Series A Construction

Similar documents
505 Size 5 Series A Construction

700 Type P & PK DC Relays Timer Units Latch Units Series A and B Construction. Renewal Parts

Bulletin 1494M Fixed Depth Remote Operated Disconnect Switches Renewal Parts

Bulletin 509 Three Phase Full Voltage NEMA Starters Size 00 (all series) Renewal Parts

Page 1 of 9 Knowledgebase Technote ID # Q /24/2006

Electrically Held to Mechanically Latched Contactor

Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch

Allen-Bradley Parts. CENTERLINE 2500 Motor Control Centers Installing, Joining and Splicing Columns. Installation Instructions. Catalog Number 2500

Spare Allen-Bradle. Battery Replacement. Installation Instructions. About This Publication. Catalog Number 2711P-RY2032

Installation Instructions. Y-Series Brushless Servo Motor

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

Battery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions

Direct Communication Module

PowerFlex 7000 AC Drive with Direct-to-Drive Technology. Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions

Model C230 Pump Controller

Example Maintenance Schedule 1. The attached document is an example of an acceptable maintenance schedule.

IEC Starter Approximate Dimensions

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

USER MANUAL Bulletin 1512A 400A One-High Cabinet Standard and Arc-Resistant Enclosure

1370 DC Loop Contactors and Lug Kits

4CR SERIES MOTOR STARTING RELAY All Position, Current-Type

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

Kinetix 350 Single-axis EtherNet/IP Servo Drives

Programmable Logic Controller. Mat Nor Mohamad

Installing the Boom Mount ET 350 Monitor (Model ET 350R)

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

Medium Voltage Drive Harmonic Filter and Power Factor Correction Units. User Manual. Bulletin volts hp

Preventive Maintenance Checklist of Industrial Control and Drive System Equipment

J lh. NEMA AC Contactors for Motor Loads (Bulletin 500) and Non-motor Loads (Bulletin 500L) Sizes 0 through 4 (all series), Size 5 (series L)

Slip Ring Connection Board Version 1.0 User s Manual

NHP SAFETY REFERENCE GUIDE

DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data

1494U Visible-Blade Disconnect Switch

Thermal Overload Relays

Control and Load Switch Specifications Bulletin Number 194E, 194L

MANSI CLS Series LPG/CNG Closed Loop System with Harness and Actuator Motor

Updated: October 2012

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101

Medium Voltage 400A Contactor - Series E and F Allen-Bradley Parts

Rotary Disconnect Switches, Bulletin 194R

Cable-Operated Disconnect Switches. Accessories

G3PE-Single-phase. Solid State Relays for Heaters

PowerFlex 6000 Medium Voltage AC Drives

Replacement Parts List

Circuit breaker interlocking and operation requirements SIEMENS

Kinetix 300 Single-axis Servo Drives

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

PREVIEW ONLY - FULL COPY AVAILABLE TO CONSORTIUM MEMBERS. Escalator Specific Electrical Systems. Course 209 PARTICIPANT GUIDE

Product Instruction. Door Control Board: Board 1Ø4 for PM/SSC (R3)

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Martin Tornado Retrofit Valve

DAP-625S and DAP-875S

Relay Retrofit Program Cutting Tool Safety Guide

2AM/3AM/4AM/8AM SERIES Motor Protector

Intel Server Chassis and Platform Bracket Kit Installation Guide

Pump Panel Specifications

BIG BLASTER XHV Air Cannon Retrofit with MARTIN TORNADO Exhaust Valve

SPECIFICATIONS NB SKILLS TRADE 19 AUTOMATION AND CONTROL

CENTERLINE 2100 Motor Control Centers 600A, 800A, and 1200A Bolted Pressure Contact Switch

II DISTRIBUTION & SUBSTATION TYPE C

HV angle valve with single acting pneumatic actuator and closing spring (NC)

Disconnect Combiner Box Installation Manual

Electric Motor Controls BOMA Pre-Quiz

Typical Specification

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION

Installation Instructions. PowerFlex 700 Drive - Frame 7 Components Replacement

Position Switch Kits Accessory Kits for EntelliGuard* Retrofill Circuit Breakers

Product Guide. enclosed NEMA STARTERS

SPC-PANEL Simplex, Single Phase Pump Control Panel

MaxLite LED Linear HighBay Fixtures

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF65 and TF96

Aluminum Electrolytic Capacitors Power Ultra Miniature Snap-In

Selection Guide. PowerFlex Digital DC Drive

CENTERLINE 2500 Low Voltage Motor Control Centers and Power Distribution Gear Catalog Structure Breakdown

Pump Installation and Service Manual HRS Hydromatic Retractable System

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Electronic overload relays EF205 and EF370

Contactor Combiner Box Installation Manual

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

MEX (55) QRO (442) Web Controls

Aluminum Electrolytic Capacitors Power Ultra Long Life Snap-In

Nortec EL SPARE PARTS LIST. Contents. IMPORTANT! This document to be left with the equipment.

Medium Voltage 400A Contactor - Series E and F

Aluminum Electrolytic Capacitors Power Ultra Long Life Snap-In

Patient Care Facility

Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton

SECTION ENCLOSED CONTROLLERS

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

THE BULLETIN 509 ASSEMBLY GUIDE - Features and Benefits

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Ktec Contactors and thermal overloads

1/2" (12.7 mm) Conductive Plastic and Cermet Potentiometer

Q-Series Stealth Winch

Relay Retrofit Program for REX 521 Cutting Tool Safety Guide

Power Distribution Units

THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Transcription:

Page 1 of 7 Knowledgebase Technote ID # Q18363 9/2/2003 505 Series A Construction 505 505 1495-F1 (1 N.O. auxiliary contact) 1495-G5 (1 N.C. early break auxiliary contact) 1495-H0 ( 1 N.C. late break auxiliary contact)

Page 2 of 7 Knowledgebase Technote ID # Q18363 9/2/2003 4

Page 3 of 7 Knowledgebase Technote ID # Q18363 9/2/2003 505 Size 5 Series A Construction With Overload Relays Without Overload Relays Item Part Description Left-Hand Contactor Right-Hand Contactor Both Contactors No. Part Number Part Number Part Number 1 Stationary Contact Block (less contacts, less spacer, less X-277415 X-277415 X-277415 cover) 2 Stationary Contact Block Spacer F-20477 F-20477 F-20477 3 Stationary Contact Block Cover X-232815 X-232815 X-232815 4 Movable Contact Support Assembly (less contacts and F-20798 F-20798 F-20798 springs) 5 Yoke and Armature Assembly (60-50Hz) Z-31852 Z-31852 Z-31852 (includes yoke/armature retainers and spring) Yoke and Armature Assembly (25Hz) Z-31856 Z-31856 Z-31856 (includes yoke/armature retainers and spring) 6 Yoke (60-50Hz) Yoke (25Hz) Purchase complete yoke and armature Purchase complete yoke and armature assembly Purchase complete yoke and armature 7 Armature (60-50-25Hz) assembly (item 5) assembly (item 5) 8 Yoke Retainer F-20478 F-20478 F-20478 9 Armature Retainer F-20479 F-20479 F-20479 10 Retainer Spring B-29481 B-29481 B-29481 11 Coil Cover with Normally Closed Interlock Contact Z-21144 Z-21144 Z-21144 Coil Cover with Normally Open Interlock Contact Z21145 Z21145 Z21145 Coil Cover with Normally Open-Normally Closed Interlock Contact (comes as standard on the device) Z-21146 Z-21146 Z-21146 Coil Cover without Interlock Contacts Z-21147 Z-21147 Z-21147 12 Rear Stationary Contact Assembly Order Single Pole Order Single Pole 13 Front Stationary Contact Assembly Contact Set Contact Set 14 Movable Contact (qy 6 req d per device) (qty 6 req d per device) 15 Movable Contact Spring 12-15 Single Pole Contact Set (includes one[1] Front and Rear Stationary Contacts, Movable Contact and Movable Contact Spring Order Single Pole Contact Set (qty 6 req d per device) Z-34043 Z-34042 Z-34042 16 Current Transformer Spring (qty 3 req d) B-31520 Not Used Not Used 17 Current Transformer (300 to 5 amp ratio) (qty 3 req d) X-241563 Not Used Not Used 18 Mechanical Interlock Assembly Z-19134 Z-19134 Lug X-314129 X-314129 X-314129 Lug Bolt M-422 M-422 M-422 Heater Element Screw M-1552 Not Used NOTE: Current transformers and transformer springs are not included on the stationary contact block assemblies or in any of the single pole contact sets. These parts must be ordered separately.

Page 4 of 7 Knowledgebase Technote ID # Q18363 9/2/2003 Not Available Overload Relay Not Available Not Available Parts information on page 5 (order separately) (order separately) Heater Element Screw M-1552

Page 6 of 7 Knowledgebase Technote ID # Q18363 9/2/2003

Page 7 of 7 Knowledgebase Technote ID # Q18363 9/2/2003 Important User Information Because of the variety of uses for the products described in this publication, those responsible for the application and use of this control equipment must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Rockwell Automation does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication. Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Allen-Bradley office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication. Reproduction of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is prohibited. Throughout this document we use notes to make you aware of safety considerations: ATTENTION Identifies information about practices or circumstances that can lead to personal injury or death, property damage or economic loss! IMPORTANT Identifies information that is critical for successful application and understanding of the product. Use only replacement parts and devices recommended by Rockwell Automation to maintain the integrity of the equipment. It is the user s responsibility to ensure that the renewal part number selected is properly matched to the model, series and revision level of the equipment being serviced. ATTENTION! Servicing energized Industrial Control Equipment can be hazardous. Severe injury or death can result from electrical shock, burn, or unintended actuation of controlled equipment. Recommended practice is to disconnect and lockout control equipment from power sources, and release stored energy, if present. Refer to National Fire Protection Association Standard No. NFPA70E, Part 2 and (as applicable) OSHA rules for Control of Hazardous Energy Sources (Lockout/Tagout) and OSHA Electrical Safety Related Work Practices for safety related work practices, including procedural requirements for lockout/tagout, and appropriate work practices, personnel qualifications and training requirements where it is not feasible to de-energize and lockout or tagout electric circuits and equipment before working on or near exposed circuit parts. ROCKWELL DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED IN RESPECT TO THE INFORMATION (INCLUDING SOFTWARE) PROVIDED HEREBY, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, AND NON-INFRINGEMENT. Note that certain jurisdictions do not countenance the exclusion of implied warranties; thus, this disclaimer may not apply to you. Allen-Bradley is a trademark of Rockwell Automation