifications & Adjustments

VALIADIS S.A. HELLENIC MOTORS

Chapter 22: Electric motors and electromagnetic induction

ELEN 236 DC Motors 1 DC Motors

Synchronous Generators I. EE 340 Spring 2011

LECTURE 27 SERVO VALVES FREQUENTLY ASKED QUESTIONS

Service Bulletin Brake Disc Refinishing Guidelines (Supersedes , dated June 2, 2003) October 28, 2003

Question 2: Around the bar magnet draw its magnetic fields. Answer:

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL ELECTRICAL MACHINES

Mechatronics Chapter 10 Actuators 10-3

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

1GR-FE STARTING STARTER (for 4WD) DISASSEMBLY

COMPARING SLOTTED vs. SLOTLESS BRUSHLESS DC MOTORS

Hydraulic Pump and Track Motor for Hydrostatic Transmission

Synchronous Generators I. Spring 2013

DESIGN OF DC MACHINE

Application Note : Comparative Motor Technologies

FARADAY S LAW ELECTROMAGNETIC INDUCTION

The Effect of Spring Pressure on Carbon Brush Wear Rate

ENGINE ELECTRICAL Click on the applicable bookmark to selected the required model year

2006 MINI Cooper S GENINFO Starting - Overview - MINI

Starting Systems & Traction Motor Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 18 Pages Starting & Traction Motor Systems 62 Points

PERFORMANCE THROUGH REVOLUTION

Service Bulletin. Brake Disc Refinishing Guidelines (Supersedes , dated October 28, 2003, to update the information marked by the black bars)

Universal APU2 Pumps AUTOMOTIVE PAINT SERIES

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

Exercise 2-1. The Separately-Excited DC Motor N S EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Simplified equivalent circuit of a dc motor

Engine Electrical System

Chapter 3.2: Electric Motors

Types of Adjustable Speed Drives

INSTRUCTIONS. Delco Systems

INSPECTION ST 13 2UZ-FE STARTING STARTER. Terminal 50. Terminal C. Battery. Disconnect Battery. Terminal C. Disconnect. Battery.

INSTRUCTION MANUAL 272-5X5 ANALOG TRANSMITTER (210 SERIES FLOW METERS) 272-5X7 ANALOG TRANSMITTER (220/240 SERIES FLOW METERS)

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

STARTER SYSTEM TESTING 5.6

20. Install and tighten the cap screws that hold the end frame and field frame together

Focus on Sci. & Tech. Grasp Details

STARTER SYSTEM TESTING 5.6

ATASA 5 th. ATASA 5 TH Study Guide Chapter 27 Pages Ignition Systems 68 Points. Please Read the Summary

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR

STARTING SYSTEM STARTING SYSTEM ST 1

PARTS MANUAL EY35 / EY40 ENGINES. Models. PUB-EP5716A Rev. 04/00

./#0#. 1"&." 1994 ELECTRICAL Suzuki of America Corp. - Starters. Swift

2 Principles of d.c. machines

Lesson 5: Directional Control Valves

Electric motor testing

Motor Basics AGSM 325 Motors vs Engines

Electrical Machines I Week 1: Overview, Construction and EMF equation

TEST ON DC MOTORS. EE 2092 Laboratory Practice III

Universal computer aided design for electrical machines

Air Cooled Engine Technology. Roth 9 th Ch 14 Elect. System Service Pages

Technical Section. Thrust & Horsepower. Tool Assembly T-A & GEN2 T-A GEN3SYS

SECTION 8 2 DO IT YOURSELF MAINTENANCE. Chassis

SPH3U UNIVERSITY PHYSICS

YDRAULIC ISC BRAKES VERVIEW

Electrical Machines -II

ST- 1 STARTING SYSTEM. Page TROUBLESHOOTING... ST-2 STARTER... ST-3 STARTER RELAY... ST- 12 CLUTCH START SWITCH... ST-1 2

Transcription:

Commutation Assembly and Adjustment Details Make the Difference Gary Lozowski Morgan Advanced Materials June 13, 2014 @ MEMSA Technical Symposium

COMMUTATION Commutation is the Reversal of Armature Current in the Armature Coils The following slides and comments will assume that the electrical design of the motor or generator is sound and a proven design.

COMMUTATION Commutation is the Reversal of Armature Current in the Armature Coils Good Commutation or SPARKLESS operation occurs when the parts are machined, assembled and adjusted correctly Sparking at the brushes occurs when parts are machined, assembled or adjusted incorrectly. Rough comms., weak springs, sandblasted BH or excessive vibration can also cause sparking

Main Purpose of a Brush To conduct electrical current from it, to a rotating Commutator or Slip Ring In the case of a DC Motor with a Commutator, it needs to conduct current to each and every commutator segment It needs to have intimate contact with the comm. segments to conduct current without arcing ( Arcing or sparking is current going through air )

Good Commutation is a team effort of the brush, commutator, brush holder and springs. It takes proper mechanical adjustment of these parts. Uniform air gap settings of the poles is also very important. Electrical settings like neutral and interpole strength also need to be correct for good operation of DC Motors & Generators.

Commutation / Brush Demands Since The Beginning (e.g. 1045 KW) Rotational Speed 1200 RPM - 20 Rev per Second!

Commutation / Brush Demands Since The Beginning (e.g. 1045 KW) Bars Pass each brush at a rate of 3000 commutator bars per second! And the brushes need to contact every one of them to prevent arcing

Commutation / Brush Demands Since The Beginning (e.g. 1045 KW) Sliding Speed 70 Miles per Hour 6,123 ft / minute Equivalent to 14,000 RPM of a typical car engine piston

Commutation / Brush Demands Since The Beginning (e.g. 1045 KW) Revolutions per day - 1,728,000 ( 630,720,000 / year )

Commutation / Brush Demands Since The Beginning (e.g. 1045 KW) Distance a brush slides in 6 months- 305,000 miles ( only 274,000 miles at 90% running time )

Commutation / Brush Demands Since The Beginning (e.g. 1045 KW) Commutation Cycles (current reversals) 120 per second (6 per revolution)

Commutation / Brush Demands Since The Beginning (e.g. 1045 KW) Current Switched Per Commutation Cycle 733 Amperes at Rated Current 1466 Amperes at Stall Current

Commutation / Brush Demands Since The Beginning (e.g. 1045 KW) Time to Switch the Current 0.00084 seconds 0.84 milli seconds

Most Draglines in The USA Have Been Doing This For More Than 25 Years No Small Accomplishment!!

What Has Been Done Since The Machines Were New? Larger Buckets Added - Higher RMS Loads - More Heat - Switching Higher Currents Greater % of the Time

What Has Been Done Since The Machines Were New? Static Motor Field Exciters Higher Rope Speeds Increased RMS Current Faster Average Motor Speeds

What Has Been Done Since The Machines Were New? New Controls - Faster Response - Higher Rate Of Current Change (di / dt)

What Has Been Done Since The Machines Were New? - Many Draglines Have Greatly Increased Productivity Since New - Often With Less Maintenance People - And More Pressure for Less Down Time for Maintenance

A1 A2 F1 F2 S S N NZ Approx 30% CZ NZ CZ = Commutating Zone N - N NZ = Neutral Zone N S S

A1 A2 F1 F2 S S N - N N N S S

Straightened-out Connection View Frame Stator Armature Coils S N S N Main Pole Main Pole Main Pole S Commutator Segments A1 Brush Rotation Brush A2

Straightened-out Connection View Frame Stator Armature Coils S N S N Main Pole Main Pole Main Pole S Commutator Segments Brush Rotation Brush A2 A1

Linear Commutation of a Coil That is Correctly Compensated Graph of Current 0 + 200A I Time - 200A t Armature Coils 200A 200A 200A 200A 200A 200A 200A 200A Rotation Commutator Segments Brush 400A V = - K d I d t This is the Voltage generated as one armature coil is commutated.

Machine Adjustments 1. Brush Position ( neutral ) 2. Commutating Field Strength

Factory Method vs Field Method

Excavator MG Set

Methods to Set Electrical Neutral DC Kick AC Null Reversability (Speed & Voltage) Black Band Brush Potential Pencil Volt Neutral AC Curve Method

Black Band Set Up B.B. Gen Comm Field Field ARM Load

Buck Amps Boost Amps Buck Boost Curve 0 50 100 150 Load Amps (%)

Buck Boost Curve Buck Amps Boost Amps 0 X X Band Center on Boost Side (Weak) x No sparking in black area, sparking outside black area 50 100 150 x x Band Center x Corrective Action Remove nonmagnetic shims, add magnetic shims x x Load Amps (%)

Buck Boost Curve Buck Amps Boost Amps 0 X X x Corrective Action Remove magnetic shims, add non magnetic shims 50 100 x 150 Band Center x Band Center on Buck Side (Strong) Sparking with no buck or boost x x Load Amps (%) x

Buck Amps Boost Amps Buck Boost Curve Near perfect black band centered at all loads X x x x 0 50 100 150 X x x x Load Amps (%)

Adjustable.015 Commutating Pole Shim Fixed.125 Thick Commutating Pole Shim GE uses non- Magnetic comm Pole bolts

Commutating Pole & Shims Magnet Frame Commutating Pole Thin Steel Thin Aluminum 1/8 Inch Aluminum 1/8 Inch Steel Order of shims is very important!

Brush Spacing F A B A = B = C = D = E = F = Max. Spacing Diff. = E D C Target is.030 On Westinghouse Equipment Max. Spacing diff =.050 on GE equip.

Brush Arm Spacing Example A F B A = 8.90 B = 8.96 C = 9.02 D = 8.94 E = 9.01 F = 8.85 E D This will take some work to get all 6 measurements within.050 C Max. Spacing Diff. =.170 Target is.050 On GE

Brush Arm

Brush Spacing Clearance hole Commutator

.070-080 Brush Holder Height

BRUSH Brush Holder Spacing BRUSH BRUSH HOLDER This gap between brush holder and commutator is usually between.070 and.093 for most industrial motors. Only on rather small or very large motors is the recommended gap beyond this range. This gap is not always adjustable on newer motor designs. Readjusting this gap should only be necessary after turning or stoning a substantial amount off the commutator or slip ring diameter. Slip ring motors typically have a.125 maximum gap. Too large of a brush holder setting is unstable and can promote a friction chatter condition.

Brush Holder Alignment Brush Holder alignment OK, exactly perpendicular to the slip ring surface or commutator surface Commutator or slip ring Rotation

Brush Holder alignment, not the best, but 1 or 2 degrees trailing is OK Commutator or slip ring Rotation

Brush Holder alignment needs adjustment. This is called leading or stubbing and can cause fast wear or friction chatter. Just 1 or 2 degrees makes a big difference. Commutator or slip ring Rotation

Pole Tip Spacing Frame A B Difference Between A and B is 1/8 Maximum

Uneven And Tapered Airgaps Pole Frame Armature Airgap Pole Frame Airgaps should be equal within.015

Airgap Taper Gauge

Airgap Measurement ( Equal within.015 )

All This Mechanical & Electrical Symmetry Was Important When The Machines Were New With The Upgrades and Productivity Improvements, it is Even MORE SO!!

Circulating currents within single wafer Brush I A Load Amps V R = i c x R A + V CD + i c x R B + V CD R B V CD V CD i c = V R - 2 V CD R A + R B R A V R i c i c Becomes less as R B increases Use high resistivity grade brush for difficult to commutate machines.

Reducing circulating currents with more wafers I A Load Amps V R = i c x R A + V CD + i c x R B +V CD + i c x R w R B V CD V CD R A V R i c R W i c = V R - 2 V CD R A + R B + R W i c Becomes less as R B increases Use a 2 or 3 wafer brush construction for difficult to commutate machines.

Commutator Repair Indicators Situation Runout ( TIR ) Bar to Bar Variance Undercut Depth NEW Less than.0015 Less than.0002.050 or more IN SERVICE Less than.003 Less than.0003.020 or more NEEDS REPAIR More than.003 More than.0003.010 or less

Radial Scale ( +/- 2.0 Mils) 2.0 Profiler MAS - Commutator - Radial Plot 200 1 Brush Path 2 0.0 20-2.0 180 40 160 Brushes Commutator 60 140-2.0 80 0.0 120 100 2.0 2.0 0.0-2.0-2.0 0.0 2.0 Recording Plot Rec# Recording start (Actual) Size TIR Max BTB Mean BTB Std dev Suspect Hi Mica Remark Brush Path 2 2 12 Mar 2003 ( 8:48:43 am) (209) 209 Bars 1.18 mil : 45-10 0.47 : 10-11 0.078 0.075 0 0 These brushes have an easy job of conducting current to each Commutator segment with 1.18 mils TIR.

Radial Scale ( +/- 2.0 Mils) 2.0 0.0 Profiler MAS - Commutator - Radial Plot 200 1 20 Track 2-2.0 180 40 160 60 140-2.0 80 0.0 120 2.0 100 2.0 0.0-2.0-2.0 0.0 2.0 Recording Plot Rec# Recording start (Actual) Size TIR Max BTB Mean BTB Std dev Suspect Hi Mica Remark Track 2 2 19 Mar 2002 ( 4:06:18 pm) (211) 211 Bars 3.39 mil : 1-86 0.44 : 86-87 0.086 0.082 0 0 These brushes will have a harder job trying to contact each Commutator segment with 3.39 mils TIR &.44 Max. BTB

Radial Scale ( +/- 2.0 Mils) 2.0 0.0 Profiler MAS - Commutator - Radial Plot 200 1 20 Brush Path 2-2.0 180 40 160 60 140-2.0 80 0.0 120 100 2.0 2.0 0.0-2.0-2.0 0.0 2.0 Recording Plot Rec# Recording start (Actual) Size TIR Max BTB Mean BTB Std dev Suspect Hi Mica Remark Brush Path 2 4 18 Jun 2003 ( 7:47:42 am) (213) 213 Bars 3.94 mil : 55-3 2.32 : 55-56 0.194 0.259 0 0 These brushes have an impossible task of trying to contact each commutator segment with 3.94 mils TIR & 2.32 MBTB

Radial Scale ( +/- 2.0 Mils) 2.0 0.0-2.0 Profiler MAS - Commutator - Radial Plot 1 * 200 * 20 Brush Path 2 180 * * 40 160 60-2.0 * * 140 * * 80 0.0 120 100 2.0 2.0 0.0-2.0-2.0 0.0 2.0 Recording Plot Rec# Recording start (Actual) Size TIR Max BTB Mean BTB Std dev Suspect Hi Mica Remark Brush Path 2 4 18 Jun 2003 ( 7:47:42 am) (213) 213 Bars 3.94 mil : 55-3 2.32 : 55-56 0.194 0.259 0 0 You can hear brush clatter and see sparking when comm. TIR is excessive. Poor brush life is also realized.

Advanced Pitch Bar Burning

Off Center Commutator Re-surfacing

These brushes are from a motor with a very rough comm. Brush wear is different since TIR of each brush path is different.

Commutator Undercutting

How Much Brush Pressure? The proper amount of brush pressure against the commutator or slip ring depends on the application and/or the brush grade. To calculate the brush pressure; you need to know or measure the spring force and the brush thickness and width. Brush T x W = the cross sectional area. Brushes that contact the commutator at an angle do have more contact area that the product of their T x W, but it is usually not a significant difference so the easier to calculate cross sectional area is used. Recommended Brush PSI Range Application 3.5 to 6 General Industrial Motors 3 to 8 Fractional HP Motors 5 to 10 Traction Motors 3 to 4 Slip Rings Low Speed, Graphite Grade 2 to 2.75 Slip Rings High Speed, Graphite Grade 3 to 5 Metal Graphite Grades

Wear Rate Total Brush Wear 4.5 4 3.5 3 2.5 2 1.5 1 0.5 0 Optimum Range 0 1 2 3 4 5 6 7 8 9 10 11 Brush Pressure ( PSI )

Do not sandblast springs or brush holders! Solvent clean

Do Not mix brush grades or brush springs

Airborne Contaminants 5% Carbon Graphite from the brush 15-20% Carbon Brush Grains of Moisture Copper Oxide 75% Copper Commutator Commutator Film Makeup

Electrographitic Brush Materials and treatments Treatment can lubricate ( reduce friction ) Treatment increases Mechanical Strength Some Treatments Improve Commutation which Lowers Temperature And Increases Life Treatment help brushes survive harsh environments

Contaminants Gear Lubricants Vapors or mist can contribute to copper drag, insulation degradation and brush wear

Blower Inlet Grease splash drawn into Motor and on commutator

Copper Drag

Thank you for your attention Questions?