Instruction Manual. Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators. No Rev

Similar documents
RAMSET

RAMSET RAM

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

FOR CLASS I VEHICULAR GATE OPERATORS

RAM TABLE OF CONTENTS

Eagle Access Control Systems, Inc. / (800) / (3)

INSTALLATION M ANUAL

RAM

ontrol Systems, Inc. Swing Gate Installation Manual Eagle-200 Series Eagle-100 Series UL325 and UL991 Compliant

Owner s Manual. Model 9150 Vehicular Slide Gate Operator

Owner s Manual. Model 9100 Vehicular Slide Gate Operator

Installation/Owner s Manual Model 9050

Owner s Manual. Model 9300 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 9150

COMMERCIAL 24VDC HIGH TRAFFIC OVERHEAD DOOR AND GATE OPERATOR WITH BATTERY BACKUP INSTALLATION MANUAL

Installation/Owner s Manual Series 9000

Installation/Owner s Manual Model 9100

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator

Owner s Manual. Overhead Gate Operator. Copyright 2015 DoorKing, Inc. All rights reserved. REV SENSE OPEN GATE FORCED NO NC

Owner s Manual. Model 9310 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 9000 Vehicular Slide Gate Operator

Installation/Owner s Manual Series 6500

Installation/Owner s Manual Series 6500

Installation/Owner s Manual Model 9100 Vehicular Slide Gate Operator

AC Powered. AC Powered. Installation/Owner s Manual Model AC Powered Vehicular Slide Gate Operator

AC Powered. AC Powered. Model Installation/Owner s Manual. UL 325 Compliant. AC Powered Vehicular Swing Gate Operator

Owner s Manual. Models 6050 and 6100 Vehicular Swing Gate Operators

PowerMaster Model SG

Owner s Manual. Series 6300 Vehicular Swing Gate Operators

Installation/Owner s Manual Series 9500

RAMSET.

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

115 VAC Control Boxes for

Installation/Owner s Manual

AC Powered. AC Powered. Model Installation/Owner s Manual. AC Powered Vehicular Swing Gate Operator. UL 325 August 2018 Standard

115 VAC Control Boxes for

MODEL MSW Medium Duty Swing Gate Operator

PowerMaster. Installation Manual UL 325 AND UL 991 LISTED MODEL RSG TABLE OF CONTENTS

UGP-712 Vehicular swing gate operator

Installation/Owner s Manual 9245

115 VAC Control Boxes for

gate operator class categories and examples

Installation/Owner s Manual

Sliding Gate Opener User s Manual

Actuator Arm and Control Box Mounting

Owner s Manual. Series 6050 and Vehicular Swing Gate Operator. Copyright 2010 DoorKing, Inc. All rights reserved. WARNING


FSW 900 Swing Gate Operator

Installation/Owner s Manual

Solar Powered. Solar Powered. Model Installation/Owner s Manual. Solar Powered Vehicular Swing Gate Operator

Installation/Owner s Manual

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING H-10 GATE OPERATOR

Solar Powered. Solar Powered. Installation/Owner s Manual Model UL 325 Compliant. Solar Powered Vehicular Slide Gate Operator

Solar Powered. Solar Powered. Installation/Owner s Manual Model Solar Powered Vehicular Slide Gate Operator

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FO T E VIKING 10 GATE OPE ATO

MODEL SL930 HEAVY-DUTY COMMERCIAL DC SLIDE GATE OPERATOR

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING Q-7 GATE OPERATOR

TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 ACCESSORY WIRING 29 INTRODUCTION 5 EXPANSION BOARD 31 INSTALLATION 9

Actuator Arm and Control Box Mounting

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2 GATE OPERATOR

Solar Control Box for

Vehicular Gate Operator Class I, Class II, Class III, and Class IV

Solar Control Box for

APOLLO Gate Operators, Inc.

MODEL D-SBG Single Arm Barrier Gate Operator

APOLLO Gate Operators, Inc.

MODEL WBG WISHBONE BARRIER GATE OPERATOR

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2 GATE OPERATOR. CLASS I Residential Vehicular Slide Gate Operator

For Classes I, II, III, IV

Vehicular Swing Gate Operator. Nice. Titan 912L. The Titan 912L Gate Operator is intended for use with vehicular swing

TABLE OF CONTENTS WARNINGS GENERAL INFORMATION INSTALLATION INSTRUCTIONS OPERATING INSTRUCTIONS ACCESSORY CONNECTIONS MOTOR CONTROL SCHEMATIC

Installation/Owners Manual PATRIOT RSL Vehicular Slide Gate Operator Heavy Duty Battery Powered Solar or AC Charged

Installation/Owner s Manual 6400 Vehicular Swing Gate Operator

MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR

MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR

MODEL D-WBG Wishbone Arm Barrier Gate Operator

MODEL SL585 MODEL SL595 HEAVY DUTY SLIDE GATE OPERATOR HEAVY DUTY, HARSH ENVIRONMENT SLIDE GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD

INSTALLATION MANUAL MODEL LA412 RESIDENTIAL DC SOLAR VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant. LA4121PKGDC Single Arm Package

IQ Gate Systems. IQ-500 Installation And Instruction Manual UL 325 and UL 991 Compliant.

Installation Instructions and Safety Information Manual: Vehicular Gate Operator Class I, Class II, Class III, and Class IV

SKC400U SLIDING GATE OPENER OWNER S MANUAL

OWNER S MANUAL GP-SL050. With Inherent UPS Battery Back-up System

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Model 1550 Single Swing Gate Model 1650 Dual Swing Gate

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

VIKING. installation instructions and safety information

Installation/Owner s Manual 1601 / 1602

vehicular gate operator installation instructions and safety information revision B1 february 2007 CLASS I, CLASS II, CLASS III and CLASS IV

INSTALLATION INSTRUCTIONS NEW IMAGE AND SAFETY INFORMATION FOR THE VIKING K-2S GATE OPERATOR. CLASS I Solar Residential Vehicular Slide Gate Operator

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING F-1 GATE OPERATOR

MODEL SW470 MEDIUM DUTY SWING GATE OPERATOR

INSTALLATION INSTRUCTIONS AND SAFETY INFORMATION FOR THE VIKING G-5 GATE OPERATOR SINGLE AND DUAL GATE SYSTEMS

AUTOMATIC GATE OPENER

MODEL SW470 MODEL SW490 MEDIUM DUTY SWING GATE OPERATOR HEAVY DUTY SWING GATE OPERATOR 2 YEAR WARRANTY CONTROLLER BOARD

INSTALLATION MANUAL MODEL LA500 LIGHT COMMERCIAL - RESIDENTIAL DC VEHICULAR SWING GATE OPERATOR. UL991 compliant. UL325 compliant

Installation/Owner s Manual 1601 / 1602

TABLE OF CONTENTS SAFETY SAFETY SYMBOL AND SIGNAL WORD REVIEW SAFETY 1 OPERATION 31 INTRODUCTION 5 ACCESSORY WIRING 34 INSTALLATION 9 MAINTENANCE 36

Transcription:

Rev 060202 Instruction Manual Model RAM-1000 UL & RAM-5500 UL For Class I, II, III, IV Vehicular Gate Operators C No. 545327 US

TABLE OF CONTENTS Important Safety Requirements & Instructions.......................................1,2 Mechanical Specifications......................................................3 Installation Specifications.......................................................4 Pad Construction.............................................................4 Recommended Wire Gauge / Voltage Drop Chart....................................5 Gate Travel Adjustment........................................................6 Pushbutton Controls...........................................................6 Electrical Connection..........................................................7 INTELLIGATE PCB MOTOR CONTROLLER SPECIFICATION Introduction..............................................................8 DIP Switch Configurations...................................................8,9 TERMINAL STRIP CONNECTIONS...........................................9 Wiring Diagram..............................................................10 Sensor Installation............................................................11 Master - Slave Installation......................................................11 Bill of Materials...............................................................12 RAM-1000 UL Parts Diagram....................................................13 RAM-5500 UL Parts Diagram....................................................14 Glossary....................................................................15 IMPORTANT SAFETY REQUIREMENTS & INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the Vehicular Gate Operator monthly. The gate MUST reverse on contact with a rigid object or stop when an object activates the non-contact sensors. After adjusting the limit of travel, retest the Vehicular Gate Operator. Failure to adjust and retest the Vehicular Gate Operator properly can increase the risk of injury or death. 5. Use the Emergency Release only when power switch or circuit breaker has been turned off. Using the Emergency Release during a power failure can be a hazard if power is abruptly restored. 6. KEEP GATES PROPERLY MAINTAINED. Read the Owner's Manual. Have a qualified service person make repairs to gate hardware. 7. The entrance is for vehicles only. Pedestrians must use separate entrance. 8. SAVE THESE INSTRUCTIONS. NOTE: Always consult and follow all local building and electrical codes prior to installation. Ramset Gate Operators should not be installed without non-contact sensing devices such as non-contact sensors, photo electric sensors or the equivalent. WARNING A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge device or equivalent) is required on each individual installation to comply with UL325. Reversing Sensors (Loop Detectors) Reversing Sensors should be used to prevent gate from closing when a vehicle is in the gate area. - 1 -

Installation should be done by a qualified installer only. Prior to Installation, the following must be observed: (per UL 325 51.8.4) a) Install the vehicular gate operator only when: 1) The Vehicular Gate Operator is appropriate for the construction of the gate and the usage Class of the gate, 2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m) above the ground to prevent a 2-1/4 inch (57.15 mm) diameter sphere from passing through the openings anywhere in the gate, and in that portion of the adjacent fence that the gate covers in the open position. 3) All exposed pinch points are eliminated or guarded, and 4) Guarding is supplied for exposed rollers. b) The Vehicular Gate Operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. c) The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when opening and closing to reduce the risk of entrapment. Swinging gates shall not open into public access areas. d) The gate must be properly installed and work freely in both directions prior to the installation of the Vehicular Gate Operator. Do not over-tighten the operator clutch to compensate for a damaged gate. e) Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Controls intended to be used to reset a Vehicular Gate Operator after 2 sequential activations of the entrapment protection device or devices must be located in the lineof-sight of the gate. Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use. f) All warning signs and placards must be installed where visible in the area of the gate. g) For Vehicular Gate Operators utilizing a noncontact sensor in accordance with 30A.1.1 Type B1 non-contact sensor (photo electric sensor or the equivalent) 1) See instructions on the placement of non-contact sensors for each Type of application, 2) Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle, trips the sensor while the gate is still moving, and 3) One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier. h) For a Vehicular Gate Operator utilizing a contact sensor in accordance with 30A.1.1 1) One or more contact sensors shall be located at the leading edge, trailing edge, and postmounted both inside and outside of a vehicular horizontal slide gate. 2) One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. 3) One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate. 4) A hardwired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the vehicular gate operator is not subjected to mechanical damage. 5) A wireless contact sensor such as one that transmits radio frequency (RF) signals to the vehicular gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions. - 2 -

MECHANICAL SPECIFICATIONS: Model: RAM-1000 UL RAM-5500 UL Power Input: 120VAC 120VAC Continuous Duty Motor: 1/2 HP, 120VAC, 4.5 A, 1,625 RPM with High Speed Bearings 3/4 HP, 120VAC, 8.5 A, 1,625 RPM with High Speed Bearings Capacitor: Aerovox 65µƒ, 240 V, 50/60 HZ, protected S Aerovox 65µƒ, 240 V, 50/60 HZ, protected S 10000 AFC 10000 AFC Cycles: Continuous Continuous ON/OFF Switch: 120 VAC & 2 outlets 120 VAC & 2 outlets Max Gate Length: 35 ft. 45 ft. Max Gate Weight: 1000 lbs 1500 lbs Gate Travel Speed: 12 inches per second 12 inches per second Reduction: By worm gearbox continually lubricated in an By worm gearbox continually lubricated in an oil bath. oil bath. Finish & Chassis: Rust-preventing Gold/Zinc coated 3/16" sheet Rust-preventing Gold/Zinc coated 3/16" sheet metal metal Gate Stops: with limit switches with limit switches Chain: 20 ft. of Nickle-plated chain to inhibit corrosion 20 ft. of Nickle-plated chain to inhibit corrosion Cover: Polyethylene, high-impact resistance Polyethylene, high-impact resistance Color: Charcoal Gray Charcoal Gray Emergency Release: Depress foot pedal release to disengage gate from motor so it can be opened manually in the event of an emergency. An optional battery backup system is also available. Shipping Weight: 95 lbs. 110 lbs. Overall Dimensions: W=13-1/2", D=14-1/2", H=22" W=16-1/2", D=14-1/2", H=26" RAM-1000 UL RAM-5500 UL 1/2 HP MOTOR 3/4 HP MOTOR foot pedal release foot pedal release - 3 -

INSTALLATION SPECIFICATIONS These Sliding Gate Operators are factory preset for Left Hand Installations. PAD CONSTRUCTION: Dimensions given for pad are based on soil bearing shear of 2000 P.S.F. These figures may have to be adjusted depending on local soil condition. Figure 1 4 MIN 1. Construct form for mounting pad according to dimensions shown on this page. 2. Locate mounting pad according to dimensions given in illustration. 3. Level top edge of form. 4. Set reinforcing bars and wire mesh. 6 MIN 6-1/2 WALL 5. Mix concrete; pour mixture into form. Tamp mixture. Level and finish surface after pouring is complete. 6. Allow pad to cure 48 hours, and remove forms. 4 Low voltage control wires must be run in a separate conduit to the operator. 24 6-1/2 Figure 2 4 4 MIN LH installation gate shown closed Gate LC 24 Wall 6 Conduit for low voltage wires Figure 3 Conduit for power Conduit for Master-Slave LH installation gate shown open Wall 18 x 18 x 24 Concrete Pad 4 MIN 4-1/2 B 18 concrete Gate LC Mark centers and install four 1/2-13 UNC Red-head Anchor Bolts A 18 concrete C MODEL Dim "A" Dim "B" Dim "C" Dim "D" Dim "E" RAM-1000 UL 13-3/4" 8-1/2" 2-1/8" 14" 8-1/2" RAM-5500 UL 13.902 8.625 or 6.625 2.049 8.5 13.875-4 -

Figure 4 E D 6 min. 24 Concrete Pad Dim D minus distance determined by pulleys Rear Installation Gate Shown Fully Open 18 x 18 No tail on gate required E D 6 min. Figure 5 Concrete Pad Center Installation Gate Shown Fully Open No tail on gate required 2-1/2 diameter UHMW Pulley Low voltage control wires must be run in a separate conduit to the operator. RECOMMENDED WIRE GAUGE / VOLTAGE DROP CHART MAXIMUM CONDUIT DISTANCE IN FEET AMPERES USING COPPER WIRE BY WIRE SIZE INPUT POWER MOTOR HP RUN START 14 GA 12 GA 10 GA 8 GA 120V Single Phase 1/2 4.7 5.0 up to 50' 50-100' 100-200' 200-300' 120V Single Phase 3/4 5.8 6.5 up to 50' 50-100' 100-200' 200-300' - 5 -

GATE TRAVEL ADJUSTMENT To adjust gate travel, depress spring loaded bracket and spin each Adjustment Nut to the required position (Figure 6). LED must turn on to indicate position open or close when limit switch is activated by limit switch adjustment nut. Limit Switches Figure 6 Adjustment Nuts Depress spring loaded bracket to free Adjustment Nuts. TURN POWER OFF BEFORE ATTEMPTING ADJUSTMENT PUSHBUTTON CONTROLS Three pushbuttons (Figure 7) are located under the dip switches for manual operation of the gate. The open, stop, and close buttons can be utilized to set limit switches and verify proper system operation when installing or servicing an operator. Open Pressing this button will cause the gate to open. Stop Pressing this button will cause the gate to stop moving. Close Pressing this button will cause the gate to close. L.E.D. s light up when function is activated Figure 7 OPEN STOP CLOSE - 6 -

ELECTRICAL CONNECTION A 3 wire, 120VAC electrical circuit with a 15 amp independent circuit breaker is required for each operator. Ideally, the electrical conduits should exit the concrete under the operator. Low voltage control wires must be run in a separate conduit to the operator as shown. Intelligate Control Board: The Control Board is completely solid state. L.E.D. readouts show the status of the operator and control systems allowing for instant troubleshooting. The PCB circuitry plugs into an edge connector eliminating the need to disconnect any wires when replacing the board. WARNING ALWAYS TURN OFF POWER WHEN SERVICING OPERATOR! CAUTION Check that gate is clear of people or obstructions BEFORE turning power ON to avoid injury. JP2 FULLY OPEN FULLY CLOSED ALARM MAIN CPU CHIP JP5 60 SECS 1 1 1 45 SECS 1 1 0 30 SECS 1 0 1 15 SECS 1 0 0 10 SECS 0 1 1 5 SECS 0 1 0 0 SECS 0 0 1 DISABLED 0 0 0 ADDRESS 1 ADDRESS 0 MECH LOCK DOOR-IN-DOOR HIGH ERD SENS SECURE CLOSE MOM. SOS RADIO CYCLE ONE PASS LAG DELAY LAG MODE REVERSE LOGIC SLAVE MODE 1/2 A 10 A JP7 M1 M2 JP6 OPEN STOP CLOSE A B COMMON REVERSE FIREBOX EXIT PHANTOM ON ( A ) ( B ) CLOSE RADIO STOP LIMIT 1 LIMIT 2 COMMON COMMON 24V RECT MAG ( - ) MAG ( + ) SOLENOID MOTOR 1 MOTOR 2 AC HOT NEUTRAL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Figure 8 TO RECEIVER TO LIMIT SWITCHES TO MOTOR TO 120VAC - 7 -

INTELLIGATE PCB MOTOR CONTROLLER SPECIFICATIONS INTRODUCTION Ramset s Intelligate Control board is for operating a vehicular gate operator. The control board is available for either 110VAC or 220VAC, single phase, applications. The control board contains self adjusting ERD, left hand/right hand operation control, lead/lag capability, one-pass anti-tailgating, and options for 4 different gate addresses. The control board also includes a rectified 24V, 750mA, output for providing power to peripheral devices such as radio receivers, keypads, alarms, phone entry systems, safety detectors etc. DIP SWITCH CONFIGURATION Dip Switch A1 3: Automatic Timer to Close Gate DIP GATE OPEN DURATION 111 60 seconds 110 45 seconds 101 30 seconds 100 15 seconds 011 10 seconds 010 5 seconds 001 0 seconds 000 disabled command required to close 60 SECS 1 1 1 45 SECS 1 1 0 30 SECS 1 0 1 15 SECS 1 0 0 10 SECS 0 1 1 5 SECS 0 1 0 0 SECS 0 0 1 DISABLED 0 0 0 Dip Switch A4 5: ADDRESS 1 & ADDRESS 0 Up to four separate entrance addresses are available for installations with multiple entrance or exit locations. Master and slave gates that work together should be set to the same address. (Side gates use the address setup) DIP FUNCTION 00 Default Entrance 1 01 Entrance 2 10 Entrance 3 11 Entrance 4 Dip Switch A6: MECH. LOCK Mechanical Lock For motor assemblies that use a mechanical lock mechanism. DIP off on FUNCTION no effect ADDRESS 1 ADDRESS 0 MECH LOCK DOOR-IN-DOOR LOW-ERD-HIGH SECURE CLOSE MOM. SOS RADIO CYCLE ONE PASS LAG DELAY LAG MODE REVERSE LOGIC SLAVE MODE Figure 9 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Dip Switch A Dip Switch B Solenoid output, on the terminal strip is used to disengage the mechanical lock prior to actuating the motor in either direction. ON DIP SWITCH A7: DOOR-IN-DOOR Door-In-Door Used with a three button switch or a pedestrian entranceto stop the gate. DIP FUNCTION off on normal operation normally closed contact. With an open contact the board will stop the gate from moving until a close contact is reached. DIP SWITCH A8: LOW - ERD - HIGH ERD Sensitivity DIP FUNCTION off Normal ERD sensitivity Adjusts the ERD for standard sensitivity. on Adjusts the ERD sensitivity so that more pressure is needed to stop the gate. (recommended: only use in windy areas) DIP SWITCH B1: SECURE CLOSE Secure Close DIP FUNCTION off Normal operation on When power is lost, then regained, control board checks status of gate. If open and safety devices are cleared, gate will close automatically. *WARNING* When installing or servicing an operator, make sure switch is off. If switch is on gate will move when power is applied and severe injury may occur. DIP SWITCH B2: MOM. SOS SOS Maintained/Momentary (Uses Firebox input) DIP off on FUNCTION Maintained contact closure normal operation, releases when contact closure is cleared. Momentary contact closure releases only after a second closed contact signal is received. DIP SWITCH B3: RADIO CYCLE DIP FUNCTION off Normal operation gate only opens and closes on the limit switches. If the gate is in travel then it will always open. on Cycle mode gate opens and closes on the limit switches, but if in travel, then it will stop with a first command and reverse with a second command. DIP SWITCH B4: ONE PASS DIP FUNCTION off Normal operation - fully opens and closes on One pass mode - The gate will open until the "reversing loop" is initially activated and then cleared. The gate will then close. If the "reversing loop" is then activated again, before the gate is fully closed, the gate will stop until the "reversing loop" is cleared, then continue to close. - 8 -

DIP SWITCH B5: LAG DELAY Lag on Close One second lag on close DIP SWITCH B6: LAG MODE Lag on Open One second lag on open DIP SWITCH B7: REVERSE LOGIC DIP FUNCTION off Left hand operation standard installation on Right hand installations Reverses motor & limit switches without having to move any wires. DIP SWITCH B8: SLAVE MODE Master/slave DIP FUNCTION off Master mode single gate operation. All peripheral devices are to be connected to the master operator. on Slave mode used to synchronize operation between two gates. Commands are received from the master through a 3-wire, shielded cable. TERMINAL STRIP CONNECTIONS CONTROL INPUT DESCRIPTIONS Note: if both B5 & B6 are 'on', there will be NO lag on the open or close. AC Hot & Neutral 110 or 220 VAC to power the operator. Voltage is predetermined at factory and cannot be changed by the installer or technician. Close Closes the gate. Used with three button stations or pushbuttons. Becomes active with a closed contact to common. Exit Opens the gate. Used with loop detectors, photo eyes, keypads, phone entry systems, three-button stations etc. Becomes active with a closed contact to common. Firebox/SOS Opens the gate. Used with fire dept. key switches & controls. Becomes active with a closed contact to common, maintained or momentary depending on dip switch B2 (see dip switch features ). Stop Stops the operator from moving. To be used as a non-contact sensor such as a photo-beam, edge connector or a three-button station. Becomes active with an open contact to common when dip switch A7 is in the on position (see dip switch features ). Radio Operation depends on dip switch B3 (see dip switch features ). Used with an RF receiver or pushbutton. Becomes active with a closed contact to common. SAFETY INPUT DESCRIPTION Limit 1 & Limit 2 Depending on dip switch B7 (see dip switch features ), stops the motor from moving in one direction. These wires are preset in factory and should not be moved. Becomes active with a closed contact to common. Phantom Keeps the gate open when the open limit switch (A or B) is activated. Used with loop detectors. Becomes active with a closed contact to common. Rev Loop Stops the gate from closing. If the gate is open, it holds the gate open. If the gate is closing, it stops and reopens the gate. If the gate is closed, the gate will remain closed. The function can be altered with dip switch B4 (see dip switch features ). Used with loop detectors, photo eyes, safety edges etc. Becomes active with a closed contact to common. OUTPUTS Mag (+) & Mag (- ) Supplies 24VDC to a magnetic lock when gate is closed. If gate is not closed then no power is supplied. Leave open if not used. Motor 1 & Motor 2 Supplies power to the motor. Direction depends on dip switch B7 (see dip switch features ). These wires are preset and connected in the factory and should not be moved. 24V Rect. Provides a rectified 24VDC for peripheral accessories. Solenoid Sends 110 VAC to a solenoid or other mechanical lock. Leave open if not used. OTHER CONNECTIONS Contact Closure Relay Outputs Three separate isolated form-c relay outputs are provided. Each relays contact is rated at 125VAC, 2 amps. 1. Alarm When ERD is triggered twice, before reaching a fully closed or fully opened position, 24VDC is supplied for 6 minutes and the control board will not accept any commands. After the 6 minutes the 24VDC is removed and the board resets to normal operation. 2. Triggers relay when gate is fully opened. Used with indicator lights, buzzers, beepers, misc. voltage magnetic locks etc. 3. Triggers relay when gate is fully closed. Used with indicator lights, buzzers, beepers, misc. voltage magnetic locks etc. - 9 -

CAUTION Electronic Control Board must be serviced by a certified technician only. Power must be turned OFF before servicing operator. Power must be turned OFF before attempting to adjust the limit switches. Power must be turned OFF for power failure release. Figure 10 COMMON REVERSE LOOP CLOSE FIREBOX EXIT PHANTOM RADIO STOP LIMIT 1 LIMIT 2 WIRING DIAGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMON COMMON 24V RECT MAG ( - ) MAG ( + ) SOLENOID MOTOR 1 MOTOR 2 AC HOT NEUTRAL WH TO NEUTRAL Phantom Loop WH BK BK POWER SWITCH TO 120VAC BK RD BK Firebox Pedestrian Switch N.C. Contact WH YL BK Radio Terminal Strip WH BL RD N.O. C N.C. Limit Switch N.O. Mag Lock C N.C. Limit Switch Solenoid RD Capacitor RD BL BL WH 120V AC or 220V AC Exit Loop Open Stop Close Common 3 button station Motor GR Reversing Loop 4 Wire Radio Receiver Gray Black Gray Red 1 2 3 Radio Terminal Strip White Yellow Black 12 - Common 7 - Radio 13-24V RECT 3 Wire Radio Receiver 1 2 3 White 12 - Common Yellow 7 - Radio Black 13-24V RECT Legend RD = Red WH = White BL = Blue GR = Green (Ground) BK = Black YL = Yellow - 10 -

SENSOR INSTALLATION WARNING A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge device or equivalent) is required on each individual installation to comply with UL325. Reversing Sensors on the ground floor prevent gate from closing when vehicle is in loop area. Exit Loops on the ground floor opens gate when vehicle crosses loop area. Outside Property Reversing Loop 3 feet min 4 feet min 3 feet min Inside Property Primary Operator is factory pre-set for LH operation Twist wires outside of loop Do not twist wires inside loops. 1/4" Reversing Loop Exit Loop 3 feet min 4 feet min 4 feet min Figure 11 1-1/2" 6 feet min typical 2-4 feet Figure 12 Master - Slave Installation Set Dip Switch Slave Mode to ON for Slave Operator. RH operation requires Dip Switch Reverse to be ON. REVERSE LOGIC SLAVE MODE ON JP6 Use jumper JP6 to JP6 Use jumper JP6 to JP6 JP6 Use 3-stranded, shielded wires (not supplied) from Master to Slave. Route low-voltage wires for Master/Slave in a conduit separate from power. - 11 -

BILL OF MATERIAL FOR RAM-1000 UL AND RAM-5500 UL ITEM PART # PART DESCRIPTION RAM-1000 UL RAM-5500 UL 1 50-031 1/2 hp 115 vac electric motor 1 2 50-039 20 pin edge connector 1 1 3 50-058 3 1/2" uhmw idler pulley 2 2 4 50-069 limit switch 00-h3 2 2 5 50-087 # 41 x 20' gate chain 1 1 6 50-089 3/8" x 2" x 6" chain bracket 2 2 7 50-090 1/2" x 4" chain bolt 2 2 8 50-091 # 6 x 1" machine screw 2 2 9 50-092 3/8-16 x 1 1/4" hex head bolt 4 4 10 50-095 5/16-18 unc x 3/4" hex head bolt 2 2 11 50-097 5/16" flat washer 2 2 12 50-098 5/8"-11 x 3 1/2" hex head bolt 2 2 13 50-099 5/8" flat washer 2 2 14 50-101 3/8" lock washer 8 8 15 50-103 3/8" hex head nut 4 4 16 50-105 # 6 hex head nut 4 4 17 50-106 5/8" hex head nut 4 4 18 50-107 # 6 x 3/8" machine screw 3 3 19 50-113 1/2" hex head nut 4 4 20 50-114 1/4-20 socket head screw 4 4 21 50-145 1/2" x 3" tension spring ( pedal ) 1 1 22 50-151 warning sing for gate 2 2 23 50-168 horn alarm 1 1 24 50-208 limit switch nuts 2 2 25 50-212 1" tension spring 2 2 26 50-215 rocker switch 1 1 27 50-240 3/16" hot -roll metal 1 28 50-242 speed reducer size 60 1 29 50-244 polyethylene cover 1 30 50-245 limit switch chain 1 31 50-246 1" x 7" limit switch shaft 1 32 50-247 3/4" ball bearrings 2 2 33 50-248 4 pin disc release 1 1 34 50-249 1" arbor release 1 1 35 50-250 41 b 27 clutch release sprocket 1 1 36 50-251 41 b 12 x 3/4" sprocket 1 1 37 50-252 board metal cover 1 38 50-253 3/4" shaft collar 2 2 39 50-254 spring load bracket 1 40 50-256 3/4 HP 120 VAC electric motor 1 41 50-264 1/4" x 1-1/2" key way 1 1 42 50-265 3/16" x 3/4" key way 1 1 43 50-295 #8 self-tap sheet metal screw 2 2 44 50-299 radio receiver terminal 1 1 45 50-501 3/16" hot rolled metal chassis 1 46 50-502 board metal cover 1 47 50-503 polyethylene cover 1 48 50-504 speed reducer size 50: 30:1 ratio 1 49 50-505 1" x 6" limit switch shafth 1 50 50-506 spring load bracket 1 51 50-510 outlet switch cover 1 1 52 50-511 120 vac double outlet 1 1 53 50-513 1/4" X 3/4" counter sinc bolt 2 2 54 50-514 pedal release fork 1 1 55 50-515 limit switch chain 1 56 50-516 3/16" clutch release spring 2 2 57 50-517 1/4" x 3/8 sink screw 2 2 58 50-518 1-1/2" external snap ring 1 1 59 50-519 3/8" x 1-1/2" carriage bolt 4 4 60 50-520 # 6 x 5/8" machine screw 4 4 61 50-540 5/16" lock nut 2 2 62 50-528 # 8 X 3/8" macine screw 4 4 63 50-777 inteligate control board 1 1-12 -

47 RAM-1000 UL PARTS DIAGRAM 22 12 13 3 58 Figure 13 6 17 7 19 35 34 57 5 56 33 43 44 1 16 4 42 36 53 54 41 48 59 20 32 14 38 49 15 8 23 55 25 24 62 58 50 46 18 20 11 45 60 2 63 26 52 51 21 61-13 -

29 RAM-5500 UL PARTS DIAGRAM 22 12 13 3 58 Figure 14 6 17 7 19 35 34 57 56 5 33 43 44 40 16 4 42 36 53 54 41 28 59 20 32 14 38 31 8 62 23 55 15 25 58 24 39 37 18 20 11 27 21 61 60 2 63 26 52 51-14 -

GLOSSARY CLASSES OF VEHICULAR GATE OPERATORS VEHICULAR HORIZONTAL SLIDE-GATE OPERATOR (OR SYSTEM)- A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like. VEHICULAR SWING-GATE OPERATOR (OR SYSTEM) - A vehicular gate operator (or system) that controls a gate which swings in an arc in a horizontal plane that is intended for use for vehicular entrance or exit to a drive, parking lot or the like. RESIDENTIAL VEHICULAR GATE OPERATOR-CLASS I - A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith. COMMERCIAL/GENERAL ACCESS VEHICULAR GATE OPERATOR- CLASS II- A vehicular gate operator (or system) intended for use in an commercial location or building such as a multi-family housing unit (five or more single family units), hotels, garages, retail stores, or other buildings serving the general public. INDUSTRIAL/LIMITED ACCESS VEHICULAR GATE OPERATOR - CLASS III - A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public. RESTRICTED ACCESS VEHICULAR GATE OPERATOR - CLASS IV - A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel. VISIT OUR WEBSITE A T : WWW.RAMSETINC.COM Ramset Automatic Gate Systems (800) 771-7055 9116 De Garmo Ave. Sun Valley, CA. 91352