STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

Similar documents
STC 2W Series Solenoid Valves

STC 2L Series Solenoid Valves

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

STC 2P025 Series Solenoid Valve

3V SERIES SOLENOID VALVE

4V130P-430P SERIES AIR PILOT VALVE

2V1-3V1 SERIES SOLENOID VALVE

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

STC 2E Series High Pressure Solenoid Valves Two-Way, Pilot Piston, Normally Closed

STC. Manual & Actuated Process Valves. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Solenoid & Process Valves

S T C. STC Air Actuated Valves. Fine Quality. Precision Engineered Advanced Design. Excellent Prices. connects fluid power to industrial automation TM

STC 2W160 Series Solenoid Valves

STC KS/KD Air Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

KS/KD Air Actuated Ball Valves

AIR & ELECTRIC ACTUATED VALVES

STC Air Cylinders. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Air Cylinders

SERIES 740 VALVES PNEUMATIC DIRECTIONAL CONTROL

HR-20P Pneumatically Controlled Pressure Regulator

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

BI-PIPE INSTALLATION MANUAL. AUDI PERFORMANCE & RACING 1027-B Opelika Road Auburn Alabama 36830

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

II DISTRIBUTION & SUBSTATION TYPE C

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

DAP-625S and DAP-875S

22421 SPORT SWAY BAR SET TOYOTA COROLLA

OWNERS MANUAL JANUARY 2007 ISO

Type Flexair Pneumatic Pressure Control Valves

ADI-125/750 ADI-125/1500 ADI-125/2500

GWC Valve International

Straight-Bore Clutch LSCC-32, 44, 54

2015 & 2018 Fender Brace Installation Instructions

Rear Suspension System C-10 Pickup Truck

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

Warner Electric UNIBRAKE Motor Brakes

December 1, 2011

AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

WEB CONTROL PRODUCTS

TYPE S RELAY VALVE (Volume booster) Service Manual

FCB-450, LCB-600, MCB-800

K-Motion Valve Springs are the choice of winning racers. K-Motion

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

MIL-24/2600Q MIL-24/3200DQ

Anti-Roll Bar Set # 2279, Cadillac CTS V6 & CTS-V

MOVE ON TO THE REAR BAR INSTALLATION

INSTALLATION INSTRUCTIONS

2006 SHOCK TOWER BRACE 93-UP F-BODY CAMARO/FIREBIRD

Web Volume Control Model WV220

SPC-PANEL Simplex, Single Phase Pump Control Panel

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Terms and Conditions

1401 / 1402 / 1403 ADJUSTABLE TRAILING ARM MOUNT BRACES INSTALLATION OF HOTCHKIS PERFORMANCE ADJUSTABLE TRAILING ARM MOUNT BRACES

Losi (LOSB9810) 2400mAh 11.1V LiPo Transmitter Battery for JR Z1, KoPropo Helios, and Other Radios of Similar Battery Configuration

Water Jetter Units DU JT50 / DU JT100

AMES 2016 Price List. Backflow Prevention Products and Repair Kits and Parts. Effective February 29, 2016

INSTALLATION OF HOTCHKIS FRONT STABILIZER BAR

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

10 Year Limited Warranty

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

AC/DC Powered Peak Detection Fast Charger for 4- to 8-Cell Ni-Cd & Ni-MH Batteries

Sport Sway Bar Kit UP SCION xb

Operation and Maintenance Manual for Multipurpose Actuators. 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator

END USER TERMS OF USE

Camaro / Firebird. Please read the following key points before installing this kit.

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

P/N# Performance Lowering Springs Installation Instructions

2282R GM A Body Extreme Rear Sway Bar

Sport Sway Bar Kit (22431 ) Subaru Forester INSTALLATION OF HOTCHKIS FRONT SWAY BAR

Sport Sway Bar Kit Chevy Camaro

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

PIVOT BUSHING KIT GM F-BODY

MityFlex Peristaltic Pump

Please read the following key points before installing this kit.

DC to AC Power Inverters

16385 Steering Tie Rods Chrysler A-Body

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Price List. Backfl ow Prevention Products, Repair Kits, and Parts. Effective July 2, AmesFireWater.com 2018 AMES FIRE & WATERWORKS PRICE LIST

SPORT COIL SPRINGS Scion xa & xb Part #19412 INSTALLATION OF HOTCHKIS FRONT COIL SPRINGS

Bulletin H-Tech 03 High Pressure Valves Series H

FR1118- P10. User s Manual

BMW E46 M3 SPORT SWAY BAR SET # 22826

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Installation / Operation Instructions Sunnex ORION Series Exam Lights

PowerMax Diesel Upgrade For Cummins Engines

AD-7 THERMAL INDICATING AMMETER

4/6 Coil Spring Kit C-10 Truck

Motorized Stainless 2-Way Valves

Servo-operated 2/2-way solenoid valves Type EV220A

75500MAX Series and 75500MAXM Series

Rear Sway Bar Kit 22390R C-10 Truck

Do not install and/or operate this safety product unless you have read and understand the safety information contained

Sport Coil Springs Dodge Magnum, Chrysler 300C Dodge Challenger SRT Dodge Challenger R/T

Transcription:

STC 2DS500-2000 Series Anti-Hammering Slow Closing Pilot Solenoid Valves 2DS500-2000 Series Solenoid Valve Specifications Valve Model 2DS400F 2DS500F 2DS650F 2DS800F 2DS1000F 2DS1250F 2DS1500F 2DS2000F Valve Type Action 2 Way, Normally Closed (NC) Pilot Diaphragm, Slow Closing, Uni-Directional Orifice (mm) 40 50 65 80 100 125 150 200 Cv 21 30 52.5 81.7 128.4 221.7 291.7 513.5 Operating Pressure 6 to 175 PSI (AC Coil), 6 to 116 PSI (DC Coil) Operating Temperature Media: -5 to 80 C (NBR Seal), -5 to 120 C (Viton Seal); Ambient: -5 to 45 C Port Size (Flange) 1 1/2 2 2 1/2 3 4 5 6 8 Body Materials Seal Materials Coil Duty Voltage Voltage Tolerance Coil Power Electrical Connections Installation Service Stainless Steel NBR (Buna N), Options: Viton, EPDM Class H, IP65, 100% ED (Continuous Duty) Voltage Options: 12, 24VDC; 24, 110/120, 220/240 VAC, 50/60Hz 10% of Specified Voltage 13W (100 PSI); 20W (175PSI) DIN 43650, Form A No Orientation Requirement (Optimum Position: Flow Horizontal and Solenoid Vertical) Air, Inert Gas, Water, Liquid S T C TM 1

2DS500-2000 SERIES SOLENOID VALVE COMPONENTS DIN HOUSING (DIN 43650A) PLASTIC ENCAPSULATED COIL ARMATURE TUBE (STAINLESS STEEL) SCREWS, 4X (STAINLESS STEEL) PLUNGER (STAINLESS STEEL) PLUNGER SEAL (NBR) TOP VALVE COVER (STAINLESS STEEL) SPRING ( STAINLESS STEEL) DIAPHRAGM SEAL (NBR) BOTTOM VALVE BODY (STAINLESS STEEL) 2

Installation and Operation: To connect the valve Inlet and Outlet: Connect the inlet and outlet in the direction of the arrow marked on the valve. To install coil: Put the coil onto the armature tube of the valve. Put the lock-washer and nut onto the armature tube. Hand tighten the nut, then use a wrench to tighten the nut to a quarter turn; do not over-tighten the nut, it may cause the armature tube to fail prematurely. To connect DIN coil: 1. Remove the Philip screw from the plastic housing and unplug it from the DIN coil. 2. From the screw opening, push the terminal block out from the plastic housing. 3. Note the 1, 2 and ground markings on underside of DIN enclosure. 4. For DC DIN Coil, Connect 1 to Positive, 2 to Negative. 5. For AC DIN Coil, connect 1 to HOT wire, 2 to Neutral wire, and if required connect 6. Do not energize the coil without installing it onto the valve, it will burn the coil and create fire hazards. Safety Note: Standard valves are supplied with continuous duty coils. The proper class of insulation for the service is indicated on the coil. The coil temperature may become hot after being energized for extended periods, but it is normal. Do not energize the coil without installing it onto the valve or connect the coil to a wrong voltage, as it may overheat and damage the coil; although the coil is made of flame retarded material, misuse of the coil in this manner could create fire hazards and generate smoke or burning odor which indicates excessive coil temperature and should disconnect the power to the coil immediately. Operation: 2DS series valve is a 2/2 Pilot Diaphragm, Normally Closed Solenoid Valve. When the valve receives an electrical signal, a magnetic field is formed which attracts the plunger covering the pilot orifice to lift off and allow the media to escape into the outlet port, which causes pressure on the top of the diaphragm to drop. As the pressure is reduced, the full system pressure on the other side of the diaphragm acts to lift the diaphragm away from the main orifice and allows the media to flow through the valve. Since the bleed orifice in the diaphragm is dimensionally smaller than the pilot orifice, the system pressure cannot rebuild on the top of the diaphragm as long as the pilot orifice remains open. When the valve is de-energized, it releases its hold on the plunger. Then the plunger forced by the spring to drop and cover the pilot orifice. As the media enters through the diaphragm bleed orifice into the top side of the diaphragm, it causes the pressure to build up and forces the diaphragm down until it covers the main orifice and stops media flow through the valve. The 2DS series valve is to be used with clean media. If the pilot holes are blocked the valve will not operate properly, the pilot holes need to be cleaned and unblock. 3

STC Solenoid Coil Wiring Instructions ELECTRICAL CONNECTION PROCEDURE [1] [2] A: DIN Connector: [1] Remove the Philip screw from the plastic housing. [2] Unplug the plastic housing from the DIN coil. [3] From the screw opening, use the screw to push the terminal block out of the plastic housing. [4] Note the 1, 2, and ground markings on underside of DIN enclosure. [5] For DC DIN coil, connect 1 to positive, 2 to negative. [6] For AC DIN coil, connect 1 to HOT wire, 2 to neutral wire, and if required connect ground to ground wire. B: Grommet/Lead Wire Connector: DC: Red=Positive, Black=Negative AC: Black=Hot, White=Neutral/Common To download detail procedure: please visit www.stcvalve.com [3] Top of the wiring terminal block StcValve.com; Tel:650-856 8833 [4] [5] & [6] TM S T C 4

2DS500-2000 Series Solenoid Valve Installation Dimensions D (Out-side Dia.) H D2 (Bolt Hole Dia.) D1 (Bolt Hole O.C. Dia.) L Model: 2DS Series Valves Dimensions (MM) Stainless Steel Port Size Orifice Cv D (OD) D1 (OC) D2 (Thread Hole Dia) L H H1 2DS400F-1 1/2 1 1/2 40 21 150 110 18 (4x) 182 196 125 2DS500F-2 2 50 30 165 125 18 (4x) 215 200 120 2DS650F-2 1/2 2 1/2 65 52.5 185 145 18 (4x) 256 280 185 2DS800F-3 3 800 81.7 200 160 18 (8x) 277 287 190 2DS1000F-4 4 100 128.4 220 180 18 (8x) 350 330 230 2DS1250F-4 5 125 221.7 250 210 18 (8x) 425 437 310 2DS1500F-4 6 150 291.7 285 240 22 (8x) 450 460 318 2DS2000F-4 8 200 513.5 340 295 22 (12x) 560 547 380 5

WATER FLOW RATE (GPM) 1200.00 2DS400-800 SERIES VALVE WATER FLOW RATE VS PRESSURE 1000.00 2DS400 2DS500 2DS650 2DS800 800.00 600.00 400.00 200.00 0.00 0 50 100 150 200 PRESSURE (PSI) 6

WATER FLOW RATE (GPM) 8000.00 2DS1000-2000 SERIES VALVE WATER FLOW RATE VS PRESSURE 7000.00 2DS1000 2DS1250 6000.00 2DS1500 2DS2000 5000.00 4000.00 3000.00 2000.00 1000.00 0.00 0 50 100 150 200 PRESSURE (PSI) 7

Catalog No.: PUB 2012 2DS500-2000 Terms and Conditions By purchasing from SIZTO TECH CORPORATION (STC), you agree to these TERMS AND CONDITIONS. No other terms shall apply except as agreed in writing signed by us. We reserve the right to correct typographic errors and reject orders. SHIPMENTS: All shipments are F.O.B. 892 Commercial Street, Palo Alto, CA 94303, USA. Most orders are shipped via UPS Standard Ground unless instructions accompany order. Outside the UPS zones, shipment will be made Best Way. The responsibility for goods delay, lost or damaged in transit rests with the carrier and purchaser. Purchaser may purchase shipping insurance to cover lost or damaged products caused by shipping. RETURN OF MERCHANDISE: No merchandise is accepted for return 30 days after delivery date. No credit allowed on merchandise shipped as ordered and returned without obtaining an authorization number IN ADVANCE. A 20% restocking charge applies to all returns, and transportation charges must be fully prepaid. We will pay ground transportation charges on re-sent or returned merchandise due to STC's error. Shortages & Mis-Shipments: Any shortages or mis-shipment must be reported within 15 days. CANCELLATION POLICY: Blanket order can be canceled 90 days before scheduled ship date. There will be a 10% charge if a blanket order is cancel within 90 days of scheduled ship date, and a 20% charge if cancel within 60 days. Regular order for non-custom parts can be canceled any time before the order is shipped. For custom parts, a 30% down payment is required either at the time of order or 90 days prior to scheduled ship date, whichever comes later.. Remittances should be sent to: Sizto Tech Corporation, 892 Commercial Street, Palo Alto, CA 94303, USA Credit Card Payments: Visa, MasterCard, Discover, or American Express Accepted International Customers: Advance Payment Required via Bank Wire, Cashier's Check or Approved Credit Card. Credit Application: To establish a net 30 day account, please mail or fax three trade references with complete mailing addresses and account numbers. LIMITED WARRANTY IMPORTANT NOTICE TO PURCHASER: Sizto Tech Corporation (STC) only warrants this product to be free from defects in materials and workmanship at the time of shipment. This limited warranty expires one year after delivery to the end-user. STC s entire obligation to the Purchaser for breach of this limited warranty shall be limited to replacement of the defective product or refund of the original purchase price of this product, at STC s option. Purchaser has thirty (30) days to return the goods after STC has agreed to accept the return. All freight charges on returned material shall be paid by the Purchaser. STC s limited warranty shall not apply, however, to the product that have been subjected to misuse, alteration, accident or negligence during handling or storage.. DISCLAIMER OF IMPLIED WARRANTIES: All implied warranties, which may arise by implication of law or application of course of dealing or usage of trade, including, but not limited to, implied warranties of merchantability or fitness for a particular purpose are expressly excluded. There are no warranties, which extend beyond the description of the faced hereof. The end user is solely responsible for the suitability and fitness of this product selected for a particular application. OBLIGATIONS You warrant, represent and agree: (1) to comply with all laws; (2) that our sale and shipment of the product will not, by export thereof, your legal status or otherwise, cause us to violate any law; and (3) to indemnify us against any losses from a failure by you or a third party to comply with law or these terms and conditions, or from use of the product. SAFETY WARNING Failure or improper selection or improper use of the components and products described herein or related items can cause death, personal injury and/or property damage. This document and other related information from STC provide products options for further investigation by users having the technical expertise. It is important that you analyze all aspects of your application and review the information concerning the component or product in the current catalog. Due to the variety of operation conditions and applications for these components or products, the user, through his own analysis and testing, is solely responsible for making the final selection, installation and maintenance of the products and assuring that all performance, safety and warning requirements of the application are met. All products set-ups and maintenance require the supervision of a qualified individual who is familiar with installation, inspection and testing through training or experience. IMPORTANT NOTICE: The products described herein, including without limitation, product features, specifications, design, availability and pricing, are subject to change without notice. We continuously improve the products, and we reserve the right to change specifications without incurring any obligation to incorporate new factors in equipment previously sold. Information contained herein may be changed without prior notification. S T C Sizto Tech Corporation 892 Commercial Street Palo Alto, CA 94303 USA Tel: 650-856 8833 Fax: 650-856 8811 Email: Sales@StcValve.com; www.stcvalve.com 8