UNION SERVICE SPECIFICATION NUMBER SU A

Similar documents
SERVICE MANUAL

FN-27 FLASHER RELAY SERVICE MANUAL 4519 * * * * * * * * * * * * * * * *

SL-6 & SL-6A. I UNION SWITCH & SIGNAL l[ml 645 Russell Street Batesburg, SC Service Manual Field and Shop Maintenance

February, Swissvale, Pa. INSTRUCTION PAMPHLET U-5623-A MASTER RELAY FOR AMPLIFIER FOR UNION CODED CAB SIGNAL EQUIPMENT

DT-10 TIME ELEMENT RELAYS

~ SERVICE SPECIFICATION SU-4522-A ~

PV-250 Track Relay. Operating Values For Hz PV-250 Track Relay With 115 Volt Local 440 Turn Track Coil

CHEC"'- INSTRUCTION UNION SWITCH & SIGNAL.. SWISSVALE, PA. DIVISION OF WESTINGHOUSE AIR BRAKE COMPANY

- ~SERVICE SPECIFICATION SU-4549 ~

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

PT-150 PLUG-IN THERMAL RELAY WITH SNAP-ACTION BACK CONTACT *****************

Instructions for Replacing

STYLE PN-59 SLOW PICK-UP PLUG IN D.C. NEUTRAL RELAYS FOR CODED CAB SIGNAL EQUIPMENT. WABCO PART NUMBERS N436928, N and N

ADDE STYLE "H" AND "H-2" D.C. SEARCHLIGHT SIGNAL OPERATING UNIT WITH ALNICO PERMANENT MAGNETS

I UNION SWITCH & SIGNAL llfilj

COLLATOR REFERENCE CONTENTS. Copyright 1947, ADJUSTMENTS. FeedHoppers... Feed Knives... FeedKnifeGuides... Card Guides... FeedRolls..-.. rn...

RELAYS HAVING NO KS DESIGNATIONS WARD LEONARD COMPANY, ALLEN-BRADLEY COMPANY AND WESTINGHOUSE CORPORATION REQUIREMENTS AND ADJUSTING PROCEDURES

P. Sub 4 184A404. Sub 3 876A220

PN-250BE D.C. HIGH EFFICIENCY BIASED PLUG-IN RELAY. (li to 007) TABLE OF CONTENTS ARMATURE AIR GAP ADJUSTMENT CHECK OF CONTACT OPENINGS

CR193 Vacuum Limitamp* Contactors

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

INSTRUCTIONS. GEI-38974A Supersedes GEI INSTANTANEOUS CURRENT RELAY TYPE PJC2OA GENERALS ELECTRIC

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

41-747G. Figure 1: Type DGF Relay without case (Photo)

1000 Technology Drive, Pittsburgh, PA Russell Street, Batesburg, SC Plug-In Replacement for the PF256 Flasher Relay

COM Overcurrent Relay

Type CRN-1 Reverse Power Relay 50 and 60 Hertz

PV Element AC Vane Relay

~... se_rv_ic_e M_A_NU_AL_2_44_4._z1,~

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY OPEN, P/N SERIES

Primary Clutch/Brake Pin Drive, Spline Drive PCB-825, PCB-1000, PCB-1225 Primary Clutch/Brake Coupling PCBC-825, PCBC-1000, PCBC-1225

Installation Instructions

Rating when used as a weight distributing hitch with spring bars:

Maintenance Information

PP-151. Service Manual 4551 G. An Ansaldo Signal Company. IUNION SWITCH & SIGNALl[fil] Magnetic Stick DC Plug-In Relay

U STYLE "TP" TIME RELEASE UNION SWITCH & SIGNAL DIVISION OF WESTINGHOUSE AIR BRAKE CO. INSTALLATION AND MAINTENANCE AUGUST, 1951

Installation Instructions

PN-lSOB D.C. PLUG-IN RELAYS (Having Part Number Suffixes Under O 11 )

BRC HIGH END BRAKE BALANCE BAR

SERVICE AND REPAIR PARTS NEMA SIZE 3, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 4, SINGLE POLE, NORMALLY OPEN, P/N SERIES

Rating when used as a weight distributing hitch with spring bars:

ALTERNATOR PRECAUTIONS. Some precautions should be taken when working on this, or any other, AC charging system.

Cylinder Installation Compression/Stripper, for Models, 22HF, 16HF, 1600 machines

DAKE / JOHNSON VERTICAL BAND SAW

INSTALLATION INSTRUCTIONS

Syntron F-450-C Electromagnetic Vibratory Feeder

Convertible - Rated 3 4-Ton /2-Ton Nylon Strap Hoists Refer to any questions about the use, application, repair or testing of this hoist to:

STARTING/CHARGING SYSTEMS Brought to you by Eris Studios NOT FOR RESALE

... v e cdi c.cr. r'=i. IBM WiC;t D.P:'Cf`:DE.PT..-PRINTE:DriN UNiTED KINGDOM

MAINTENANCE WEIGHT RATINGS WARNINGS. warning: never exceed your vehicle manufacturer's recommended towing capacity

STARTER SYSTEM TESTING 5.6

STARTER SYSTEM TESTING 5.6

Control Relays Overview

INSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY CLOSED, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY CLOSED, P/N SERIES

B CW POWER RELAY

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

SERVICE MAN.UAL 4551-F~.

Engineering (Signalling) Instruction S-60 Highway Grade Crossing Gate ESI Applicability. ARTC Network Wide

Installation instructions

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

Vickers. Two-Stage Flapper Type Servo Valve. Valves. Overhaul Manual SF SF Revised 02/01/74 I-3063-S

MAINTENANCE WEIGHT RATINGS WARNINGS. warning: never exceed your vehicle manufacturer's recommended towing capacity

CAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877

INSTRUCTION MANUAL. Series PROCUNIER SAFETY CHUCK CO. (Serial Nos. B4870 and higher. (Serial Nos. B9230 and higher

Conversion of a Model A Ford Starter for 12 Volt operation. By Dick Harrell Gra-Neva A s

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

www. ElectricalPartManuals. com INSTRUCTIONS TYPE HQS PHASE SELECTOR RELAY FOR INSTALLATION OPERATION MAINTENANCE APPLICATION

C. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View

Industrial Turbo Meters, Sizes 2" through 6"

Style Q Plug-in Relays

B, are made of %-in. strap iron. Armature

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

www. ElectricalPartManuals. com INSTRUCTIONS DynAC Broke DESCRIPTION ADJUSTMENT MAINTENANCE The Alternating Current Dynamic Brake

GEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K. GE Protection and Control 205 Great Valley Parkway Malvern, PA

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

Maintenance Instructions

4.0 OPERATION Type ITH-T Relay

#92 DISC BRAKE ADJUSTMENTS # BRAKE MONITOR

MAINTENANCE WEIGHT RATINGS WARNINGS. warning: never exceed your vehicle manufacturer's recommended towing capacity

ESD5500E Series Speed Control Unit

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

CARTER DOWNDRAFT CARBURETOR Terraplane All Models. Technical Information

70 Series 8700 Coupler 2-pc Hub & Shaft Three Phase Brake Instructions IP43 & IP56 (NEMA 2 & 4) Housing

./#0#. 1"&." 1994 ELECTRICAL Suzuki of America Corp. - Starters. Swift

SWITCHES PLUNGER TYPE PRIMARY AND SECONDARY LINE SWITCHES AND OUT-TRUNK SWITCHES REQUIREMENTS AND ADJUSTING PROCEDURES

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction

ELB ELB

Service Instructions. Syntron Light-Capacity Electromagnetic Model: F-T01-A DF-T01-A

Electric motor testing

A/C COMPRESSOR SERVICING Article Text 1991 Saab 9000 For Copyright 1997 Mitchell International Friday, October 15, :22PM

CARD RECORDER MECHANISMS

Maintenance Information

INSTRUCTIONS Ç CAUTION Ç IMPORTANT

INSTALLA TION INSTRUCTIONS 31330

Industrial Control Transformers

Transcription:

UNION SERVICE SPECIFICATION NUMBER SU-1862 -A UNION SWITCH & SIGNJU,.,... SWISSVALE, PAe DIVISION OF WESTINGHOUSE AIR BRAKE COMPANY DN-10 TRAIN CONTROL SPECIAL SLOW DROP-AWAY RELAYS ******************** For other DN-10 Train Control Relays See Service Specification SU-1862. This service specification provides information required for repair and adjustment for Style DN-10 special slow drop-away relays. These relays are used mainly in- the engine equipment of train control apparatus, and are provided with coil springs located at the ends of the armature to hold the armature down so that vibration will not open the back contacts when the relay is deenergized. 1. Coils and Back Strap Whenever it is found necessary to replac;e coils, care should be taken to see that sufficient compression washers are used under the coils to make turning of the coils difficult, so that they will not vibrate in service. However, it should be noted that the back strap is tightened securely against the end of the cores and not held away by the coils. The contacting surfaces between the back strap and tops of the cores should be clean and make good contact with each other. If necessary, the tops of the cores may be dressed with a fine flat file carefully held down against both cores. The ground surface of the back strap may be cleaned with fine sand paper. 2. Armature and Pivot Screws The armature should be set to a parallel physical air gap of not less than 0. 013"; allowing 0. 001" for plating or other rust protection on armature and pole faces, this insures a minimum magnetic air gap of 0. 015". The safety stop pins in the armature should not touch the pole pieces unless the air gap is reduced by approximately O. 005". Relay pivots should be inspected and replaced when worn. When making replacements, it should be noted that the armature has from 0.010" to 0.020" end play after the pivot screws are tightened, and that it does not bind against the pivots. The nominal dimension of the pivot screw is 0. 0635" and on new relays the clearance between the pivot and the bearing should not be less than 0.002" nor more than 0. 004". January 1962 B0.62-100-1.62.3 Printed in U. S. A.

U, S, & S, - 2 - Service Spec. SU -1862 -A 2A. Oiling of Bushing Holes and Pivots For oiling trunnion screw pivots and bushings in the armature, we recommend Union Relay Oil, Pc. UJ41099. When using this oil the cap is turned carefully until free, and then when withdrawing the applicator rod, the rod shall be drawn slowly across the edge of the bottle opening to remove any excess oil. This rod shall be returned to the bottle without comingin contact with any foreign material. It shall be wiped clean each time that there is suspicion of contamination, and the bottle shall be closed promptly with its own cap. IT IS VERY IMPORTANT THAT THE OILING SHALL BE PERFORMED AS FOLLOWS: a. The Bushing Holes in the armature shall be carefully examined to check that they are perfectly clean and free from dust before oiling. In withdrawing the rod from the oil it shall be drawn slowly against the rieck of the bottle so as to remove all drops of oil adhering to it. The rod shall be moved slowly around the inside of the bushing hole so as to leave only a thin film of oil on the bearing surface. b. The Bearing Area of the Pivot Screws shall be thoroughly covered with oil by means of the rod, the rod being withdrawn from the bottle in such a manner so as to leave a drop of oil on it. The excess oil on the pivots shall be removed by just touching it with a clean lintless cloth. Care shall be taken not to cover the shoulder or threaded portion of screws with oil. c. Care Shall Be Taken that the oiled parts are protected from dust from the time of oiling until the relay is sealed. other purposes. 3. Contact Adjustment This oiling is necessary only when relay is being shopped for When replacing contact springs it should be noted that the contact springs bear the mark "11" or "14" at the back end near the point where the flexible con - nectar is soldered to the spring. Nickel springs marked" 11" and phosphor bronze springs marked "14" have the same characteristics and are therefore entirely interchangeable. Before adjusting contacts, all silver tips should be cleaned with a fine file. (No. 4 equalling file, 0. 040" thick, is recommended.) All screws holding the contact springs and supports, and back contacts, should be checked for tightness. All springs should extend straight out in line with the surface of the support block to which they are attached. When replacing contact springs, avoid all bending of springs except as necessary to secure alignment with old springs. Contact adjustment, when needed, should be made by adjusting the carbons.

u. s. & s. - 3 - Service Spec. SU-1862-A The front contacts should be adjusted with a spacer (See Calibration Table) between the center stop pin in the armature and its stop, with the armature held firmly against the spacer and stop by pressure applied between the stop pin and the pivot screws, so as to bring the armature as close to the pole pieces as the play in the pivots will permit. If it is convenient, the pressure may be applied by energizing the relay at approximately the charge value, The carbons should be adjusted so that they are in line with the silver tips and light is barely perceptible between the surfaces when the nominal spacer, as specified in the tables, is used. A spacer 0. 001" thinner should allow the contacts to close. The carbons should be in line when adjusted and tightened and should extend beyond the edges of the contact spring at least 1/64" on each side. With the relay energized, the silver tips of the spring should extend about 1/8" beyond the carbons. After front contacts have been set, the spacer under the stop pin should be remov~d and the relay inverted, allowing the contact springs to rest against the front contacts while back contact adjustments are made. The back contacts should be aligned to give at least 0. 050" contact opening, the back contacts being filed in a plane parallel to the springs. A contact spacer as specified in the tables may be used to obtain the back contact adjustment. With the armature held against the stop pin, there should be at least 0. 050" between the tips of the back contacts and the nearest point on the contact springs. With the relay upright and the armature in the deenergized position, back contacts should be not less than 3/32" from the end of the silver tip on the spring and not less than 3/32" from the end of the flexible part of the spring. Back contacts should extend at least 1 / 64" be - yond the edges of the springs on each side. The nut and screw locks on the front and back of the front contact post should be locked after these adjustments are made. 4. Calibration After the relays have received the above inspection and adjustment, they shall be calibrated to meet the requirements outlined in the tables below, Any changes of contact adjustment necessary in order to meet calibration requirements should be made by moving carbons or back contacts and not by bending contact springs. The changes in current while obtaining the calibration values should be made very slowly otherwise the results will be inaccurate. a. Coil Hold-Down Spring Adjustment The coil springs should be adjusted while calibrating the relay, putting as much tension in the springs as possible, still leaving the relay within calibration requirements. This adjustment is made by raising or lowering the movable support for one end of the spring. The two springs should be adjusted to approximately the same tension by noting that the supports are raised the same

U.S.&S. - 4 - Service Spec. SU-1862-A distance from the end of the support post. The supports for the coil springs should be lined up as nearly as possible, so that the springs will be straight. It should be noted also while making this adjustment and locking the coil spring supports, that the studs in the back corners of the relay top plate are securely tightened so that they will not turn. After the adjustment of the hold-down springs is completed, the hold-down torque should be checked with the relay inverted by applying a torque of 175 inch grams to the armature. This may be checked with a 175 gram weight applied to the shipping screw hole or by a gram gauge force of 1 75 grams applied at the shipping screw hole (l" in front of the pivot screw centerline) or of 119 grams applied at the front edge of the armature 1-15/32" in front of the pivot screw centerline. With this torque applied, the back contacts should remain closed. After the contact and coil spring adjustment has been completed the back.stop should be adjusted so that light is barely perceptible between the back stop and the armature. b. Drop-Away with Contact Pressure The relay shall be given a charge as specified in the tables and current gradually reduced until the armature drops away. This will be the dropaway value of the relay and should not be less than the value specified. c. Direct Pick-Up After obtaining drop-away value the circuit should be opened for one second and current again applied in the same direction and increased gradually until the armature picks up. This value should be between the minimum and maximum values specified in the tables. d. Armature to Stop Pin After obtaining the direct pick-up value, the current should be gradually increased until the armature strikes the stop pin. This value should not be greater than specified in the table. On some relays, the armature goes to the stop pin directly at the pick-up value; when this is true, the table shows the same value for maximum pick-up and armature to stop. e. Drop-Away Retardation In addition to the above calibration values, the time of dropaway of the relay should be obtained. This may be done by using a cycle counter connected to the contacts of the relay as shown in Figure 1. The time of dropaway should not be less than specified in the table. To measure drop-away retardation, using the circuit of Figure 1, operate snap switch "C", after permitting sufficient time for the relay to saturate. The timer shown may be a Westinghouse Cycle Counter, a General Elec-

U.S. & S. - 5 - Service Spec. SU-1862-A MODIFIED SNAP SWITCH / nsv. A.C. 115V. A.C. 0 R 0 RELAY ON TEST...,,,,,.., L'.:=::::::::::1-RESISTOR WESTINGHOUSE CYCLE COUNTER OR G. E. CO. SYNCHRONOUS TIMER. (ALTERNATE) STANDARD ELECTRIC TIME CO. TIMER MODEL AC-1. FIGURE l tric Synchronous Timer, or a Standard Electric Time Co. Timer Model AC-1. A snap switch is necessary at "C", since there should be no time lost between opening the relay circuit and starting the timer. An ordinary 3-way snap switch can be used by removing the jumper and connecting as shown. 5. Contact Resistance Resistance of front contacts should be measured with the armature against the stop pin. The initial cleaned resistance of front contacts should not exceed the values given in the following table: Silver to carbon Silver to silver-impregnated carbon Back contacts, silver to silver 6. General Inspection 0.18 ohm 0.09 ohm 0.03 ohm Inspection should insure that all parts are properly tightened and locked, and that no carbons are cracked. A careful inspection should be made to insure ample clearance of the armature from the cork gaskets at the back of the relay, the armature back stop bracket at the front of the pole pieces and the holddown spring bracket at the ends of the armature. Clearance should not be less than 1/16" at any of these points. 7. Assembly of Base to Relay The nuts holding the base of relay should be tightened carefully in order not to put unnecessary strain on top plate; this can be accomplished by bringing the nuts to a "hand-tight" position, where the base just starts compressing the gaskets, and then giving the nuts one complete turn with wrench to tighten.

u. s. & s. - 6 - Service Spec. SU-1862-A TABLE #I Relay Type Letter See Table #1-Afor Piece Number of Relays Corresponding To Letters in this column. SERVICE CALIBRATION VALUES FOR RAILROAD SHOP USE FOR DN-10 TRAIN CONTROL SPECIAL SLOW DROP-AWAY RELAYS A B c D Contact Combination 4F-2B 3F-3B 4F-4B 4F-4B Ferrules Under Coils Copper Copper Wood Copper Pc. UMl 70461 Pc. UMl 70461 Pc. UM197740 Pc. UMl 70461 Ohms Res. Per Coil 215 * 215 * 800 215 * CONTACT I Front 0.030" 0.030" 0.030" 0.030" SPACERS I Back 0.055" 0.055" 0.055" 0.055" Charge Amps. 0.110 0.110 0.110 0.110 Full Stroke Amps. 0.035 0.035 0.016 0.035 Max. Direct Pick-up Amps. 0.035 0.035 0.016 0.035 Min. Direct Pick-up Amps. 0.028 0.028 0.012 0.028 ** Min. Drop-Away With Springs Amps. 0.006 0.006 0.0024 0.006 DROP-AWAY Volts 32 32 64 32 RETARDA- Amps..148.148.080.148 TION Sec. Min. 5 5 1. 65 5 Sec. Max. E 4F-4B Wood*** Pc. UMl 97740 215 * 0.030" 0.055" 0.110 0.045 0.045 0.028 0.006 32.148 3 3.5 * Each Winding. ** Relays should be taken out of service and readjusted when drop-away values drop below 78% of those given in table. Later design relays use a small copper ferrule Pc. UMl 70461 under coil in place of wood filler Pc. UM! 97740 and a larger wood filler Pc. UM215909 on other core near backstrap in place of large copper ferrule Pc. UMl 70462. *** TABLE #1-A When readjusting relays obtain Piece Number from Name Plate and Note from this Table correspondingtype Letter referring to Calibration Table #1. Type Type Type Type Pc. No. Letter Pc. No. Letter Pc. No. Letter Pc. No. Letter UN169783B B UN176778B E UN207599B E UN250629A D UN170457 B UN194325A c UN207640A D UN250629B E UNI 72848A A UN194325B c UN207640B E UN262085A D UN176778A D UN207599A D UN211936 D UN262085B E